Characterization of sealed (zero gas flow) RPCs under strong irradiation source
Authors:
A. Blanco,
Mário Carvalho,
Susete Fetal,
Luis Lopes,
Telmo Paes,
Joana Pinto,
Paulo Fonte
Abstract:
The phase-out of Hydrofluorocarbons (HFCs), due to their high Global Warming Potential (GWP), affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluorethane C2H2F4, has created operational difficulties on existing systems and imposes strict restrictions on its use in new systems. A possible solution to the problem is the substitution of this gas by others with a much lower GWP. T…
▽ More
The phase-out of Hydrofluorocarbons (HFCs), due to their high Global Warming Potential (GWP), affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluorethane C2H2F4, has created operational difficulties on existing systems and imposes strict restrictions on its use in new systems. A possible solution to the problem is the substitution of this gas by others with a much lower GWP. This approach has attracted the attention of an important part of the community in recent years.
But there could be another possibility, which is the construction of sealed chambers, i.e. chambers that do not need a continuous gas flow to operate (in a similar way to Geiger-Muller counters). This possibility would allow continuing to use HFCs or eventually other types of gases that are already banned. It would also greatly simplify the detector, not requiring the complex and expensive gas systems normally used. This simplification could be particularly relevant for outdoor applications, such as in Cosmic Ray experiments. This has motivated a new line of research and development on sealed RPCs: RPCs that do not require a continuous gas flow for their operation.
In this work we show the characterization of a sealed RPC plane exposed to an intense radiation source for about one month, with the aim of verifying, in an accelerated way, gas degradation effects that could compromise the operation of the detector. The results show no apparent degradation in any of the parameters studied, namely: efficiency, average charge and streamer probability. The exposure period corresponds, based on the accumulated charge, to approximately four years of natural Cosmic Ray radiation exposure (background signals generated by the detector itself), suggesting the feasibility of the application of this technology in Cosmic Ray experiments for extended periods of time.
△ Less
Submitted 20 February, 2025;
originally announced February 2025.
-
Large Amplitude Oscillatory Extension (LAOE) of dilute polymer solutions
Authors:
Steffen M. Recktenwald,
Thomas P. John,
Amy Q. Shen,
Robert J. Poole,
Cláudio P. Fonte,
Simon J. Haward
Abstract:
This study presents an experimental framework for large amplitude oscillatory extension (LAOE) to investigate nonlinear material properties of complex fluids. Using a microfluidic optimized shape cross-slot extensional rheometer, we generate approximately homogeneous planar extensional flows driven by programmable syringe pumps operating in oscillatory or pulsatile sinusoidal modes. Micro-particle…
▽ More
This study presents an experimental framework for large amplitude oscillatory extension (LAOE) to investigate nonlinear material properties of complex fluids. Using a microfluidic optimized shape cross-slot extensional rheometer, we generate approximately homogeneous planar extensional flows driven by programmable syringe pumps operating in oscillatory or pulsatile sinusoidal modes. Micro-particle image velocimetry and simultaneous pressure drop measurements are employed to analyze the time-dependent flow field and elastic stress response. For Newtonian fluids, a linear relationship between the applied strain rate and pressure drop is observed across a wide range of oscillation amplitudes and frequencies. In contrast, dilute polymer solutions exhibit significant deviations, with excess pressure drops and divergence between average strain rates along extension and compression axes during the LAOE cycle. By spanning a broad range of Weissenberg and Deborah numbers, we identify unique Lissajous curves and critical conditions for the onset of nonlinearities under oscillatory extension. Numerical simulations, assuming homogeneous flow, underpin the experimental findings, validating the robustness of our microfluidic approach. This study demonstrates the utility of oscillatory extensional flows for probing the nonlinear rheological behavior of soft materials, offering quantitative insights into their extensional properties under nonlinear flow conditions.
△ Less
Submitted 21 January, 2025;
originally announced January 2025.
-
Uncertainty in Elastic Turbulence
Authors:
Jack R. C. King,
Robert J. Poole,
Cláudio P. Fonte,
Steven J. Lind
Abstract:
Elastic turbulence can lead to to increased flow resistance, mixing and heat transfer. Its control -- either suppression or promotion -- has significant potential, and there is a concerted ongoing effort by the community to improve our understanding. Here we explore the dynamics of uncertainty in elastic turbulence, inspired by an approach recently applied to inertial turbulence in Ge et al. (2023…
▽ More
Elastic turbulence can lead to to increased flow resistance, mixing and heat transfer. Its control -- either suppression or promotion -- has significant potential, and there is a concerted ongoing effort by the community to improve our understanding. Here we explore the dynamics of uncertainty in elastic turbulence, inspired by an approach recently applied to inertial turbulence in Ge et al. (2023) \textit{J. Fluid Mech.} 977:A17. We derive equations for the evolution of uncertainty measures, yielding insight on uncertainty growth mechanisms. Through numerical experiments, we identify four regimes of uncertainty evolution, characterised by I) rapid transfer to large scales, with large scale growth rates of $τ^{6}$ (where $τ$ represents time), II) a dissipative reduction of uncertainty, III) exponential growth at all scales, and IV) saturation. These regimes are governed by the interplay between advective and polymeric contributions (which tend to amplify uncertainty), viscous, relaxation and dissipation effects (which reduce uncertainty), and inertial contributions. In elastic turbulence, reducing Reynolds number increases uncertainty at short times, but does not significantly influence the growth of uncertainty at later times. At late times, the growth of uncertainty increases with Weissenberg number, with decreasing polymeric diffusivity, and with the logarithm of the maximum length scale, as large flow features adjust the balance of advective and relaxation effects. These findings provide insight into the dynamics of elastic turbulence, offering a new approach for the analysis of viscoelastic flow instabilities.
△ Less
Submitted 16 January, 2025;
originally announced January 2025.
-
Resistive Plate Chambers for brain PET imaging and particle tracking and timing (TOF-tracker)
Authors:
Paulo Fonte,
Luís Lopes,
Filomena M. C. Clemêncio,
Miguel Couceiro,
Susete Fetal,
Custódio F. M. Loureiro,
Jan Michel,
João Saraiva,
Michael Traxler,
Antero Abrunhosa,
Alberto Blanco,
Miguel Castelo-Branco
Abstract:
In this work we explore readout architectures for the simultaneous high-resolution timing and bidimensional tracking of charged particles with Resistive Plate Chambers (TOF-tracker) and for the accurate detection of gamma rays for PET imaging. On 625 $cm^2$ of active area we obtained a time resolution of 61 ps $σ$ and bidimensional position resolution below 150 $μ$m $σ$ for the tracking and timing…
▽ More
In this work we explore readout architectures for the simultaneous high-resolution timing and bidimensional tracking of charged particles with Resistive Plate Chambers (TOF-tracker) and for the accurate detection of gamma rays for PET imaging. On 625 $cm^2$ of active area we obtained a time resolution of 61 ps $σ$ and bidimensional position resolution below 150 $μ$m $σ$ for the tracking and timing of charged particles from cosmic rays. An intrinsic precision of 0.49 mm FWHM was determined for the localization of a small $β^+$ source via the detection of its annihilation radiation.
△ Less
Submitted 13 January, 2025;
originally announced January 2025.
-
A new complex fluid flow phenomenon: Bubbles-on-a-String
Authors:
Thomas P. John,
Jack R. C. King,
Steven J. Lind,
Cláudio P. Fonte
Abstract:
A liquid jet plunging into a quiescent bath of the same liquid is a fundamental fluid mechanical problem underpinning a range of processes in industry and the natural world. Significant attention has been given to the study of plunging laminar Newtonian jets and the associated air entrainment that can occur. However, there have been very few (if any) studies devoted to the equivalent case for non-…
▽ More
A liquid jet plunging into a quiescent bath of the same liquid is a fundamental fluid mechanical problem underpinning a range of processes in industry and the natural world. Significant attention has been given to the study of plunging laminar Newtonian jets and the associated air entrainment that can occur. However, there have been very few (if any) studies devoted to the equivalent case for non-Newtonian viscoelastic liquids. Here we consider the laminar plunging and associated air entrainment of a shear thinning viscoelastic jet into a still bath of the same liquid. We describe a previously unreported phenomenon, that we call ``bubbles-on-a-string'' (BUoaS), consisting of multiple stable toroidal bubbles rising co-axially around the submerged jet. In a qualitative sense, this new observation is akin to an inverse version of the well-known rheological phenomenon ``beads-on-a-string''. The BUoaS phenomenon is stable and repeatable and can be reproduced to a lesser extent in Newtonian surfactant solutions, indicating that low surface tension is key, but non-Newtonian rheology seems likely to provide the most favourable conditions for the onset of the phenomenon. A full characterisation and detailed study of this behaviour with accompanying numerical simulation is to follow in an upcoming publication.
