-
Pile-Up Mitigation using Attention
Authors:
Benedikt Maier,
Siddharth M. Narayanan,
Gianfranco de Castro,
Maxim Goncharov,
Christoph Paus,
Matthias Schott
Abstract:
Particle production from secondary proton-proton collisions, commonly referred to as pile-up, impair the sensitivity of both new physics searches and precision measurements at LHC experiments. We propose a novel algorithm, PUMA, for identifying pile-up objects with the help of deep neural networks based on sparse transformers. These attention mechanisms were developed for natural language processi…
▽ More
Particle production from secondary proton-proton collisions, commonly referred to as pile-up, impair the sensitivity of both new physics searches and precision measurements at LHC experiments. We propose a novel algorithm, PUMA, for identifying pile-up objects with the help of deep neural networks based on sparse transformers. These attention mechanisms were developed for natural language processing but have become popular in other applications. In a realistic detector simulation, our method outperforms classical benchmark algorithms for pile-up mitigation in key observables. It provides a perspective for mitigating the effects of pile-up in the high luminosity era of the LHC, where up to 200 proton-proton collisions are expected to occur simultaneously.
△ Less
Submitted 2 November, 2022; v1 submitted 6 July, 2021;
originally announced July 2021.
-
Direct determination of the atomic mass difference of Re187 and Os187 for neutrino physics and cosmochronology
Authors:
D. A. Nesterenko,
S. Eliseev,
K. Blaum,
M. Block,
S. Chenmarev,
A. Doerr,
C. Droese,
P. E. Filianin,
M. Goncharov,
E. Minaya Ramirez,
Yu. N. Novikov,
L. Schweikhard,
V. V. Simon
Abstract:
For the first time a direct determination of the atomic mass difference of 187Re and 187Os has been performed with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. The obtained value of 2492(30stat)(15sys) eV is in excellent agreement with the Q values determined indirectly with microcalorimetry and thus resolves a long-standing discre…
▽ More
For the first time a direct determination of the atomic mass difference of 187Re and 187Os has been performed with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. The obtained value of 2492(30stat)(15sys) eV is in excellent agreement with the Q values determined indirectly with microcalorimetry and thus resolves a long-standing discrepancy with older proportional counter measurements. This is essential for the determination of the neutrino mass from the beta-decay of 187Re as planned in future microcalorimetric measurements. In addition, an accurate mass difference of 187Re and 187Os is also important for the assessment of 187Re for cosmochronology.
△ Less
Submitted 15 April, 2016;
originally announced April 2016.
-
Direct Measurement of the Mass Difference of Ho163 and Dy163 Solves the Q-Value Puzzle for the Neutrino Mass Determination
Authors:
S. Eliseev,
K. Blaum,
M. Block,
S. Chenmarev,
H. Dorrer,
Ch. E. Duellmann,
C. Enss,
P. E. Filianin,
L. Gastaldo,
M. Goncharov,
U. Koester,
F. Lautenschlaeger,
Yu. N. Novikov,
A. Rischka,
R. X. Schuessler,
L. Schweikhard,
A. Tuerler
Abstract:
The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing problem of large discrepancies in the Q value of the electron capture in 163Ho determined by different techniques. Our measured mass difference shifts the current Q…
▽ More
The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing problem of large discrepancies in the Q value of the electron capture in 163Ho determined by different techniques. Our measured mass difference shifts the current Q value of 2555(16) eV evaluated in the Atomic Mass Evaluation 2012 [G. Audi et al., Chin. Phys. C 36, 1157 (2012)] by more than 7 sigma to 2833(30stat)(15sys) eV/c2. With the new mass difference it will be possible, e.g., to reach in the first phase of the ECHo experiment a statistical sensitivity to the neutrino mass below 10 eV, which will reduce its present upper limit by more than an order of magnitude.
△ Less
Submitted 14 April, 2016;
originally announced April 2016.
-
PENTATRAP: A novel cryogenic multi-Penning trap experiment for high-precision mass measurements on highly charged ions
Authors:
J. Repp,
Ch. Böhm,
J. R. Crespo López-Urrutia,
A. Dörr,
S. Eliseev,
S. George,
M. Goncharov,
Yu. N. Novikov,
C. Roux,
S. Sturm,
S. Ulmer,
K. Blaum
Abstract:
The novel five-Penning trap mass spectrometer PENTATRAP is developed at the Max-Planck-Institut für Kernphysik (MPIK), Heidelberg. Ions of interest are long-lived highly charged nuclides up to bare uranium. PENTATRAP aims for an accuracy of a few parts in 10^12 for mass ratios of mass doublets. A physics program for PENTATRAP includes Q-values measurements of β-transitions relevant for neutrino ph…
▽ More
The novel five-Penning trap mass spectrometer PENTATRAP is developed at the Max-Planck-Institut für Kernphysik (MPIK), Heidelberg. Ions of interest are long-lived highly charged nuclides up to bare uranium. PENTATRAP aims for an accuracy of a few parts in 10^12 for mass ratios of mass doublets. A physics program for PENTATRAP includes Q-values measurements of β-transitions relevant for neutrino physics, stringent tests of quantum electrodynamics in the regime of extreme electric fields, and a test of special relativity. Main features of PENTATRAP are an access to a source of highly charged ions, a multi-trap configuration, simultaneous measurements of frequencies, a continuous precise monitoring of magnetic field fluctuations, a fast exchange between different ions, and a highly sensitive cryogenic non-destructive detection system. This paper gives a motivation for the new mass spectrometer PENTATRAP, presents its experimental setup, and describes the present status.
△ Less
Submitted 13 October, 2011;
originally announced October 2011.
-
The Timing System for the CDF Electromagnetic Calorimeters
Authors:
M. Goncharov,
T. Kamon,
V. Khotilovich,
V. Krutelyov,
S. W. Lee,
D. Toback,
P. Wagner,
H. Frisch,
H. Sanders,
M. Cordelli,
F. Happacher,
S. Miscetti,
R. Wagner
Abstract:
We report on the design and performance of the electromagnetic calorimeter timing readout system (EMTiming) for the Collider Detector at Fermilab (CDF). The system will be used in searches for rare events with high energy photons to verify that the photon is in time with the event collision, to reject cosmic ray and beam halo backgrounds, and to allow direct searches for new heavy long-lived par…
▽ More
We report on the design and performance of the electromagnetic calorimeter timing readout system (EMTiming) for the Collider Detector at Fermilab (CDF). The system will be used in searches for rare events with high energy photons to verify that the photon is in time with the event collision, to reject cosmic ray and beam halo backgrounds, and to allow direct searches for new heavy long-lived particles that decay to photons. The installation and commissioning of all 862 channels was completed in Fall 2004 as part of an upgrade to the Run II version of the detector. Using in-situ data, including electrons from W=>e nu and Z => ee decays, we measure the energy threshold for a time to be recorded to be 3.8 \pm 0.3GeV in the central portion of the detector and 1.9 \pm 0.1 GeV in the plug portion. Similarly, we measure a timing resolution of 600 \pm 10 ps and 610 \pm 10 ps for electrons above 10 GeV and 6 GeV respectively. There are very few system pathologies such as recording a time when no energy is deposited, or recording a second, fake time for a single energy deposit.
△ Less
Submitted 19 December, 2005;
originally announced December 2005.