-
Development of a High-Doppler Shift Optical Simulator to Test Femtosecond-Level Optical Time-Frequency Transfer
Authors:
Matthew S. Bigelow,
Kyle W. Martin,
Nolan Matthews,
Benjamin K. Stuhl,
Richard Gonzales,
Alexandre de Pinho e Braga,
John Elgin,
Kimberly A. Frey
Abstract:
We have developed an optical simulator to test optical two-way time-frequency transfer (O-TWTFT) at the femtosecond level capable of simulating relative motion between two linked optical clock nodes up to Mach 1.8 with no moving parts. The technique is enabled by artificially Doppler shifting femtosecond pulses from auxiliary stabilized optical frequency combs. These pulses are exchanged between t…
▽ More
We have developed an optical simulator to test optical two-way time-frequency transfer (O-TWTFT) at the femtosecond level capable of simulating relative motion between two linked optical clock nodes up to Mach 1.8 with no moving parts. The technique is enabled by artificially Doppler shifting femtosecond pulses from auxiliary stabilized optical frequency combs. These pulses are exchanged between the nodes to simulate the Doppler shifts observed from a changing optical path length. We can continuously scan the simulated velocity from 14 to 620 m/s while simultaneously measuring velocity-dependent clock shifts at much higher velocities than has been previously recorded. This system provides an effective testbed that allows us to explore issues and solutions to enable femtosecond-level optical time transfer at high velocity.
△ Less
Submitted 17 September, 2025;
originally announced September 2025.
-
The Belle II Detector Upgrades Framework Conceptual Design Report
Authors:
H. Aihara,
A. Aloisio,
D. P. Auguste,
M. Aversano,
M. Babeluk,
S. Bahinipati,
Sw. Banerjee,
M. Barbero,
J. Baudot,
A. Beaubien,
F. Becherer,
T. Bergauer,
F. U. Bernlochner.,
V. Bertacchi,
G. Bertolone,
C. Bespin,
M. Bessner,
S. Bettarini,
A. J. Bevan,
B. Bhuyan,
M. Bona,
J. F. Bonis,
J. Borah,
F. Bosi,
R. Boudagga
, et al. (186 additional authors not shown)
Abstract:
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive wit…
▽ More
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive with the LHC and other experiments.
△ Less
Submitted 4 July, 2024; v1 submitted 26 June, 2024;
originally announced June 2024.
-
Upgrade of Belle II Vertex Detector with CMOS Pixel Technology
Authors:
M. Schwickardi,
M. Babeluk,
M. Barbero,
J. Baudot,
T. Bergauer,
G. Bertolone,
S. Bettarini,
F. Bosi,
P. Breugnon,
Y. Buch,
G. Casarosa,
G. Dujany,
C. Finck,
F. Forti,
A. Frey,
A. Himmi,
C. Irmler,
A. Kumar,
C. Marinas,
M. Massa,
L. Massaccesi,
J. Mazzora de Cos,
M. Minuti,
S. Mondal,
P. Pangaud
, et al. (5 additional authors not shown)
Abstract:
The Belle II experiment at KEK in Japan considers upgrading its vertex detector system to address the challenges posed by high background levels caused by the increased luminosity of the SuperKEKB collider. One proposal for upgrading the vertex detector aims to install a 5-layer all monolithic pixel vertex detector based on fully depleted CMOS sensors in 2027. The new system will use the OBELIX MA…
▽ More
The Belle II experiment at KEK in Japan considers upgrading its vertex detector system to address the challenges posed by high background levels caused by the increased luminosity of the SuperKEKB collider. One proposal for upgrading the vertex detector aims to install a 5-layer all monolithic pixel vertex detector based on fully depleted CMOS sensors in 2027. The new system will use the OBELIX MAPS chips to improve background robustness and reduce occupancy levels through small and fast pixels. This causes better track finding, especially for low transverse momenta tracks. This text will focus on the predecessor of the OBELIX sensor, the TJ-Monopix2, presenting laboratory and test beam results on pixel response, efficiency, and spatial resolution.