△ Less
Submitted 20 January, 2025; v1 submitted 18 September, 2024;
originally announced September 2024.
-
Stability studies of sealed Resistive Plate Chambers
Authors:
A. Blanco,
P. Fonte,
L. Lopes,
M. Pimenta
Abstract:
The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems and imposes strong restrictions on its use in new systems.
This has motivated a new line of R\&D on sealed RPCs: RPCs that do not require a continuous gas flow…
▽ More
The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems and imposes strong restrictions on its use in new systems.
This has motivated a new line of R\&D on sealed RPCs: RPCs that do not require a continuous gas flow for their operation and dispense the use of very complex and expensive re-circulation and/or recycling gas systems. At the moment it is not clear whether this solution can cover all fields of application normally allocated to RPCs, but it seems that it could be considered as a valid option for low particle flux triggering/tracking of particles, e.g. in cosmic ray or rare event experiments.
In this work, we demonstrate the feasibility of a small telescope for atmospheric muon tracking consisting of four $300$~x~$300$~mm$^2$ sealed RPCs with gas gap widths of $1$~mm, $1.5$~mm and $2$~mm. The results suggest that it is possible to operate this type of detectors for extended periods of time (more than five months) with its main characteristics, efficiency, average charge and streamer probability, without apparent degradation and similar to a RPC operated in continuous gas flow.
△ Less
Submitted 28 February, 2024;
originally announced February 2024.
-
In-beam test results of an RPC-based module for position-sensitive neutron detectors with timing readout
Authors:
G. Canezin,
L. M. S. Margato,
A. Morozov,
A. Blanco,
J. Saraiva,
L. Lopes,
P. Fonte,
Chung Chuan Lai,
Per-Olof Svensson,
G. Markaj,
Florian M. Piegsa
Abstract:
Recently we have proposed a new concept of a thermal neutron detector based on resistive plate chambers and 10B4C solid neutron converters, enabling to readout with high resolution in both the 3D position of neutron capture and the neutron time of flight (ToF). In this paper, we report the results of the first beam tests conducted with a new neutron RPC detection module, coupled to the position re…
▽ More
Recently we have proposed a new concept of a thermal neutron detector based on resistive plate chambers and 10B4C solid neutron converters, enabling to readout with high resolution in both the 3D position of neutron capture and the neutron time of flight (ToF). In this paper, we report the results of the first beam tests conducted with a new neutron RPC detection module, coupled to the position readout units of a new design. The main focus is on the measurements of the neutron ToF and identification of the converter layer where the neutron is captured, giving the position along the beam direction.
△ Less
Submitted 23 February, 2024;
originally announced February 2024.
-
A comparison between the FENE-P and sPTT constitutive models in Large Amplitude Oscillatory Shear (LAOS)
Authors:
Thomas P John,
Robert J Poole,
Adam Kowalski,
Claudio P Fonte
Abstract:
The FENE-P and sPTT viscoelastic models are widely used for modelling of complex fluids. Although they are derived from distinct micro-structural theories, these models can become mathematically identical in steady and homogeneous flows with a particular choice of the value of the model parameters. However, even with this choice of parameter values, the model responses are known to differ from eac…
▽ More
The FENE-P and sPTT viscoelastic models are widely used for modelling of complex fluids. Although they are derived from distinct micro-structural theories, these models can become mathematically identical in steady and homogeneous flows with a particular choice of the value of the model parameters. However, even with this choice of parameter values, the model responses are known to differ from each other in transient flows. In this work, we investigate the responses of the FENE-P and sPTT constitutive models in Large Amplitude Oscillatory Shear (LAOS). In steady-shear, the shear stress scales with the non-dimensional group $Wi/(aL) \ (Wi\sqrtε)$ for the FENE-P (sPTT) model, where $Wi$ is the Weissenberg number, $L^2$ is the limit of extensibility in the FENE-P model ($a$ being $L^2/(L^2-3)$) and $ε$ is the extensibility parameter in the sPTT model. Our numerical and analytical results show that, in LAOS, the FENE-P model only shows this universality for large values of $L^2$ whereas the sPTT model shows this universality for all values of$ε$. In the strongly non-linear region, there is a drastic difference between the responses of the two models, with the FENE-P model exhibiting strong shear stress overshoots which manifest as self-intersecting secondary loops in the viscous Lissajous curves. We quantify the non-linearity exhibited by each constitutive model using the Sequence of Physical Processes framework. Despite the high degree of non-linearity exhibited by the FENE-P model, we also show using fully non-linear 1D simulations that it does not shear band in LAOS within the range of conditions studied.
△ Less
Submitted 1 September, 2023; v1 submitted 31 August, 2023;
originally announced August 2023.
-
Timing resistive plate chambers for thermal neutron detection with 3D position sensitivity
Authors:
L. M. S. Margato,
G. Canezin,
A. Morozov,
A. Blanco,
J. Saraiva,
L. Lopes,
P. Fonte
Abstract:
An optimized design of a neutron detector based on timing RPCs (Resistive Plate Chambers) with boron-10 neutron converters is presented. The detector is composed of a stack of ten double gap RPCs with aluminium cathode plates coated on both sides with $^{10}B_{4}C$. This design enables simultaneous determination with high accuracy of both the neutron time-of-flight (down to ns resolution) and the…
▽ More
An optimized design of a neutron detector based on timing RPCs (Resistive Plate Chambers) with boron-10 neutron converters is presented. The detector is composed of a stack of ten double gap RPCs with aluminium cathode plates coated on both sides with $^{10}B_{4}C$. This design enables simultaneous determination with high accuracy of both the neutron time-of-flight (down to ns resolution) and the interaction position in 3D (down to 0.25 mm resolution across and ~1 mm along the beam). It is shown that the detection efficiency can approach 60% for neutrons with $λ$ = 4.7 Ȧ. A new geometry with less material budget is introduced for the signal pick-up strip arrays. The results of simulation-based optimization of the design are reported considering the trade-off between the detection efficiency, the count rate capability and the amount of elastic scattering on the detector components.
△ Less
Submitted 6 March, 2023;
originally announced March 2023.
-
The new HADES ToF Forward Detector
Authors:
A. Blanco,
P. Fonte,
L. Lopes,
J. Saraiva
Abstract:
The High-Acceptance DiElectron Spectrometer (HADES) at GSI Darmstadt consists of a 6-coil toroidal magnet centered on the beam axis and six identical detection sections located between the coils and covering polar angles between $18^\circ$ and $85^\circ$. The physics aims include the study of the properties of hot and dense hadronic matter as well as elementary and pion-induced reactions.
To inc…
▽ More
The High-Acceptance DiElectron Spectrometer (HADES) at GSI Darmstadt consists of a 6-coil toroidal magnet centered on the beam axis and six identical detection sections located between the coils and covering polar angles between $18^\circ$ and $85^\circ$. The physics aims include the study of the properties of hot and dense hadronic matter as well as elementary and pion-induced reactions.
To increase the acceptance of HADES at very low polar angles in the forward region, between $0.5^\circ$ and $7^\circ$, a new detector, the Forward Detector (FD), has been built. The FD is composed of a tracking and a Time Of Flight (TOF) detector based on Resistive Plate Chamber (RPC) technology. The TOF detector, covering an area of around $2$ m$^2$, is composed by $128$ strip-like shielded RPC cells, with two different widths $22$ mm and $44$ mm and $750$ mm length distributed in four modules symmetrically placed around the beam axis. Each cell is composed by four gas gaps, $0.270$ mm, delimited by three ($2$ mm) aluminum and two ($1$ mm) glass electrodes. In order to cope with an expected maximum particle load of around $400$ Hz/cm$^{2}$, close to the beam axis, the detector is operated above room temperature in order to decrease the resistivity of the glass and increase the count rate capability.
Details of the system construction and results concerning timing precision are described in this communication. The detector was operated at $31.5^\circ$C with a maximum particle load of around $600$ Hz/cm$^2$ during a production beam time for six weeks in early $2022$ showing an average time precision of around $80$ ps.
△ Less
Submitted 5 December, 2022;
originally announced December 2022.
