Skip to main content

Showing 1–5 of 5 results for author: Flanagan, J W

Searching in archive physics. Search in all archives.
.
  1. arXiv:1507.02578  [pdf, other

    physics.acc-ph physics.ins-det

    Operation of the CESR-TA vertical beam size monitor at $E_{\rm b}$=4 GeV

    Authors: J. P. Alexander, C. Conolly, E. Edwards, J. W. Flanagan, E. Fontes, B. K. Heltsley, A. Lyndaker, D. P. Peterson, N. T. Rider, D. L. Rubin, R. Seeley, J. Shanks

    Abstract: We describe operation of the CESR-TA vertical beam size monitor (xBSM) with $e^\pm$ beams with $E_{\rm b}$=4 GeV. The xBSM measures vertical beam size by imaging synchrotron radiation x-rays through an optical element onto a detector array of 32 InGaAs photodiodes with 50 $μ$m pitch. The device has previously been successfully used to measure vertical beam sizes of 10-100 $μ$m on a bunch-by-bunch,… ▽ More

    Submitted 5 August, 2015; v1 submitted 9 July, 2015; originally announced July 2015.

    Comments: 9 pages, 23 figures, 2 tables, published by Nucl. Instr. Meth. A

    Journal ref: Nuclear Inst. and Methods in Physics Research, A (2015), pp. 127-134

  2. arXiv:1408.3308  [pdf, other

    physics.ins-det physics.acc-ph

    Design and performance of coded aperture optical elements for the CESR-TA x-ray beam size monitor

    Authors: J. P. Alexander, A. Chatterjee, C. Conolly, E. Edwards, M. P. Ehrlichman, J. W. Flanagan, E. Fontes, B. K. Heltsley, A. Lyndaker, D. P. Peterson, N. T. Rider, D. L. Rubin, R. Seeley, J. Shanks

    Abstract: We describe the design and performance of optical elements for an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2-5~$GeV. X-rays produced by a hard-bend magnet pass through a single- or multiple-slit (coded a… ▽ More

    Submitted 14 August, 2014; originally announced August 2014.

    Comments: 9 pages, 13 figures, 3 tables, submitted to Nucl. Instrum. Meth. Phys. Res. A

    Journal ref: Nuclear Inst. and Methods in Physics Research, A (2014), pp. 467-474

  3. arXiv:1311.6769  [pdf, other

    physics.ins-det physics.acc-ph

    Vertical beam size measurement in the CESR-TA $e^+e^-$ storage ring using x-rays from synchrotron radiation

    Authors: J. P. Alexander, A. Chatterjee, C. Conolly, E. Edwards, M. P. Ehrlichman, E. Fontes, B. K. Heltsley, W. Hopkins, A. Lyndaker, D. P. Peterson, N. T. Rider, D. L. Rubin, J. Savino, R. Seeley, J. Shanks, J. W. Flanagan

    Abstract: We describe the construction and operation of an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring using synchrotron radiation. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2~$GeV. At such beam energies the xBSM images x-rays of $ε\approx$1-10$~$keV (… ▽ More

    Submitted 3 March, 2014; v1 submitted 26 November, 2013; originally announced November 2013.

    Comments: 35 pages, 62 figures, version published by Nuclear Instruments and Methods in Physics Research A. Nuclear Instruments & Methods in Physics Research A (2014)

    Journal ref: J.P. Alexander et al., Nucl. Inst. and Methods in Phys. Research, A 748C (2014), 96

  4. Observation of Vertical Betatron Sideband due to Electron Clouds in the KEKB LER

    Authors: J. W. Flanagan, K. Ohmi, H. Fukuma, S. Hiramatsu, M. Tobiyama, E. Perevedentsev

    Abstract: The effects of electron clouds on positively-charged beams have been an active area of research in recent years at particle accelerators around the world. Transverse beam-size blow-up due to electron clouds has been observed in some machines, and is considered to be a major limiting factor in the development of higher-current, higher-luminosity electron-positron colliders. The leading proposed m… ▽ More

    Submitted 19 January, 2005; v1 submitted 29 July, 2004; originally announced July 2004.

    Comments: 5 pages, 7 figures, submitted to Phys. Rev. Lett; expanded discussion, fixed figure, fixed typos; shortened for publication

    Journal ref: Phys.Rev.Lett. 94 (2005) 054801

  5. arXiv:physics/0401155  [pdf

    physics.acc-ph

    Negative Momentum Compaction at KEKB

    Authors: H. Ikeda, J. W. Flanagan, H. Fukuma, S. Hiramatsu, T. Ieiri, H. Koiso, T. Mimashi, T. Mitsuhashi

    Abstract: KEKB is a high luminosity e+e- collider for studying B mesons and has achieved the design luminosity of 1034cm-2s-1 in 2003. In order to get higher luminosity, we tested negative momentum compaction optics in the summer of 2003. We measured the bunch length using three methods at 0.7mA to 1.17mA bunch current and confirmed the length was shortened with the negative momentum compaction optics.

    Submitted 28 January, 2004; originally announced January 2004.

    Comments: Invited talk at the Workshop on e+e- in the 1-2 GeV range, Alghero, Italy, September 2003 (eConf C0309101)