-
Delay in electronic vortex states created by multiphoton ionization with single elliptically polarized laser pulses
Authors:
Edward McManus,
Phi-Hung Tran,
Michael Davino,
Tobias Saule,
Van-Hung Hoang,
Thomas Weinacht,
George Gibson,
Anh-Thu Le,
Carlos A. Trallero-Herrero
Abstract:
We show experimentally and theoretically that vortex-shaped structures in the photoelectron momentum distribution can be observed for atoms interacting with a single intense elliptically polarized laser pulse. Our analysis reveals that these spiral structures are the result of destructive interference of two dominant photoelectron vortex states, which are released into the continuum by strong-fiel…
▽ More
We show experimentally and theoretically that vortex-shaped structures in the photoelectron momentum distribution can be observed for atoms interacting with a single intense elliptically polarized laser pulse. Our analysis reveals that these spiral structures are the result of destructive interference of two dominant photoelectron vortex states, which are released into the continuum by strong-field ionization. An electron born into one of those states is temporarily delayed near the atomic core by the combined atomic and laser potential, leading to fast changes in the phase delay with energy for photoelectrons in these vortex states. Our results open the door to studying electron dynamics of vortex states in strong-field ionization.
△ Less
Submitted 26 September, 2025;
originally announced September 2025.
-
Symmetries in 3D photoelectron momentum spectroscopy as precursory methods for dichroic and enantiosensitive measurements
Authors:
Michael Davino,
Edward McManus,
Tobias Saule,
Phi-Hung Tran,
Andrés F. Ordóñez,
George Gibson,
Anh-Thu Le,
Carlos A. Trallero-Herrero
Abstract:
3D photoelectron angular distributions (PADs) are measured from an atomic target ionized by ultrafast, elliptical fields of opposite handedness. Comparing these PADs to one another and to numeric simulations, a difficult to avoid systematic error in their orientation is identified and subsequently corrected by imposing the dichroic symmetry by which they are necessarily related. We show that this…
▽ More
3D photoelectron angular distributions (PADs) are measured from an atomic target ionized by ultrafast, elliptical fields of opposite handedness. Comparing these PADs to one another and to numeric simulations, a difficult to avoid systematic error in their orientation is identified and subsequently corrected by imposing the dichroic symmetry by which they are necessarily related. We show that this correction can be directly applied to molecular targets in the same fields. This paves the way for measurement of enantiosensitive information which has yet to be accessed experimentally.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
High-power femtosecond molecular broadening and the effects of ro-vibrational coupling
Authors:
Kevin Watson,
Tobias Saule,
Maksym Ivanov,
Bruno E. Schmidt,
Zhanna Rodnova,
George Gibson,
Nora Berrah,
Carlos Trallero
Abstract:
Scaling spectral broadening to higher pulse energies and average powers, respectively, is a critical step in ultrafast science, especially for narrowband Yb based solid state lasers which become the new state of the art. Despite their high nonlinearity, molecular gases as the broadening medium inside hollow core fibers have been limited to 25 W, at best. We demonstrate spectral broadening in nitro…
▽ More
Scaling spectral broadening to higher pulse energies and average powers, respectively, is a critical step in ultrafast science, especially for narrowband Yb based solid state lasers which become the new state of the art. Despite their high nonlinearity, molecular gases as the broadening medium inside hollow core fibers have been limited to 25 W, at best. We demonstrate spectral broadening in nitrogen at ten-fold average powers up to 250W with repetition rates from 25 to 200kHz. The observed ten-fold spectral broadening is stronger compared to the more expensive krypton gas and enables pulse compression from 1.3ps to 120fs. We identified an intuitive explanation for the observed average power scaling based on the density of molecular ro vibrational states of Raman active molecules. To verify this ansatz, spectral broadening limitations in O2 and N2O are experimentally measured and agree well. On these grounds we propose a new perspective on the role, suitability, and limits of stimulated Raman scattering at high average and peak powers. Finally, high harmonic generation is demonstrated at 200 kHz.
△ Less
Submitted 3 May, 2024;
originally announced May 2024.
-
A manufacturable platform for photonic quantum computing
Authors:
Koen Alexander,
Andrea Bahgat,
Avishai Benyamini,
Dylan Black,
Damien Bonneau,
Stanley Burgos,
Ben Burridge,
Geoff Campbell,
Gabriel Catalano,
Alex Ceballos,
Chia-Ming Chang,
CJ Chung,
Fariba Danesh,
Tom Dauer,
Michael Davis,
Eric Dudley,
Ping Er-Xuan,
Josep Fargas,
Alessandro Farsi,
Colleen Fenrich,
Jonathan Frazer,
Masaya Fukami,
Yogeeswaran Ganesan,
Gary Gibson,
Mercedes Gimeno-Segovia
, et al. (70 additional authors not shown)
Abstract:
Whilst holding great promise for low noise, ease of operation and networking, useful photonic quantum computing has been precluded by the need for beyond-state-of-the-art components, manufactured by the millions. Here we introduce a manufacturable platform for quantum computing with photons. We benchmark a set of monolithically-integrated silicon photonics-based modules to generate, manipulate, ne…
▽ More
Whilst holding great promise for low noise, ease of operation and networking, useful photonic quantum computing has been precluded by the need for beyond-state-of-the-art components, manufactured by the millions. Here we introduce a manufacturable platform for quantum computing with photons. We benchmark a set of monolithically-integrated silicon photonics-based modules to generate, manipulate, network, and detect photonic qubits, demonstrating dual-rail photonic qubits with $99.98\% \pm 0.01\%$ state preparation and measurement fidelity, Hong-Ou-Mandel quantum interference between independent photon sources with $99.50\%\pm0.25\%$ visibility, two-qubit fusion with $99.22\%\pm0.12\%$ fidelity, and a chip-to-chip qubit interconnect with $99.72\%\pm0.04\%$ fidelity, not accounting for loss. In addition, we preview a selection of next generation technologies, demonstrating low-loss silicon nitride waveguides and components, fabrication-tolerant photon sources, high-efficiency photon-number-resolving detectors, low-loss chip-to-fiber coupling, and barium titanate electro-optic phase shifters.
