-
Phase projection errors in rf-driven optically pumped magnetometers
Authors:
Zoran D. Grujić,
Marija Ćurĉić,
Aleksandra Kocić,
Antoine Weis,
Theo Scholtes
Abstract:
We study the phase between the oscillating (rf) excitation field and the detected (light) power modulation in scalar rf-driven optically pumped magnetometers (OPMs), in particular in the $M_x$ configuration. While the static dependence of the demodulation phase on the direction of the external static magnetic field vector can be largely overcome by aligning the oscillating rf field along the light…
▽ More
We study the phase between the oscillating (rf) excitation field and the detected (light) power modulation in scalar rf-driven optically pumped magnetometers (OPMs), in particular in the $M_x$ configuration. While the static dependence of the demodulation phase on the direction of the external static magnetic field vector can be largely overcome by aligning the oscillating rf field along the light propagation direction, we show that a dynamic (transient) phase response can appear under tilts of the magnetic field. We analytically solve the corresponding modified Bloch equation and obtain agreement with experimental observations in an $M_x$ magnetometer setup using a paraffin-coated Cs vapor cell. The results reveal fundamental limitations of $M_x$ magnetometers in terms of response time and accuracy, in particular when operated with active electronic feedback, e.g., using a phase-locked loop. Thus, the work is highly relevant in important magnetometry applications, where the direction of the quasi-static magnetic field of interest is not known \textit{a priori} and/or not constant over time, or in measurements, in which a large detection bandwidth is paramount. Such conditions are encountered, e.g., in geomagnetic surveying, in particular with mobile platforms.
△ Less
Submitted 30 September, 2024;
originally announced September 2024.
-
A Multi-Messenger Search for Exotic Field Emission with a Global Magnetometer Network
Authors:
Sami S. Khamis,
Ibrahim A. Sulai,
Paul Hamilton,
S. Afach,
B. C. Buchler,
D. Budker,
N. L. Figueroa,
R. Folman,
D. Gavilán-Martín,
M. Givon,
Z. D. Grujić,
H. Guo,
M. P. Hedges,
D. F. Jackson Kimball,
D. Kim,
E. Klinger,
T. Kornack,
A. Kryemadhi,
N. Kukowski,
G. Lukasiewicz,
H. Masia-Roig,
M. Padniuk,
C. A. Palm,
S. Y. Park,
X. Peng
, et al. (16 additional authors not shown)
Abstract:
Quantum sensor networks in combination with traditional astronomical observations are emerging as a novel modality for multi-messenger astronomy. Here we develop a generic analysis framework that uses a data-driven approach to model the sensitivity of a quantum sensor network to astrophysical signals as a consequence of beyond-the-Standard Model (BSM) physics. The analysis method evaluates correla…
▽ More
Quantum sensor networks in combination with traditional astronomical observations are emerging as a novel modality for multi-messenger astronomy. Here we develop a generic analysis framework that uses a data-driven approach to model the sensitivity of a quantum sensor network to astrophysical signals as a consequence of beyond-the-Standard Model (BSM) physics. The analysis method evaluates correlations between sensors to search for BSM signals coincident with astrophysical triggers such as black hole mergers, supernovae, or fast radio bursts. Complementary to astroparticle approaches that search for particlelike signals (e.g. WIMPs), quantum sensors are sensitive to wavelike signals from exotic quantum fields. This analysis method can be applied to networks of different types of quantum sensors, such as atomic clocks, matter-wave interferometers, and nuclear clocks, which can probe many types of interactions between BSM fields and standard model particles.
We use this analysis method to carry out the first direct search utilizing a terrestrial network of precision quantum sensors for BSM fields emitted during a black hole merger. Specifically we use the Global Network of Optical Magnetometers for Exotic physics (GNOME) to perform a search for exotic low-mass field (ELF) bursts generated in coincidence with a gravitational wave signal from a binary black hole merger (GW200311 115853) detected by LIGO/Virgo on the 11th of March 2020. The associated gravitational wave heralds the arrival of the ELF burst that interacts with the spins of fermions in the magnetometers. This enables GNOME to serve as a tool for multi-messenger astronomy. Our search found no significant events, and consequently we place the first lab-based limits on combinations of ELF production and coupling parameters.
△ Less
Submitted 20 May, 2025; v1 submitted 18 July, 2024;
originally announced July 2024.
