In beam performances of the MIMOSIS-2.1 CMOS Monolithic Active Pixel Sensor
Authors:
M. Deveaux,
Ali-Murteza Altingun,
Julio Andary,
Benedict Arnoldi-Meadows,
Jerome Baudot,
Gregory Bertolone,
Auguste Besson,
Norbert Bialas,
Christopher Braun,
Roma Bugiel,
Gilles Claus,
Claude Colledani,
Hasan Darwish,
Andrei Dorokhov,
Guy Dozière,
Ziad El Bitar,
Ingo Fröhlich,
Mathieu Goffe,
Benedikt Gutsche,
Abdelkader Himmi,
Christine Hu-Guo,
Kimmo Jaaskelainen,
Oliver Keller,
Michal Koziel,
Franz Matejcek
, et al. (13 additional authors not shown)
Abstract:
MIMOSIS is a CMOS Monolithic Active Pixel Sensor developed to equip the Micro Vertex Detector of the Compressed Baryonic Matter (CBM) experiment at FAIR/GSI. The sensor will combine an excellent spatial precision of $5~μm$ with a time resolution of $5~μs$ and provide a peak hit rate capability of $\mathrm{\sim 80~ MHz/cm^2}$. To fulfill its task, MIMOSIS will have to withstand ionising radiation d…
▽ More
MIMOSIS is a CMOS Monolithic Active Pixel Sensor developed to equip the Micro Vertex Detector of the Compressed Baryonic Matter (CBM) experiment at FAIR/GSI. The sensor will combine an excellent spatial precision of $5~μm$ with a time resolution of $5~μs$ and provide a peak hit rate capability of $\mathrm{\sim 80~ MHz/cm^2}$. To fulfill its task, MIMOSIS will have to withstand ionising radiation doses of $\sim 5~ \mathrm{MRad}$ and fluences of $\sim 7 \times 10^{13}~\mathrm{n_{eq}/cm^2}$ per year of operation.
This paper introduces the reticle size full feature sensor prototype MIMOSIS-2.1, which was improved with respect to earlier prototypes by adding on-chip grouping circuts and by improving the analog power grid. Moreover, it features for a first time a $50~μm$ epitaxial layer, which is found to improve the performances of the non-irradiated device significantly. We discuss the in beam sensor performances as measured during beam tests at the CERN-SPS.
△ Less
Submitted 7 February, 2025;
originally announced February 2025.
-
Integration Concept of the CBM Micro Vertex Detector
Authors:
Franz Matejcek,
Ali-Murteza Altingun,
Julio Andary,
Benedict Arnoldi-Meadows,
Jerome Baudot,
Gregory Bertolone,
Auguste Besson,
Norbert Bialas,
Christopher Braun,
Roma Bugiel,
Gilles Claus,
Claude Colledani,
Hasan Darwish,
Michael Deveaux,
Andrei Dorokhov,
Guy Dozière,
Ziad El Bitar,
Ingo Fröhlich,
Mathieu Goffe,
Benedikt Gutsche,
Abdelkader Himmi,
Christine Hu-Guo,
Kimmo Jaaskelainen,
Oliver Keller,
Michal Koziel
, et al. (13 additional authors not shown)
Abstract:
The Micro Vertex Detector (MVD) is the most upstream detector of the fixed-target Compressed Baryonic Matter Experiment (CBM) at the future Facility for Antiproton and Ion Research (FAIR). It enables high-precision low-momentum tracking in direct proximity of the target. Reaching the stringent requirements for the MVD, a material budget of~$0.3\,-\,0.5\%\,X_0$ per layer, operating the dedicated CM…
▽ More
The Micro Vertex Detector (MVD) is the most upstream detector of the fixed-target Compressed Baryonic Matter Experiment (CBM) at the future Facility for Antiproton and Ion Research (FAIR). It enables high-precision low-momentum tracking in direct proximity of the target. Reaching the stringent requirements for the MVD, a material budget of~$0.3\,-\,0.5\%\,X_0$ per layer, operating the dedicated CMOS MAPS~(`MIMOSIS') in the target vacuum, the strong magnetic dipole field, and a harsh radiation environment~(5\,Mrad, $7\times10^{13}\,n_{\text{eq}}/\text{cm}^2$ per CBM year), poses an unprecedented integration challenge. In this paper, the integration concept of the detector is be outlined, elaborating on the selection and preparation of materials, assembly procedures, and quality assessment steps in the ongoing preparation of pre-series production and detector commissioning in 2028.
△ Less
Submitted 7 February, 2025;
originally announced February 2025.
