-
Development of wide range photon detection system for muonic X-ray spectroscopy
Authors:
R. Mizuno,
M. Niikura,
T. Y. Saito,
T. Matsuzaki,
H. Sakurai,
A. Amato,
S. Asari,
S. Biswas,
I. Chiu,
L. Gerchow,
Z. Guguchia,
G. Janka,
K. Ninomiya,
N. Ritjoho,
A. Sato,
K. von Schoeler,
D. Tomono,
K. Terada,
C. Wang
Abstract:
We have developed a photon detection system for muonic X-ray spectroscopy. The detector system consists of high-purity germanium detectors with BGO Compton suppressors. The signals from the detectors are readout with a digital acquisition system. The absolute energy accuracy, energy and timing resolutions, photo-peak efficiency, the performance of the Compton suppressor, and high count rate durabi…
▽ More
We have developed a photon detection system for muonic X-ray spectroscopy. The detector system consists of high-purity germanium detectors with BGO Compton suppressors. The signals from the detectors are readout with a digital acquisition system. The absolute energy accuracy, energy and timing resolutions, photo-peak efficiency, the performance of the Compton suppressor, and high count rate durability are studied with standard $γ$-ray sources and in-beam experiment using $^{27}\mathrm{Al}(p, γ){}^{28}\mathrm{Si}$ resonance reaction. The detection system was demonstrated at Paul Scherrer Institute. A calibration method for a photon detector at a muon facility using muonic X-rays of $^{197}$Au and $^{209}$Bi is proposed.
△ Less
Submitted 18 December, 2023; v1 submitted 31 August, 2023;
originally announced September 2023.
-
GermanIum Array for Non-destructive Testing (GIANT) setup for Muon Induced X-ray Emission (MIXE) at the Paul Scherrer Institute
Authors:
Lars Gerchow,
Sayani Biswas,
Gianluca Janka,
Carlos Vigo,
Andreas Knecht,
Stergiani Marina Vogiatzi,
Narongrit Ritjoho,
Thomas Prokscha,
Hubertus Luetkens,
Alex Amato
Abstract:
The usage of muonic X-rays to study elemental properties like nuclear radii ranges back to the seventies. This triggered the pioneering work at the Paul Scherrer Institute (PSI), during the eighties, on the Muon Induced X-ray Emission (MIXE) technique for a non-destructive assessment of elemental compositions. In the recent years, this method has seen a rebirth, improvement and adoption at most mu…
▽ More
The usage of muonic X-rays to study elemental properties like nuclear radii ranges back to the seventies. This triggered the pioneering work at the Paul Scherrer Institute (PSI), during the eighties, on the Muon Induced X-ray Emission (MIXE) technique for a non-destructive assessment of elemental compositions. In the recent years, this method has seen a rebirth, improvement and adoption at most muon facilities around the world. Hereby, the PSI offers unique capabilities with its high-rate continuous muon beam at the Swiss Muon Source (S$μ$S). We report here the decision making, construction and commissioning of a dedicated MIXE spectrometer at PSI, the GermanIum Array for Non-destructive Testing (GIANT) setup. Multiple campaigns highlighted the outstanding capabilities of MIXE at PSI, e.g. resolving down to 1 at% elemental concentrations with as little as 1 h data taking, measuring isotopic ratios for elements from iron to lead, and characterizing gamma rays induced by muon nuclear capture. On-target beamspots were characterized with a dedicated charged particle tracker to be 22.06$\pm$0.18 and 14.45$\pm$0.06 mm for 25 and 45 MeV/c, respectively. Advanced analysis of the High Purity Germanium (HPGe) signals further allows to improve energy and timing resolutions to ~1 keV and 20 ns at 1 MeV, respectively. Within the GIANT setup, an average detector has a photopeak efficiency of $\overline{ε_E}$ =0.11% and an energy resolution of $\overline{σ_E}$ = 0.8 keV at E=1000 keV. The overall performance of the GIANT setup at S$μ$S allowed to start a rich user program with archaeological samples, Li-ion battery research, and collaboration with industry. Future improvements will include a simulation based analysis and a higher degree of automation, e.g. automatic scans of a series of muon momenta and automatic sample changing.
△ Less
Submitted 28 October, 2022;
originally announced October 2022.