-
Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
D. Bowles,
E. Chanel,
W. Chen,
P. -J. Chiu,
C. B. Crawford,
O. Naviliat-Cuncic,
C. B. Doorenbos,
S. Emmenegger,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch,
V. Kletzl,
J. Krempel,
B. Lauss,
T. Lefort,
A. Lejuez
, et al. (25 additional authors not shown)
Abstract:
High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optim…
▽ More
High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ~1.4 m^3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12 h down to ~1.5 h.
△ Less
Submitted 28 September, 2023;
originally announced September 2023.
-
A large 'Active Magnetic Shield' for a high-precision experiment
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
J. Chen,
W. Chen,
P. -J. Chiu,
C. B. Crawford,
M. Daum,
C. B. Doorenbos,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujic,
P. Harris,
K. Kirch,
V. Kletzl,
P. A. Koss,
J. Krempel
, et al. (26 additional authors not shown)
Abstract:
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static s…
▽ More
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 10^5 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000m^3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to +-50muT (homogeneous components) and +-5muT (first-order gradients), suppressing them to a few muT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
What can a GNOME do? Search targets for the Global Network of Optical Magnetometers for Exotic physics searches
Authors:
S. Afach,
D. Aybas Tumturk,
H. Bekker,
B. C. Buchler,
D. Budker,
K. Cervantes,
A. Derevianko,
J. Eby,
N. L. Figueroa,
R. Folman,
D. Gavil'an Martin,
M. Givon,
Z. D. Grujic,
H. Guo,
P. Hamilton,
M. P. Hedges,
D. F. Jackson Kimball,
S. Khamis,
D. Kim,
E. Klinger,
A. Kryemadhi,
X. Liu,
G. Lukasiewicz,
H. Masia-Roig,
M. Padniuk
, et al. (28 additional authors not shown)
Abstract:
Numerous observations suggest that there exist undiscovered beyond-the-Standard-Model particles and fields. Because of their unknown nature, these exotic particles and fields could interact with Standard Model particles in many different ways and assume a variety of possible configurations. Here we present an overview of the Global Network of Optical Magnetometers for Exotic physics searches (GNOM…
▽ More
Numerous observations suggest that there exist undiscovered beyond-the-Standard-Model particles and fields. Because of their unknown nature, these exotic particles and fields could interact with Standard Model particles in many different ways and assume a variety of possible configurations. Here we present an overview of the Global Network of Optical Magnetometers for Exotic physics searches (GNOME), our ongoing experimental program designed to test a wide range of exotic physics scenarios. The GNOME experiment utilizes a worldwide network of shielded atomic magnetometers (and, more recently, comagnetometers) to search for spatially and temporally correlated signals due to torques on atomic spins from exotic fields of astrophysical origin. We survey the temporal characteristics of a variety of possible signals currently under investigation such as those from topological defect dark matter (axion-like particle domain walls), axion-like particle stars, solitons of complex-valued scalar fields (Q-balls), stochastic fluctuations of bosonic dark matter fields, a solar axion-like particle halo, and bursts of ultralight bosonic fields produced by cataclysmic astrophysical events such as binary black hole mergers.
△ Less
Submitted 4 May, 2023; v1 submitted 2 May, 2023;
originally announced May 2023.
-
The `n2EDM MSR' -- a very large magnetically shielded room with an exceptional performance for fundamental physics measurements
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
B. Clement,
E. Chanel,
P. -J. Chiu,
C. B. Crawford,
M. Daum,
C. B. Doorenbos,
S. Emmenegger,
A. Fratangelo,
M. Fertl,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch,
J. Krempel,
B. Lauss,
T. Lefort,
O. Naviliat-Cuncic,
D. Pais,
F. M. Piegsa
, et al. (19 additional authors not shown)
Abstract:
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87 openings up to 220mm diameter to operate the experimental apparatus inside, and an intermediate space between the layers for sensitive signal processing electronics.…
▽ More
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87 openings up to 220mm diameter to operate the experimental apparatus inside, and an intermediate space between the layers for sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1m3 below 100pT, and a field below 600pT in the entire inner volume, up to 4\,cm to the walls. The quasi-static shielding factor at 0.01\,Hz measured with a sinusoidal 2muT peak-to-peak signal is about 100,000 in all three spatial directions and rises fast with frequency to reach 10^8 above 1Hz.
△ Less
Submitted 21 June, 2022;
originally announced June 2022.
