-
A quantitative assessment of Geant4 for predicting the yield and distribution of positron-emitting fragments in ion beam therapy
Authors:
Andrew Chacon,
Harley Rutherford,
Akram Hamato,
Munetaka Nitta,
Fumihiko Nishikido,
Yuma Iwao,
Hideaki Tashima,
Eiji Yoshida,
Go Akamatsu,
Sodai Takyu,
Han Gyu Kang,
Daniel R. Franklin,
Katia Parodi,
Taiga Yamaya,
Anatoly Rosenfeld,
Susanna Guatelli,
Mitra Safavi-Naeini
Abstract:
Purpose: To compare the accuracy with which different hadronic inelastic physics models across ten Geant4 Monte Carlo simulation toolkit versions can predict positron-emitting fragments produced along the beam path during carbon and oxygen ion therapy.
Materials and Methods: Phantoms of polyethylene, gelatin or poly(methyl methacrylate) were irradiated with monoenergetic carbon and oxygen ion be…
▽ More
Purpose: To compare the accuracy with which different hadronic inelastic physics models across ten Geant4 Monte Carlo simulation toolkit versions can predict positron-emitting fragments produced along the beam path during carbon and oxygen ion therapy.
Materials and Methods: Phantoms of polyethylene, gelatin or poly(methyl methacrylate) were irradiated with monoenergetic carbon and oxygen ion beams. Post-irradiation, 4D PET images were acquired and parent $^{11}$C, $^{10}$C and $^{15}$O radionuclides contributions in each voxel were determined from the extracted time activity curves. Experiments were simulated in Geant4 Monte Carlo versions 10-11.1, with three different fragmentation models: binary ion cascade (BIC), quantum molecular dynamics (QMD) and the Liege intranuclear cascade (INCL++) - 30 combinations. Total/parent isotope positron annihilation yields were compared between simulations and experiments using normalised mean squared error and Pearson cross-correlation coefficient. Depth of maximum/distal 50\% peak position yield were also compared.
Results: Performance varied considerably across versions and models, with no one best predicting all positron-emitting fragments. BIC in Geant4 10.2 provided the best overall agreement with experimental results in the largest number of test cases. QMD consistently provided the best estimates of both the depth of peak positron yield (10.4 and 10.6) and the distal 50\%-of-peak point (10.2), while BIC also performed well and INCL generally performed the worst across most Geant4 versions. Conclusions: Best spatial prediction of annihilation yield and positron-emitting fragment production during carbon and oxygen ion therapy was found to be 10.2.p03 with BIC or QMD. These version/model combinations are recommended for future heavy ion therapy research.
△ Less
Submitted 14 April, 2024; v1 submitted 5 February, 2024;
originally announced February 2024.
-
Geant4 simulation model of electromagnetic processes in oriented crystals for accelerator physics
Authors:
Alexei Sytov,
Laura Bandiera,
Kihyeon Cho,
Soonwook Hwang,
Giuseppe Antonio Pablo Cirrone,
Luciano Pandola,
Susanna Guatelli,
Anatoly Rosenfeld,
Viktar Haurylavets,
Victor Tikhomirov,
Vladimir Ivanchenko
Abstract:
Electromagnetic processes of charged particles interaction with oriented crystals provide a wide variety of innovative applications such as beam steering, crystal-based extraction/collimation of leptons and hadrons in an accelerator, a fixed-target experiment on magnetic and electric dipole moment measurement, X-ray and gamma radiation source for radiotherapy and nuclear physics and a positron sou…
▽ More
Electromagnetic processes of charged particles interaction with oriented crystals provide a wide variety of innovative applications such as beam steering, crystal-based extraction/collimation of leptons and hadrons in an accelerator, a fixed-target experiment on magnetic and electric dipole moment measurement, X-ray and gamma radiation source for radiotherapy and nuclear physics and a positron source for lepton and muon colliders, a compact crystalline calorimeter as well as plasma acceleration in the crystal media. One of the main challenges is to develop an up-to-date, universal and fast simulation tool to simulate these applications.