△ Less
Submitted 26 April, 2024;
originally announced April 2024.
-
3D audio-visual recordings of mosquito wings for aeroacoustic simulation
Authors:
Lionel Feugère,
Jung-Hee Seo,
Umair Ismail,
Gabriella Gibson,
Rajat Mittal
Abstract:
Mosquito acoustic communication is studied for its singular and poorly-known in-flight hearing mechanism, for its efficiency in mechanical-to-acoustical power transduction, as well as for being the deadliest disease vector. A combined computational and experimental methods to predict and extract the wing-tone sound from individual tethered or free-flying mosquitoes was developed. This paper descri…
▽ More
Mosquito acoustic communication is studied for its singular and poorly-known in-flight hearing mechanism, for its efficiency in mechanical-to-acoustical power transduction, as well as for being the deadliest disease vector. A combined computational and experimental methods to predict and extract the wing-tone sound from individual tethered or free-flying mosquitoes was developed. This paper describes the experimental methods and gives some preliminary results of the simulations. Simultaneous slow-motion images (20k fps) and 3D-sound of Culex quinquefasciatus mosquitoes were recorded. The sound map around the mosquitoes was recorded in one or two planes with a rotating array of 12-microphones. Backilluminated mosquito-wings allowed to extract 11 veincrossing locations on each high-speed camera image over 3-4 wingbeat periods to generate 3D deformations of the wing. Simultaneous 3D sound data recorded by microphone arrays were post-processed by using the physicsbased independent component analysis to filter out the noise and generate a 3D sound map. The simulated wingtone sound pattern generated from the aeroacoustic simulation agrees well with the original recording in the experiment using the microphone array. The methods we developed will allow us to investigate the wing-tone soundscape of individual mosquitoes during the courtship and mate-chasing.
△ Less
Submitted 4 January, 2024; v1 submitted 25 September, 2023;
originally announced January 2024.
-
Molecular alignment-assisted spectral broadening and shifting in the near-infrared with a recycled depleted pump from an optical parametric amplifier
Authors:
Zhanna Rodnova,
Tobias Saule,
George Gibson,
Carlos A. Trallero-Herrero
Abstract:
We demonstrate how the depleted pump of an optical parametric amplifier can be recycled for impulsive alignment of a molecular gas inside a hollow-core fiber and use such alignment for the broadening and frequency shift of the signal pulse at a center wavelength of $\sim 1300$nm. Our results combine non-adiabatic molecular alignment, self-phase modulation and Raman non-linearities. We demonstrate…
▽ More
We demonstrate how the depleted pump of an optical parametric amplifier can be recycled for impulsive alignment of a molecular gas inside a hollow-core fiber and use such alignment for the broadening and frequency shift of the signal pulse at a center wavelength of $\sim 1300$nm. Our results combine non-adiabatic molecular alignment, self-phase modulation and Raman non-linearities. We demonstrate spectral shifts of up to 204 nm and a spectral broadening of more than one octave. We also report on the time delays at which broadening occurs, which do not coincide with any of the molecular rotational constants. Further, we encounter that maximum frequency shifts occur when the signal and pump have perpendicular polarization instead of parallel.
△ Less
Submitted 10 August, 2023;
originally announced August 2023.
-
Generation and control of non-local quantum equivalent extreme ultraviolet photons
Authors:
Geoffrey R. Harrison,
Tobias Saule,
R. Esteban Goetz,
George N. Gibson,
Anh-Thu Le,
Carlos A. Trallero-Herrero
Abstract:
We present a high precision, self-referencing, common path XUV interferometer setup to produce pairs of spatially separated and independently controllable XUV pulses that are locked in phase and time. The spatial separation is created by introducing two equal but opposite wavefront tilts or using superpositions of orbital angular momentum. In our approach, we can independently control the relative…
▽ More
We present a high precision, self-referencing, common path XUV interferometer setup to produce pairs of spatially separated and independently controllable XUV pulses that are locked in phase and time. The spatial separation is created by introducing two equal but opposite wavefront tilts or using superpositions of orbital angular momentum. In our approach, we can independently control the relative phase/delay of the two optical beams with a resolution of 52 zs (zs = zeptoseconds). In order to explore the level of entanglement between the non-local photons, we compare three different beam modes: Bessel-like, and Gaussian with or without added orbital angular momentum. By reconstructing interference patterns one or two photons at a time we conclude that the beams are not entangled, yet each photon in the attosecond pulse train contains information about the entire spectrum. Our technique generates non-local, quantum equivalent XUV photons with a temporal jitter of 3 zs, just below the Compton unit of time of 8 zs. We argue that this new level of temporal precision will open the door for new dynamical QED tests. We also discuss the potential impact on other areas, such as imaging, measurements of non-locality, and molecular quantum tomography.