-
An RPC-PET brain scanner demonstrator: first results
Authors:
Paulo Fonte,
Luís Lopes,
Rui Alves,
Nuno Carolino,
Paulo Crespo,
Miguel Couceiro,
Orlando Cunha,
Nuno Dias,
Nuno C. Ferreira,
Susete Fetal,
Ana L. Lopes,
Jan Michel,
Jorge Moreira,
Américo Pereira,
João Saraiva,
Carlos Silva,
Magda Silva,
Michael Traxler,
Antero Abrunhosa,
Alberto Blanco,
Miguel Castelo-Branco,
Mário Pimenta
Abstract:
We present first results from a Positron Emission Tomography (PET) scanner demonstrator based on Resistive Plate Chambers and specialized for brain imaging. The device features a 30 cm wide cubic field-of-view and each detector comprises 40 gas gaps with 3D location of the interaction point of the photon. Besides other imagery, we show that the reconstructed image resolution, as evaluated by a hot…
▽ More
We present first results from a Positron Emission Tomography (PET) scanner demonstrator based on Resistive Plate Chambers and specialized for brain imaging. The device features a 30 cm wide cubic field-of-view and each detector comprises 40 gas gaps with 3D location of the interaction point of the photon. Besides other imagery, we show that the reconstructed image resolution, as evaluated by a hot-rod phantom, is sub-millimetric, which is beyond the state-of-the-art of the standard PET technology for this application.
△ Less
Submitted 10 November, 2022;
originally announced November 2022.
-
Improving count rate capability of timing RPCs by increasing the detector working temperature
Authors:
A. Blanco,
P. Fonte,
L. Lopes,
J. Saraiva
Abstract:
This communication describes test beam results, focusing on detection efficiency and timing precision, of common float glass timing Resistive Plate Chambers (tRPCs) exposed to a $2.7$~GeV proton beam and operated at above ambient temperature in order to increase the count rate capability of the chambers, by exploiting the reduction in the resistivity of the glass electrodes. Results suggest that t…
▽ More
This communication describes test beam results, focusing on detection efficiency and timing precision, of common float glass timing Resistive Plate Chambers (tRPCs) exposed to a $2.7$~GeV proton beam and operated at above ambient temperature in order to increase the count rate capability of the chambers, by exploiting the reduction in the resistivity of the glass electrodes. Results suggest that the count rate capability can be extended at least up to $1500~Hz/cm^2$ when the detector is operated at $40.6^{\circ}$C without noticeable loss of efficiency or timing precision degradation with values of $90\%$ and $100$~ps, respectively, for this specific timing RPC arrangement.
△ Less
Submitted 24 June, 2022;
originally announced June 2022.
-
Towards high-rate RPC-based thermal neutron detectors using low-resistivity electrodes
Authors:
L. M. S. Margato,
A. Morozov,
A. Blanco,
P. Fonte,
L. Lopes,
J. Saraiva,
K. Zeitelhack,
R. Hall-Wilton,
C. Höglund,
L. Robinson,
P. Svensson,
L. Naumann,
K. Roemer,
D. Stach,
Th. Wilpert
Abstract:
We present experimental results on the counting rate measurements for several single-gap $^{10}$B lined resistive plate chambers ($^{10}$B-RPCs) with anodes made from standard float glass, low resistivity glass and ceramic. The measurements were performed at the V17 monochromatic neutron beamline (3.35 Ȧ) at the Helmholtz-Zentrum Berlin. For the $^{10}$B-RPCs with 0.28 mm thick float glass a maxim…
▽ More
We present experimental results on the counting rate measurements for several single-gap $^{10}$B lined resistive plate chambers ($^{10}$B-RPCs) with anodes made from standard float glass, low resistivity glass and ceramic. The measurements were performed at the V17 monochromatic neutron beamline (3.35 Ȧ) at the Helmholtz-Zentrum Berlin. For the $^{10}$B-RPCs with 0.28 mm thick float glass a maximum counting rate density of about $8\times 10^{3}$ $Hz/cm^{2}$ was obtained. In the case of low resistivity glass and ceramic, the counting rate density did not deviate from linear dependence on the neutron flux up to the maximum flux available at this beamline and exceeded a value of $3\times 10^{4}$ $Hz/cm^{2}$.
△ Less
Submitted 1 April, 2021;
originally announced April 2021.
-
Towards Sealed Resistive Plate Chambers
Authors:
L. Lopes P. Assis,
A. Blanco,
P. Fonte,
M. Pimenta
Abstract:
The mitigation of human-induced climate change is of crucial importance for the sustainability of humankind. For this aim the RPC community has exerted considerable effort over the last decade to reduce the emission of greenhouse gases from our detectors. These included searching for new eco-friendly gases, implementing recovery and/or recirculation systems, improving gastightness and using new ma…
▽ More
The mitigation of human-induced climate change is of crucial importance for the sustainability of humankind. For this aim the RPC community has exerted considerable effort over the last decade to reduce the emission of greenhouse gases from our detectors. These included searching for new eco-friendly gases, implementing recovery and/or recirculation systems, improving gastightness and using new materials and approaches in detector conception and operation for the reduction of gas flow rates.
Along this line of work, we present here an RPC architecture aimed at a dramatic reduction of gas use in chambers meant for low-rate operation. Two chambers were tested for more than six months with zero gas flow showing no evidence of time-related effects, allowing to consider that permanently sealed RPCs may be within reach, with obvious practical and environmental advantages.
△ Less
Submitted 15 June, 2020;
originally announced June 2020.
-
Prototype of an affordable pressure-controlled emergency mechanical ventilator for COVID-19
Authors:
Américo Pereira,
Luís Lopes,
Paulo Fonte,
Pedro Póvoa,
Telmo G. Santos,
Alberto Martinho,
Ângela Neves,
António Bugalho,
António Gabriel-Santos,
Gonçalo Gaspar Bentes Pimenta,
João Goês,
João Martins,
João Pedro Oliveira,
José Paulo Santos,
Luís C. Gil,
Miguel Onofre Domingues,
Orlando Cunha,
Pedro Pinheiro de Sousa,
Tiago A. Rodrigues,
Valdemar R. Duarte,
Antero Abrunhosa,
António Grilo,
João Agostinho do Nascimento,
Mário Pimenta
Abstract:
We present a viable prototype of a simple mechanical ventilator intended as a last resort to ventilate COVID-19 patients. The prototype implements the pressure-controlled continuous mandatory ventilation mode (PC-CMV) with settable breathing rates, inspiration/expiration time ratios and FiO2 modulation. Although safe, the design aims to minimize the use of technical components and those used are c…
▽ More
We present a viable prototype of a simple mechanical ventilator intended as a last resort to ventilate COVID-19 patients. The prototype implements the pressure-controlled continuous mandatory ventilation mode (PC-CMV) with settable breathing rates, inspiration/expiration time ratios and FiO2 modulation. Although safe, the design aims to minimize the use of technical components and those used are common in industry, so its construction may be possible in times of logistical shortage or disruption or in areas with reduced access to technical materials and at a moderate cost, affordable to lower income countries. Most of the device can be manufactured by modest technical means and construction plans are provided.
△ Less
Submitted 21 July, 2020; v1 submitted 1 April, 2020;
originally announced April 2020.
-
SND@LHC
Authors:
SHiP Collaboration,
C. Ahdida,
A. Akmete,
R. Albanese,
A. Alexandrov,
M. Andreini,
A. Anokhina,
S. Aoki,
G. Arduini,
E. Atkin,
N. Azorskiy,
J. J. Back,
A. Bagulya,
F. Baaltasar Dos Santos,
A. Baranov,
F. Bardou,
G. J. Barker,
M. Battistin,
J. Bauche,
A. Bay,
V. Bayliss,
G. Bencivenni,
A. Y. Berdnikov,
Y. A. Berdnikov,
M. Bertani
, et al. (319 additional authors not shown)
Abstract:
We propose to build and operate a detector that, for the first time, will measure the process $pp\toνX$ at the LHC and search for feebly interacting particles (FIPs) in an unexplored domain. The TI18 tunnel has been identified as a suitable site to perform these measurements due to very low machine-induced background. The detector will be off-axis with respect to the ATLAS interaction point (IP1)…
▽ More
We propose to build and operate a detector that, for the first time, will measure the process $pp\toνX$ at the LHC and search for feebly interacting particles (FIPs) in an unexplored domain. The TI18 tunnel has been identified as a suitable site to perform these measurements due to very low machine-induced background. The detector will be off-axis with respect to the ATLAS interaction point (IP1) and, given the pseudo-rapidity range accessible, the corresponding neutrinos will mostly come from charm decays: the proposed experiment will thus make the first test of the heavy flavour production in a pseudo-rapidity range that is not accessible by the current LHC detectors. In order to efficiently reconstruct neutrino interactions and identify their flavour, the detector will combine in the target region nuclear emulsion technology with scintillating fibre tracking layers and it will adopt a muon identification system based on scintillating bars that will also play the role of a hadronic calorimeter. The time of flight measurement will be achieved thanks to a dedicated timing detector. The detector will be a small-scale prototype of the scattering and neutrino detector (SND) of the SHiP experiment: the operation of this detector will provide an important test of the neutrino reconstruction in a high occupancy environment.