△ Less
Submitted 12 December, 2023; v1 submitted 22 November, 2023;
originally announced November 2023.
-
Resonant two-laser spin-state spectroscopy of a negatively charged quantum dot-microcavity system with a cold permanent magnet
Authors:
P. Steindl,
T. van der Ent,
H. van der Meer,
J. A. Frey,
J. Norman,
J. E. Bowers,
D. Bouwmeester,
W. Löffler
Abstract:
A high-efficiency spin-photon interface is an essential piece of quantum hardware necessary for various quantum technologies. Self-assembled InGaAs quantum dots have excellent optical properties, if embedded into an optical micro-cavity they can show near-deterministic spin-photon entanglement and spin readout, but an external magnetic field is required to address the individual spin states, which…
▽ More
A high-efficiency spin-photon interface is an essential piece of quantum hardware necessary for various quantum technologies. Self-assembled InGaAs quantum dots have excellent optical properties, if embedded into an optical micro-cavity they can show near-deterministic spin-photon entanglement and spin readout, but an external magnetic field is required to address the individual spin states, which usually is done using a superconducting magnet. Here, we show a compact cryogenically compatible SmCo magnet design that delivers 475 mT in-plane Voigt geometry magnetic field at 5 K, which is suitable to lift the energy degeneracy of the electron spin states and trion transitions of a single InGaAs quantum dot. This quantum dot is embedded in a birefringent high-finesse optical micro-cavity which enables efficient collection of single photons emitted by the quantum dot. We demonstrate spin-state manipulation by addressing the trion transitions with a single and two laser fields. The experimental data agrees well to our model which covers single- and two-laser cross-polarized resonance fluorescence, Purcell enhancement in a birefringent cavity, and variation of the laser powers.
△ Less
Submitted 5 March, 2023;
originally announced March 2023.
-
Cross-polarization extinction enhancement and spin-orbit coupling of light for quantum-dot cavity-QED spectroscopy
Authors:
P. Steindl,
J. A. Frey,
J. Norman,
J. E. Bowers,
D. Bouwmeester,
W. Löffler
Abstract:
Resonant laser spectroscopy is essential for the characterization, operation, and manipulation of single quantum systems such as semiconductor quantum dots. The separation of the weak resonance fluorescence from the excitation laser is key for high-quality single- and entangled photon sources. This is often achieved by cross-polarization laser extinction, which is limited by the quality of the opt…
▽ More
Resonant laser spectroscopy is essential for the characterization, operation, and manipulation of single quantum systems such as semiconductor quantum dots. The separation of the weak resonance fluorescence from the excitation laser is key for high-quality single- and entangled photon sources. This is often achieved by cross-polarization laser extinction, which is limited by the quality of the optical elements. Recently, it was discovered that Fresnel-reflection birefringence in combination with single-mode filtering counteracting spin-orbit coupling effects enables a three-order of magnitude improvement of polarization extinction [PRX 11, 021007 (2021)]. Here, we first investigate multiple reflections and analyze beam reshaping, and observe that the single-reflection extinction enhancement is optimal. We then demonstrate this method for cross-polarization extinction enhancement for a resonantly excited semiconductor quantum dot in a birefringent optical micro cavity, and observe a 10x improvement of single-photon contrast.
△ Less
Submitted 10 February, 2023;
originally announced February 2023.
