The CRAB facility at the TU Wien TRIGA reactor: status and related physics program
Authors:
H. Abele,
P. Ajello,
A. Armatol,
B. Arnold,
J. Billard,
E. Bossio,
J. Burkhart,
F. Cappella,
N. Casali,
R. Cerulli,
J. Colas,
J-P. Crocombette,
G. del Castello,
M. del Gallo Roccagiovine,
S. Dorer,
C. Doutre,
A. Erhart,
S. Fichtinger,
M. Friedl,
P. Garin,
R. Gergen,
C. Goupy,
D. Hainz,
D. Hauff,
E. Jericha
, et al. (29 additional authors not shown)
Abstract:
The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The CRAB method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined…
▽ More
The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The CRAB method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. A crown of BaF$_2$ detectors installed outside the dewar enables coincident detection of the high-energy $γ$ escaping the target crystal after neutron capture. After the presentation of all components of the setup we report the analysis of first commissioning data with a CaWO$_4$ detector of the \NUCLEUS experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $^{187}$W. Finally, we present the first evidence of neutron-capture induced coincidences between $γ$-detectors and a cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO$_4$, Al$_2$O$_3$, Ge and Si.
△ Less
Submitted 21 May, 2025;
originally announced May 2025.
The accomplishment of the Engineering Design Activities of IFMIF/EVEDA: The European Japanese project towards a Li(d,xn) fusion relevant neutron source
Authors:
J. Knaster,
A. Ibarra,
J. Abal,
A. Abou Sena,
F. Arbeiter,
F. Arranz,
J. M. Arroyo,
E. Bargallo,
P. Y. Beauvais,
D. Bernardi,
N. Casal,
J. M. Carmona,
N. Chauvin,
M. Comunian,
O. Delferriere,
A. Delgado,
P. Diaz Arocas,
U. Fischer,
M. Frisoni,
A. Garcia,
P. Garin,
R. Gobin,
P. Gouat,
F. Groesche,
R. Heidinger
, et al. (42 additional authors not shown)
Abstract:
The International Fusion Materials Irradiation Facility (IFMIF), presently in its Engineering Validation and Engineering Design Activities (EVEDA) phase under the frame of the Broader Approach Agreement between Europe and Japan, accomplished in summer 2013, on schedule, its EDA phase with the release of the engineering design report of the IFMIF plant, which is here described. Many improvements of…
▽ More
The International Fusion Materials Irradiation Facility (IFMIF), presently in its Engineering Validation and Engineering Design Activities (EVEDA) phase under the frame of the Broader Approach Agreement between Europe and Japan, accomplished in summer 2013, on schedule, its EDA phase with the release of the engineering design report of the IFMIF plant, which is here described. Many improvements of the design from former phases are implemented, particularly a reduction of beam losses and operational costs thanks to the superconducting accelerator concept, the re-location of the quench tank outside the test cell (TC) with a reduction of tritium inventory and a simplification on its replacement in case of failure, the separation of the irradiation modules from the shielding block gaining irradiation flexibility and enhancement of the remote handling equipment reliability and cost reduction, and the water cooling of the liner and biological shielding of the TC, enhancing the efficiency and economy of the related sub-systems. In addition, the maintenance strategy has been modified to allow a shorter yearly stop of the irradiation operations and a more careful management of the irradiated samples. The design of the IFMIF plant is intimately linked with the EVA phase carried out since the entry into force of IFMIF/EVEDA in June 2007.
△ Less
Submitted 28 December, 2021;
originally announced December 2021.