-
Mapping of the magnetic field to correct systematic effects in a neutron electric dipole moment experiment
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
B. Clément,
C. B. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
L. Hayen,
N. Hild,
M. Kasprzak,
K. Kirch,
P. Knowles,
H. -C. Koch
, et al. (28 additional authors not shown)
Abstract:
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the large…
▽ More
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the largest systematic effect of this measurement. To evaluate and correct that effect, offline measurements of the field non-uniformity were performed during mapping campaigns in 2013, 2014 and 2017. We present the results of these campaigns, and the improvement the correction of this effect brings to the neutron electric dipole moment measurement.
△ Less
Submitted 3 May, 2022; v1 submitted 16 March, 2021;
originally announced March 2021.
-
Search for topological defect dark matter with a global network of optical magnetometers
Authors:
Samer Afach,
Ben C. Buchler,
Dmitry Budker,
Conner Dailey,
Andrei Derevianko,
Vincent Dumont,
Nataniel L. Figueroa,
Ilja Gerhardt,
Zoran D. Grujić,
Hong Guo,
Chuanpeng Hao,
Paul S. Hamilton,
Morgan Hedges,
Derek F. Jackson Kimball,
Dongok Kim,
Sami Khamis,
Thomas Kornack,
Victor Lebedev,
Zheng-Tian Lu,
Hector Masia-Roig,
Madeline Monroy,
Mikhail Padniuk,
Christopher A. Palm,
Sun Yool Park,
Karun V. Paul
, et al. (24 additional authors not shown)
Abstract:
Ultralight bosons such as axion-like particles are viable candidates for dark matter. They can form stable, macroscopic field configurations in the form of topological defects that could concentrate the dark matter density into many distinct, compact spatial regions that are small compared to the galaxy but much larger than the Earth. Here, we report the results of a search for transient signals f…
▽ More
Ultralight bosons such as axion-like particles are viable candidates for dark matter. They can form stable, macroscopic field configurations in the form of topological defects that could concentrate the dark matter density into many distinct, compact spatial regions that are small compared to the galaxy but much larger than the Earth. Here, we report the results of a search for transient signals from axion-like particle domain walls with the Global Network of Optical Magnetometers for Exotic physics searches (GNOME). We search the data, consisting of correlated measurements from optical atomic magnetometers located in laboratories all over the world, for patterns of signals propagating through the network consistent with domain walls. The analysis of data from a continuous month-long operation of the GNOME finds no statistically significant signals, thus placing experimental constraints on such dark matter scenarios.
△ Less
Submitted 7 December, 2021; v1 submitted 26 February, 2021;
originally announced February 2021.
-
Johnson-Nyquist Noise Effects in Neutron Electric-Dipole-Moment Experiments
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
S. Emmenegger,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
K. Kirch,
P. A. Koss,
B. Lauss,
T. Lefort,
P. Mohanmurthy,
O. Naviliat-Cuncic,
D. Pais,
F. M. Piegsa,
G. Pignol,
D. Rebreyend
, et al. (15 additional authors not shown)
Abstract:
Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and v…
▽ More
Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and volume-averaged root-mean-square normal noise amplitudes at a certain frequency bandwidth for a cylindrical geometry. In addition, we model the source of noise as a finite number of current dipoles and demonstrate a method to simulate temporal and three-dimensional spatial dependencies of JNN. The calculations are applied to estimate the impact of JNN on measurements with the new apparatus, n2EDM, at the Paul Scherrer Institute. We demonstrate that the performances of the optically pumped $^{133}$Cs magnetometers and $^{199}$Hg co-magnetometers, which will be used in the apparatus, are not limited by JNN. Further, we find that in measurements deploying a co-magnetometer system, the impact of JNN is negligible for nEDM searches down to a sensitivity of $4\,\times\,10^{-28}\,e\cdot{\rm cm}$ in a single measurement; therefore, the use of economically and mechanically favored solid aluminum electrodes is possible.
△ Less
Submitted 9 July, 2021; v1 submitted 2 February, 2021;
originally announced February 2021.
-
The design of the n2EDM experiment
Authors:
N. J. Ayres,
G. Ban,
L. Bienstman,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
J. Chen,
P. -J. Chiu,
B. Clément,
C. Crawford,
M. Daum,
B. Dechenaux,
C. B. Doorenbos,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
A. Fratangelo,
P. Flaux,
D. Goupillière,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch
, et al. (36 additional authors not shown)
Abstract:
We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnit…
▽ More
We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is given of the experimental method and setup, the sensitivity requirements for the apparatus are derived, and its technical design is described.