-
Measured and projected beam backgrounds in the Belle II experiment at the SuperKEKB collider
Authors:
A. Natochii,
T. E. Browder,
L. Cao,
G. Cautero,
S. Dreyer,
A. Frey,
A. Gabrielli,
D. Giuressi,
T. Ishibashi,
Y. Jin,
K. Kojima,
T. Kraetzschmar,
L. Lanceri,
Z. Liptak,
D. Liventsev,
C. Marinas,
L. Massaccesi,
K. Matsuoka,
F. Meier,
C. Miller,
H. Nakayama,
C. Niebuhr,
A. Novosel,
K. Parham,
I. Popov
, et al. (21 additional authors not shown)
Abstract:
The Belle II experiment at the SuperKEKB electron-positron collider aims to collect an unprecedented data set of $50~{\rm ab}^{-1}$ to study $CP$-violation in the $B$-meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world's highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak l…
▽ More
The Belle II experiment at the SuperKEKB electron-positron collider aims to collect an unprecedented data set of $50~{\rm ab}^{-1}$ to study $CP$-violation in the $B$-meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world's highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of $\rm 6 \times 10^{35}~cm^{-2}s^{-1}$ by further increasing the beam currents and reducing the beam size at the interaction point by squeezing the betatron function down to $β^{*}_{\rm y}=\rm 0.3~mm$. To ensure detector longevity and maintain good reconstruction performance, beam backgrounds must remain well controlled. We report on current background rates in Belle II and compare these against simulation. We find that a number of recent refinements have significantly improved the background simulation accuracy. Finally, we estimate the safety margins going forward. We predict that backgrounds should remain high but acceptable until a luminosity of at least $\rm 2.8 \times 10^{35}~cm^{-2}s^{-1}$ is reached for $β^{*}_{\rm y}=\rm 0.6~mm$. At this point, the most vulnerable Belle II detectors, the Time-of-Propagation (TOP) particle identification system and the Central Drift Chamber (CDC), have predicted background hit rates from single-beam and luminosity backgrounds that add up to approximately half of the maximum acceptable rates.
△ Less
Submitted 11 December, 2023; v1 submitted 3 February, 2023;
originally announced February 2023.
-
Measurements of Beam Backgrounds in SuperKEKB Phase 2
Authors:
Zachary J. Liptak,
Antonio Paladino,
Luka Santelj,
Jeffery Schueler,
Slavomira Stefkova,
Hikaru Tanigawa,
Noritsugu Tsuzuki,
Alberto Aloisio,
Patrick Ahlburg,
Philip Bambade,
Giovanni Bassi,
Matthew Barrett,
Jerome Baudot,
Thomas Browder,
Giulia Casarosa,
Giuseppe Cautero,
David Cinabro,
Gilles Claus,
Daniel Cuesta,
Francesco Di Capua,
Salvatore Di Carlo,
John Flanagan,
Ariane Frey,
Bryan Fulsom,
Yoshihiro Funakoshi
, et al. (44 additional authors not shown)
Abstract:
The high design luminosity of the SuperKEKB electron-positron collider will result in challenging levels of beam-induced backgro\ unds in the interaction region. Understanding and mitigating these backgrounds is critical to the success of the Belle~II experi\ ment. We report on the first background measurements performed after roll-in of the Belle II detector, a period known as SuperKE\ KB Phase 2…
▽ More
The high design luminosity of the SuperKEKB electron-positron collider will result in challenging levels of beam-induced backgro\ unds in the interaction region. Understanding and mitigating these backgrounds is critical to the success of the Belle~II experi\ ment. We report on the first background measurements performed after roll-in of the Belle II detector, a period known as SuperKE\ KB Phase 2, utilizing both the BEAST II system of dedicated background detectors and the Belle II detector itself. We also repor\ t on first revisions to the background simulation made in response to our findings. Backgrounds measured include contributions f\ rom synchrotron radiation, beam-gas, Touschek, and injection backgrounds. At the end of Phase 2, single-beam backgrounds origina\ ting from the 4 GeV positron Low Energy Ring (LER) agree reasonably well with simulation, while backgrounds from the 7 GeV elect\ ron High Energy Ring (HER) are approximately one order of magnitude higher than simulation. We extrapolate these backgrounds for\ ward and conclude it is safe to install the Belle II vertex detector.
△ Less
Submitted 29 December, 2021;
originally announced December 2021.