△ Less
Submitted 20 February, 2020;
originally announced February 2020.
-
Multilayer $^{10}B$-RPC neutron imaging detector
Authors:
L. M. S. Margato,
A. Morozov,
A. Blanco,
P. Fonte,
L. Lopes,
K. Zeitelhack,
R. Hall-Wilton,
C. Höglund,
L. Robinson,
S. Schmidt,
P. Svensson
Abstract:
Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial resolution and timing. However, as for the other types of gaseous detectors with a single layer of $^{10}B_{4}$C at normal beam incidence, the detection efficiency to t…
▽ More
Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial resolution and timing. However, as for the other types of gaseous detectors with a single layer of $^{10}B_{4}$C at normal beam incidence, the detection efficiency to thermal neutrons of a single-gap $^{10}B$-RPC is only about 6%. Aiming to overcome this limitation, we introduce a multi-layer $^{10}B$-RPCs detector with a stack of ten double-gap hybrid RPCs. A description of the detector design and the results of its characterization performed at the TREFF neutron beamline at the FRM II neutron facility are presented. The results demonstrate that the detection efficiency exceeds 60% for neutrons with a wavelength of 4.7 Å and the spatial resolution (FWHM) is about 0.25 mm and 0.35 mm in the X and Y direction, respectively.
△ Less
Submitted 26 May, 2020; v1 submitted 3 February, 2020;
originally announced February 2020.
-
Boron-10 lined RPCs for sub-millimeter resolution thermal neutron detectors: Feasibility study in a thermal neutron beam
Authors:
L. M. S. Margato,
A. Morozov,
A. Blanco,
P. Fonte,
F. A. F. Fraga,
B. Guerard,
R. Hall-Wilton,
C. Höglund,
A. Mangiarotti,
L. Robinson,
S. Schmidt,
K. Zeitelhack
Abstract:
The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium cathode lined with a 2 $μ$m thick $^{10}B{_4}C$ neutron converter layer enriched in $^{10}B$ and a float glass anode. A detection efficiency of ${\approx}$ 6.2…
▽ More
The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium cathode lined with a 2 $μ$m thick $^{10}B{_4}C$ neutron converter layer enriched in $^{10}B$ and a float glass anode. A detection efficiency of ${\approx}$ 6.2 ${\%}$ was measured for the neutron beam ($λ$ =2.5 $Å$) at normal incidence. A spatial resolution better than 0.5 mm FWHM was demonstrated.
△ Less
Submitted 25 September, 2018;
originally announced September 2018.
-
MARTA: A high-energy cosmic-ray detector concept with high-accuracy muon measurement
Authors:
P. Abreu,
S. Andringa,
P. Assis,
A. Blanco,
V. Barbosa Martins,
P. Brogueira,
N. Carolino,
L. Cazon,
M. Cerda,
G. Cernicchiaro,
R. Colalillo,
R. Conceição,
O. Cunha,
R. M. de Almeida,
V. de Souza,
F. Diogo,
C. Dobrigkeit,
J. Espadanal,
C. Espirito-Santo,
M. Ferreira,
P. Ferreira,
P. Fonte,
U. Giaccari,
P. Gonçalves,
F. Guarino
, et al. (20 additional authors not shown)
Abstract:
A new concept for the direct measurement of muons in air showers is presented. The concept is based on resistive plate chambers (RPCs), which can directly measure muons with very good space and time resolution. The muon detector is shielded by placing it under another detector able to absorb and measure the electromagnetic component of the showers such as a water-Cherenkov detector, commonly used…
▽ More
A new concept for the direct measurement of muons in air showers is presented. The concept is based on resistive plate chambers (RPCs), which can directly measure muons with very good space and time resolution. The muon detector is shielded by placing it under another detector able to absorb and measure the electromagnetic component of the showers such as a water-Cherenkov detector, commonly used in air shower arrays. The combination of the two detectors in a single, compact detector unit provides a unique measurement that opens rich possibilities in the study of air showers.
△ Less
Submitted 20 April, 2018; v1 submitted 20 December, 2017;
originally announced December 2017.
-
LATTES: a novel detector concept for a gamma-ray experiment in the Southern hemisphere
Authors:
P. Assis,
U. Barres de Almeida,
A. Blanco,
R. Conceição,
B. D'Ettore Piazzoli,
A. De Angelis,
M. Doro,
P. Fonte,
L. Lopes,
G. Matthiae,
M. Pimenta,
R. Shellard,
B. Tomé
Abstract:
The Large Array Telescope for Tracking Energetic Sources (LATTES), is a novel concept for an array of hybrid EAS array detectors, composed of a Resistive Plate Counter array coupled to a Water Cherenkov Detector, planned to cover gamma rays from less than 100 GeV up to 100 TeVs. This experiment, to be installed at high altitude in South America, could cover the existing gap in sensitivity between…
▽ More
The Large Array Telescope for Tracking Energetic Sources (LATTES), is a novel concept for an array of hybrid EAS array detectors, composed of a Resistive Plate Counter array coupled to a Water Cherenkov Detector, planned to cover gamma rays from less than 100 GeV up to 100 TeVs. This experiment, to be installed at high altitude in South America, could cover the existing gap in sensitivity between satellite and ground arrays.
The low energy threshold, large duty cycle and wide field of view of LATTES makes it a powerful tool to detect transient phenomena and perform long term observations of variable sources. Moreover, given its characteristics, it would be fully complementary to the planned Cherenkov Telescope Array (CTA) as it would be able to issue alerts.
In this talk, a description of its main features and capabilities, as well as results on its expected performance, and sensitivity, will be presented.
△ Less
Submitted 30 April, 2018; v1 submitted 27 September, 2017;
originally announced September 2017.
-
Autonomous RPCs for a Cosmic Ray ground array
Authors:
Pedro Assis,
Alberto Blanco,
Nuno Carolino,
Ruben Conceição,
Orlando Cunha,
Carola Dobrigkeit,
Miguel Ferreira,
Paulo Fonte,
Luis Lopes,
Ricardo Luz,
Victor Barbosa Martins,
Luis Mendes,
Américo Pereira,
Mário Pimenta,
Raul Sarmento,
Ronald Shellard,
Vitor de Souza,
Bernardo Tomé
Abstract:
We report on the behaviour of Resistive Plate Chambers (RPC) developed for muon detection in ultra-high energy cosmic ray (UHECR) experiments. The RPCs were developed for the MARTA project and were tested on field conditions. These RPCs cover an area of $1.5 \times 1.2\,{m^2}$ and are instrumented with 64 pickup electrodes providing a segmentation better than $20\,$cm. By shielding the detector un…
▽ More
We report on the behaviour of Resistive Plate Chambers (RPC) developed for muon detection in ultra-high energy cosmic ray (UHECR) experiments. The RPCs were developed for the MARTA project and were tested on field conditions. These RPCs cover an area of $1.5 \times 1.2\,{m^2}$ and are instrumented with 64 pickup electrodes providing a segmentation better than $20\,$cm. By shielding the detector units with enough slant mass to absorb the electromagnetic component in the air showers, a clean measurement of the muon content is allowed, a concept to be implemented in a next generation of UHECR experiments. The operation of a ground array detector poses challenging demands, as the RPC must operate remotely under extreme environmental conditions, with limited budgets for power and minimal maintenance. The RPC, DAQ, High Voltage and monitoring systems are enclosed in an aluminium-sealed case, providing a compact and robust unit suited for outdoor environments, which can be easily deployed and connected. The RPCs developed at LIP-Coimbra are able to operate using a very low gas flux, which allows running them for few years with a small gas reservoir. Several prototypes have already been built and tested both in the laboratory and outdoors. We report on the most recent tests done in the field that show that the developed RPCs have operated in a stable way for more than 2 years in field conditions.
△ Less
Submitted 27 September, 2017;
originally announced September 2017.