△ Less
Submitted 22 January, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.
-
Measurement of the permanent electric dipole moment of the neutron
Authors:
C. Abel,
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
M. Burghoff,
E. Chanel,
Z. Chowdhuri,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
B. Franke,
A. Fratangelo,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten
, et al. (59 additional authors not shown)
Abstract:
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-19…
▽ More
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.
△ Less
Submitted 31 January, 2020;
originally announced January 2020.
-
Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment
Authors:
C. Abel,
S. Afach,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. B. Crawford,
Z. Chowdhuri,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
B. Franke,
W. C. Griffith,
Z. D. Grujić,
L. Hayen,
V. Hélaine,
N. Hild,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
P. Knowles
, et al. (35 additional authors not shown)
Abstract:
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser…
▽ More
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser drives all magnetometers that are located in a high-vacuum chamber, with a selection of the sensors mounted on a high-voltage electrode. We describe details of the Cs sensors' construction and modes of operation, emphasizing the accuracy and sensitivity of the magnetic field readout. We present two applications of the magnetometer array directly beneficial to the nEDM experiment: (i) the implementation of a strategy to correct for the drift of the vertical magnetic field gradient and (ii) a procedure to homogenize the magnetic field. The first reduces the uncertainty of the new nEDM result. The second enables transverse neutron spin relaxation times exceeding 1500 s, improving the statistical sensitivity of the nEDM experiment by about 35% and effectively increasing the rate of nEDM data taking by a factor of 1.8.
△ Less
Submitted 28 April, 2020; v1 submitted 10 December, 2019;
originally announced December 2019.
-
The n2EDM experiment at the Paul Scherrer Institute
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
B. Clement,
C. Crawford,
M. Daum,
S. Emmenegger,
P. Flaux,
L. Ferraris-Bouchez,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
W. Heil,
N. Hild,
K. Kirch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort
, et al. (23 additional authors not shown)
Abstract:
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI…
▽ More
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.
△ Less
Submitted 27 February, 2019; v1 submitted 6 November, 2018;
originally announced November 2018.
-
Characterization of the Global Network of Optical Magnetometers to search for Exotic Physics (GNOME)
Authors:
S. Afach,
D. Budker,
G. DeCamp,
V. Dumont,
Z. D. Grujić,
H. Guo,
D. F. Jackson Kimball,
T. W. Kornack,
V. Lebedev,
W. Li,
H. Masia-Roig,
S. Nix,
M. Padniuk,
C. A. Palm,
C. Pankow,
A. Penaflor,
X. Peng,
S. Pustelny,
T. Scholtes,
J. A. Smiga,
J. E. Stalnaker,
A. Weis,
A. Wickenbrock,
D. Wurm
Abstract:
The Global Network of Optical Magnetometers to search for Exotic physics (GNOME) is a network of geographically separated, time-synchronized, optically pumped atomic magnetometers that is being used to search for correlated transient signals heralding exotic physics. The GNOME is sensitive to nuclear- and electron-spin couplings to exotic fields from astrophysical sources such as compact dark-matt…
▽ More
The Global Network of Optical Magnetometers to search for Exotic physics (GNOME) is a network of geographically separated, time-synchronized, optically pumped atomic magnetometers that is being used to search for correlated transient signals heralding exotic physics. The GNOME is sensitive to nuclear- and electron-spin couplings to exotic fields from astrophysical sources such as compact dark-matter objects (for example, axion stars and domain walls). Properties of the GNOME sensors such as sensitivity, bandwidth, and noise characteristics are studied in the present work, and features of the network's operation (e.g., data acquisition, format, storage, and diagnostics) are described. Characterization of the GNOME is a key prerequisite to searches for and identification of exotic physics signatures.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches
Authors:
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
M. Fertl,
B. Franke,
Z. D. Grujić,
W. Heil,
M. Horras,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozel,
J. Krempel,
B. Lauss,
T. Lefort,
A. Mtchedlishvili,
G. Pignol,
F. M. Piegsa,
P. Prashanth,
G. Quéméner,
M. Rawlik,
D. Rebreyend
, et al. (9 additional authors not shown)
Abstract:
We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of…
▽ More
We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of absorption and polarization is derived. Laser- and lamp-based data-sets can be consistently described by the improved model which permits to compare measurements using the two different light sources and to explain the increase in magnetometer performance. The laser-based magnetometer satisfies the magnetic field sensitivity requirements for the next generation nEDM experiments.
