Time-domain Response of Supercapacitors using their Impedance Parameters and Fourier Series Decomposition of the Excitation Signal
Authors:
Anis Allagui,
Mohammed E. Fouda,
Ahmed Elwakil,
Costas Psychalinos
Abstract:
Supercapacitors are mostly recognized for their high power density capabilities and fast response time when compared to secondary batteries. However, computing their power in response to a given excitation using the standard formulæ of capacitors is misleading and erroneous because supercapacitors are actually non-ideal capacitive devices that cannot be characterized with a single constant capacit…
▽ More
Supercapacitors are mostly recognized for their high power density capabilities and fast response time when compared to secondary batteries. However, computing their power in response to a given excitation using the standard formulæ of capacitors is misleading and erroneous because supercapacitors are actually non-ideal capacitive devices that cannot be characterized with a single constant capacitance. In this study we show how to estimate accurately the time-domain power and energy of supercapacitors in response to any excitation signal represented in terms of its Fourier series coefficients with the sole knowledge of the frequency-domain impedance parameters of device. The presented theory is first verified and validated with simulations conducted on an equivalent fifth-order RC circuit emulating the behavior of a fractional circuit consisting of a resistance (Rs) in series with a constant phase element (CPE) of fractional impedance ZCPE = 1/Cαsα. Then we do the same for a commercial supercapacitor modeled as an Rs-CPE circuit, and subjected to both a periodic triangular voltage waveform and a random voltage excitation. The results are conclusive and very promising for adopting the proposed procedure to estimate the power and energy performance of supercapacitors in response to real-world charging and discharging signals.
△ Less
Submitted 30 January, 2023;
originally announced January 2023.
-
Thrust Enhancement and Degradation Mechanisms due to Self-Induced Vibrations in Bio-inspired Flying Robots
Authors:
Dipan Deb,
Kevin Huang,
Aakash Verma,
Moatasem Fouda,
Haithem E Taha
Abstract:
Whenever a flapping robot moves along a trajectory it experiences some vibration about its mean path. Even for a hovering case, a flier experiences such vibration due to the oscillatory nature of the aerodynamic forces. In this paper we have studied the effect of such vibration on hovering. We used two setups to measure thrust force generated by flapping robots. One involving loadcell, which does…
▽ More
Whenever a flapping robot moves along a trajectory it experiences some vibration about its mean path. Even for a hovering case, a flier experiences such vibration due to the oscillatory nature of the aerodynamic forces. In this paper we have studied the effect of such vibration on hovering. We used two setups to measure thrust force generated by flapping robots. One involving loadcell, which does not allow any kind of vibration. The other one involves a pendulum which allows vibration at a particular direction. We used two different flapping robots; one is a traditional flapping robot with two wings and the other one is a four wings robot which exploits clap and peel mechanism to generate thrust. We observed that the loadcell setup measures more thrust for the two wings model than the pendulum setup. The opposite trend was observed for the four wings model. We measured the vibration induced velocity using motion capture system. We used well known aerodynamic models to observe the effect of the vibration during the flapping cycle. To gain physical insight into the vibration affected flow field, we used smoke flow visualization at different instances during the flapping cycle. It revealed that the perturbation ebbs a jet effect in case of the two wings which leads to its adverse effect for thrust generation. On the contrary the perturbation enhances the clapping effect for the four wings robot, resulting favorable for thrust generation.
△ Less
Submitted 20 January, 2023;
originally announced January 2023.
-
AI Aided Noise Processing of Spintronic Based IoT Sensor for Magnetocardiography Application
Authors:
Attayeb Mohsen,
Muftah Al-Mahdawi,
Mostafa M. Fouda,
Mikihiko Oogane,
Yasuo Ando,
Zubair Md Fadlullah
Abstract:
As we are about to embark upon the highly hyped "Society 5.0", powered by the Internet of Things (IoT), traditional ways to monitor human heart signals for tracking cardio-vascular conditions are challenging, particularly in remote healthcare settings. On the merits of low power consumption, portability, and non-intrusiveness, there are no suitable IoT solutions that can provide information compar…
▽ More
As we are about to embark upon the highly hyped "Society 5.0", powered by the Internet of Things (IoT), traditional ways to monitor human heart signals for tracking cardio-vascular conditions are challenging, particularly in remote healthcare settings. On the merits of low power consumption, portability, and non-intrusiveness, there are no suitable IoT solutions that can provide information comparable to the conventional Electrocardiography (ECG). In this paper, we propose an IoT device utilizing a spintronic ultra-sensitive sensor that measures the magnetic fields produced by cardio-vascular electrical activity, i.e. Magentocardiography (MCG). After that, we treat the low-frequency noise generated by the sensors, which is also a challenge for most other sensors dealing with low-frequency bio-magnetic signals. Instead of relying on generic signal processing techniques such as averaging or filtering, we employ deep-learning training on bio-magnetic signals. Using an existing dataset of ECG records, MCG labels are synthetically constructed. A unique deep learning structure composed of combined Convolutional Neural Network (CNN) with Gated Recurrent Unit (GRU) is trained using the labeled data moving through a striding window, which is able to smartly capture and eliminate the noise features. Simulation results are reported to evaluate the effectiveness of the proposed method that demonstrates encouraging performance.