-
Room-temperature emission of muonium from aerogel and zeolite targets
Authors:
A. Antognini,
P. Crivelli,
L. Gerchow,
T. D. Hume,
K. Kirch,
A. Knecht,
J. Nuber,
A. Papa,
N. Ritjoho,
M. Sakurai,
A. Soter,
D. Taqqu,
S. M. Vogiatzi,
J. Zhang,
L. Ziegler
Abstract:
A low-emittance, high-intensity atomic beam of muonium ($\mathrm{M}=μ^+ + \mathrm{e}^-$) using superfluid helium as muon-to-muonium converter is being developed at the Paul Scherrer Institute (PSI). This beam could advance laser spectroscopy of muonium and allow the first atomic interferometry experiments for the direct observation of the M gravitational interaction. In this paper, we describe the…
▽ More
A low-emittance, high-intensity atomic beam of muonium ($\mathrm{M}=μ^+ + \mathrm{e}^-$) using superfluid helium as muon-to-muonium converter is being developed at the Paul Scherrer Institute (PSI). This beam could advance laser spectroscopy of muonium and allow the first atomic interferometry experiments for the direct observation of the M gravitational interaction. In this paper, we describe the development of compact detection schemes which resulted in the background-suppressed observation of atomic muonium in vacuum, and can be adapted for cryogenic measurements. Using these setups, we compared the emission characteristics of various muonium production targets using low momentum ($p_μ = 11$-$13~$MeV/c) muons, and observed muonium emission from zeolite targets into vacuum for the first time. For a specific laser-ablated aerogel target, we determined a muon-to-vacuum-muonium conversion efficiency of $7.23 \pm 0.05 \text{(stat)} ^{+1.06}_{-0.76}\text{(sys)}\,\text{%}$, assuming thermal emission of muonium. Moreover, we investigated muonium-helium collisions and from it we determined an upper temperature limit of 0.3 K for the superfluid helium converter.
△ Less
Submitted 24 August, 2022;
originally announced August 2022.
-
Characterization of a continuous muon source for the Muon-Induced X-ray Emission (MIXE) Technique
Authors:
Sayani Biswas,
Lars Gerchow,
Hubertus Luetkens,
Thomas Prokscha,
Aldo Antognini,
Niklaus Berger,
Thomas Elias Cocolios,
Rugard Dressler,
Paul Indelicato,
Klaus Jungmann,
Klaus Kirch,
Andreas Knecht,
Angela Papa,
Randolf Pohl,
Maxim Pospelov,
Elisa Rapisarda,
Peter Reiter,
Narongrit Ritjoho,
Stephanie Roccia,
Nathal Severijns,
Alexander Skawran,
Stergiani Marina Vogiatzi,
Frederik Wauters,
Lorenz Willmann,
Alex Amato
Abstract:
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon-Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the avail…
▽ More
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon-Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the availability of high intensity muon beams. We report here a study conducted at the Paul Scherrer Institute (PSI). It demonstrates that the absence of any beam time-structure leads to low pile-up events and a high signal-to-noise ratio (SNR) with less than one hour acquisition time per sample or data point. This performance creates the perspective to open this technique to a wider audience for the routine investigation of non-destructive and depth-sensitive elemental compositions, for example in rare and precious samples. Using a hetero-structured sample of known elements and thicknesses, we successfully detected the characteristic muonic X-rays, emitted during the capture of a negative muon by an atom, and the gamma-rays resulting from the nuclear capture of the muon, characterizing the capabilities of MIXE at PSI. This sample emphasizes the quality of a continuous beam, and the exceptional SNR at high rates. Such sensitivity will enable totally new statistically intense aspects in the field of MIXE, e.g. elemental 3D-tomography and chemical analysis. Therefore, we are currently advancing our proof-of-concept experiments with the goal of creating a full fledged permanently operated user station to make MIXE available to the wider scientific community as well as industry.
△ Less
Submitted 8 February, 2022;
originally announced February 2022.