-
Effects of gamma irradiation on DEPFET pixel sensors for the Belle II experiment
Authors:
Harrison Schreeck,
Benjamin Schwenker,
Philipp Wieduwilt,
Ariane Frey,
Botho Paschen,
Florian Lütticke,
Patrick Ahlburg,
Jochen Dingfelder,
Carlos Marinas,
Ladislav Andricek,
Rainer Richter
Abstract:
For the Belle II experiment at KEK (Tsukuba, Japan) the KEKB accelerator was upgraded to deliver a 40 times larger instantaneous luminosity than before, which requires an increased radiation hardness of the detector components. As the innermost part of the Belle II detector, the pixel detector (PXD), based on DEPFET (DEpleted P-channel Field Effect Transistor) technology, is most exposed to radiat…
▽ More
For the Belle II experiment at KEK (Tsukuba, Japan) the KEKB accelerator was upgraded to deliver a 40 times larger instantaneous luminosity than before, which requires an increased radiation hardness of the detector components. As the innermost part of the Belle II detector, the pixel detector (PXD), based on DEPFET (DEpleted P-channel Field Effect Transistor) technology, is most exposed to radiation from the accelerator. An irradiation campaign was performed to verify that the PXD can cope with the expected amount of radiation. We present the results of this measurement campaign in which an X-ray machine was used to irradiate a single PXD half-ladder to a total dose of 266 kGy. The half-ladder is from the same batch as the half-ladders used for Belle II. According to simulations, the total accumulated dose corresponds to 7-10 years of Belle II operation. While individual components have been irradiated before, this campaign is the first full system irradiation. We discuss the effects on the DEPFET sensors, as well as the performance of the front-end electronics. In addition, we present efficiency studies of the half-ladder from beam tests performed before and after the irradiation.
△ Less
Submitted 22 September, 2021;
originally announced September 2021.
-
Mapping the material distribution of a complex structure in an electron beam
Authors:
Luise Poley,
Ulf Stolzenberg,
Benjamin Schwenker,
Ariane Frey,
Peter Göttlicher,
Carlos Marinas,
Marcel Stanitzki,
Bernd Stelzer
Abstract:
The simulation and analysis of High Energy Physics experiments require a realistic simulation of the detector material and its distribution. The challenge is to describe all active and passive parts of large scale detectors like ATLAS in terms of their size, position and material composition. The common method for estimating the radiation length by weighing individual components, adding up their c…
▽ More
The simulation and analysis of High Energy Physics experiments require a realistic simulation of the detector material and its distribution. The challenge is to describe all active and passive parts of large scale detectors like ATLAS in terms of their size, position and material composition. The common method for estimating the radiation length by weighing individual components, adding up their contributions and averaging the resulting material distribution over extended structures provides a good general estimate, but can deviate significantly from the material actually present. A method has been developed to assess its material distribution with high spatial resolution using the reconstructed scattering angles and hit positions of high energy electron tracks traversing an object under investigation. The study presented here shows measurements for an extended structure with a highly inhomogeneous material distribution. The structure under investigation is an End-of-Substructure-card prototype designed for the ATLAS Inner Tracker strip tracker -- a PCB populated with components of a large range of material budgets and sizes. The measurements presented here summarise requirements for data samples and reconstructed electron tracks for reliable image reconstruction of large scale, inhomogeneous samples, choices of pixel sizes compared to the size of features under investigation as well as a bremsstrahlung correction for high material densities and thicknesses.
△ Less
Submitted 21 May, 2021;
originally announced May 2021.
-
Performance of production modules of the Belle II pixel detector in a high-energy particle beam
Authors:
P. Wieduwilt,
B. Paschen,
H. Schreeck,
B. Schwenker,
J. Soltau,
P. Ahlburg,
J. Dingfelder,
A. Frey,
P. Gomis,
F. Lütticke,
C. Marinas
Abstract:
The Belle II experiment at the Super B factory SuperKEKB, an asymmetric $e^+e^-$ collider located in Tsukuba, Japan, is tailored to perform precision B physics measurements. The centre of mass energy of the collisions is equal to the rest mass of the $Υ(4S)$ resonance of $m_{Υ(4S)} = 10.58\,\rm GeV$. A high vertex resolution is essential for measuring the decay vertices of B mesons. Typical moment…
▽ More
The Belle II experiment at the Super B factory SuperKEKB, an asymmetric $e^+e^-$ collider located in Tsukuba, Japan, is tailored to perform precision B physics measurements. The centre of mass energy of the collisions is equal to the rest mass of the $Υ(4S)$ resonance of $m_{Υ(4S)} = 10.58\,\rm GeV$. A high vertex resolution is essential for measuring the decay vertices of B mesons. Typical momenta of the decay products are ranging from a few tens of MeV to a few GeV and multiple scattering has a significant impact on the vertex resolution. The VerteX Detector (VXD) for Belle II is therefore designed to have as little material as possible inside the acceptance region. Especially the innermost two layers, populated by the PiXel Detector (PXD), have to be ultra-thin. The PXD is based on DEpleted P-channel Field Effect Transistors (DEPFETs) with a thickness of only $75\,\rmμm$. Spatial resolution and hit efficiency of production detector modules were studied in beam tests performed at the DESY test beam facility. The spatial resolution was investigated as a function of the incidence angle and improvements due to charge sharing are demonstrated. The measured module performance is compatible with the requirements for Belle II.