△ Less
Submitted 10 June, 2020; v1 submitted 8 November, 2019;
originally announced November 2019.
-
Fast-light Enhanced Brillouin Laser Based Active Fiber Optics Sensor for Simultaneous Measurement of Rotation and Acceleration
Authors:
Minchuan Zhou,
Zifan Zhou,
Mohamed Fouda,
Nicholas Condon,
Jacob Scheuer,
Selim M. Shahriar
Abstract:
We have developed a conceptual design for an Active Fast Light Fiber Optic Sensor (AFLIFOS) that can perform simultaneously or separately as a gyroscope (differential mode effect) and a sensor for acceleration, strain, and other common mode effects. Two Brillouin lasers in opposite directions and separated in frequency by several free spectral ranges are used for this sensor. By coupling two auxil…
▽ More
We have developed a conceptual design for an Active Fast Light Fiber Optic Sensor (AFLIFOS) that can perform simultaneously or separately as a gyroscope (differential mode effect) and a sensor for acceleration, strain, and other common mode effects. Two Brillouin lasers in opposite directions and separated in frequency by several free spectral ranges are used for this sensor. By coupling two auxiliary resonators to the primary fiber resonator, we produce superluminal effects for two laser modes. We develop a detailed theoretical model for optimizing the design of the AFLIFOS, and show that the enhancement factor of the sensitivity is $\sim{187}$ and $\sim{-187}$, respectively for the two Brillouin lasers under the optimized condition, when the effective change in perimeter of the primary fiber resonator is 0.1nm, corresponding to a rotation rate of 0.4 deg/sec for a ring resonator with radius 1m. It may be possible to get much higher enhancement by adjusting the parameters such as the perimeters and the coupling coefficients.
△ Less
Submitted 24 October, 2016;
originally announced October 2016.
-
All Optical Three Dimensional Spatio-Temporal Correlator for Automatic Event Recognition Using a Multiphoton Atomic System
Authors:
Mehjabin S. Monjur,
Mohamed F. Fouda,
Selim M. Shahriar
Abstract:
We describe an automatic event recognition (AER) system based on a three-dimensional spatio-temporal correlator (STC) that combines the techniques of holographic correlation and photon echo based temporal pattern recognition. The STC is shift invariant in space and time. It can be used to recognize rapidly an event (e.g., a short video clip) that may be present in a large video file, and determine…
▽ More
We describe an automatic event recognition (AER) system based on a three-dimensional spatio-temporal correlator (STC) that combines the techniques of holographic correlation and photon echo based temporal pattern recognition. The STC is shift invariant in space and time. It can be used to recognize rapidly an event (e.g., a short video clip) that may be present in a large video file, and determine the temporal location of the event. Using polar Mellin transform, it is possible to realize an STC that is also scale and rotation invariant spatially. Numerical simulation results of such a system are presented using quantum mechanical equations of evolution. For this simulation we have used the model of an idealized, decay-free two level system of atoms with an inhomogeneous broadening that is larger than the inverse of the temporal resolution of the data stream. We show how such a system can be realized by using a lambda-type three level system in atomic vapor, via adiabatic elimination of the intermediate state. We have also developed analytically a three dimensional transfer function of the system, and shown that it agrees closely with the results obtained via explicit simulation of the atomic response. The analytical transfer function can be used to determine the response of an STC very rapidly. In addition to the correlation signal, other nonlinear terms appear in the explicit numerical model. These terms are also verified by the analytical model. We describe how the AER can be operated in a manner such that the correlation signal remains unaffected by the additional nonlinear terms. We also show how such a practical STC can be realized using a combination of a porous-glass based Rb vapor cell, a holographic video disc, and a lithium niobate crystal.
△ Less
Submitted 5 June, 2016; v1 submitted 13 October, 2015;
originally announced October 2015.