-
Study of the decay and production properties of $D_{s1}(2536)$ and $D_{s2}^*(2573)$
Authors:
M. Ablikim,
M. N. Achasov,
P. Adlarson,
O. Afedulidis,
X. C. Ai,
R. Aliberti,
A. Amoroso,
Q. An,
Y. Bai,
O. Bakina,
I. Balossino,
Y. Ban,
H. -R. Bao,
V. Batozskaya,
K. Begzsuren,
N. Berger,
M. Berlowski,
M. Bertani,
D. Bettoni,
F. Bianchi,
E. Bianco,
A. Bortone,
I. Boyko,
R. A. Briere,
A. Brueggemann
, et al. (645 additional authors not shown)
Abstract:
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be…
▽ More
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be $(35.9\pm 4.8\pm 3.5)\%$ and $(37.4\pm 3.1\pm 4.6)\%$, respectively. The measurements are in tension with predictions based on the assumption that the $D_{s1}(2536)$ and $D_{s2}^*(2573)$ are dominated by a bare $c\bar{s}$ component. The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ cross sections are measured, and a resonant structure at around 4.6~GeV with a width of 50~MeV is observed for the first time with a statistical significance of $15σ$ in the $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ process. It could be the $Y(4626)$ found by the Belle collaboration in the $D_s^+D_{s1}(2536)^{-}$ final state, since they have similar masses and widths. There is also evidence for a structure at around 4.75~GeV in both processes.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Track-based alignment for the BESIII CGEM detector in the cosmic-ray test
Authors:
A. Q. Guo,
L. H. Wu,
L. L. Wang,
R. E. Mitchell,
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Y. Dong,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
I. Garzia,
M. Gatta
, et al. (27 additional authors not shown)
Abstract:
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Beijing Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical tri…
▽ More
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Beijing Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical triple Gas Electron Multipliers (CGEM). The transverse plane spatial resolution of CGEM is required to be 120 $μ$m or better. To meet this goal, a careful calibration of the detector is necessary to fully exploit the potential of the CGEM detector. In all the calibrations, the detector alignment plays an important role to improve the detector precision. The track-based alignment for the CGEM detector with the Millepede algorithm is implemented to reduce the uncertainties of the hit position measurement. Using the cosmic-ray data taken in 2020 with the two layers setup, the displacement and rotation of the outer layer with respect to the inner layer is determined by a simultaneous fit applied to more than 160000 tracks. A good alignment precision has been achieved that guarantees the design request could be satisfied in the future. A further alignment is going to be performed using the combined information of tracks from cosmic-ray and collisions after the CGEM is installed into the BESIII detector.
△ Less
Submitted 14 December, 2022; v1 submitted 2 November, 2022;
originally announced November 2022.
-
Data acquisition system for a 146-channel counter of protons in particle therapy
Authors:
S. Giordanengo,
M. Abujami,
C. Galeone,
S. Garbolino,
O. A. Martì Villarreal,
F. Mas Milian,
G. Mazza,
M. Mignone,
A. Vignati,
R. Wheadon,
R. Cirio,
V. Monaco,
R. Sacchi
Abstract:
A prototype of proton counter was developed by the University and the National Institute for Nuclear Physics of Torino to be used as online fluence beam monitor in particle therapy. The single particle identification approach aims at increasing the sensitivity and readout speed with respect to the state-of-the-art gas ionization chambers. The sensitive area is 2,7 x 2,7 cm^2 to cover the clinical…
▽ More
A prototype of proton counter was developed by the University and the National Institute for Nuclear Physics of Torino to be used as online fluence beam monitor in particle therapy. The single particle identification approach aims at increasing the sensitivity and readout speed with respect to the state-of-the-art gas ionization chambers. The sensitive area is 2,7 x 2,7 cm^2 to cover the clinical beam cross section characterized by a full width at half maximum of about 1 cm at the isocenter. The sensor is a thin Low Gain Avalanche Diode segmented in 146 strips with 180 micrometer pitch and with 50 micrometer active thickness, designed and produced by the Fondazione Bruno Kessler (Trento, Italy). The frontend readout to identify the single proton signal provided by each strip is based on a 24channel custom ASICs, named ABACUS, optimized to discriminate the signal pulses in a wide charge range (3-150 fC) with a maximum dead-time of 10 ns. With these specifications, at the maximum fluence rate of 10^8 p/(cm^2s) in the clinical energy range (60-230 MeV) and considering the silicon strips described above, a maximum pileup counting inefficiency less than 1 percent is achieved. A frontend board housing 6 ABACUS chips to readout the 146 strips was developed, the digital outputs being sent to 3 FPGAs (Kintex7) for the counting. A LabVIEW program implements the interface with the FPGAs, displays online the counting rate from each strip and stores the data for offline analysis.
△ Less
Submitted 6 May, 2022;
originally announced May 2022.
-
The CGEM-IT readout chain
Authors:
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
R. Bugalho,
A. Calcaterra,
S. Cerioni,
S. Chiozzi,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
A. Di Francesco,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
S. Garbolino,
I. Garzia,
M. Gatta
, et al. (22 additional authors not shown)
Abstract:
An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output b…
▽ More
An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output by TIGER are collected and processed by a first FPGA-based module, GEM Read Out Card, in charge of configuration and control of the front-end ASICs. A second FPGA-based module, named GEM Data Concentrator, builds the trigger selected event packets containing the data and stores them via the main BESIII data acquisition system. The design of the electronics chain, including the power and signal distribution, will be presented together with its performance.
△ Less
Submitted 17 August, 2021; v1 submitted 19 May, 2021;
originally announced May 2021.