Background characterization of the CONUS+ experimental location
Authors:
CONUS Collaboration,
E. Sanchez Garcia,
N. Ackermann,
S. Armbruster,
H. Bonet,
C. Buck,
K. Fulber,
J. Hakenmuller,
J. Hempfling,
G. Heusser,
E. Hohmann,
M. Lindner,
W. Maneschg,
K. Ni,
M. Rank,
T. Rink,
I. Stalder,
H. Strecker,
R. Wink,
J. Woenckhaus
Abstract:
CONUS+ is an experiment aiming at detecting coherent elastic neutrino-nucleus scattering (CE$ν$NS) of reactor antineutrinos on germanium nuclei in the fully coherent regime, continuing the CONUS physics program conducted at the Brokdorf nuclear power plant (KBR), Germany. The CONUS+ experiment is installed in the Leibstadt nuclear power plant (KKL), Switzerland, at a distance of 20.7 m from the 3.…
▽ More
CONUS+ is an experiment aiming at detecting coherent elastic neutrino-nucleus scattering (CE$ν$NS) of reactor antineutrinos on germanium nuclei in the fully coherent regime, continuing the CONUS physics program conducted at the Brokdorf nuclear power plant (KBR), Germany. The CONUS+ experiment is installed in the Leibstadt nuclear power plant (KKL), Switzerland, at a distance of 20.7 m from the 3.6 GW reactor core, where the antineutrino flux is $1.5\cdot 10^{13}$~s$^{-1}$cm$^{-2}$. The CE$ν$NS signature will be measured with four point-contact high-purity low energy threshold germanium (HPGe) detectors. A good understanding of the background is crucial, especially events correlated with the reactor thermal power are troublesome. A large background characterization campaign was conducted during reactor on and off times to find the best location for the CONUS+ setup. On-site measurements revealed a correlated, highly thermalized neutron field with a maximum fluence rate of $(2.3\pm0.1)\cdot 10^{4}$~neutrons~d$^{-1}$cm$^{-2}$ during reactor operation. The $γ$-ray background was studied with a HPGe detector without shield. The muon flux was examined using a liquid scintillator detector measuring (107$\pm$3)~muons~s$^{-1}$m$^{-2}$, which corresponds to an average overburden of 7.4~m of water equivalent. The new background conditions in CONUS+ are compared to the previous CONUS ones, showing a 30 times higher flux of neutrons, but a 26 times lower component of reactor thermal power correlated $γ$-rays over 2.7 MeV. The lower CONUS+ overburden increases the number of muon-induced neutrons by 2.3 times and the flux of cosmogenic neutrons. Finally, all the measured rates are discussed in the context of the CONUS+ background, together with the CONUS+ modifications performed to reduce the impact of the new background conditions at KKL.
△ Less
Submitted 18 December, 2024;
originally announced December 2024.
-
Pulse shape discrimination for the CONUS experiment in the keV and sub-keV regime
Authors:
H. Bonet,
A. Bonhomme,
C. Buck,
K. Fülber,
J. Hakenmüller,
J. Hempfling,
J. Henrichs,
G. Heusser,
M. Lindner,
W. Maneschg,
T. Rink,
E. Sanchez Garcia,
J. Stauber,
H. Strecker,
R. Wink
Abstract:
Point-contact p-type high-purity germanium detectors (PPC HPGe) are particularly suited for detection of sub-keV nuclear recoils from coherent elastic scattering of neutrinos or light dark matter particles. While these particles are expected to interact homogeneously in the entire detector volume, specific classes of external background radiation preferably deposit their energy close to the semi-a…
▽ More
Point-contact p-type high-purity germanium detectors (PPC HPGe) are particularly suited for detection of sub-keV nuclear recoils from coherent elastic scattering of neutrinos or light dark matter particles. While these particles are expected to interact homogeneously in the entire detector volume, specific classes of external background radiation preferably deposit their energy close to the semi-active detector surface, in which diffusion processes dominate that subsequently lead to slower rising pulses compared to the ones from the fully active bulk volume. Dedicated studies of their shape are therefore highly beneficial for the understanding and the rejection of these unwanted events. This article reports about the development of a data-driven pulse shape discrimination (PSD) method for the four 1 kg size PPC HPGe detectors of the CONUS experiment in the keV and sub-keV regime down to 210 eV$_{\text{ee}}$. The impact of the electronic noise at such low energies is carefully examined. It is shown that for an acceptance of 90% of the faster signal-like pulses from the bulk volume, approx. 50% of the surface events can be rejected at the energy threshold and that their contribution is fully suppressed above 800 eV$_{\text{ee}}$. Applied to the CONUS background data, such a PSD rejection cut allows to achieve an overall (15-25)% reduction of the total background budget. The new method allows to improve the sensitivity of future CONUS analyses and to refine the corresponding background model in the sub-keV energy region.