We present a new simulation model of electromagnetic processes in oriented crystals implemented into Geant4, which is a toolkit for the simulation of the passage of particles through matter. We validate the model with the experimental data as well as discuss the advantages and perspectives of this model for the applications of oriented crystals mentioned above.
△ Less
Submitted 2 June, 2023; v1 submitted 8 March, 2023;
originally announced March 2023.
-
Accurate and fast deep learning dose prediction for a preclinical microbeam radiation therapy study using low-statistics Monte Carlo simulations
Authors:
Florian Mentzel,
Jason Paino,
Micah Barnes,
Matthew Cameron,
Stéphanie Corde,
Elette Engels,
Kevin Kröninger,
Michael Lerch,
Olaf Nackenhorst,
Anatoly Rosenfeld,
Moeva Tehei,
Ah Chung Tsoi,
Sarah Vogel,
Jens Weingarten,
Markus Hagenbuchner,
Susanna Guatelli
Abstract:
Microbeam radiation therapy (MRT) utilizes coplanar synchrotron radiation beamlets and is a proposed treatment approach for several tumour diagnoses that currently have poor clinical treatment outcomes, such as gliosarcomas. Prescription dose estimations for treating preclinical gliosarcoma models in MRT studies at the Imaging and Medical Beamline at the Australian Synchrotron currently rely on Mo…
▽ More
Microbeam radiation therapy (MRT) utilizes coplanar synchrotron radiation beamlets and is a proposed treatment approach for several tumour diagnoses that currently have poor clinical treatment outcomes, such as gliosarcomas. Prescription dose estimations for treating preclinical gliosarcoma models in MRT studies at the Imaging and Medical Beamline at the Australian Synchrotron currently rely on Monte Carlo (MC) simulations. The steep dose gradients associated with the 50$\,μ$m wide coplanar beamlets present a significant challenge for precise MC simulation of the MRT irradiation treatment field in a short time frame. Much research has been conducted on fast dose estimation methods for clinically available treatments. However, such methods, including GPU Monte Carlo implementations and machine learning (ML) models, are unavailable for novel and emerging cancer radiation treatment options like MRT. In this work, the successful application of a fast and accurate machine learning dose prediction model in a retrospective preclinical MRT rodent study is presented for the first time. The ML model predicts the peak doses in the path of the microbeams and the valley doses between them, delivered to the gliosarcoma in rodent patients. The predictions of the ML model show excellent agreement with low-noise MC simulations, especially within the investigated tumour volume. This agreement is despite the ML model being deliberately trained with MC-calculated samples exhibiting significantly higher statistical uncertainties. The successful use of high-noise training set data samples, which are much faster to generate, encourages and accelerates the transfer of the ML model to different treatment modalities for other future applications in novel radiation cancer therapies.
△ Less
Submitted 6 April, 2023; v1 submitted 11 December, 2022;
originally announced December 2022.
-
A step towards treatment planning for microbeam radiation therapy: fast peak and valley dose predictions with 3D U-Nets
Authors:
Florian Mentzel,
Micah Barnes,
Kevin Kröninger,
Michael Lerch,
Olaf Nackenhorst,
Jason Paino,
Anatoly Rosenfeld,
Ayu Saraswati,
Ah Chung Tsoi,
Jens Weingarten,
Markus Hagenbuchner,
Susanna Guatelli
Abstract:
Fast and accurate dose predictions are one of the bottlenecks in treatment planning for microbeam radiation therapy (MRT). In this paper, we propose a machine learning (ML) model based on a 3D U-Net. Our approach predicts separately the large doses of the narrow high intensity synchrotron microbeams and the lower valley doses between them. For this purpose, a concept of macro peak doses and macro…
▽ More
Fast and accurate dose predictions are one of the bottlenecks in treatment planning for microbeam radiation therapy (MRT). In this paper, we propose a machine learning (ML) model based on a 3D U-Net. Our approach predicts separately the large doses of the narrow high intensity synchrotron microbeams and the lower valley doses between them. For this purpose, a concept of macro peak doses and macro valley doses is introduced, describing the respective doses not on a microscopic level but as macroscopic quantities in larger voxels. The ML model is trained to mimic full Monte Carlo (MC) data. Complex physical effects such as polarization are therefore automatically taking into account by the model.