-
Prototype Design of a Timing and Fast Control system in the CBM Experiment
Authors:
V. Sidorenko,
I. Fröhlich,
W. F. J. Müller,
D. Emschermann,
S. Bähr,
C. Sturm,
J. Becker
Abstract:
The Compressed Baryonic Matter (CBM) experiment is designed to handle interaction rates of up to 10 MHz and up to 1 TB/s of raw data generated. With triggerless streaming data acquisition in the experiment and beam intensity fluctuations, it is expected that occasional data bursts will surpass bandwidth capabilities of the Data Acquisition System (DAQ) system. In order to preserve integrity of eve…
▽ More
The Compressed Baryonic Matter (CBM) experiment is designed to handle interaction rates of up to 10 MHz and up to 1 TB/s of raw data generated. With triggerless streaming data acquisition in the experiment and beam intensity fluctuations, it is expected that occasional data bursts will surpass bandwidth capabilities of the Data Acquisition System (DAQ) system. In order to preserve integrity of event data, the bandwidth of DAQ must be throttled in an organised way with minimum information loss. The Timing and Fast Control (TFC) system provides a latency-optimised datapath for throttling commands and distributes a system clock together with a global timestamp. This paper describes a prototype design of the system with focus on synchronisation and its evaluation.
△ Less
Submitted 20 December, 2021; v1 submitted 25 October, 2021;
originally announced October 2021.
-
Status of the vertex detector program of the CBM experiment at FAIR
Authors:
Philipp Klaus,
Michal Koziel,
Ole Artz,
Norbert Bialas,
Michael Deveaux,
Ingo Fröhlich,
Jan Michel,
Christian Müntz,
Roland Weirich,
Joachim Stroth
Abstract:
The Compressed Baryonic Matter Experiment (CBM) is one of the core experiments of the future FAIR facility (Darmstadt/Germany). The fixed-target experiment will explore the phase diagram of strongly interacting matter in the regime of high net baryon densities with numerous rare probes. The Micro Vertex Detector (MVD) will determine the secondary decay vertex of open charm particles with…
▽ More
The Compressed Baryonic Matter Experiment (CBM) is one of the core experiments of the future FAIR facility (Darmstadt/Germany). The fixed-target experiment will explore the phase diagram of strongly interacting matter in the regime of high net baryon densities with numerous rare probes. The Micro Vertex Detector (MVD) will determine the secondary decay vertex of open charm particles with $\sim 50~\rm μm$ precision, contribute to the background rejection in dielectron spectroscopy, and help to reconstruct neutral decay products of strange particles by means of missing mass identification. The MVD comprises four stations with 0.3 and $0.5\%~x/X_0$, which are placed between $5$ and $20~\rm cm$ downstream the target and inside vacuum. It will host highly-granular, next-generation Monolithic Active Pixel Sensors, with a spatial precision of $5\rm~μm$, a time resolution of $5 ~\rm μs$, and a peak rate capability of $\sim 700~\rm kHz/mm^2$. Moreover, a tolerance to $3\cdot10^{13}~\rm n_{eq}/cm^{2}$ and $\gtrsim 3~\rm Mrad$ are required. In this document, we summarize the status of sensor development, station prototyping, and the detector slow control.
△ Less
Submitted 19 October, 2018;
originally announced October 2018.
-
Radiation Tolerance of CMOS Monolithic Active Pixel Sensors with Self-Biased Pixels
Authors:
M. Deveaux,
S. Amar-Youcef,
A. Besson,
G. Claus,
C. Colledani,
M. Dorokhov,
C. Dritsa,
W. Dulinski,
I. Froehlich,
M. Goffe,
D. Grandjean,
S. Heini,
A. Himmi,
C. Hu,
K. Jaaskelainen,
C. Muentz,
A. Shabetai,
J. Stroth,
M. Szelezniak,
I. Valin,
M. Winter
Abstract:
CMOS Monolithic Active Pixel Sensors (MAPS) are proposed as a technology for various vertex detectors in nuclear and particle physics. We discuss the mechanisms of ionizing radiation damage on MAPS hosting the the dead time free, so-called self bias pixel. Moreover, we discuss radiation hardened sensor designs which allow operating detectors after exposing them to irradiation doses above 1 Mrad
CMOS Monolithic Active Pixel Sensors (MAPS) are proposed as a technology for various vertex detectors in nuclear and particle physics. We discuss the mechanisms of ionizing radiation damage on MAPS hosting the the dead time free, so-called self bias pixel. Moreover, we discuss radiation hardened sensor designs which allow operating detectors after exposing them to irradiation doses above 1 Mrad
△ Less
Submitted 28 August, 2009;
originally announced August 2009.