△ Less
Submitted 26 May, 2023;
originally announced May 2023.
-
Polarised light modular microscopy (Pol-ModMicro) for identifying hemozoin crystals in Plasmodium
Authors:
Fraser Eadie,
Matthew P Gibbins,
Graham Gibson,
Matthias Marti,
Akhil Kallepalli
Abstract:
Plasmodium spp. are the protozoan parasites responsible for malaria. Plasmodium spp. synthesise a biocrystal, hemozoin, which can be observed under cross-polarised light. These birefringent crystals can be seen due to different refractive indices of the hemozoin crystal and red blood cells. Here, we present a polarised light modular microscopy (Pol-ModMicro) solution, complete with illumination so…
▽ More
Plasmodium spp. are the protozoan parasites responsible for malaria. Plasmodium spp. synthesise a biocrystal, hemozoin, which can be observed under cross-polarised light. These birefringent crystals can be seen due to different refractive indices of the hemozoin crystal and red blood cells. Here, we present a polarised light modular microscopy (Pol-ModMicro) solution, complete with illumination sources and a robust imaging system to capture birefringence and identify the parasites. We achieve this by combining ModLight light sources with bespoke components designed for the OpenFlexure microscope to image blood smears. Further, a simple and robust algorithm capable of enhancing birefringence is presented. This solution provides image quality that is comparable to a substantially more expensive proprietary microscope.
△ Less
Submitted 26 April, 2023;
originally announced April 2023.
-
Photon-efficient optical tweezers via wavefront shaping
Authors:
Unė G. Būtaitė,
Christina Sharp,
Michael Horodynski,
Graham M. Gibson,
Miles J. Padgett,
Stefan Rotter,
Jonathan M. Taylor,
David B. Phillips
Abstract:
Optical tweezers enable non-contact trapping of micro-scale objects using light. Despite their widespread use, it is currently not known how tightly it is possible to three-dimensionally trap micro-particles with a given photon budget. Reaching this elusive limit would enable maximally-stiff particle trapping for precision measurements on the nanoscale, and photon-efficient tweezing of light-sensi…
▽ More
Optical tweezers enable non-contact trapping of micro-scale objects using light. Despite their widespread use, it is currently not known how tightly it is possible to three-dimensionally trap micro-particles with a given photon budget. Reaching this elusive limit would enable maximally-stiff particle trapping for precision measurements on the nanoscale, and photon-efficient tweezing of light-sensitive objects. Here we solve this problem by customising a trapping light field to suit a specific particle, with the aim of simultaneously optimising trap stiffness in all three dimensions. Initially taking a theoretical approach, we develop an efficient multi-parameter optimisation routine to design bespoke optical traps for a wide range of micro-particles. We show that the confinement volume of micro-spheres held in these sculpted traps can be reduced by one-to-two orders-of-magnitude in comparison to a conventional optical tweezer of the same power. We go on to conduct proof-of-principle experiments, and use a wavefront shaping inspired strategy to suppress the Brownian fluctuations of optically trapped micro-spheres in every direction concurrently, thus demonstrating order-of-magnitude reductions in their confinement volumes. Our work paves the way towards the fundamental limits of optical control over the mesoscopic realm.
△ Less
Submitted 25 April, 2023;
originally announced April 2023.
-
The role of elastic instability on the self-assembly of particle chains in simple shear flow
Authors:
Matthew G. Smith,
Graham M. Gibson,
Andreas Link,
Anand Raghavan,
Andrew Clarke,
Thomas Franke,
Manlio Tassieri
Abstract:
Flow-Induced Self-Assembly (FISA) is the phenomena of particle chaining in viscoelastic fluids while experiencing shear flow. FISA has a large number of applications across many fields including material science, food processing and biomedical engineering. Nonetheless, this phenomena is currently not fully understood and little has been done in literature so far to investigate the possible effects…
▽ More
Flow-Induced Self-Assembly (FISA) is the phenomena of particle chaining in viscoelastic fluids while experiencing shear flow. FISA has a large number of applications across many fields including material science, food processing and biomedical engineering. Nonetheless, this phenomena is currently not fully understood and little has been done in literature so far to investigate the possible effects of the shear-induced elastic instability. In this work, a bespoke cone and plate shear cell is used to provide new insights on the FISA dynamics. In particular, we have fine tuned the applied shear rates to investigate the chaining phenomenon of micron-sized spherical particles suspended into a viscoelastic fluid characterised by a distinct onset of elastic instability. This has allowed us to reveal three phenomena never reported in literature before, i.e.: (I) the onset of the elastic instability is strongly correlated with an enhancement of FISA; (II) particle chains break apart when a constant shear is applied for `sufficiently' long-time (i.e. much longer than the fluids' longest relaxation time). This latter point correlates well with the outcomes of parallel superposition shear measurements, which (III) reveal a fading of the elastic component of the suspending fluid during continuous shear flows.
△ Less
Submitted 8 December, 2023; v1 submitted 17 March, 2023;
originally announced March 2023.