The macro dose distribution approach described in this study allows for superimposing single microbeam predictions to a beam array field making it an interesting candidate for treatment planning. It is shown that the proposed approach can overcome a main obstacle with microbeam dose predictions by predicting a full microbeam irradiation field in less than a minute while maintaining reasonable accuracy.
△ Less
Submitted 21 November, 2022;
originally announced November 2022.
-
Simulation of DNA damage using Geant4-DNA: an overview of the "molecularDNA" example application
Authors:
Konstantinos P. Chatzipapas,
Ngoc Hoang Tran,
Milos Dordevic,
Sara Zivkovic,
Sara Zein,
Wook Geun Shin,
Dousatsu Sakata,
Nathanael Lampe,
Jeremy M. C. Brown,
Aleksandra Ristic-Fira,
Ivan Petrovic,
Ioanna Kyriakou,
Dimitris Emfietzoglou,
Susanna Guatelli,
Sébastien Incerti
Abstract:
The scientific community shows a great interest in the study of DNA damage induction, DNA damage repair and the biological effects on cells and cellular systems after exposure to ionizing radiation. Several in-silico methods have been proposed so far to study these mechanisms using Monte Carlo simulations. This study outlines a Geant4-DNA example application, named "molecularDNA", publicly release…
▽ More
The scientific community shows a great interest in the study of DNA damage induction, DNA damage repair and the biological effects on cells and cellular systems after exposure to ionizing radiation. Several in-silico methods have been proposed so far to study these mechanisms using Monte Carlo simulations. This study outlines a Geant4-DNA example application, named "molecularDNA", publicly released in the 11.1 version of Geant4 (December 2022). It was developed for novice Geant4 users and requires only a basic understanding of scripting languages to get started. The example currently proposes two different DNA-scale geometries of biological targets, namely "cylinders", and the "human cell". This public version is based on a previous prototype and includes new features such as: the adoption of a new approach for the modeling of the chemical stage (IRT-sync), the use of the Standard DNA Damage (SDD) format to describe radiation-induced DNA damage and upgraded computational tools to estimate DNA damage response. Simulation data in terms of single strand break (SSB) and double strand break (DSB) yields were produced using each of these geometries. The results were compared to the literature, to validate the example, producing less than 5 % difference in all cases.
△ Less
Submitted 20 March, 2023; v1 submitted 4 October, 2022;
originally announced October 2022.
-
Fast and accurate dose predictions for novel radiotherapy treatments in heterogeneous phantoms using conditional 3D-UNet generative adversarial networks
Authors:
Florian Mentzel,
Kevin Kröninger,
Michael Lerch,
Olaf Nackenhorst,
Jason Paino,
Anatoly Rosenfeld,
Ayu Saraswati,
Ah Chung Tsoi,
Jens Weingarten,
Markus Hagenbuchner,
Susanna Guatelli
Abstract:
Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT), require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo physics simulations are recognised to be one of the most accurate tools to predict the dose delivered in a target tissue but can be very time consuming and therefore proh…
▽ More
Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT), require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo physics simulations are recognised to be one of the most accurate tools to predict the dose delivered in a target tissue but can be very time consuming and therefore prohibitive for treatment planning. Faster dose prediction algorithms are usually developed for clinically deployed treatments only. In this work, we explore a new approach for fast and accurate dose estimations suitable for novel treatments using digital phantoms used in pre-clinical development and modern machine learning techniques. We develop a generative adversarial network (GAN) model, which is able to emulate the equivalent Geant4 Monte Carlo simulation with adequate accuracy, and use it to predict the radiation dose delivered by a broad synchrotron beam to various phantoms. The energy depositions used for the training of the GAN are obtained using full Geant4 Monte Carlo simulations of a synchrotron radiation broad beam passing through the phantoms. The energy deposition is scored and predicted in voxel matrices of size 140x18x18 with a voxel edge length of 1 mm. The GAN model consists of two competing 3D convolutional neural networks, which are conditioned on the photon beam and phantom properties. The energy deposition predictions inside all phantom geometries under investigation show deviations of less than 3% of the maximum deposited energy from the simulation for roughly 99% of the voxels in the field of the beam. The computing time for a single prediction is reduced from several hundred hours using Geant4 simulation to less than a second using the GAN model.
