-
Sub-keV Electron Recoil Calibration for Cryogenic Detectors using a Novel X-ray Fluorescence Source
Authors:
H. Abele,
G. Angloher,
B. Arnold,
M. Atzori Corona,
A. Bento,
E. Bossio,
J. Burkhart,
F. Cappella,
M. Cappelli,
N. Casali,
R. Cerulli,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
S. Dorer,
A. Erhart,
M. Friedl,
S. Fichtinger,
V. M. Ghete,
M. Giammei,
C. Goupy,
D. Hauff,
F. Jeanneau,
E. Jericha,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Calibration of cryogenic detectors with energy thresholds below 100 eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting monoene…
▽ More
Calibration of cryogenic detectors with energy thresholds below 100 eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting monoenergetic X-rays from 677 eV to 6.5 keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 gram CaWO$_4$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in detectors based on transition edge sensors (TES).
△ Less
Submitted 23 May, 2025;
originally announced May 2025.
-
Decoupling Pulse Tube Vibrations from a Dry Dilution Refrigerator at milli-Kelvin Temperatures
Authors:
The NUCLEUS collaboration,
A. Wex,
J. Rothe,
L. Peters,
H. Abele,
G. Angloher,
B. Arnold,
M. Atzori Corona,
A. Bento,
E. Bossio,
J. Burkhart,
L. Canonica,
F. Cappella,
M. Cappelli,
N. Casali,
R. Cerulli,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
A. Erhart,
M. Friedl,
S. Fichtinger,
A. Garai
, et al. (42 additional authors not shown)
Abstract:
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a…
▽ More
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low $(6.22 \pm 0.07)$ eV baseline resolution on a gram-scale CaWO$_4$ cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.
△ Less
Submitted 7 April, 2025; v1 submitted 8 January, 2025;
originally announced January 2025.
-
Low-energy spectrum of the BULLKID detector array operated on surface
Authors:
D. Delicato,
A. Ahmad,
L. Bandiera,
M. Calvo,
M. Cappelli,
G. Del Castello,
M. del Gallo Roccagiovine,
M. Giammei,
V. Guidi,
D. Maiello,
V. Pettinacci,
M. Romagnoni,
M. Tamisari,
A. Cruciani,
A. Mazzolari,
A. Monfardini,
M. Vignati
Abstract:
We present the first continuous operation in a surface lab of BULLKID, a detector for searches of light Dark Matter and precision measurements of the coherent and elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The data presented focusses on one of the central elements of…
▽ More
We present the first continuous operation in a surface lab of BULLKID, a detector for searches of light Dark Matter and precision measurements of the coherent and elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The data presented focusses on one of the central elements of the array and on its surrounding elements used as veto. The energy spectrum resulting from an exposure of 39 hours to ambient backgrounds, obtained without radiation shields, is flat at the level of $(2.0\pm0.1\,{\rm stat.}\pm0.2\,{\rm syst.})\times10^6$ counts / keV kg days down to the energy threshold of $160\pm13$ eV. The data analysis demonstrates the unique capability of rejecting backgrounds generated from interactions in other sites of the array, stemming from the segmented and monolithic structure of the detector.
△ Less
Submitted 17 April, 2024; v1 submitted 28 August, 2023;
originally announced August 2023.
-
BULLKID: Monolithic array of particle absorbers sensed by Kinetic Inductance Detectors
Authors:
A. Cruciani,
L. Bandiera,
M. Calvo,
N. Casali,
I. Colantoni,
G. Del Castello,
M. del Gallo Roccagiovine,
D. Delicato,
M. Giammei,
V. Guidi,
J. Goupy,
V. Pettinacci,
G. Pettinari,
M. Romagnoni,
M. Tamisari,
A. Mazzolari,
A. Monfardini,
M. Vignati
Abstract:
We introduce BULLKID, an innovative phonon detector consisting of an array of dices acting as particle absorbers sensed by multiplexed Kinetic Inductance Detectors (KIDs). The dices are carved in a thick crystalline wafer and form a monolithic structure. The carvings leave a thin common disk intact in the wafer, acting both as holder for the dices and as substrate for the KID lithography. The prot…
▽ More
We introduce BULLKID, an innovative phonon detector consisting of an array of dices acting as particle absorbers sensed by multiplexed Kinetic Inductance Detectors (KIDs). The dices are carved in a thick crystalline wafer and form a monolithic structure. The carvings leave a thin common disk intact in the wafer, acting both as holder for the dices and as substrate for the KID lithography. The prototype presented consists of an array of 64 dices of 5.4x5.4x5 mm$^3$ carved in a 3" diameter, 5 mm thick silicon wafer, with a common disk 0.5 mm thick hosting a 60 nm patterned aluminum layer. The resulting array is highly segmented but avoids the use of dedicated holding structures for each unit. Despite the fact that the uniformity of the KID electrical response across the array needs optimization, the operation of 8 units with similar features shows, on average, a baseline energy resolution of $26\pm7$ eV. This makes it a suitable detector for low-energy processes such as direct interactions of dark matter and coherent elastic neutrino-nucleus scattering.
△ Less
Submitted 29 September, 2022;
originally announced September 2022.