-
Machine learning opens a doorway for microrheology with optical tweezers in living systems
Authors:
Matthew G. Smith,
Jack Radford,
Eky Febrianto,
Jorge Ramírez,
Helen O'Mahony,
Andrew B. Matheson,
Graham M. Gibson,
Daniele Faccio,
Manlio Tassieri
Abstract:
It has been argued [Tassieri, \textit{Soft Matter}, 2015, \textbf{11}, 5792] that linear microrheology with optical tweezers (MOT) of living systems ``\textit{is not an option}'', because of the wide gap between the observation time required to collect statistically valid data and the mutational times of the organisms under study. Here, we have taken a first step towards a possible solution of thi…
▽ More
It has been argued [Tassieri, \textit{Soft Matter}, 2015, \textbf{11}, 5792] that linear microrheology with optical tweezers (MOT) of living systems ``\textit{is not an option}'', because of the wide gap between the observation time required to collect statistically valid data and the mutational times of the organisms under study. Here, we have taken a first step towards a possible solution of this problem by exploiting modern machine learning (ML) methods to reduce the duration of MOT measurements from several tens of minutes down to one second. This has been achieved by focusing on the analysis of computer simulated trajectories of an optically trapped particle suspended in a set of Newtonian fluids having viscosity values spanning three orders of magnitude, i.e. from $10^{-3}$ to $1$ Pa$\cdot$s. When the particle trajectory is analysed by means of conventional statistical mechanics principles, we explicate for the first time in literature the relationship between the required duration of MOT experiments ($T_m$) and the fluids relative viscosity ($η_r$) to achieve an uncertainty as low as $1\%$; i.e., $T_m\cong 17η_r^3$ minutes. This has led to further evidences explaining why conventional MOT measurements commonly underestimate the materials' viscoelastic properties, especially in the case of high viscous fluids or soft-solids such as gels and cells. Finally, we have developed a ML algorithm to determine the viscosity of Newtonian fluids that uses feature extraction on raw trajectories acquired at a kHz and for a duration of only one second, yet capable of returning viscosity values carrying an error as low as $\sim0.3\%$ at best; hence the opening of a doorway for MOT in living systems.
△ Less
Submitted 17 November, 2022;
originally announced November 2022.
-
Controlling Photon Entanglement with Mechanical Rotation
Authors:
Marion Cromb,
Sara Restuccia,
Graham M. Gibson,
Marko Toros,
Miles J. Padgett,
Daniele Faccio
Abstract:
Understanding quantum mechanics within curved spacetime is a key stepping stone towards understanding the nature of spacetime itself. Whilst various theoretical models have been developed,
it is significantly more challenging to carry out actual experiments that probe quantum mechanics in curved spacetime.
By adding Sagnac interferometers into the arms of a Hong-Ou-Mandel (HOM) interferometer…
▽ More
Understanding quantum mechanics within curved spacetime is a key stepping stone towards understanding the nature of spacetime itself. Whilst various theoretical models have been developed,
it is significantly more challenging to carry out actual experiments that probe quantum mechanics in curved spacetime.
By adding Sagnac interferometers into the arms of a Hong-Ou-Mandel (HOM) interferometer that is placed on a mechanically rotating platform, we show that non-inertial motion modifies the symmetry of an entangled biphoton state.
As the platform rotation speed is increased, we observe that HOM interference dips transform into HOM interference peaks. This indicates that the photons pass from perfectly indistinguishable (bosonic behaviour), to perfectly distinguishable (fermionic behavior), therefore demonstrating a mechanism for how spacetime can affect quantum systems. The work is increasingly relevant in the real world as we move towards global satellite quantum communications, and paves the way for further fundamental research that could test the influence of non-inertial motion (and equivalently curved spacetime) on quantum entanglement.
△ Less
Submitted 11 October, 2022;
originally announced October 2022.
-
A plano-convex thick-lens velocity map imaging apparatus for direct, high resolution 3D momentum measurements of photoelectrons with ion time-of-flight coincidence
Authors:
Michael Davino,
Edward McManus,
Nora G. Helming,
Chuan Cheng,
Gonenc Mogol,
Zhanna Rodnova,
Geoffrey Harrison,
Kevin Watson,
Thomas Weinacht,
George N. Gibson,
Tobias Saule,
Carlos Trallero-Herrero
Abstract:
Since its inception, velocity map imaging (VMI) has been a powerful tool for measuring the 2D momentum distribution of photoelectrons generated by strong laser fields. There has been continued interest in expanding it into 3D measurements either through reconstructive or direct methods. Recently much work has been devoted to the latter of these, particularly by relating the electron time-of-flight…
▽ More
Since its inception, velocity map imaging (VMI) has been a powerful tool for measuring the 2D momentum distribution of photoelectrons generated by strong laser fields. There has been continued interest in expanding it into 3D measurements either through reconstructive or direct methods. Recently much work has been devoted to the latter of these, particularly by relating the electron time-of-flight (TOF) to the third momentum component. The technical challenge here is having timing resolution sufficient to resolve structure in the narrow (< 10 ns) electron TOF spread. Here we build upon work in the fields of VMI lens design and 3D VMI measurement by using a plano-convex thick-lens VMI in conjunction with an event-driven camera (TPX3CAM) providing TOF information for high resolution 3D electron momentum measurements. We perform simulations to show that, with the addition of a mesh electrode to the thick-lens VMI geometry, a plano-convex electrostatic field is formed which extends the detectable electron cutoff energy range while retaining high resolution. Further, the thick-lens also extends the electron TOF range which allows for better resolution of the momentum along this axis. We experimentally demonstrate these capabilities by examining above-threshold ionization in Xenon where the apparatus is shown to collect electrons of energy up to $\sim$7 eV with a TOF spread of $\sim$30 ns, both of which are improvements on previous work by factors of $\sim$1.4 and $\sim$3.75 respectively. Finally, the PCTL-VMI is equipped with a coincident ion TOF spectrometer which is shown to effectively extract unique 3D momentum distributions for different ionic species within a gas mixture. These techniques have potential to lend themselves to more advanced measurements, particularly involving systems where the electron momentum distributions possess non-trivial symmetries and require high resolution.