△ Less
Submitted 16 February, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
A new Standard DNA damage (SDD) data format
Authors:
J. Schuemann,
A. McNamara,
J. W. Warmenhoven,
N. T. Henthorn,
K. Kirkby,
M. J. Merchant,
S. Ingram,
H. Paganetti,
KD. Held,
J. Ramos-Mendez,
B. Faddegon,
J. Perl,
D. Goodhead,
I. Plante,
H. Rabus,
H. Nettelbeck,
W. Friedland,
P. Kundrat,
A. Ottolenghi,
G. Baiocco,
S. Barbieri,
M. Dingfelder,
S. Incerti,
C. Villagrasa,
M. Bueno
, et al. (26 additional authors not shown)
Abstract:
Our understanding of radiation induced cellular damage has greatly improved over the past decades. Despite this progress, there are still many obstacles to fully understanding how radiation interacts with biologically relevant cellular components to form observable endpoints. One hurdle is the difficulty faced by members of different research groups in directly comparing results. Multiple Monte Ca…
▽ More
Our understanding of radiation induced cellular damage has greatly improved over the past decades. Despite this progress, there are still many obstacles to fully understanding how radiation interacts with biologically relevant cellular components to form observable endpoints. One hurdle is the difficulty faced by members of different research groups in directly comparing results. Multiple Monte Carlo codes have been developed to simulate damage induction at the DNA scale, while at the same time various groups have developed models that describe DNA repair processes with varying levels of detail. These repair models are intrinsically linked to the damage model employed in their development, making it difficult to disentangle systematic effects in either part of the modelling chain. The modelling chain typically consists of track structure Monte Carlo simulations of the physics interactions creating direct damages to the DNA; followed by simulations of the production and initial reactions of chemical species causing indirect damages. After the DNA damage induction, DNA repair models combine the simulated damage patterns with biological models to determine the biological consequences of the damage. We propose a new Standard data format for DNA Damage to unify the interface between the simulation of damage induction and the biological modelling of cell repair processes. Such a standard greatly facilitates inter model comparisons, providing an ideal environment to tease out model assumptions and identify persistent, underlying mechanisms. Through inter model comparisons, this unified standard has the potential to greatly advance our understanding of the underlying mechanisms of radiation induced DNA damage and the resulting observable biological effects.
△ Less
Submitted 11 January, 2022;
originally announced January 2022.