△ Less
Submitted 9 February, 2024; v1 submitted 23 August, 2023;
originally announced August 2023.
-
Experimental study of the positive ion feedback from gas to liquid in a dual-phase argon chamber and measurement of the ion mobility in argon gas
Authors:
Luciano Romero,
Roberto Santorelli,
Edgar Sánchez García,
Thorsten Lux,
Michael Leyton,
Silvestro di Luise,
Pablo García Abia,
Rodrigo López Manzano,
José Manuel Cela-Ruiz,
Sebastián Quizhpi,
Vicente Pesudo
Abstract:
The dynamics of the positive ions created by particle interactions inside argon time projection chambers plays an important role in characterizing the next generation of massive detectors planned for the direct search for dark matter and the study of neutrino properties. We have constructed a 1 L liquid argon chamber (ARION: ARgon ION experiment) with a high voltage pulse generator capable of inje…
▽ More
The dynamics of the positive ions created by particle interactions inside argon time projection chambers plays an important role in characterizing the next generation of massive detectors planned for the direct search for dark matter and the study of neutrino properties. We have constructed a 1 L liquid argon chamber (ARION: ARgon ION experiment) with a high voltage pulse generator capable of injecting, in a controlled manner, a sizeable ion current into the drift region. This chamber is capable of reproducing a volume charge similar to that found in large detectors, allowing its effects to be studied systematically. New experimental results regarding ion dynamics in the liquid and direct demonstration of ion feedback from the gas to the liquid are discussed in this paper. In addition, a novel technique to measure the drift velocity of argon ions is introduced along with preliminary results obtained in gas.
△ Less
Submitted 21 February, 2022; v1 submitted 29 December, 2021;
originally announced December 2021.
-
Time and band-resolved scintillation in time projection chambers based on gaseous xenon
Authors:
S. Leardini,
E. Sánchez García,
P. Amedo,
A. Saa-Hernández,
D. González-Díaz,
R. Santorelli,
D. J. Fernández-Posada,
D. González
Abstract:
We present a systematic study of the time and band-resolved scintillation in xenon-based time projection chambers (TPCs), performed simultaneously for the primary (S1) and secondary (S2) components in a small, purity-controlled, setup. We explore a range of conditions of general academic interest, focusing on those of relevance to contemporary TPCs: pressure range ([1- 10] bar), pressure-reduced e…
▽ More
We present a systematic study of the time and band-resolved scintillation in xenon-based time projection chambers (TPCs), performed simultaneously for the primary (S1) and secondary (S2) components in a small, purity-controlled, setup. We explore a range of conditions of general academic interest, focusing on those of relevance to contemporary TPCs: pressure range ([1- 10] bar), pressure-reduced electric fields ([0-100] V/cm/bar in the drift region (S1) and up to the proportional scintillation regime in the multiplication region (S2)), wavelength-band ([145-250], [250-400], [400-600] nm), and primary excitation ($α$, $β$-particles). Attention is paid to the possibility of non-conventional scintillation mechanisms such as the 3rd continuum emission, recombination light from $β$-electrons at high pressure (for S1), emission from high-lying excited states and neutral bremsstrahlung (for S2). Time constants and, specially, scintillation yields have been obtained as a function of electric field and pressure, the latter aided by Geant4 simulations.
△ Less
Submitted 26 January, 2022; v1 submitted 9 December, 2021;
originally announced December 2021.
-
Spectroscopic analysis of the argon scintillation with a wavelength sensitive particle detector
Authors:
R. Santorelli,
E. Sanchez Garcia,
P. Garcia Abia,
D. González-Díaz,
R. Lopez Manzano,
J. J. Martinez Morales,
V. Pesudo,
L. Romero
Abstract:
We performed a time-resolved spectroscopic study of the VUV/UV argon scintillation as a function of pressure and electric field, by means of a wavelength sensitive detector operated with different radioactive sources. Our work conveys new evidence of distinctive features of the argon light which are in contrast with the general assumption that, for particle detection purposes, the scintillation ca…
▽ More
We performed a time-resolved spectroscopic study of the VUV/UV argon scintillation as a function of pressure and electric field, by means of a wavelength sensitive detector operated with different radioactive sources. Our work conveys new evidence of distinctive features of the argon light which are in contrast with the general assumption that, for particle detection purposes, the scintillation can be considered to be largely monochromatic at 128 nm (second continuum). The wavelength and the time-resolved analysis of the photon emission reveal that the dominant component of the argon scintillation during first tens of ns is in the range [160, 325] nm. This light is consistent with the third continuum emission from highly charged argon ions/molecules. This component of the scintillation is field-independent up to 25 V/cm/bar and shows a very mild dependence with pressure in the range [1,16] bar. The dynamics of the second continuum emission is dominated by the excimer formation time, whose variation as a function of the pressure has been measured. Additionally, the time and pressure-dependent features of electron-ion recombination, in the second continuum band, have been measured. This study opens new paths toward a novel particle identification technique based on the spectral information of the noble-elements scintillation light.