△ Less
Submitted 23 September, 2022;
originally announced September 2022.
-
Measuring Optical Activity with Unpolarised Light: Ghost Polarimetry
Authors:
S. Restuccia,
G. M. Gibson,
L. Cronin,
M. J. Padgett
Abstract:
Quantifying the optical chirality of a sample requires the precise measurement of the rotation of the plane of linear polarisation of the transmitted light. Central to this notion is that the sample needs to be exposed to light of a defined polarisation state. We show that by using a polarisation-entangled photon source we can measure optical activity whilst illuminating a sample with unpolarised…
▽ More
Quantifying the optical chirality of a sample requires the precise measurement of the rotation of the plane of linear polarisation of the transmitted light. Central to this notion is that the sample needs to be exposed to light of a defined polarisation state. We show that by using a polarisation-entangled photon source we can measure optical activity whilst illuminating a sample with unpolarised light. This not only allows for low light measurement of optical activity but also allows for the analysis of samples that would otherwise be perturbed if subject to polarised light.
△ Less
Submitted 17 August, 2022;
originally announced August 2022.
-
Imaging below the camera noise floor with a homodyne microscope
Authors:
Osian Wolley,
Simon Mekhail,
Paul-Antoine Moreau,
Thomas Gregory,
Graham Gibson,
Gerd Leuchs,
Miles J. Padgett
Abstract:
We present a wide-field homodyne imaging system capable of recovering intensity and phase images of an object from a single camera frame at an illumination intensity significantly below the noise floor of the camera. By interfering a weak imaging signal with a much brighter reference beam we are able to image objects in the short-wave infrared down to signal intensity of $\sim$$1.1$ photons per pi…
▽ More
We present a wide-field homodyne imaging system capable of recovering intensity and phase images of an object from a single camera frame at an illumination intensity significantly below the noise floor of the camera. By interfering a weak imaging signal with a much brighter reference beam we are able to image objects in the short-wave infrared down to signal intensity of $\sim$$1.1$ photons per pixel per frame incident on the sensor despite the camera having a noise floor of $\sim$$200$ photons per pixel. At this illumination level we operate under the conditions of a reference beam to probe beam power ratio of $\sim$$300$,$000$:$1$. There is a corresponding $29.2\%$ drop in resolution of the image due to the method implemented. For transmissive objects, in addition to intensity, the approach also images the phase profile of the object. We believe our demonstration could open the way to low-light imaging in domains where low noise cameras are not available, thus vastly extending the range of application for low-light imaging.
△ Less
Submitted 9 August, 2022;
originally announced August 2022.
-
Modular Light Sources for Microscopy and Beyond (ModLight)
Authors:
Graham M Gibson,
Robert Archibald,
Mark Main,
Akhil Kallepalli
Abstract:
Delivering light to an object is one of the key steps in any imaging exercise. Tools such as LEDs and lasers are available to achieve this. These components are integrated into systems such as microscopy, medical imaging, remote sensing, and so many more. Motivated by the need for affordable and open access alternatives that are globally relevant, we share the designs and build instructions for mo…
▽ More
Delivering light to an object is one of the key steps in any imaging exercise. Tools such as LEDs and lasers are available to achieve this. These components are integrated into systems such as microscopy, medical imaging, remote sensing, and so many more. Motivated by the need for affordable and open access alternatives that are globally relevant, we share the designs and build instructions for modular light source devices that use simple, off-the-shelf components. Light emitted by near-infrared, red, green and blue LEDs are combined with a choice of mirrors or X-Cube prisms to deliver collimated beams of light.
△ Less
Submitted 7 June, 2022;
originally announced June 2022.
-
Simulated assessment of light transport through ischaemic skin flaps
Authors:
Mark Main,
Richard JJ Pilkington,
Graham M Gibson,
Akhil Kallepalli
Abstract:
Currently, free flaps and pedicled flaps are assessed for reperfusion in post-operative care using colour, capillary refill, temperature, texture and Doppler signal (if available). While these techniques are effective, they are prone to error due to their qualitative nature. In this research, we explore using different wavelengths of light to quantify the response of ischaemic tissue. The assessme…
▽ More
Currently, free flaps and pedicled flaps are assessed for reperfusion in post-operative care using colour, capillary refill, temperature, texture and Doppler signal (if available). While these techniques are effective, they are prone to error due to their qualitative nature. In this research, we explore using different wavelengths of light to quantify the response of ischaemic tissue. The assessment provides us with indicators that are key to our goal of developing a point-of-care diagnostics device, capable of observing reduced perfusion quantitatively. We set up a detailed optical model of the layers of the skin. The layers of the model are given appropriate optical properties of the tissue, with due consideration of melanin and haemoglobin concentrations. We simulate 24 models of healthy, perfused tissue and perfusion-deprived tissue to assess the responses when illuminated with visible and near-infrared wavelengths of light. In addition to detailed fluence maps of photon propagation, we propose a simple mathematical model to assess the differential propagation of photons in tissue; the optical reperfusion factor (ORF). Our results show clear advantages of using light at longer wavelengths (red, near-infrared) and the inferences drawn from the simulations hold significant clinical relevance. The simulated scenarios and results consolidate the belief of a multi-wavelength, point-of-care diagnostics device and inform its design for quantifying blood flow in transplanted tissue. The modelling approach is applicable beyond the current research, wherein other medical conditions that can be mathematically represented in the skin can be investigated. Through these, additional inferences and approaches to other point-of-care devices can be realised.