-
Fast full-body reconstruction for a functional human RPC-PET imaging system using list-mode simulated data and its applicability to radiation oncology and radiology
Authors:
Paulo Magalhaes Martins,
Paulo Crespo,
Miguel Couceiro,
Nuno Chichorro Ferreira,
Rui Ferreira Marques,
Joao Seco,
Paulo Fonte
Abstract:
Single-bed whole-body positron emission tomography based on resistive plate chamber detectors (RPC-PET) has been proposed for human studies, as a complementary resource to scintillator-based PET scanners. The purpose of this work is mainly about providing a reconstruction solution to such whole-body single-bed data collection on an event-by-event basis. We demonstrate a fully three-dimensional tim…
▽ More
Single-bed whole-body positron emission tomography based on resistive plate chamber detectors (RPC-PET) has been proposed for human studies, as a complementary resource to scintillator-based PET scanners. The purpose of this work is mainly about providing a reconstruction solution to such whole-body single-bed data collection on an event-by-event basis. We demonstrate a fully three-dimensional time-of-flight (TOF)-based reconstruction algorithm that is capable of processing the highly inclined lines of response acquired from a system with a very large axial field of view, such as those used in RPC-PET. Such algorithm must be sufficiently fast that it will not compromise the clinical workflow of an RPC-PET system. We present simulation results from a voxelized version of the anthropomorphic NCAT phantom, with oncological lesions introduced into critical regions within the human body. The list-mode data was reconstructed with a TOF-weighted maximum-likelihood expectation maximization (MLEM). To accelerate the reconstruction time of the algorithm, a multi-threaded approach supported by graphical processing units (GPUs) was developed. Additionally, a TOF-assisted data division method is suggested that allows the data from nine body regions to be reconstructed independently and much more rapidly. The application of a TOF-based scatter rejection method reduces the overall body scatter from 57.1% to 32.9%. The results also show that a 300-ps FWHM RPC-PET scanner allows for the production of a reconstructed image in 3.5 minutes following a 7-minute acquisition upon the injection of 2 mCi of activity (146 M coincidence events). We present for the first time a full realistic reconstruction of a whole body, long axial coverage, RPC-PET scanner. We demonstrate clinically relevant reconstruction times comparable (or lower) to the patient acquisition times on both multi-threaded CPU and GPU.
△ Less
Submitted 21 June, 2017;
originally announced June 2017.
-
The active muon shield in the SHiP experiment
Authors:
SHiP collaboration,
A. Akmete,
A. Alexandrov,
A. Anokhina,
S. Aoki,
E. Atkin,
N. Azorskiy,
J. J. Back,
A. Bagulya,
A. Baranov,
G. J. Barker,
A. Bay,
V. Bayliss,
G. Bencivenni,
A. Y. Berdnikov,
Y. A. Berdnikov,
M. Bertani,
C. Betancourt,
I. Bezshyiko,
O. Bezshyyko,
D. Bick,
S. Bieschke,
A. Blanco,
J. Boehm,
M. Bogomilov
, et al. (207 additional authors not shown)
Abstract:
The SHiP experiment is designed to search for very weakly interacting particles beyond the Standard Model which are produced in a 400 GeV/c proton beam dump at the CERN SPS. An essential task for the experiment is to keep the Standard Model background level to less than 0.1 event after $2\times 10^{20}$ protons on target. In the beam dump, around $10^{11}$ muons will be produced per second. The mu…
▽ More
The SHiP experiment is designed to search for very weakly interacting particles beyond the Standard Model which are produced in a 400 GeV/c proton beam dump at the CERN SPS. An essential task for the experiment is to keep the Standard Model background level to less than 0.1 event after $2\times 10^{20}$ protons on target. In the beam dump, around $10^{11}$ muons will be produced per second. The muon rate in the spectrometer has to be reduced by at least four orders of magnitude to avoid muon-induced combinatorial background. A novel active muon shield is used to magnetically deflect the muons out of the acceptance of the spectrometer. This paper describes the basic principle of such a shield, its optimization and its performance.
△ Less
Submitted 18 May, 2017; v1 submitted 10 March, 2017;
originally announced March 2017.
-
TRAGALDABAS. First results on cosmic ray studies and their relation with the solar activity, the Earth magnetic field and the atmospheric properties
Authors:
J. A. Garzón,
J. Collazo,
J. Cuenca-García,
D. Garcí a Castro,
J. Otero,
M. Yermo,
J. J. Blanco,
T. Kurtukian,
A. Morozova,
M. A. Pais,
A. Blanco,
P. Fonte,
L. Lopes,
G. Kornakov,
H. Álvarez-Pol,
P. Cabanelas,
A. Pazos,
M. Seco,
I. Riádigos,
V. Pérez Muñuzuri,
A. Gómez-Tato,
J. C. Mouriño,
P. Rey,
J. Taboada
Abstract:
Cosmic rays originating from extraterrestrial sources are permanently arriving at Earth atmosphere, where they produce up to billions of secondary particles. The analysis of the secondary particles reaching to the surface of the Earth may provide a very valuable information about the Sun activity, changes in the geomagnetic field and the atmosphere, among others. In this article, we present the fi…
▽ More
Cosmic rays originating from extraterrestrial sources are permanently arriving at Earth atmosphere, where they produce up to billions of secondary particles. The analysis of the secondary particles reaching to the surface of the Earth may provide a very valuable information about the Sun activity, changes in the geomagnetic field and the atmosphere, among others. In this article, we present the first preliminary results of the analysis of the cosmic rays measured with a high resolution tracking detector, TRAGALDABAS, located at the Univ. of Santiago de Compostela, in Spain.
△ Less
Submitted 25 January, 2017;
originally announced January 2017.
-
Outdoor Field Experience with Autonomous RPC Based Stations
Authors:
L. Lopes,
P. Assis,
A. Blanco,
N. Carolino,
M. A. Cerda,
R. Conceição,
O. Cunha,
M. Ferreira,
P. Fonte,
R. Luz,
L. Mendes,
A. Pereira,
M. Pimenta,
R. Sarmento,
B. Tomé
Abstract:
In the last two decades Resistive Plate Chambers were employed in the Cosmic Ray Experiments COVER-PLASTEX and ARGO/YBJ. In both experiments the detectors were housed indoors, likely owing to gas distribution requirements and the need to control environment variables that directly affect RPCs operational stability. But in experiments where Extended Air Shower (EAS) sampling is necessary, large are…
▽ More
In the last two decades Resistive Plate Chambers were employed in the Cosmic Ray Experiments COVER-PLASTEX and ARGO/YBJ. In both experiments the detectors were housed indoors, likely owing to gas distribution requirements and the need to control environment variables that directly affect RPCs operational stability. But in experiments where Extended Air Shower (EAS) sampling is necessary, large area arrays composed by dispersed stations are deployed, rendering this kind of approach impossible. In this situation, it would be mandatory to have detectors that could be deployed in small standalone stations, with very rare opportunities for maintenance, and with good resilience to environmental conditions. Aiming to meet these requirements, we started some years ago the development of RPCs for Autonomous Stations. The results from indoor tests and measurements were very promising, both concerning performance and stability under very low gas flow rate, which is the main requirement for Autonomous Stations. In this work we update the indoor results and show the first ones concerning outdoor stable operation. In particular, a dynamic adjustment of the high voltage is applied to keep gas gain constant.
△ Less
Submitted 30 August, 2016; v1 submitted 10 June, 2016;
originally announced June 2016.
-
Demonstration of new possibilities of multilayer technology on resistive microstrip/ microdot detectors
Authors:
V. Cairo,
R. De Oliveira,
P. Fonte,
S. Franchino,
V. Peskov,
P. Picchi,
F. Pietropaolo
Abstract:
The first successful attempts to optimize the electric field in Resistive Microstrip Gas Chamber and resistive microdot detectors using additional field shaping strips located inside the detector substrate are described
The first successful attempts to optimize the electric field in Resistive Microstrip Gas Chamber and resistive microdot detectors using additional field shaping strips located inside the detector substrate are described
△ Less
Submitted 26 June, 2014;
originally announced June 2014.