△ Less
Submitted 15 December, 2020;
originally announced December 2020.
-
Sensitivity of future liquid argon dark matter search experiments to core-collapse supernova neutrinos
Authors:
P. Agnes,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
S. Arcelli,
M. Ave,
I. Ch. Avetissov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
A. Bondar,
W. M. Bonivento,
E. Borisova,
B. Bottino,
M. G. Boulay,
G. Buccino
, et al. (251 additional authors not shown)
Abstract:
Future liquid-argon DarkSide-20k and ARGO detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of $\sim$50~t and $\sim$360~t for DarkSide-20k and AR…
▽ More
Future liquid-argon DarkSide-20k and ARGO detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of $\sim$50~t and $\sim$360~t for DarkSide-20k and ARGO, respectively.
Thanks to the low-energy threshold of $\sim$0.5~keV$_{nr}$ achievable by exploiting the ionization channel, DarkSide-20k and ARGO have the potential to discover supernova bursts throughout our galaxy and up to the Small Magellanic Cloud, respectively, assuming a 11-M$_{\odot}$ progenitor star. We report also on the sensitivity to the neutronization burst, whose electron neutrino flux is suppressed by oscillations when detected via charged current and elastic scattering. Finally, the accuracies in the reconstruction of the average and total neutrino energy in the different phases of the supernova burst, as well as its time profile, are also discussed, taking into account the expected background and the detector response.
△ Less
Submitted 31 December, 2020; v1 submitted 16 November, 2020;
originally announced November 2020.
-
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
Authors:
The DarkSide collaboration,
C. E. Aalseth,
S. Abdelhakim,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
V. Barbaryan,
A. Barrado Olmedo,
G. Batignani
, et al. (290 additional authors not shown)
Abstract:
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the…
▽ More
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms ("neutral bremsstrahlung", NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.
△ Less
Submitted 26 February, 2021; v1 submitted 4 April, 2020;
originally announced April 2020.
-
The liquid-argon scintillation pulseshape in DEAP-3600
Authors:
The DEAP collaboration,
P. Adhikari,
R. Ajaj,
G. R. Araujoand M. Batygov,
B. Beltran,
C. E. Bina,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
Y. Chen,
B. T. Cleveland,
J. M. Corning,
S. J. Daughertyand K. Dering,
L. Doria,
F. A. Duncan andM. Dunford,
A. Erlandson,
N. Fatemighomi,
G. Fiorillo,
A. Flower,
R. J. Ford,
R. Gagnon
, et al. (76 additional authors not shown)
Abstract:
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed…
▽ More
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed here is the basis of PSD.
The observed pulseshape is a combination of LAr scintillation physics with detector effects. We present a model for the pulseshape of electromagnetic background events in the energy region of interest for dark matter searches. The model is composed of a) LAr scintillation physics, including the so-called intermediate component, b) the time response of the TPB wavelength shifter, including delayed TPB emission at $\mathcal O$(ms) time-scales, and c) PMT response.
TPB is the wavelength shifter of choice in most LAr detectors. We find that approximately 10\% of the intensity of the wavelength-shifted light is in a long-lived state of TPB. This causes light from an event to spill into subsequent events to an extent not usually accounted for in the design and data analysis of LAr-based detectors.
△ Less
Submitted 8 June, 2020; v1 submitted 27 January, 2020;
originally announced January 2020.
-
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
Authors:
The DarkSide Collaboration,
C. E. Aalseth,
S. Abdelhakim,
F. Acerbi,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
A. Barrado Olmedo,
G. Batignani
, et al. (306 additional authors not shown)
Abstract:
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioa…
▽ More
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $γ$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
△ Less
Submitted 22 January, 2020;
originally announced January 2020.