-
Implementing the Independent Reaction Time method in Geant4 for radiation chemistry simulations
Authors:
Mathieu Karamitros,
Jeremy Brown,
Nathanael Lampe,
Dousatsu Sakata,
Ngoc Hoang Tran,
Wook-Guen Shin,
Jose Ramos Mendez,
Susana Guatelli,
Sébastien Incerti,
Jay A. LaVerne
Abstract:
The Independent Reaction Time method is a computationally efficient Monte-Carlo based approach to simulate the evolution of initially heterogeneously distributed reaction-diffusion systems that has seen wide-scale implementation in the field of radiation chemistry modeling. The method gains its efficiency by preventing multiple calculations steps before a reaction can take place. In this work we o…
▽ More
The Independent Reaction Time method is a computationally efficient Monte-Carlo based approach to simulate the evolution of initially heterogeneously distributed reaction-diffusion systems that has seen wide-scale implementation in the field of radiation chemistry modeling. The method gains its efficiency by preventing multiple calculations steps before a reaction can take place. In this work we outline the development and implementation of this method in the Geant4 toolkit to model ionizing radiation induced chemical species in liquid water. The accuracy and validity of these developed chemical models in Geant4 is verified against analytical solutions of well stirred bimolecular systems confined in a fully reflective box.
△ Less
Submitted 25 June, 2020;
originally announced June 2020.
-
Comparative analysis of the secondary electron yield from carbon nanoparticles and pure water medium
Authors:
Alexey Verkhovtsev,
Sally McKinnon,
Pablo de Vera,
Eugene Surdutovich,
Susanna Guatelli,
Andrei V. Korol,
Anatoly Rosenfeld,
Andrey V. Solov'yov
Abstract:
The production of secondary electrons generated by carbon nanoparticles and pure water medium irradiated by fast protons is studied by means of model approaches and Monte Carlo simulations. It is demonstrated that due to a prominent collective response to an external field, the nanoparticles embedded in the medium enhance the yield of low-energy electrons. The maximal enhancement is observed for e…
▽ More
The production of secondary electrons generated by carbon nanoparticles and pure water medium irradiated by fast protons is studied by means of model approaches and Monte Carlo simulations. It is demonstrated that due to a prominent collective response to an external field, the nanoparticles embedded in the medium enhance the yield of low-energy electrons. The maximal enhancement is observed for electrons in the energy range where plasmons, which are excited in the nanoparticles, play the dominant role. Electron yield from a solid carbon nanoparticle composed of fullerite, a crystalline form of C60 fullerene, is demonstrated to be several times higher than that from liquid water. Decay of plasmon excitations in carbon-based nanosystems thus represents a mechanism of increase of the low-energy electron yield, similar to the case of sensitizing metal nanoparticles. This observation gives a hint for investigation of novel types of sensitizers to be composed of metallic and organic parts.
△ Less
Submitted 10 March, 2015;
originally announced March 2015.
-
The Geant4-DNA project
Authors:
S. Incerti,
G. Baldacchino,
M. Bernal,
R. Capra,
C. Champion,
Z. Francis,
S. Guatelli,
P. Gueye,
A. Mantero,
B. Mascialino,
P. Moretto,
P. Nieminen,
A. Rosenfeld,
C. Villagrasa,
C. Zacharatou
Abstract:
The Geant4-DNA project proposes to develop an open-source simulation software based and fully included in the general-purpose Geant4 Monte Carlo simulation toolkit. The main objective of this software is to simulate biological damages induced by ionising radiation at the cellular and sub-cellular scale. This project was originally initiated by the European Space Agency for the prediction of dele…
▽ More
The Geant4-DNA project proposes to develop an open-source simulation software based and fully included in the general-purpose Geant4 Monte Carlo simulation toolkit. The main objective of this software is to simulate biological damages induced by ionising radiation at the cellular and sub-cellular scale. This project was originally initiated by the European Space Agency for the prediction of deleterious effects of radiation that may affect astronauts during future long duration space exploration missions. In this paper, the Geant4-DNA collaboration presents an overview of the whole ongoing project, including its most recent developments already available in the last Geant4 public release (9.3 BETA), as well as an illustration example simulating the direct irradiation of a chromatin fibre. Expected extensions involving several research domains, such as particle physics, chemistry and cellular and molecular biology, within a fully interdiciplinary activity of the Geant4 collaboration are also discussed.
△ Less
Submitted 29 October, 2009;
originally announced October 2009.