-
Uncertainties of a Spherical Magnetic Field Camera
Authors:
Fynn Foerger,
Philip Suskin,
Marija Boberg,
Jonas Faltinath,
Tobias Knopp,
Martin Möddel
Abstract:
Spherical harmonic expansions are well-established tools for estimating magnetic fields from surface measurements and are widely used in applications such as tomographic imaging, geomagnetism, and biomagnetism. Although the mathematical foundations of these expansions are well understood, the impact of real-world imperfections, on the uncertainty of the field model has received little attention. I…
▽ More
Spherical harmonic expansions are well-established tools for estimating magnetic fields from surface measurements and are widely used in applications such as tomographic imaging, geomagnetism, and biomagnetism. Although the mathematical foundations of these expansions are well understood, the impact of real-world imperfections, on the uncertainty of the field model has received little attention. In this work, we present a systematic uncertainty propagation analysis for a magnetic field camera that estimates the field from surface measurements using a spherical array of Hall magnetometers arranged in a spherical t-design. A Monte Carlo-based approach is employed to quantify how sensor-related uncertainties, such as calibration errors and positioning inaccuracies, affect the spatial distribution of the estimated field's uncertainty. The results offer insights into the robustness of spherical harmonic methods and help identify the dominant sources of uncertainty in practical implementations.
△ Less
Submitted 20 June, 2025;
originally announced June 2025.
-
Natural Frequency Dependency of Magneto-Mechanical Resonators on Magnet Distance
Authors:
Jonas Faltinath,
Fabian Mohn,
Fynn Foerger,
Martin Möddel,
Tobias Knopp
Abstract:
The precise derivation of physical quantities like temperature or pressure at arbitrary locations is useful in numerous contexts, e.g. medical procedures or industrial process engineering. The novel sensor technology of magneto-mechanical resonators (MMR), based on the interaction of a rotor and stator permanent magnet, allows for the combined tracking of the sensor position and orientation while…
▽ More
The precise derivation of physical quantities like temperature or pressure at arbitrary locations is useful in numerous contexts, e.g. medical procedures or industrial process engineering. The novel sensor technology of magneto-mechanical resonators (MMR), based on the interaction of a rotor and stator permanent magnet, allows for the combined tracking of the sensor position and orientation while simultaneously sensing an external measurand. Thereby, the quantity is coupled to the torsional oscillation frequency, e.g. by varying the magnet distance. In this paper, we analyze the (deflection angle-independent) natural frequency dependency of MMR sensors on the rotor-stator distance, and evaluate the performance of theoretical models. The presented sensors incorporate magnets of spherical and/or cylindrical geometry. We find the distance-frequency relationship to be well described by an adapted dipole model accounting for material and manufacturing uncertainties. Their combined effect can be compensated by an adjustment of a single parameter which drives the median model deviation generally below 0.2 %. Our depicted methods and results are important for the design and calibration process of new sensor types utilizing the MMR technique
△ Less
Submitted 6 March, 2025;
originally announced March 2025.
-
Real-Time 3D Magnetic Field Camera for a Spherical Volume
Authors:
Fynn Foerger,
Marija Boberg,
Niklas Hackelberg,
Philip Heinisch,
Katharina Ostaszewski,
Jonas Faltinath,
Florian Thieben,
Fabian Mohn,
Paul Jürß,
Martin Möddel,
Tobias Knopp
Abstract:
Accurate and efficient volumetric magnetic field measurements are essential for a wide range of applications. Conventional methods are often limited in terms of measurement speed and applicability, or suffer from scaling problems at larger volumes. This work presents the development of a magnetometer array designed to measure magnetic fields within a spherical volume at a frame rate of 10 Hz. The…
▽ More
Accurate and efficient volumetric magnetic field measurements are essential for a wide range of applications. Conventional methods are often limited in terms of measurement speed and applicability, or suffer from scaling problems at larger volumes. This work presents the development of a magnetometer array designed to measure magnetic fields within a spherical volume at a frame rate of 10 Hz. The array consists of 3D Hall magnetometers positioned according to a spherical $t$-design, allowing simultaneous magnetic field data acquisition from the surface of the sphere. The approach enables the efficient representation of all three components of the magnetic field inside the sphere using a sixth-degree polynomial, significantly reducing measurement time compared to sequential methods. This work details the design, calibration, and measurement methods of the array. To evaluate its performance, we compare it to a sequential single-sensor measurement by examining a magnetic gradient field. The obtained measurement uncertainties of approx. 1% show the applicability for a variety of applications.
△ Less
Submitted 6 March, 2025;
originally announced March 2025.