-
Intense beam of metastable Muonium
Authors:
G. Janka,
B. Ohayon,
Z. Burkley,
L. Gerchow,
N. Kuroda,
X. Ni,
R. Nishi,
Z. Salman,
A. Suter,
M. Tuzi,
C. Vigo,
T. Prokscha,
P. Crivelli
Abstract:
Precision spectroscopy of the Muonium Lamb shift and fine structure requires a robust source of 2S Muonium. To date, the beam-foil technique is the only demonstrated method for creating such a beam in vacuum. Previous experiments using this technique were statistics limited, and new measurements would benefit tremendously from the efficient 2S production at a low energy muon ($<20$ keV) facility.…
▽ More
Precision spectroscopy of the Muonium Lamb shift and fine structure requires a robust source of 2S Muonium. To date, the beam-foil technique is the only demonstrated method for creating such a beam in vacuum. Previous experiments using this technique were statistics limited, and new measurements would benefit tremendously from the efficient 2S production at a low energy muon ($<20$ keV) facility. Such a source of abundant low energy $\mathrm{μ^+}$ has only become available in recent years, e.g. at the Low-Energy Muon beamline at the Paul Scherrer Institute. Using this source, we report on the successful creation of an intense, directed beam of metastable Muonium. We find that even though the theoretical Muonium fraction is maximal in the low energy range of $2-5$ keV, scattering by the foil and transport characteristics of the beamline favor slightly higher $\mathrm{μ^+}$ energies of $7-10$ keV. We estimate that an event detection rate of a few events per second for a future Lamb shift measurement is feasible, enabling an increase in precision by two orders of magnitude over previous determinations.
△ Less
Submitted 6 May, 2020; v1 submitted 5 April, 2020;
originally announced April 2020.
-
New bounds from positronium decays on massless mirror dark photons
Authors:
C. Vigo,
L. Gerchow,
B. Radics,
M. Raaijmakers,
A. Rubbia,
P. Crivelli
Abstract:
We present the results of a search for a hidden mirror sector in positronium decays with a sensitivity comparable with the bounds set by the prediction of the primordial He$^{4}$ abundance from Big Bang Nucleosynthesis. No excess of events compatible with decays into the dark sector is observed resulting in an upper limit for the branching ratio of this process of $4.0\times10^{-5}$ ($90\%$ C.L.).…
▽ More
We present the results of a search for a hidden mirror sector in positronium decays with a sensitivity comparable with the bounds set by the prediction of the primordial He$^{4}$ abundance from Big Bang Nucleosynthesis. No excess of events compatible with decays into the dark sector is observed resulting in an upper limit for the branching ratio of this process of $4.0\times10^{-5}$ ($90\%$ C.L.). This is an order of magnitude more stringent than the current existing laboratory bounds and it constraints the mixing strength of ordinary photons to dark mirror photons at a level of $\varepsilon<5.8\times 10^{-8}$.
△ Less
Submitted 2 March, 2020; v1 submitted 22 May, 2019;
originally announced May 2019.
-
A new approach for the ortho-positronium lifetime determination in a vacuum cavity
Authors:
C. Vigo,
M. Raajimakers,
L. Gerchow,
B. Radics,
A. Rubbia,
P. Crivelli
Abstract:
Currently, the experimental uncertainty for the determination of the ortho-positronium (o-Ps) decay rate is at 150 ppm precision; this is two orders of magnitude lower than the theoretical one, at 1 ppm level. Here we propose a new proof of concept experiment aiming for an accuracy of 100 ppm to be able to test the second-order correction in the calculations, which is…
▽ More
Currently, the experimental uncertainty for the determination of the ortho-positronium (o-Ps) decay rate is at 150 ppm precision; this is two orders of magnitude lower than the theoretical one, at 1 ppm level. Here we propose a new proof of concept experiment aiming for an accuracy of 100 ppm to be able to test the second-order correction in the calculations, which is $\simeq 45\left(\fracαπ\right)^2\approx 200$ ppm. The improvement relies on a new technique to confine the o-Ps in a vacuum cavity. Moreover, a new method was developed to subtract the time dependent pick-off annihilation rate of the fast backscattered positronium from the o-Ps decay rate prior to fitting the distribution. Therefore, this measurement will be free from the systematic errors present in the previous experiments. The same experimental setup developed for our recent search for invisible decay of ortho-positronium is being used. The precision will be limited by the statistical uncertainty, thus, if the expectations are fulfilled, this experiment could pave the way to reach the ultimate accuracy of a few ppm level to confirm or confront directly the higher order QED corrections. This will provide a sensitive test for new physics, e.g. a discrepancy between theoretical prediction and measurements could hint the existence of an hidden sector which is a possible dark matter candidate.