△ Less
Submitted 14 April, 2022;
originally announced April 2022.
-
Amplification of waves from a rotating body
Authors:
M. Cromb,
G. M. Gibson,
E. Toninelli,
M. J. Padgett,
E. M. Wright,
D. Faccio
Abstract:
In 1971 Zel'dovich predicted that quantum fluctuations and classical waves reflected from a rotating absorbing cylinder will gain energy and be amplified. This key conceptual step towards the understanding that black holes may also amplify quantum fluctuations, has not been verified experimentally due to the challenging experimental requirements on the cylinder rotation rate that must be larger th…
▽ More
In 1971 Zel'dovich predicted that quantum fluctuations and classical waves reflected from a rotating absorbing cylinder will gain energy and be amplified. This key conceptual step towards the understanding that black holes may also amplify quantum fluctuations, has not been verified experimentally due to the challenging experimental requirements on the cylinder rotation rate that must be larger than the incoming wave frequency. Here we experimentally demonstrate that these conditions can be satisfied with acoustic waves. We show that low-frequency acoustic modes with orbital angular momentum are transmitted through an absorbing rotating disk and amplified by up to 30% or more when the disk rotation rate satisfies the Zel'dovich condition. These experiments address an outstanding problem in fundamental physics and have implications for future research into the extraction of energy from rotating systems.
△ Less
Submitted 4 May, 2020;
originally announced May 2020.
-
What Caging Force Cells Feel in 3D Hydrogels: A Rheological Perspective
Authors:
Giuseppe Ciccone,
Oana Dobre,
Graham M. Gibson,
Massimo Vassalli,
Manuel Salmeron-Sanchez,
Manlio Tassieri
Abstract:
It is established that the mechanical properties of hydrogels control the fate of (stem) cells. However, despite its importance, a one-to-one correspondence between gels' stiffness and cell behaviour is still missing from literature. In this work, the viscoelastic properties of Poly(ethylene-glycol) (PEG)-based hydrogels - broadly used in 3D cell cultures and whose mechanical properties can be tun…
▽ More
It is established that the mechanical properties of hydrogels control the fate of (stem) cells. However, despite its importance, a one-to-one correspondence between gels' stiffness and cell behaviour is still missing from literature. In this work, the viscoelastic properties of Poly(ethylene-glycol) (PEG)-based hydrogels - broadly used in 3D cell cultures and whose mechanical properties can be tuned to resemble those of different biological tissues - are investigated by means of rheological measurements performed at different length scales. When compared with literature values, the outcomes of this work reveal that conventional bulk rheology measurements may overestimate the stiffness of hydrogels by up to an order of magnitude. It is demonstrated that this apparent stiffening is caused by an induced 'tensional state' of the gel network, due to the application of a compressional normal force during measurements. Moreover, it is shown that the actual stiffness of the hydrogels is instead accurately determined by means of passive-video-particle-tracking (PVPT) microrheology measurements, which are inherently performed at cells length scales and in absence of any externally applied force. These results underpin a methodology for measuring the linear viscoelastic properties of hydrogels that are representative of the mechanical constraints felt by cells in 3D hydrogel cultures.
△ Less
Submitted 5 January, 2020;
originally announced January 2020.
-
Revealing and concealing entanglement with non-inertial motion
Authors:
Marko Toroš,
Sara Restuccia,
Graham M. Gibson,
Marion Cromb,
Hendrik Ulbricht,
Miles Padgett,
Daniele Faccio
Abstract:
Photon interference and bunching are widely studied quantum effects that have also been proposed for high precision measurements. Here we construct a theoretical description of photon-interferometry on rotating platforms, specifically exploring the relation between non-inertial motion, relativity, and quantum mechanics. On the basis of this, we then propose an experiment where photon entanglement…
▽ More
Photon interference and bunching are widely studied quantum effects that have also been proposed for high precision measurements. Here we construct a theoretical description of photon-interferometry on rotating platforms, specifically exploring the relation between non-inertial motion, relativity, and quantum mechanics. On the basis of this, we then propose an experiment where photon entanglement can be revealed or concealed solely by controlling the rotational motion of an interferometer, thus providing a route towards studies at the boundary between quantum mechanics and relativity.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
A Gigapixel Computational Light-Field Camera
Authors:
Thomas Gregory,
Matthew P. Edgar,
Graham M. Gibson,
Paul-Antoine Moreau
Abstract:
Light-field cameras allow the acquisition of both the spatial and angular components of the light. This has a wide range of applications from image refocusing to 3D reconstruction of a scene. The conventional way to perform such acquisitions leads to a strong spatio-angular resolution limit. Here we propose a computational version of the light-field camera. We perform a one gigapixel photo-realist…
▽ More
Light-field cameras allow the acquisition of both the spatial and angular components of the light. This has a wide range of applications from image refocusing to 3D reconstruction of a scene. The conventional way to perform such acquisitions leads to a strong spatio-angular resolution limit. Here we propose a computational version of the light-field camera. We perform a one gigapixel photo-realistic diffraction limited light-field acquisition, that would require the use of a one gigapixel sensor were the acquisition to be performed with a conventional light-field camera. This result is mostly limited by the total acquisition time, as our system could in principle allow $\sim$Terapixel reconstructions to be achieved. The reported result presents many potential advantages, such as the possibility to perform large depth of field light-field acquisitions, realistic refocusing along a very wide range of depths, very high dimensional super-resolved image acquisitions, and large depth of field 3D reconstructions.