-
DArT, a detector for measuring the 39Ar depletion factor
Authors:
E. Sánchez García
Abstract:
One of the most powerful techniques for direct detection of dark matter via elastic scattering of galactic WIMPs is the use of liquid argon time projection chambers. Atmospheric argon (AAr) has a naturally occurring radioactive isotope, \ar{}, of cosmogenic origin. The use of argon extracted from underground wells, deprived of \ar{}, is key to the physics potential of these experiments. The DarkSi…
▽ More
One of the most powerful techniques for direct detection of dark matter via elastic scattering of galactic WIMPs is the use of liquid argon time projection chambers. Atmospheric argon (AAr) has a naturally occurring radioactive isotope, \ar{}, of cosmogenic origin. The use of argon extracted from underground wells, deprived of \ar{}, is key to the physics potential of these experiments. The DarkSide-20k (DS-20k) dark matter search experiment will operate with 50 tonnes of radio-pure underground argon (UAr), extracted from the Urania plant in Cortez (USA) and purified in the Aria distillation plant (Sardinia, Italy). Assessing the radio-purity of UAr in terms of \ar{} is crucial for the success of DS-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC), and will be done with the experiment named \dia{}. DArT is a small chamber that will contain the argon under test. The detector will be immersed in the LAr active volume of the ArDM detector, located at the Canfranc Underground Laboratory (LSC) in Spain, which will act as active veto for background events coming from photons from detector materials and surrounding rock radioactivity.
△ Less
Submitted 22 January, 2020;
originally announced January 2020.
-
AVOLAR. A high voltage generator for liquid argon time projection chambers
Authors:
L. Romero,
J. M. Cela,
E. Sanchez Garcia,
M. Daniel,
M. de Prado
Abstract:
Some of the main neutrino oscillation and dark matter experiments have chosen time projection chambers (TPC) filled with liquid argon (LAr) as their technology for the next generation of detectors. Because of its typical drift length of several meters, relatively large cathode voltages are desirable to provide a sizeable drift field. Current designs are based on feedthroughs with high voltages (HV…
▽ More
Some of the main neutrino oscillation and dark matter experiments have chosen time projection chambers (TPC) filled with liquid argon (LAr) as their technology for the next generation of detectors. Because of its typical drift length of several meters, relatively large cathode voltages are desirable to provide a sizeable drift field. Current designs are based on feedthroughs with high voltages (HV) limited to several hundred kV. The present work proposes a novel method to produce higher voltages inside the detector. It is based on a Van de Graaff HV generator where the charge transporting belt is replaced by a cryogenic LAr flow. Negative charge is injected in liquid by means of a grounded sharp point facing a positive voltage electrode with a high speed LAr stream in between. The LAr flow transports the charge to the cathode through an electrically insulating pipe. In the cathode the charge is extracted with a metallic mesh. The LAr flux is driven by a cryogenic helium pump with unidirectional valves assuring a continuous flow. The LAr operational temperature is maintained by a pressurized liquid nitrogen deposit with automatic filling. The whole system is installed within a dewar container that will be filled with LAr reproducing the typical TPC conditions. This design has no mobile parts, so it is very robust and can be easily embedded within the structural support of a TPC cathode. A prototype of this HV generator has been constructed at CIEMAT (Madrid), and is currently being characterized. This R&D is presented and the preliminary results are discussed.
△ Less
Submitted 7 February, 2020; v1 submitted 15 January, 2020;
originally announced January 2020.
-
Impact of the positive ion current on large size neutrino detectors and delayed photon emission
Authors:
R. Santorelli,
S. di Luise,
E. Sanchez Garcia,
P. Garcia Abia,
T. Lux,
V. Pesudo,
L. Romero
Abstract:
Given their small mobility coefficient in liquid argon with respect to the electrons, the ions spend a considerably longer time in the active volume. We studied the effects of the positive ion current in a liquid argon time projection chamber, in the context of massive argon experiments for neutrino physics. The constant recombination between free ions and electrons produces a quenching of the cha…
▽ More
Given their small mobility coefficient in liquid argon with respect to the electrons, the ions spend a considerably longer time in the active volume. We studied the effects of the positive ion current in a liquid argon time projection chamber, in the context of massive argon experiments for neutrino physics. The constant recombination between free ions and electrons produces a quenching of the charge signal and a constant emission of photons, uncorrelated in time and space to the physical interactions. The predictions evidence some potential concerns for multi-ton argon detectors, particularly when operated on surface
△ Less
Submitted 21 December, 2017;
originally announced December 2017.
-
DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
M. Ave,
H. O. Back,
A. I. Barrado Olmedo,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino
, et al. (260 additional authors not shown)
Abstract:
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a…
▽ More
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50 demonstrated a major reduction in the dominant $^{39}$Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of $\gt3\times10^9$ is achievable. This, along with the use of the veto system, is the key to unlocking the path to large LArTPC detector masses, while maintaining an "instrumental background-free" experiment, an experiment in which less than 0.1 events (other than $ν$-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ. This will give sensitivity to WIMP-nucleon cross sections of $1.2\times10^{-47}$ cm$^2$ ($1.1\times10^{-46}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background. DarkSide-20k could then extend its operation to a decade, increasing the exposure to 200 t yr, reaching a sensitivity of $7.4\times10^{-48}$ cm$^2$ ($6.9\times10^{-47}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass.
△ Less
Submitted 25 July, 2017;