△ Less
Submitted 16 May, 2018;
originally announced May 2018.
-
First search for invisible decays of ortho-positronium confined in a vacuum cavity
Authors:
C. Vigo,
L. Gerchow,
L. Liszkay,
A. Rubbia,
P. Crivelli
Abstract:
The experimental setup and results of the first search for invisible decays of ortho-positronium (o-Ps) confined in a vacuum cavity are reported. No evidence of invisible decays at a level $\text{Br}\left(\text{o-Ps}\to\text{invisible}\right) < 5.9\times 10^{-4}$ (90% C. L.) was found. This decay channel is predicted in Hidden Sector models such as the Mirror Matter (MM), which could be a candidat…
▽ More
The experimental setup and results of the first search for invisible decays of ortho-positronium (o-Ps) confined in a vacuum cavity are reported. No evidence of invisible decays at a level $\text{Br}\left(\text{o-Ps}\to\text{invisible}\right) < 5.9\times 10^{-4}$ (90% C. L.) was found. This decay channel is predicted in Hidden Sector models such as the Mirror Matter (MM), which could be a candidate for Dark Matter. Analyzed within the MM context, this result provides an upper limit on the kinetic mixing strength between ordinary and mirror photons of $ε< 3.1 \times 10^{-7}$ (90% C. L.). This limit was obtained for the first time in vacuum free of systematic effects due to collisions with matter.
△ Less
Submitted 19 March, 2018; v1 submitted 15 March, 2018;
originally announced March 2018.
-
High efficiency cyclotron trap assisted positron moderator
Authors:
L. Gerchow,
D. A. Cooke,
S. Braccini,
M. Döbeli,
K. Kirch,
U. Köster,
A. Müller,
N. P. Van Der Meulen,
C. Vermeulen,
A. Rubbia,
P. Crivelli
Abstract:
We report the realisation of a cyclotron trap assisted positron tungsten moderator for the conversion of positrons with a broad keV- few MeV energy spectrum to a mono-energetic eV beam with an efficiency of 1.8(2)% defined as the ratio of the slow positrons divided by the $β^+$ activity of the radioactive source. This is an improvement of almost two orders of magnitude compared to the state of the…
▽ More
We report the realisation of a cyclotron trap assisted positron tungsten moderator for the conversion of positrons with a broad keV- few MeV energy spectrum to a mono-energetic eV beam with an efficiency of 1.8(2)% defined as the ratio of the slow positrons divided by the $β^+$ activity of the radioactive source. This is an improvement of almost two orders of magnitude compared to the state of the art of tungsten moderators. The simulation validated with this measurement suggests that using an optimised setup even higher efficiencies are achievable.
△ Less
Submitted 17 March, 2017;
originally announced March 2017.
-
Positronium in MOFs: the Atom out of the box
Authors:
P. Crivelli,
D. Cooke,
B. Barbiellini,
B. L. Brown,
J. I. Feldblyum,
P. Guo,
D. W. Gidley,
L. Gerchow,
A. J. Matzger
Abstract:
Recently, evidence for positronium (Ps) in a Bloch state in self-assembled metal--organic frameworks (MOFs) has been reported [Dutta et al., Phys. Rev. Lett. 110, 197403 (2013)]. In this paper, we study Ps emission into vacuum from four different MOFs crystals: MOF-5, IRMOF-8, FMA and IRMOF-20. Our measurements of Ps yield and emission energy into vacuum provide definitive evidence of Ps delocaliz…
▽ More
Recently, evidence for positronium (Ps) in a Bloch state in self-assembled metal--organic frameworks (MOFs) has been reported [Dutta et al., Phys. Rev. Lett. 110, 197403 (2013)]. In this paper, we study Ps emission into vacuum from four different MOFs crystals: MOF-5, IRMOF-8, FMA and IRMOF-20. Our measurements of Ps yield and emission energy into vacuum provide definitive evidence of Ps delocalization. We determine with a different technique Ps diffusion lengths in agreement with the recently published results. Furthermore, we measure that a fraction of the Ps is emitted into vacuum with a distinctly smaller energy than what one would expect for Ps localized in the MOFs' cells. We show that a calculation assuming Ps delocalized in a Kronig--Penney potential reproduces the measured Ps emission energy.
△ Less
Submitted 4 October, 2013; v1 submitted 25 September, 2013;
originally announced September 2013.