△ Less
Submitted 16 April, 2018;
originally announced April 2018.
-
Search for axion-like dark matter through nuclear spin precession in electric and magnetic fields
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
M. Daum,
M. Fairbairn,
V. V. Flambaum,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
Z. D. Grujić,
P. G. Harris,
N. Hild,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
P. A. Koss,
A. Kozela
, et al. (23 additional authors not shown)
Abstract:
We report on a search for ultra-low-mass axion-like dark matter by analysing the ratio of the spin-precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms for an axion-induced oscillating electric dipole moment of the neutron and an axion-wind spin-precession effect. No signal consistent with dark matter is observed for the axion mass range…
▽ More
We report on a search for ultra-low-mass axion-like dark matter by analysing the ratio of the spin-precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms for an axion-induced oscillating electric dipole moment of the neutron and an axion-wind spin-precession effect. No signal consistent with dark matter is observed for the axion mass range $10^{-24}~\textrm{eV} \le m_a \le 10^{-17}~\textrm{eV}$. Our null result sets the first laboratory constraints on the coupling of axion dark matter to gluons, which improve on astrophysical limits by up to 3 orders of magnitude, and also improves on previous laboratory constraints on the axion coupling to nucleons by up to a factor of 40.
△ Less
Submitted 21 August, 2017;
originally announced August 2017.
-
MPS and ACS with an atomic magnetometer
Authors:
Simone Colombo,
Victor Lebedev,
Zoran D. Grujic,
Vladimir Dolgovskiy,
Antoine Weis
Abstract:
We show that a single atomic magnetometer in a magnetically unshielded environment can be used to perform magnetic particle spectroscopy (MPS) and AC susceptometry (ACS) on liquid-suspended magnetic nanoparticles. We demonstrate methods allowing a simultaneous recording of M(H) and dM/dH(H) dependences of samples containing down to 1 $μ$g of iron. Our results pave the way towards an atomic magneto…
▽ More
We show that a single atomic magnetometer in a magnetically unshielded environment can be used to perform magnetic particle spectroscopy (MPS) and AC susceptometry (ACS) on liquid-suspended magnetic nanoparticles. We demonstrate methods allowing a simultaneous recording of M(H) and dM/dH(H) dependences of samples containing down to 1 $μ$g of iron. Our results pave the way towards an atomic magnetometer based MPI scanner.
△ Less
Submitted 21 December, 2016;
originally announced December 2016.
-
Towards a mechanical MPI scanner based on atomic magnetometry
Authors:
Simone Colombo,
Victor Lebedev,
Alexey Tonyushkin,
Zoran D. Grujic,
Vladimir Dolgovskiy,
Antoine Weis
Abstract:
We report on our progress in the development of an atomic magnetometer (AM) based low-frequency magnetic particle imaging (MPI) scanner, expected to be free from Specific Absorption Rate (SAR) and Peripheral Nerve Stimulation (PNS) constraints. We address major challenges in coil and sensor design due to specific AM properties. Compared to our previous work we have changed the AM's mode of operati…
▽ More
We report on our progress in the development of an atomic magnetometer (AM) based low-frequency magnetic particle imaging (MPI) scanner, expected to be free from Specific Absorption Rate (SAR) and Peripheral Nerve Stimulation (PNS) constraints. We address major challenges in coil and sensor design due to specific AM properties. Compared to our previous work we have changed the AM's mode of operation towards its implementation for detecting weak magnetic nanoparticles (MNP) response fields in the presence of nearby-located strong drive/selection fields. We demonstrate that a pump-probe AM scheme in a buffer gas filled alkali vapour cell can tolerate mT/m gradients while maintaining a sensitivity in the one-digit pT/Hz^(1/2) range over a bandwidth from DC to several kHz. We give a detailed description of the drive/selection coils' geometry and their hardware implementations that provides a field-free-line (FFL) operation, compatible with a best performance AM operation. We estimate the achievable field of view and spatial resolution of the scanner as well as its sensitivity, assuming mechanical scanning of a Resovist sample through the field-free point/line.
△ Less
Submitted 13 January, 2017; v1 submitted 28 November, 2016;
originally announced November 2016.
