-
The GRIFFIN Facility for Decay-Spectroscopy Studies at TRIUMF-ISAC
Authors:
A. B. Garnsworthy,
C. E. Svensson,
M. Bowry,
R. Dunlop,
A. D. MacLean,
B. Olaizola,
J. K. Smith,
F. A. Ali,
C. Andreoiu,
J. E. Ash,
W. H. Ashfield,
G. C. Ball,
T. Ballast,
C. Bartlett,
Z. Beadle,
P. C. Bender,
N. Bernier,
S. S. Bhattacharjee,
H. Bidaman,
V. Bildstein,
D. Bishop,
P. Boubel,
R. Braid,
D. Brennan,
T. Bruhn
, et al. (79 additional authors not shown)
Abstract:
Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new high-efficiency $γ$-ray spectrometer designed for use in decay spectroscopy experiments with low-energy radioactive ion beams provided by TRIUMF's Isotope Separator and Accelerator (ISAC-I) facility. GRIFFIN is composed of sixteen Compton-suppressed large-volume clover-type high-purity germanium (HPGe) $γ$-ray det…
▽ More
Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new high-efficiency $γ$-ray spectrometer designed for use in decay spectroscopy experiments with low-energy radioactive ion beams provided by TRIUMF's Isotope Separator and Accelerator (ISAC-I) facility. GRIFFIN is composed of sixteen Compton-suppressed large-volume clover-type high-purity germanium (HPGe) $γ$-ray detectors combined with a suite of ancillary detection systems and coupled to a custom digital data acquisition system. The infrastructure and detectors of the spectrometer as well as the performance characteristics and the analysis techniques applied to the experimental data are described.
△ Less
Submitted 6 December, 2018; v1 submitted 17 September, 2018;
originally announced September 2018.
-
In-beam internal conversion electron spectroscopy with the SPICE detector
Authors:
M. Moukaddam,
J. Smallcombe,
L. J. Evitts,
A. B. Garnsworthy,
C. Andreoiu,
G. C. Ball,
J. Berean-Dutcher,
D. Bishop,
C. Bolton,
R. Caballero-Folch,
M. Constable,
D. S. Cross,
T. E. Drake,
R. Dunlop,
P. E. Garrett,
S. Georges,
G. Hackman,
S. Hallam,
J. Henderson,
R. Henderson,
R. Krücken,
L. Kurchaninov,
A. Kurkjian,
B. Olaizola,
E. O'Sullivan
, et al. (14 additional authors not shown)
Abstract:
The SPectrometer for Internal Conversion Electrons (SPICE) has been commissioned for use in conjunction with the TIGRESS $γ$-ray spectrometer at TRIUMF's ISAC-II facility. SPICE features a permanent rare-earth magnetic lens to collect and direct internal conversion electrons emitted from nuclear reactions to a thick, highly segmented, lithium-drifted silicon detector. This arrangement, combined wi…
▽ More
The SPectrometer for Internal Conversion Electrons (SPICE) has been commissioned for use in conjunction with the TIGRESS $γ$-ray spectrometer at TRIUMF's ISAC-II facility. SPICE features a permanent rare-earth magnetic lens to collect and direct internal conversion electrons emitted from nuclear reactions to a thick, highly segmented, lithium-drifted silicon detector. This arrangement, combined with TIGRESS, enables in-beam $γ$-ray and internal conversion electron spectroscopy to be performed with stable and radioactive ion beams. Technical aspects of the device, capabilities, and initial performance are presented.
△ Less
Submitted 8 August, 2018;
originally announced August 2018.
-
Gamma-gamma angular correlation analysis techniques with the GRIFFIN spectrometer
Authors:
J. K. Smith,
A. D. MacLean,
W. Ashfield,
A. Chester,
A. B. Garnsworthy,
C. E. Svensson
Abstract:
Gamma-gamma angular correlation measurements are a powerful tool for identifying the angular momentum (spin) of excited nuclear states involved in a $γ$-ray cascade, and for measuring the multipole orders and mixing ratios of transitions. Though the physical angular correlations are fully calculable from first principles, experimental effects can make the extraction of coefficients and thus conclu…
▽ More
Gamma-gamma angular correlation measurements are a powerful tool for identifying the angular momentum (spin) of excited nuclear states involved in a $γ$-ray cascade, and for measuring the multipole orders and mixing ratios of transitions. Though the physical angular correlations are fully calculable from first principles, experimental effects can make the extraction of coefficients and thus conclusions about spins and mixing ratios difficult. In this article we present data analysis techniques developed for the clover detectors of the GRIFFIN spectrometer at TRIUMF-ISAC combined with GEANT4 simulations in order to extract accurate experimental results.
△ Less
Submitted 19 July, 2018;
originally announced July 2018.
-
The GRIFFIN Data Acquisition System
Authors:
A. B. Garnsworthy,
C. J. Pearson,
D. Bishop,
B. Shaw,
J. K. Smith,
M. Bowry,
V. Bildstein,
G. Hackman,
P. E. Garrett,
Y. Linn,
J. -P. Martin,
W. J. Mills,
C. E. Svensson
Abstract:
Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. This article describes the details of the custom designed GRIFFIN digital data acquisition system. The features of the system that will enable high-precision half-life and branching ratio measurements with levels of uncertainty bett…
▽ More
Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. This article describes the details of the custom designed GRIFFIN digital data acquisition system. The features of the system that will enable high-precision half-life and branching ratio measurements with levels of uncertainty better than 0.05% are described. The system has demonstrated the ability to effectively collect signals from High-purity germanium crystals at counting rates up to 50kHz while maintaining good energy resolution, detection efficiency and spectral quality.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
Characteristics of GRIFFIN high-purity germanium clover detectors
Authors:
U. Rizwan,
A. B. Garnsworthy,
C. Andreoiu,
G. C. Ball,
A. Chester,
T. Domingo,
R. Dunlop,
G. Hackman,
E. T. Rand,
J. K. Smith,
K. Starosta,
C. E. Svensson,
P. Voss,
J. Williams
Abstract:
The Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. The performance of the 16 high-purity germanium (HPGe) clover detectors that will make up the GRIFFIN spectrometer is reported. The energy resolution, efficiency, timing resolution, crosstalk and preamplifier properties of each…
▽ More
The Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. The performance of the 16 high-purity germanium (HPGe) clover detectors that will make up the GRIFFIN spectrometer is reported. The energy resolution, efficiency, timing resolution, crosstalk and preamplifier properties of each crystal were measured using a combination of analogue and digital data acquisition techniques. The absolute efficiency and add-back factors are determined for the energy range of 80 - 3450 keV. The detectors show excellent performance with an average over all 64 crystals of a FWHM energy resolution of 1.89(6) keV and relative efficiency with respect to a 3"x3" NaI detector of 41(1)% at 1.3 MeV.
△ Less
Submitted 14 November, 2017;
originally announced November 2017.