△ Less
Submitted 22 January, 2021;
originally announced January 2021.
-
Artificial coherent states of light by multi-photon interference in a single-photon stream
Authors:
P. Steindl,
H. Snijders,
G. Westra,
E. Hissink,
K. Iakovlev,
S. Polla,
J. A. Frey,
J. Norman,
A. C. Gossard,
J. E. Bowers,
D. Bouwmeester,
W. Löffler
Abstract:
Coherent optical states consist of a quantum superposition of different photon number (Fock) states, but because they do not form an orthogonal basis, no photon number states can be obtained from it by linear optics. Here we demonstrate the reverse, by manipulating a random continuous single-photon stream using quantum interference in an optical Sagnac loop, we create engineered quantum states of…
▽ More
Coherent optical states consist of a quantum superposition of different photon number (Fock) states, but because they do not form an orthogonal basis, no photon number states can be obtained from it by linear optics. Here we demonstrate the reverse, by manipulating a random continuous single-photon stream using quantum interference in an optical Sagnac loop, we create engineered quantum states of light with tunable photon statistics, including approximate weak coherent states. We demonstrate this experimentally using a true single-photon stream produced by a semiconductor quantum dot in an optical microcavity, and show that we can obtain light with $g^{(2)}(0)\rightarrow1$ in agreement with our theory, which can only be explained by quantum interference of at least 3 photons. The produced artificial light states are, however, much more complex than coherent states, containing quantum entanglement of photons, making them a resource for multi-photon entanglement.
△ Less
Submitted 11 April, 2021; v1 submitted 29 October, 2020;
originally announced October 2020.
-
Extended polarized semiclassical model for quantum-dot cavity QED and its application to single-photon sources
Authors:
H. J. Snijders,
D. N. L. Kok,
M. F. van de Stolpe,
J. A. Frey,
J. Norman,
A. C. Gossard,
J. E. Bowers,
M. P. van Exter,
D. Bouwmeester,
W. Löffler
Abstract:
We present a simple extension of the semi-classical model for a two-level system in a cavity, in order to incorporate multiple polarized transitions, such as those appearing in neutral and charged quantum dots (QDs), and two nondegenerate linearly polarized cavity modes. We verify the model by exact quantum master equation calculations, and experimentally using a neutral QD in a polarization non-d…
▽ More
We present a simple extension of the semi-classical model for a two-level system in a cavity, in order to incorporate multiple polarized transitions, such as those appearing in neutral and charged quantum dots (QDs), and two nondegenerate linearly polarized cavity modes. We verify the model by exact quantum master equation calculations, and experimentally using a neutral QD in a polarization non-degenerate micro-cavity, in both cases we observe excellent agreement. Finally, the usefulness of this approach is demonstrated by optimizing a single-photon source based on polarization postselection, where we find an increase in the brightness for optimal polarization conditions as predicted by the model.
△ Less
Submitted 5 May, 2020; v1 submitted 26 November, 2018;
originally announced November 2018.