△ Less
Submitted 18 October, 2019;
originally announced October 2019.
-
Adaptive foveated single-pixel imaging with dynamic super-sampling
Authors:
David B. Phillips,
Ming-Jie Sun,
Jonathan M. Taylor,
Matthew P. Edgar,
Stephen M. Barnett,
Graham G. Gibson,
Miles J. Padgett
Abstract:
As an alternative to conventional multi-pixel cameras, single-pixel cameras enable images to be recorded using a single detector that measures the correlations between the scene and a set of patterns. However, to fully sample a scene in this way requires at least the same number of correlation measurements as there are pixels in the reconstructed image. Therefore single-pixel imaging systems typic…
▽ More
As an alternative to conventional multi-pixel cameras, single-pixel cameras enable images to be recorded using a single detector that measures the correlations between the scene and a set of patterns. However, to fully sample a scene in this way requires at least the same number of correlation measurements as there are pixels in the reconstructed image. Therefore single-pixel imaging systems typically exhibit low frame-rates. To mitigate this, a range of compressive sensing techniques have been developed which rely on a priori knowledge of the scene to reconstruct images from an under-sampled set of measurements. In this work we take a different approach and adopt a strategy inspired by the foveated vision systems found in the animal kingdom - a framework that exploits the spatio-temporal redundancy present in many dynamic scenes. In our single-pixel imaging system a high-resolution foveal region follows motion within the scene, but unlike a simple zoom, every frame delivers new spatial information from across the entire field-of-view. Using this approach we demonstrate a four-fold reduction in the time taken to record the detail of rapidly evolving features, whilst simultaneously accumulating detail of more slowly evolving regions over several consecutive frames. This tiered super-sampling technique enables the reconstruction of video streams in which both the resolution and the effective exposure-time spatially vary and adapt dynamically in response to the evolution of the scene. The methods described here can complement existing compressive sensing approaches and may be applied to enhance a variety of computational imagers that rely on sequential correlation measurements.
△ Less
Submitted 27 July, 2016;
originally announced July 2016.
-
Single-pixel 3D imaging with time-based depth resolution
Authors:
Ming-Jie Sun,
Matthew. P. Edgar,
Graham M. Gibson,
Baoqing Sun,
Neal Radwell,
Robert Lamb,
Miles J. Padgett
Abstract:
Time-of-flight three dimensional imaging is an important tool for many applications, such as object recognition and remote sensing. Unlike conventional imaging approach using pixelated detector array, single-pixel imaging based on projected patterns, such as Hadamard patterns, utilises an alternative strategy to acquire information with sampling basis. Here we show a modified single-pixel camera u…
▽ More
Time-of-flight three dimensional imaging is an important tool for many applications, such as object recognition and remote sensing. Unlike conventional imaging approach using pixelated detector array, single-pixel imaging based on projected patterns, such as Hadamard patterns, utilises an alternative strategy to acquire information with sampling basis. Here we show a modified single-pixel camera using a pulsed illumination source and a high-speed photodiode, capable of reconstructing 128x128 pixel resolution 3D scenes to an accuracy of ~3 mm at a range of ~5 m. Furthermore, we demonstrate continuous real-time 3D video with a frame-rate up to 12 Hz. The simplicity of the system hardware could enable low-cost 3D imaging devices for precision ranging at wavelengths beyond the visible spectrum.
△ Less
Submitted 2 March, 2016;
originally announced March 2016.
-
Infrared single-pixel imaging utilising microscanning
Authors:
Ming-Jie Sun,
Matthew P. Edgar,
David B. Phillips,
Graham M. Gibson,
Miles J. Padgett
Abstract:
Since the invention of digital cameras there has been a concerted drive towards detector arrays with higher spatial resolution. Microscanning is a technique that provides a final higher resolution image by combining multiple images of a lower resolution. Each of these low resolution images is subject to a sub-pixel sized lateral displacement. In this work we apply the microscanning approach to an…
▽ More
Since the invention of digital cameras there has been a concerted drive towards detector arrays with higher spatial resolution. Microscanning is a technique that provides a final higher resolution image by combining multiple images of a lower resolution. Each of these low resolution images is subject to a sub-pixel sized lateral displacement. In this work we apply the microscanning approach to an infrared single-pixel camera. For the same final resolution and measurement resource, we show that microscanning improves the signal-to-noise ratio (SNR) of reconstructed images by approximately 50%. In addition, this strategy also provides access to a stream of low-resolution 'preview' images throughout each high-resolution acquisition. Our work demonstrates an additional degree of flexibility in the trade-off between SNR and spatial resolution in single-pixel imaging techniques.