-
Development of a new generation of micropattern gaseous detectors for high energy physics, astrophysics and environmental applications
Authors:
V. Peskov,
A. Di Mauroa,
P. Fonte,
P. Martinengo,
E. Nappi,
R. Oliveira,
P. Pietropaolo,
P. Picchi
Abstract:
We have developed a cost effective technology for manufacturing various layouts of micropattern gaseous detectors for a wide range of applications. Such devices feature resistive electrodes interfaced to a network of thin readout strips/electrodes. The following three examples of such innovative designs and their applications will be presented: a prototype of a novel double-phase LAr detector with…
▽ More
We have developed a cost effective technology for manufacturing various layouts of micropattern gaseous detectors for a wide range of applications. Such devices feature resistive electrodes interfaced to a network of thin readout strips/electrodes. The following three examples of such innovative designs and their applications will be presented: a prototype of a novel double-phase LAr detector with a CsI photocathode immersed inside the LAr, a CsI-RICH detector prototype for ALICE upgrade and GEM-like sensors for environmental safety/security applications.
△ Less
Submitted 3 May, 2013;
originally announced May 2013.
-
Frequency-domain formulation of signal propagation in multistrip Resistive Plate Chambers and its low-loss, weak-coupling analytical approximation
Authors:
P. Fonte
Abstract:
In this study the signal propagation in multistrip Resistive Plate Chambers is formulated exactly in the framework of the multiconductor transmission line theory in the frequency domain, allowing losses to be incorporated. For the case of weak coupling and low losses a first-order expansion yields simple, fully analytical, expressions that include reflections. In this approximation the modal spect…
▽ More
In this study the signal propagation in multistrip Resistive Plate Chambers is formulated exactly in the framework of the multiconductor transmission line theory in the frequency domain, allowing losses to be incorporated. For the case of weak coupling and low losses a first-order expansion yields simple, fully analytical, expressions that include reflections. In this approximation the modal spectrum can be calculated analytically as well, allowing to estimate easily the strength of the modal dispersion phenomenon.
△ Less
Submitted 9 January, 2013;
originally announced January 2013.
-
Analytical calculation of the charge spectrum generated by ionizing particles in Resistive Plate Chambers at low gas gain
Authors:
P. Fonte
Abstract:
In this article it is shown analytically that the charge spectrum generated by ionizing particles in Resistive Plate Chambers under Townsend avalanche conditions, that is, for sufficiently small avalanches not affected by space-charge and considering single-electron ionization clusters follows closely the statistical gamma distribution. This distribution describes well comparable simulation data t…
▽ More
In this article it is shown analytically that the charge spectrum generated by ionizing particles in Resistive Plate Chambers under Townsend avalanche conditions, that is, for sufficiently small avalanches not affected by space-charge and considering single-electron ionization clusters follows closely the statistical gamma distribution. This distribution describes well comparable simulation data taken from the literature, but seems to describe as well experimental data measured beyond these assumptions, rising some interpretation issues.
△ Less
Submitted 5 March, 2013; v1 submitted 7 November, 2012;
originally announced November 2012.
-
Development and preliminary tests of resistive microdot and microstrip detectors
Authors:
P. Fonte,
E. Nappi,
P. Martinengo,
R. Oliveira,
V. Peskov F. Pietropaolo,
P. Picchi
Abstract:
In the last few years our group have focused on developing various designs of spark-protected micropattern gaseous detectors featuring resistive electrodes instead of the traditional metallic ones: resistive microstrip counters, resistive GEM, resistive MICROMEGAS. These detectors combine in one design the best features of RPCs (spark-protection) and micropattern detectors (a high position resolut…
▽ More
In the last few years our group have focused on developing various designs of spark-protected micropattern gaseous detectors featuring resistive electrodes instead of the traditional metallic ones: resistive microstrip counters, resistive GEM, resistive MICROMEGAS. These detectors combine in one design the best features of RPCs (spark-protection) and micropattern detectors (a high position resolution). In this paper we report the progress so far made in developing other types of resistive micropattern detectors: a microdot-microhole detector and a microgap-microstrip detector. The former detector is an optimal electron amplifier for some special designs of dual phase noble liquid TPCs, for example with a CsI photocathode immersed inside the noble liquid. Preliminary tests of such a detector, for the first time built and investigated, are reported in this paper. The latter detector is mainly orientated towards medical imaging applications such as X-ray scanners. However, we believe that after a proper gas optimization, these detectors could also achieve a high time resolution and could thus be used in applications as TOF-PET, detection of charged particles with simultaneous high time and position resolution etc.
△ Less
Submitted 23 August, 2012; v1 submitted 16 March, 2012;
originally announced March 2012.
-
Advances in the Development of Micropattern Gaseous Detectors with Resistive Electrodes
Authors:
P. Fonte,
P. Martinengo,
E. Nappi,
R. Oliveira,
V. Peskov,
F. Pietropaolo,
P. Picchi
Abstract:
We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and spark protection property) with the high granularity and thus the good position resolution offered by microelectronic technology. In the stream of this activit…
▽ More
We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and spark protection property) with the high granularity and thus the good position resolution offered by microelectronic technology. In the stream of this activity, we have recently developed two novel detectors with resistive electrodes: one was based on resistive micromeshes and the second one is a MSGC with resistive electrodes. We have demonstrated that the resistive meshes are a convenient construction element for various designs of spark protective detectors: RPCs type, GEM type and MICROMEGAS type. These new detectors enable to considerably enhance the RPC and micropattern detectors applications since they feature not only a high position resolution but also a relatively good energy resolution (25-30 persent FWHM at 6 keV) and, if necessary, they can operate in cascaded mode allowing the achievement of a high overall gas gain. The main conclusion from these studies is that the implementation of resistive electrodes in micropattern detectors makes them fully spark protected; on this basis we consider this direction very promising.
△ Less
Submitted 10 May, 2010;
originally announced May 2010.
-
Research on discharges in micropattern and small gap gaseous detectors
Authors:
V. Peskov,
P. Fonte
Abstract:
This report summarizes the present knowledge on discharges in micropattern and small gap gaseous detectors and the physical mechanisms involved. These include the space-charge (Raether's) limit, rate-induced breakdown, cathode excitation effect and electron emission from the cathodes in the form of jets, inter-GEM breakdown in multistep configurations and finally surface streamers.
This report summarizes the present knowledge on discharges in micropattern and small gap gaseous detectors and the physical mechanisms involved. These include the space-charge (Raether's) limit, rate-induced breakdown, cathode excitation effect and electron emission from the cathodes in the form of jets, inter-GEM breakdown in multistep configurations and finally surface streamers.
△ Less
Submitted 2 November, 2009;
originally announced November 2009.
-
On the physics and technology of gaseous particle detectors
Authors:
P. Fonte,
V. Peskov
Abstract:
Despite an already long and fruitful history, gaseous elementary-particle detectors remain today an important mainstay of high-energy and nuclear physics experiments and of radiation detection in general. In here we briefly describe some of the gaseous detector's main technologies and applications, along with some unsolved gas-discharge physics aspects of practical relevance.
Despite an already long and fruitful history, gaseous elementary-particle detectors remain today an important mainstay of high-energy and nuclear physics experiments and of radiation detection in general. In here we briefly describe some of the gaseous detector's main technologies and applications, along with some unsolved gas-discharge physics aspects of practical relevance.
△ Less
Submitted 15 March, 2010; v1 submitted 14 September, 2009;
originally announced September 2009.
-
Progress in Developing Hybrid RPCs: GEM-like Detectors with Resistive Electrodes
Authors:
P. Fonte,
P. Martinengo,
E. Nappi,
R. Oliveira,
V. Peskov
Abstract:
We have recently developed an innovative detector of photons and charged particles: a GEM-like gaseous amplification structure with resistive electrodes instead of commonly used metallic ones. This novel detector combines the best property of GEMs- the capability to operate in a cascaded mode and in poorly quenched gases - and of RPC: the protection against sparks. In this paper will shortly rev…
▽ More
We have recently developed an innovative detector of photons and charged particles: a GEM-like gaseous amplification structure with resistive electrodes instead of commonly used metallic ones. This novel detector combines the best property of GEMs- the capability to operate in a cascaded mode and in poorly quenched gases - and of RPC: the protection against sparks. In this paper will shortly review our latest achievements in this direction, however the main focus will be given on a new advanced design that allows to build large area detectors manufactured by a screen printing technology. The proposed detector, depending on the applications, can operate either in a GEM mode (electron multiplications through holes only) or as a hybrid RPC with simultaneous amplifications in the drift region and in the holes. The possible applications of this new detector will be discussed.
△ Less
Submitted 18 May, 2008;
originally announced May 2008.