-
Electro-optic polarization tuning of microcavities with a single quantum dot
Authors:
J. A. Frey,
H. J. Snijders,
J. Norman,
A. C. Gossard,
J. E. Bowers,
W. Loffler,
D. Bouwmeester
Abstract:
We present an oxide aperture microcavity with embedded quantum dots that utilizes a three contact design to independently tune the quantum dot wavelength and birefringence of the cavity modes. A polarization splitting tuning of $\sim$5 GHz is observed. For typical microcavity polarization splittings, the method can be used to achieve perfect polarization degeneracy that is required for many polari…
▽ More
We present an oxide aperture microcavity with embedded quantum dots that utilizes a three contact design to independently tune the quantum dot wavelength and birefringence of the cavity modes. A polarization splitting tuning of $\sim$5 GHz is observed. For typical microcavity polarization splittings, the method can be used to achieve perfect polarization degeneracy that is required for many polarization-based implementations of photonic quantum gates. The embedded quantum dot wavelength can be tuned into resonance with the cavity, independent of the polarization tuning.
△ Less
Submitted 9 May, 2018;
originally announced May 2018.
-
A fiber coupled cavity QED source of identical single photons
Authors:
H. J. Snijders,
J. A. Frey,
J. Norman,
V. P. Post,
A. C. Gossard,
J. E. Bowers,
M. P. van Exter,
W. Löffler,
D. Bouwmeester
Abstract:
A high-fidelity source of identical single photons is essential for numerous quantum technologies such as quantum repeaters and optical quantum information processing. Hallmarks thereof are a near-unity single-photon purity, near-unity indistinguishability of consecutively emitted photons, and high brightness through a near-unity number of photons per time bin. In order to embed such sources in qu…
▽ More
A high-fidelity source of identical single photons is essential for numerous quantum technologies such as quantum repeaters and optical quantum information processing. Hallmarks thereof are a near-unity single-photon purity, near-unity indistinguishability of consecutively emitted photons, and high brightness through a near-unity number of photons per time bin. In order to embed such sources in quantum networks, optical fiber integration is essential but complicated by cryogenic compatability and noise. Here we demonstrate a resonantly pumped, quantum dot (QD) based, transmission operated, single-mode fiber coupled single photon source with a purity of 97%, indistinguishability of 90%, and a brightness of 17%. This is achieved by deploying a unique micropillar cavity design in a closed-cycle cryostat, which is operated using a through-fiber cross-polarization technique to remove the pump laser light from the resonantly scattered single photons. These results pave the way for fully fiber integrated photonic quantum networks, as our technology is equally applicable for cavity-QED based photonic quantum gates.
△ Less
Submitted 16 May, 2017;
originally announced May 2017.
-
Radiation length imaging with high resolution telescopes
Authors:
U. Stolzenberg,
A. Frey,
B. Schwenker,
P. Wieduwilt,
C. Marinas,
F. Lütticke
Abstract:
The construction of low mass vertex detectors with a high level of system integration is of great interest for next generation collider experiments. Radiation length images with a sufficient spatial resolution can be used to measure and disentangle complex radiation length $X$/$X_0$ profiles and contribute to the understanding of vertex detector systems. Test beam experiments with multi GeV partic…
▽ More
The construction of low mass vertex detectors with a high level of system integration is of great interest for next generation collider experiments. Radiation length images with a sufficient spatial resolution can be used to measure and disentangle complex radiation length $X$/$X_0$ profiles and contribute to the understanding of vertex detector systems. Test beam experiments with multi GeV particle beams and high-resolution tracking telescopes provide an opportunity to obtain precise 2D images of the radiation length of thin planar objects. At the heart of the $X$/$X_0$ imaging is a spatially resolved measurement of the scattering angles of particles traversing the object under study. The main challenges are the alignment of the reference telescope and the calibration of its angular resolution. In order to demonstrate the capabilities of $X$/$X_0$ imaging, a test beam experiment has been conducted. The devices under test were two mechanical prototype modules of the Belle II vertex detector. A data sample of 100 million tracks at $4\, \mathrm{GeV}$ has been collected, which is sufficient to resolve complex material profiles on the $30\,μ$m scale.
△ Less
Submitted 8 September, 2016;
originally announced September 2016.