△ Less
Submitted 9 November, 2015;
originally announced November 2015.
-
Non-invasive, near-field terahertz imaging of hidden objects using a single pixel detector
Authors:
R. I. Stantchev,
B. Sun,
S. M. Hornett,
P. A. Hobson,
G. M. Gibson,
M. J. Padgett,
E. Hendry
Abstract:
Terahertz (THz) imaging has the ability to see through otherwise opaque materials. However, due to the long wavelengths of THz radiation (λ=300μm at 1THz), far-field THz imaging techniques are heavily outperformed by optical imaging in regards to the obtained resolution. In this work we demonstrate near-field THz imaging with a single-pixel detector. We project a time-varying optical mask onto a s…
▽ More
Terahertz (THz) imaging has the ability to see through otherwise opaque materials. However, due to the long wavelengths of THz radiation (λ=300μm at 1THz), far-field THz imaging techniques are heavily outperformed by optical imaging in regards to the obtained resolution. In this work we demonstrate near-field THz imaging with a single-pixel detector. We project a time-varying optical mask onto a silicon wafer which is used to spatially modulate a pulse of THz radiation. The far-field transmission corresponding to each mask is recorded by a single element detector and this data is used to reconstruct the image of an object placed on the far side of the silicon wafer. We demonstrate a proof of principal application where we image a printed circuit board on the underside of a 115μm thick silicon wafer with ~100μm (λ/4) resolution. With subwavelength resolution and the inherent sensitivity to local conductivity provided by the THz probe frequencies, we show that it is possible to detect fissures in the circuitry wiring of a few microns in size. Imaging systems of this type could have other uses where non-invasive measurement or imaging of concealed structures with high resolution is necessary, such as in semiconductor manufacturing or in bio-imaging.
△ Less
Submitted 18 February, 2016; v1 submitted 10 September, 2015;
originally announced September 2015.
-
Inference and Optimal Design for Nearest-Neighbour Interaction Models
Authors:
Andrei Iu. Bejan,
Gavin J. Gibson,
Stan Zachary
Abstract:
We consider problems of Bayesian inference for a spatial epidemic on a graph, where the final state of the epidemic corresponds to bond percolation, and where only the set or number of finally infected sites is observed. We develop appropriate Markov chain Monte Carlo algorithms, demonstrating their effectiveness, and we study problems of optimal experimental design. In particular, we demonstrate…
▽ More
We consider problems of Bayesian inference for a spatial epidemic on a graph, where the final state of the epidemic corresponds to bond percolation, and where only the set or number of finally infected sites is observed. We develop appropriate Markov chain Monte Carlo algorithms, demonstrating their effectiveness, and we study problems of optimal experimental design. In particular, we demonstrate that for lattice-based processes an experiment on a sparsified lattice can yield more information on model parameters than one conducted on a complete lattice. We also prove some probabilistic results about the behaviour of estimators associated with large infected clusters.
△ Less
Submitted 14 August, 2010;
originally announced August 2010.
-
Optical tweezers: wideband microrheology
Authors:
Daryl Preece,
Rebecca Warren,
Manlio Tassieri,
R. M. L. Evans,
Graham M. Gibson,
Miles J. Padgett,
Jonathan M. Cooper
Abstract:
Microrheology is a branch of rheology having the same principles as conventional bulk rheology, but working on micron length scales and micro-litre volumes.
Optical tweezers have been successfully used with Newtonian fluids for rheological purposes such as determining fluid viscosity. Conversely, when optical tweezers are used to measure the viscoelastic properties of complex fluids the results a…
▽ More
Microrheology is a branch of rheology having the same principles as conventional bulk rheology, but working on micron length scales and micro-litre volumes.
Optical tweezers have been successfully used with Newtonian fluids for rheological purposes such as determining fluid viscosity. Conversely, when optical tweezers are used to measure the viscoelastic properties of complex fluids the results are either limited to the material's high-frequency response, discarding important information related to the low-frequency behavior, or they are supplemented by low-frequency measurements performed with different techniques, often without presenting an overlapping region of clear agreement between the sets of results. We present a simple experimental procedure to perform microrheological measurements over the widest frequency range possible with optical tweezers. A generalised Langevin equation is used to relate the frequency-dependent moduli of the complex fluid to the time-dependent trajectory of a probe particle as it flips between two optical traps that alternately switch on and off.
△ Less
Submitted 9 May, 2010;
originally announced May 2010.
-
Tunneling Ionization Rates from Arbitrary Potential Wells
Authors:
G. N. Gibson,
G. Dunne,
K. J. Bergquist
Abstract:
We present a practical numerical technique for calculating tunneling ionization rates from arbitrary 1-D potential wells in the presence of a linear external potential by determining the widths of the resonances in the spectral density, rho(E), adiabatically connected to the field-free bound states. While this technique applies to more general external potentials, we focus on the ionization of e…
▽ More
We present a practical numerical technique for calculating tunneling ionization rates from arbitrary 1-D potential wells in the presence of a linear external potential by determining the widths of the resonances in the spectral density, rho(E), adiabatically connected to the field-free bound states. While this technique applies to more general external potentials, we focus on the ionization of electrons from atoms and molecules by DC electric fields, as this has an important and immediate impact on the understanding of the multiphoton ionization of molecules in strong laser fields.
△ Less
Submitted 21 October, 1998;
originally announced October 1998.