-
The first applications of novel gaseous detectors for UV visualization
Authors:
J-M. Bidault,
I. Crotty,
A. Di Mauro,
P. Martinengo,
P. Fonte,
F. Galy,
V. Peskov,
I. Rodionov,
O. Zanette
Abstract:
We have demonstrated experimentally that recently developed gaseous detectors combined with solid or gaseous photo-cathodes have exceptionally low noise and high quantum efficiency for UV photons while being solar blind. For this reason they can be used for the detection of weak UV sources in daylight conditions. These detectors are extremely robust, can operate in poor gas conditions and are ch…
▽ More
We have demonstrated experimentally that recently developed gaseous detectors combined with solid or gaseous photo-cathodes have exceptionally low noise and high quantum efficiency for UV photons while being solar blind. For this reason they can be used for the detection of weak UV sources in daylight conditions. These detectors are extremely robust, can operate in poor gas conditions and are cheap. We present the first results of their applications to hyper-spectroscopy and flame detection in daylight conditions.
△ Less
Submitted 1 December, 2006;
originally announced December 2006.
-
A Novel UV Photon Detector with Resistive Electrodes
Authors:
J. M. Bidault,
P. Fonte,
T. Francke,
P. Galy,
V. Peskov,
I. Rodionov
Abstract:
In this study we present first results from a new detector of UV photons: a thick gaseous electron multiplier (GEM) with resistive electrodes, combined with CsI or CsTe/CsI photocathodes. The hole type structure considerably suppresses the photon and ion feedback, whereas the resistive electrodes protect the detector and the readout electronics from damage by any eventual discharges. This device…
▽ More
In this study we present first results from a new detector of UV photons: a thick gaseous electron multiplier (GEM) with resistive electrodes, combined with CsI or CsTe/CsI photocathodes. The hole type structure considerably suppresses the photon and ion feedback, whereas the resistive electrodes protect the detector and the readout electronics from damage by any eventual discharges. This device reaches higher gains than a previously developed photosensitive RPC and could be used not only for the imaging of UV sources, flames or Cherenkov light, for example, but also for the detection of X-rays and charged particles.
△ Less
Submitted 16 February, 2006;
originally announced February 2006.
-
Advanced Photodetectors for Hyperspectroscopy and Other Applications
Authors:
I. Rodionov,
J-M. Bidault,
I. Crotty,
P. Fonte,
F. Galy,
V. Peskov,
O. Zanette
Abstract:
Hyperspectroscopy is a new method of surface image taking, providing simultaneously high position and spectral resolutions which allow one to make some conclusions about chemical compositions of the surfaces. We are now studying applications of the hyperspctroscopic technique to be used for medicine. This may allow one to develop early diagnostics of some illnesses, as for example, skin cancer.…
▽ More
Hyperspectroscopy is a new method of surface image taking, providing simultaneously high position and spectral resolutions which allow one to make some conclusions about chemical compositions of the surfaces. We are now studying applications of the hyperspctroscopic technique to be used for medicine. This may allow one to develop early diagnostics of some illnesses, as for example, skin cancer. For image taking advanced MCPs are currently used, sensitive in the spectral interval of 450-850 nm. One of the aims of this work is to extend the hyperspectrocpic method to the UV region of spectra: 185-280 nm. For this we have developed and successfully tested innovative 1D and 2D UV sealed photosensitive gaseous detectors with resistive electrodes. These detectors are superior MCPs due to the very low rate of noise pulses and thus due to the high signal to noise ratio. Other important features of these detectors are that they have excellent position resolutions - 30 micron in digital form, are vibration stable and are spark protected. The first results from the application of these detectors for spectroscopy, hyperspectroscopy and the flame detection are presented.
△ Less
Submitted 25 November, 2005;
originally announced November 2005.
-
Novel Single Photon Detectors for UV Imaging
Authors:
P. Fonte,
T. Francke,
N. Pavlopoulos,
V. Peskov,
I. Rodionov
Abstract:
There are several applications which require high position resolution UV imaging. For these applications we have developed and successfully tested a new version of a 2D UV single photon imaging detector based on a microgap RPC. The main features of such a detectors is the high position resolution - 30 micron in digital form and the high quantum efficiency (1-8% in the spectral interval of 220-14…
▽ More
There are several applications which require high position resolution UV imaging. For these applications we have developed and successfully tested a new version of a 2D UV single photon imaging detector based on a microgap RPC. The main features of such a detectors is the high position resolution - 30 micron in digital form and the high quantum efficiency (1-8% in the spectral interval of 220-140 nm). Additionally, they are spark- protected and can operate without any feedback problems at high gains, close to a streamer mode. In attempts to extend the sensitivity of RPCs to longer wavelengths we have successfully tested the operation of the first sealed parallel-plate gaseous detectors with CsTe photocathodes. Finally, the comparison with other types of photosensitive detectors is given and possible fields of applications are identified.
△ Less
Submitted 7 February, 2005;
originally announced February 2005.
-
Resistive plate chambers for time-of-flight measurements
Authors:
A. Blanco,
P. Fonte,
L. Lopes,
A. Mangiarotti,
R. Ferreira-Marques,
A. Policarpo
Abstract:
The applications of Resistive Plate Chambers (RPCs) have recently been extended by the development of counters with time resolution below 100 ps sigma for minimum ionising particles. Applications to HEP experiments have already taken place and many further applications are under study. In this work we address the operating principles of such counters along with some present challenges, with emph…
▽ More
The applications of Resistive Plate Chambers (RPCs) have recently been extended by the development of counters with time resolution below 100 ps sigma for minimum ionising particles. Applications to HEP experiments have already taken place and many further applications are under study. In this work we address the operating principles of such counters along with some present challenges, with emphasis on counter aging.
△ Less
Submitted 29 November, 2002;
originally announced November 2002.
-
The Development and Study of High-Position Resolution (50 micron) RPCs for Imaging X-rays and UV photons
Authors:
C. Iacobaeus,
P. Fonte,
T. Francke,
J. Ostling,
V. Peskov,
J. Rantanen,
I. Rodionov
Abstract:
Nowadays, commonly used Resistive Plate Chambers (RPCs) have counting rate capabilities of ~10E4Hz/cm2 and position resolutions of ~1cm. We have developed small prototypes of RPCs (5x5 and 10x10cm2) having rate capabilities of up to 10E7Hz/cm2 and position resolutions of 50 micron("on line" without application of any treatment method like "center of gravity"). The breakthrough in achieving extra…
▽ More
Nowadays, commonly used Resistive Plate Chambers (RPCs) have counting rate capabilities of ~10E4Hz/cm2 and position resolutions of ~1cm. We have developed small prototypes of RPCs (5x5 and 10x10cm2) having rate capabilities of up to 10E7Hz/cm2 and position resolutions of 50 micron("on line" without application of any treatment method like "center of gravity"). The breakthrough in achieving extraordinary rate and position resolutions was only possible after solving several serious problems: RPC cleaning and assembling technology, aging, spurious pulses and afterpulses, discharges in the amplification gap and along the spacers. High-rate, high-position resolution RPCs can find a wide range of applications in many different fields, for example in medical imaging. RPCs with the cathodes coated by CsI photosensitive layer can detect ultraviolet photons with a position resolution that is better than ~30 micron. Such detectors can also be used in many applications, for example in the focal plane of high resolution vacuum spectrographs or as image scanners.
△ Less
Submitted 2 October, 2002;
originally announced October 2002.
-
Perspectives for Positron Emission Tomography with RPCs
Authors:
A. Blanco,
V. Chepel,
R. Ferreira-Marques,
P. Fonte,
M. I. Lopes,
V. Peskov,
A. Policarpo
Abstract:
In this study we address the feasibility and main properties of a positron emission tomograph (PET) based on RPCs. The concept, making use of the converter-plate principle, takes advantage of the intrinsic layered structure of RPCs and its simple and economic construction. The extremely good time and position resolutions of RPCs also allow the TOF-PET imaging technique to be considered. Monte-Ca…
▽ More
In this study we address the feasibility and main properties of a positron emission tomograph (PET) based on RPCs. The concept, making use of the converter-plate principle, takes advantage of the intrinsic layered structure of RPCs and its simple and economic construction. The extremely good time and position resolutions of RPCs also allow the TOF-PET imaging technique to be considered. Monte-Carlo simulations, supported by experimental data, are presented and the main advantages and drawbacks for applications of potential interest are discussed.
△ Less
Submitted 19 September, 2002;
originally announced September 2002.
-
Potential of RPCs for tracking
Authors:
T. Francke,
P. Fonte,
V. Peskov,
J. Rantanen
Abstract:
We have demonstrated that small gap (0.1 to 0.4 mm) RPCs made of low resistivity materials (less than 1E8 Ohm.cm) can operate at counting rates of up to 1E5 Hz/mm2 with position resolutions better than 50 micrometer. Results of preliminary tests allow us to suggest a possible application of this new type of RPC for tracking.