-
M(H) dependence and size distribution of SPIONs measured by atomic magnetometry
Authors:
Simone Colombo,
Victor Lebedev,
Zoran D. Grujic,
Vladimir Dolgovskiy,
Antoine Weis
Abstract:
We demonstrate that the quasistatic recording of the magnetic excitation function M(H) of superparamagnetic iron oxide magnetic nanoparticle (SPION) suspensions by an atomic magnetometer allows a precise determination of the sample's iron mass content mFe and the particle size distribution.
We demonstrate that the quasistatic recording of the magnetic excitation function M(H) of superparamagnetic iron oxide magnetic nanoparticle (SPION) suspensions by an atomic magnetometer allows a precise determination of the sample's iron mass content mFe and the particle size distribution.
△ Less
Submitted 23 April, 2016;
originally announced April 2016.
-
A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron
Authors:
J. M. Pendlebury,
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Burghoff,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
Z. D. Grujic,
P. G. Harris,
V. Helaine,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss
, et al. (25 additional authors not shown)
Abstract:
We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calcula…
▽ More
We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calculation of the spectrum of the neutrons; and conservative estimates of other possible systematic errors, which are also shown to be consistent with more recent measurements undertaken with the apparatus. We obtain a net result of $d_\mathrm{n} = -0.21 \pm 1.82 \times10^{-26}$ $e$cm, which may be interpreted as a slightly revised upper limit on the magnitude of the EDM of $3.0 \times10^{-26}$ $e$cm (90% CL) or $ 3.6 \times10^{-26}$ $e$cm (95% CL).
This paper is dedicated by the remaining authors to the memory of Prof. J. Michael Pendlebury.
△ Less
Submitted 13 October, 2015; v1 submitted 15 September, 2015;
originally announced September 2015.
-
A highly stable atomic vector magnetometer based on free spin precession
Authors:
S. Afach,
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
Z. D. Grujic,
L. Hayen,
V. Helaine,
M. Kasprzak,
K. Kirch,
P. Knowles,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemiere,
A. Mtchedlishvili,
O. Naviliat-Cuncic,
F. M. Piegsa,
P. N. Prashanth,
G. Quemener,
M. Rawlik,
D. Ries
, et al. (9 additional authors not shown)
Abstract:
We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 $μ$T magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scal…
▽ More
We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 $μ$T magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scalar resolution of less than 80 fT was reached with integration times of 1.6 to 6 s. We were able to measure the magnetic field direction with a resolution better than 10 $μ$rad for integration times from 10 s up to 2000 s.
△ Less
Submitted 30 July, 2015;
originally announced July 2015.
-
Gravitational Depolarization of Ultracold Neutrons: Comparison with Data
Authors:
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Fertl,
B. Franke,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
Z. D. Grujic,
P. G. Harris,
W. Heil,
V. Helaine,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel
, et al. (25 additional authors not shown)
Abstract:
We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency…
▽ More
We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency. We find excellent qualitative agreement, with gravitationally enhanced depolarization accounting for several previously unexplained features in the data.
△ Less
Submitted 26 August, 2015; v1 submitted 22 June, 2015;
originally announced June 2015.
-
Observation of gravitationally induced vertical striation of polarized ultracold neutrons by spin-echo spectroscopy
Authors:
S. Afach,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
W. Heil,
V. Hélaine,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
P. Knowles,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemière
, et al. (23 additional authors not shown)
Abstract:
We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a $|B_0|=1~\text{μT}$ magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method…
▽ More
We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a $|B_0|=1~\text{μT}$ magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method takes advantage of the relative dephasing of spins arising from a gravitationally induced striation of stored UCN of different energies, and also permits an improved determination of the vertical magnetic-field gradient with an exceptional accuracy of $1.1~\text{pT/cm}$. This novel combination of a well-known nuclear resonance method and gravitationally induced vertical striation is unique in the realm of nuclear and particle physics and should prove to be invaluable for the assessment of systematic effects in precision experiments such as searches for an electric dipole moment of the neutron or the measurement of the neutron lifetime.
△ Less
Submitted 8 September, 2015; v1 submitted 1 June, 2015;
originally announced June 2015.