-
Resonant Inductive Coupling Network for Human-Sized Magnetic Particle Imaging
Authors:
Fabian Mohn,
Fynn Förger,
Florian Thieben,
Martin Möddel,
Ingo Schmale,
Tobias Knopp,
Matthias Graeser
Abstract:
In Magnetic Particle Imaging, a field-free region is maneuvered throughout the field of view using a time-varying magnetic field known as the drive-field. Human-sized systems operate the drive-field in the kHz range and generate it by utilizing strong currents that can rise to the kA range within a coil called the drive field generator. Matching and tuning between a power amplifier, a band-pass fi…
▽ More
In Magnetic Particle Imaging, a field-free region is maneuvered throughout the field of view using a time-varying magnetic field known as the drive-field. Human-sized systems operate the drive-field in the kHz range and generate it by utilizing strong currents that can rise to the kA range within a coil called the drive field generator. Matching and tuning between a power amplifier, a band-pass filter and the drive-field generator is required. Here, for reasons of safety in future human scanners, a symmetrical topology and a transformer, called inductive coupling network is used. Our primary objectives are to achieve floating potentials to ensure patient safety, attaining high linearity and high gain for the resonant transformer. We present a novel systematic approach to the design of a loss-optimized resonant toroid with a D-shaped cross section, employing segmentation to adjust the inductance-to-resistance ratio while maintaining a constant quality factor. Simultaneously, we derive a specific matching condition of a symmetric transmit-receive circuit for magnetic particle imaging. The chosen setup filters the fundamental frequency and allows simultaneous signal transmission and reception. In addition, the decoupling of multiple drive field channels is discussed and the primary side of the transformer is evaluated for maximum coupling and minimum stray field. Two prototypes were constructed, measured, decoupled, and compared to the derived theory and to method-of-moment based simulations.
△ Less
Submitted 18 March, 2024; v1 submitted 23 December, 2023;
originally announced December 2023.
-
System Characterization of a Human-Sized 3D Real-Time Magnetic Particle Imaging Scanner for Cerebral Applications
Authors:
Florian Thieben,
Fynn Foerger,
Fabian Mohn,
Niklas Hackelberg,
Marija Boberg,
Jan-Philipp Scheel,
Martin Möddel,
Matthias Graeser,
Tobias Knopp
Abstract:
Since the initial patent in 2001, the Magnetic Particle Imaging (MPI) community has been striving to develop an MPI scanner suitable for human applications. Numerous contributions from different research fields, regarding tracer development, reconstruction methods, hardware engineering, and sequence design have been employed in pursuit of this objective. In this work, we introduce and thoroughly c…
▽ More
Since the initial patent in 2001, the Magnetic Particle Imaging (MPI) community has been striving to develop an MPI scanner suitable for human applications. Numerous contributions from different research fields, regarding tracer development, reconstruction methods, hardware engineering, and sequence design have been employed in pursuit of this objective. In this work, we introduce and thoroughly characterize an improved head-sized MPI scanner with an emphasis on human safety. The scanner is operated by open-source software that enables scanning, monitoring, analysis, and reconstruction, designed to be handled by end users. Our primary focus is to present all technical components of the scanner, with the ultimate objective to investigate brain perfusion imaging in phantom experiments. We have successfully achieved full 3D single- and multi-contrast imaging capabilities at a frame rate of 4 Hz with sufficient sensitivity and resolution for brain applications. To assess system characterization, we devised sensitivity, resolution, perfusion, and multi-contrast experiments, as well as field measurements and sequence analysis. The acquired images were captured using a clinically approved tracer and suitable magnetic field strengths, while adhering to the established human peripheral nerve stimulation thresholds. This advanced scanner holds potential as a tomographic imager for diagnosing conditions such as ischemic stroke or intracranial hemorrhage in environments lacking electromagnetic shielding. Furthermore, due to its low power consumption it may have the potential to facilitate long-term monitoring within intensive care units for various applications.
△ Less
Submitted 23 October, 2023;
originally announced October 2023.
-
Design of a Head Coil for High Resolution Mouse Brain Perfusion Imaging using Magnetic Particle Imaging
Authors:
Matthias Graeser,
Peter Ludewig,
Patryk Szwargulski,
Fynn Foerger,
Tom Liebing,
Nils D. Forkert,
Florian Thieben,
Tim Magnus,
Tobias Knopp
Abstract:
Magnetic Particle Imaging (MPI) is a novel and versatile imaging modality developing towards human application. When up-scaling to human size, the sensitivity of the systems naturally drops as the coil sensitivity depends on the bore diameter. Thus, new methods to push the sensitivity limit further have to be investigated to cope for this loss. In this paper a dedicated surface coil for mice is de…
▽ More
Magnetic Particle Imaging (MPI) is a novel and versatile imaging modality developing towards human application. When up-scaling to human size, the sensitivity of the systems naturally drops as the coil sensitivity depends on the bore diameter. Thus, new methods to push the sensitivity limit further have to be investigated to cope for this loss. In this paper a dedicated surface coil for mice is developed, improving the sensitivity in cerebral imaging applications. Similar to MRI the developed surface coil improves the sensitivity due to the closer vicinity to the region of interest. With the developed surface coil presented in this work, it is possible to image tracer samples containing only 896 pg Fe and detect even small vessels and anatomical structures within a wild type mouse model. As current sensitivity measures require a tracer system a new method for determining a sensitivity measure without this requirement is presented and verified to enable comparison between MPI receiver systems.
△ Less
Submitted 25 May, 2022; v1 submitted 24 April, 2020;
originally announced April 2020.