We have demonstrated that small gap (0.1 to 0.4 mm) RPCs made of low resistivity materials (less than 1E8 Ohm.cm) can operate at counting rates of up to 1E5 Hz/mm2 with position resolutions better than 50 micrometer. Results of preliminary tests allow us to suggest a possible application of this new type of RPC for tracking.
△ Less
Submitted 13 June, 2002;
originally announced June 2002.
-
Sporadic electron jets from cathodes - The main breakdown-triggering mechanism in gaseous detectors
Authors:
C. Iacobaeus,
M. Danielsson,
P. Fonte,
T. Francke,
J. Ostling,
V. Peskov
Abstract:
We have demonstrated experimentally that the main breakdown-triggering mechanism in most gaseous detectors, including micropattern gaseous detectors, is sporadic electron jets from the cathode surfaces.
Depending on conditions, each jet contains randomly from a few primary electrons up to 10^5, emitted in a time interval ranging between 0.1 microsecond to milliseconds. After the emission, thes…
▽ More
We have demonstrated experimentally that the main breakdown-triggering mechanism in most gaseous detectors, including micropattern gaseous detectors, is sporadic electron jets from the cathode surfaces.
Depending on conditions, each jet contains randomly from a few primary electrons up to 10^5, emitted in a time interval ranging between 0.1 microsecond to milliseconds. After the emission, these primary electrons experience a full gas multiplication in the detector and create spurious pulses.
The rate of these jets increases with applied voltage and very sharply at voltages close to the breakdown limit. We found that these jets are in our measurements responsible for the breakdown-triggering at any counting rate between 10^(-2) Hz/mm^2 and 10^8 Hz/mm^2. We demonstrated on a few detectors that an optimized cathode-geometry, a high electrode surface quality and a proper choice of the gas mixture, considerably improve the performance characteristics and provide the highest possible gains.
△ Less
Submitted 5 December, 2001;
originally announced December 2001.
-
Gain, Rate and Position Resolution Limits of Micropattern Gaseous Detectors
Authors:
V. Peskov,
P. Fonte
Abstract:
In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which depends on the size and design features, as well as on gas composition and pressure. However, in all cases the maximum achievable gain is less than or equal…
▽ More
In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which depends on the size and design features, as well as on gas composition and pressure. However, in all cases the maximum achievable gain is less than or equal to the classical Raether limit. It also was found that for all detectors tested the maximum achievable gain drops sharply with the counting rate. The position resolution of micropattern detectors for detection of X-rays (6 to 35 kV) was also studied, being demonstrated that with solid converters one could reach a position resolution better than 30 micrometers at 1 atm in a simple counting mode.
△ Less
Submitted 5 June, 2001;
originally announced June 2001.
-
Fundamentals of Gas Micropattern Detectors
Authors:
V. Peskov,
P. Fonte,
M. Danielsson,
C. Iacobaeus,
J. Ostling,
M. Wallmark
Abstract:
We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done at various pressures, gas mixtures, at a wide range of primary charges and also when the whole area of the detectors was irradiated with a high intensity x-ray beam. Several new effects were discovered, common to all t…
▽ More
We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done at various pressures, gas mixtures, at a wide range of primary charges and also when the whole area of the detectors was irradiated with a high intensity x-ray beam. Several new effects were discovered, common to all tested detectors, which define fundamental limits of operation. The results of these studies allow us to identify several concrete ways of improving the performance of micropattern detectors and to suggest that in some applications RPCs may constitute a valid alternative. Being protected from damaging discharges by the resistive electrodes, these detectors feature high gain, high rate capability (10^5 Hz/mm^2), good position resolution (better than 30 micrometer) and excellent timing (50 ps sigma).
△ Less
Submitted 5 June, 2001;
originally announced June 2001.
-
A Large Area Timing RPC
Authors:
A. Blanco,
R. Ferreira-Marques,
Ch. Finck,
P. Fonte,
A. Gobbi,
A. Policarpo,
M. Rozas
Abstract:
A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics.
A timing resolution between 50 and 75 ps sigma with an efficiency for Minimum Ionizing Particles (MIPs) larger than 95% was attained over the whole active area,…
▽ More
A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics.
A timing resolution between 50 and 75 ps sigma with an efficiency for Minimum Ionizing Particles (MIPs) larger than 95% was attained over the whole active area, in addition with a position resolution along the strips of 1.2 cm.
Despite the large active area per electronic channel, the observed timing resolution is remarkably close to the one previously obtained (50 ps sigma) with much smaller chambers of about 10 cm2 area. These results open perspectives of extending the application of timing RPCs to large area arrays exposed to moderate particle multiplicities, where the low cost, good time resolution, insensitivity to the magnetic field and compact mechanics may be attractive when compared with the standard scintillator-based Time-of-Flight (TOF) technology.
△ Less
Submitted 26 March, 2001;
originally announced March 2001.
-
High-resolution TOF with RPCs
Authors:
P. Fonte,
V. Peskov
Abstract:
In this work we describe some recent results concerning the application of Resistive Plate Chambers operated in avalanche mode at atmospheric pressure for high-resolution time-of-flight measurements. A combination of multiple, mechanically accurate, thin gas gaps and state-of-the-art electronics yielded an overall (detector plus electronics) timing accuracy better than 50 ps sigma with a detecti…
▽ More
In this work we describe some recent results concerning the application of Resistive Plate Chambers operated in avalanche mode at atmospheric pressure for high-resolution time-of-flight measurements. A combination of multiple, mechanically accurate, thin gas gaps and state-of-the-art electronics yielded an overall (detector plus electronics) timing accuracy better than 50 ps sigma with a detection efficiency up to 99% for MIPs. Single gap chambers were also tested in order to clarify experimentally several aspects of the mode of operation of these detectors. These results open perspectives of affordable and reliable high granularity large area TOF detectors, with an efficiency and time resolution comparable to the existing scintillator-based TOF technology but with a significantly, up to an order of magnitude, lower price per channel.
△ Less
Submitted 19 March, 2001;
originally announced March 2001.
-
High Resolution RPC's for Large TOF Systems
Authors:
P. Fonte,
R. Ferreira Marques,
J. Pinhao,
N. Carolino,
A. Policarpo
Abstract:
Here we report on a particular type of RPC that presents up to 99% efficiency for minimum ionizing particles and a very sharp time resolution, below 50 ps sigma in the most optimized conditions. Our 9 cm2 cells, made with glass and metal electrodes that form accurately spaced gaps of a few hundred micrometers, are operated at atmospheric pressure in non-flammable gases and can be economically pr…
▽ More
Here we report on a particular type of RPC that presents up to 99% efficiency for minimum ionizing particles and a very sharp time resolution, below 50 ps sigma in the most optimized conditions. Our 9 cm2 cells, made with glass and metal electrodes that form accurately spaced gaps of a few hundred micrometers, are operated at atmospheric pressure in non-flammable gases and can be economically produced in large quantities, opening perspectives for the construction of large area time of flight systems.
△ Less
Submitted 16 August, 1999; v1 submitted 11 July, 1999;
originally announced July 1999.
-
Thin gap parallel mesh chamber: a sparkless high-rate detector
Authors:
P. Fonte,
R. Ferreira-Marques,
Y. Ivaniouchenkov,
V. Peskov,
A. Policarpo
Abstract:
In this work we describe a parallel geometry gaseous detector constituted by a thin (0.6 mm) amplifying gap preceded by a drift region. The gap is delimited by a metal plate and by a wire mesh. The detector can count up to a rate of 10^7 Hz/mm2 at gain 1000 and retains at lower counting rates the high gains (close to 10^6) that are typical of parallel geometry detectors. Additionally it was foun…
▽ More
In this work we describe a parallel geometry gaseous detector constituted by a thin (0.6 mm) amplifying gap preceded by a drift region. The gap is delimited by a metal plate and by a wire mesh. The detector can count up to a rate of 10^7 Hz/mm2 at gain 1000 and retains at lower counting rates the high gains (close to 10^6) that are typical of parallel geometry detectors. Additionally it was found that in the thin amplifying gap the discharges seem to be self-quenched and that full sparks do not develop. This fact, together with the robustness of the electrode materials, makes this an extremely resilient high-rate detector.
△ Less
Submitted 15 March, 1998;
originally announced March 1998.