-
A device for simultaneous spin analysis of ultracold neutrons
Authors:
S. Afach,
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
P. Geltenbort,
Z. D. Grujić,
L. Hayen,
V. Hélaine,
R. Henneck,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
O. Naviliat-Cuncic,
F. M. Piegsa
, et al. (15 additional authors not shown)
Abstract:
We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons.…
▽ More
We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons. The gain in statistical sensitivity obtained with the simultaneous spin analyser is $(18.2\pm6.1)\%$ relative to the former sequential analyser under nominal running conditions.
△ Less
Submitted 12 October, 2015; v1 submitted 24 February, 2015;
originally announced February 2015.
-
Design and performance of an absolute $^3$He/Cs magnetometer
Authors:
H. -C. Koch,
G. Bison,
Z. D. Grujić,
W. Heil,
M. Kasprzak,
P. Knowles,
A. Kraft,
A. Pazgalev,
A. Schnabel,
J. Voigt,
A. Weis
Abstract:
We report on the design and performance of a highly sensitive combined $^3$He/Cs magnetometer for the absolute measurement of magnetic fields. The magnetometer relies on the magnetometric detection of the free spin precession of nuclear spin polarized $^3$He gas by optically pumped cesium magnetometers. We plan to deploy this type of combined magnetometer in an experiment searching for a permanent…
▽ More
We report on the design and performance of a highly sensitive combined $^3$He/Cs magnetometer for the absolute measurement of magnetic fields. The magnetometer relies on the magnetometric detection of the free spin precession of nuclear spin polarized $^3$He gas by optically pumped cesium magnetometers. We plan to deploy this type of combined magnetometer in an experiment searching for a permanent electric dipole moment of ultracold neutrons at the Paul Scherrer Institute (Switzerland). A prototype magnetometer was built at the University of Fribourg (Switzerland) and tested at Physikalisch-Technische Bundesanstalt (Berlin, Germany). We demonstrate that the combined magnetometer allows Cramér-Rao- limited field determinations with recording times in the range of $\sim 500\mathrm{s}$, measurements above $500\mathrm{s}$ being limited by the stability of the applied magnetic field. % With a $100\mathrm{s}$ recording time we were able to perform an absolute measurement of a magnetic field of $\approx1\mathrm{μT}$ with a standard uncertainty of $ΔB\sim60\mathrm{fT}$, corresponding to $ΔB/B<$6$\times$10$^{-8}$.
△ Less
Submitted 24 August, 2015; v1 submitted 23 February, 2015;
originally announced February 2015.
-
A high-sensitivity push-pull magnetometer
Authors:
E. Breschi,
Z. D. Grujic,
P. Knowles,
A. Weis
Abstract:
We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/\sqrt(Hz) using a r…
▽ More
We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/\sqrt(Hz) using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/\sqrt(Hz).
△ Less
Submitted 6 December, 2013;
originally announced December 2013.
-
Atomic magnetic resonance induced by amplitude-, frequency-, or polarization-modulated light
Authors:
Z. D. Grujić,
A. Weis
Abstract:
In recent years diode laser sources have become widespread and reliable tools in magneto-optical spectroscopy. In particular, laser-driven atomic magnetometers have found a wide range of practical applications. More recently, so-called magnetically silent variants of atomic magnetometers have been developed. While in conventional magnetometers the magnetic resonance transitions between atomic subl…
▽ More
In recent years diode laser sources have become widespread and reliable tools in magneto-optical spectroscopy. In particular, laser-driven atomic magnetometers have found a wide range of practical applications. More recently, so-called magnetically silent variants of atomic magnetometers have been developed. While in conventional magnetometers the magnetic resonance transitions between atomic sublevels are phase-coherently driven by a weak oscillating magnetic field, silent magnetometers use schemes in which either the frequency (FM) or the amplitude (AM) of the light beam is modulated. Here we present a theoretical model that yields algebraic expressions for the parameters of the multiple resonances that occur when either amplitude-, frequency- or polarization-modulated light of circular polarization is used to drive the magnetic resonance transition in a transverse magnetic field. The relative magnitudes of the resonances that are observed in the transmitted light intensity at harmonic m of the Larmor frequency ω_L (either by DC or phase sensitive detection at harmonics q of the modulation frequency ω_mod) of the transmitted light are expressed in terms of the Fourier coefficients of the modulation function. Our approach is based on an atomic multipole moment representation that is valid for spin-oriented atomic states with arbitrary angular momentum F in the low light power limit. We find excellent quantitative agreement with an experimental case study using (square-wave) amplitude-modulated (AM) light.
△ Less
Submitted 28 May, 2013;
originally announced May 2013.