-
Purification of a single photon nonlinearity
Authors:
H. Snijders,
J. A. Frey,
J. Norman,
M. P. Bakker,
A. Gossard,
J. E. Bowers,
M. P. van Exter,
D. Bouwmeester,
W. Löffler
Abstract:
We show that the lifetime-reduced fidelity of a semiconductor quantum dot-cavity single photon nonlinearity can be restored by polarization pre- and postselection. This is realized with a polarization degenerate microcavity in the weak coupling regime, where an output polarizer enables quantum interference of the two orthogonally polarized transmission amplitudes. This allows us to transform incid…
▽ More
We show that the lifetime-reduced fidelity of a semiconductor quantum dot-cavity single photon nonlinearity can be restored by polarization pre- and postselection. This is realized with a polarization degenerate microcavity in the weak coupling regime, where an output polarizer enables quantum interference of the two orthogonally polarized transmission amplitudes. This allows us to transform incident coherent light into a stream of strongly correlated photons with a second-order correlation function of g2(0)~40, larger than previous experimental results even in the strong-coupling regime. This purification technique might also be useful to improve the fidelity of quantum dot based logic gates.
△ Less
Submitted 2 April, 2016;
originally announced April 2016.
-
Physical limitations to the spatial resolution of solid-state detectors
Authors:
M. Boronat,
C. Marinas,
A. Frey,
I. Garcia,
B. Schwenker,
M. Vos,
F. Wilk
Abstract:
In this paper we explore the effect of $δ$-ray emission, fluctuations in th e signal deposition on the detection of charged particles in silicon-based detec tors. We show that these two effects ultimately limit the resolution that can be achieved by interpolation of the signal in finely segmented position-sensitive solid-state devices.
In this paper we explore the effect of $δ$-ray emission, fluctuations in th e signal deposition on the detection of charged particles in silicon-based detec tors. We show that these two effects ultimately limit the resolution that can be achieved by interpolation of the signal in finely segmented position-sensitive solid-state devices.
△ Less
Submitted 10 November, 2014; v1 submitted 17 April, 2014;
originally announced April 2014.
-
DEPFET active pixel detectors for a future linear $e^+e^-$ collider
Authors:
O. Alonso,
R. Casanova,
A. Dieguez,
J. Dingfelder,
T. Hemperek,
T. Kishishita amd T. Kleinohl,
M. Koch,
H. Krueger,
M. Lemarenko,
F. Luetticke,
C. Marinas,
M. Schnell,
N. Wermes,
A. Campbell,
T. Ferber,
C. Kleinwort,
C. Niebuhr,
Y. Soloviev,
M. Steder,
R. Volkenborn,
S. Yaschenko,
P. Fischer,
C. Kreidl,
I. Peric,
J. Knopf
, et al. (62 additional authors not shown)
Abstract:
The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a senso…
▽ More
The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a sensor thickness of 50-75 $\mathrm{\mathbf{μm}}$. ASICs have been designed and produced to operate a DEPFET pixel detector with the required read-out speed. A complete detector concept is being developed, including solutions for mechanical support, cooling and services. In this paper the status of DEPFET R & D project is reviewed in the light of the requirements of the vertex detector at a future linear $\mathbf{e^+ e^-}$ collider.
△ Less
Submitted 10 December, 2012;
originally announced December 2012.
-
Electromagnetic response of a highly granular hadronic calorimeter
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
Y. Mikami,
N. K. Watson T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward W. Yan
, et al. (142 additional authors not shown)
Abstract:
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individuall…
▽ More
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM).
A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes.
The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described.
△ Less
Submitted 8 June, 2011; v1 submitted 20 December, 2010;
originally announced December 2010.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.
-
Study of the interactions of pions in the CALICE silicon-tungsten calorimeter prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Ribon,
V. Uzhinskiy,
M. Benyamna,
C. Cârloganu,
F. Fehr,
P. Gay,
G. C. Blazey,
D. Chakraborty
, et al. (133 additional authors not shown)
Abstract:
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the…
▽ More
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the design of a full-sized detector. The interactions of pions in the Si-W calorimeter are therefore confronted with the predictions of various physical models implemented in the GEANT4 simulation framework.
△ Less
Submitted 28 April, 2010;
originally announced April 2010.