-
Embedding the Timepix4 in Micro-Pattern Gaseous Detectors
Authors:
L. Scharenberg,
J. Alozy,
W. Billereau,
F. Brunbauer,
M. Campbell,
P. Carbonez,
K. J. Flöthner,
F. Garcia,
A. Garcia-Tejedor,
T. Genetay,
K. Heijhoff,
D. Janssens,
S. Kaufmann,
M. Lisowska,
X. Llopart,
M. Mager,
B. Mehl,
H. Muller,
R. de Oliveira,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
F. Piernas Diaz,
A. Rodrigues,
L. Ropelewski
, et al. (5 additional authors not shown)
Abstract:
The combination of Micro-Pattern Gaseous Detectors (MPGDs) and pixel charge readout enables specific experimental opportunities. Using the Timepix4 for the readout is advantageous because of its size (around 7 cm^2 active area) and its Through Silicon Vias. The latter enables to connect to the Timepix4 from the back side. Thus, it can be tiled on four sides, allowing it to cover large areas withou…
▽ More
The combination of Micro-Pattern Gaseous Detectors (MPGDs) and pixel charge readout enables specific experimental opportunities. Using the Timepix4 for the readout is advantageous because of its size (around 7 cm^2 active area) and its Through Silicon Vias. The latter enables to connect to the Timepix4 from the back side. Thus, it can be tiled on four sides, allowing it to cover large areas without loss of active area.
Here, the first results of reading out MPGDs with the Timepix4 are presented. Measurements with a Gas Electron Multiplier (GEM) detector show that event selection based on geometrical parameters of the interaction is possible, X-ray imaging studies can be performed, as well as energy and time-resolved measurements. In parallel, the embedding of a Timepix4 into a micro-resistive Well (uRWell) amplification structure is explored. The first mechanical tests have been successful. The status of the electrical functionality is presented, as well as simulation studies on the signal induction in such a device.
△ Less
Submitted 16 March, 2025;
originally announced March 2025.
-
Drift time calibration of the ultra-low material budget GEM-based TPC for MIXE
Authors:
X. Zhao,
M. W. Heiss,
F. Garcia,
B. J. Zeh,
I. Briki,
K. J. Flöthner,
G. Janka,
L. Scharenberg,
B. Banto-Oberhauser,
H. Müller,
S. Biswas,
T. Prokscha,
A. Amato
Abstract:
Muon-Induced X-ray Emission (MIXE) is a non-destructive analytical technique that leverages negative muons to probe elemental and isotopic compositions by detecting characteristic muonic X-rays emitted during atomic cascades and gamma rays from nuclear capture processes. By controlling the muon beam momentum, MIXE enables depth-resolved analysis, spanning microns to centimeters, making it ideal fo…
▽ More
Muon-Induced X-ray Emission (MIXE) is a non-destructive analytical technique that leverages negative muons to probe elemental and isotopic compositions by detecting characteristic muonic X-rays emitted during atomic cascades and gamma rays from nuclear capture processes. By controlling the muon beam momentum, MIXE enables depth-resolved analysis, spanning microns to centimeters, making it ideal for studying compositional variations in fragile, valuable, or operando samples. To enhance its capabilities, we integrated a twin Time Projection Chamber (TPC) tracker with Gas Electron Multiplier (GEM) amplification stages, allowing precise measurement of muon trajectories. A custom-built fiber detector with scintillating fibers and a Silicon Photomultiplier (SiPM) provides permille-level accuracy in drift velocity calibration, essential for accurate spatial reconstruction. This advanced setup correlates muon stopping points with X-ray emissions, paving the way towards element-sensitive imaging and establishing MIXE as a unique tool for high-resolution, depth-specific elemental analysis across diverse scientific applications.
△ Less
Submitted 24 May, 2025; v1 submitted 17 January, 2025;
originally announced January 2025.
-
Application of the VMM3a/SRS: A t0-less TWIN GEM-based TPC
Authors:
K. J. Flöthner,
F. Garcia,
B. Oberhauser,
F. Brunbauer,
M. W. Heiss,
D. Janssens,
B. Ketzer,
M. Lisowska,
M. Meurer,
H. Muller,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewsk,
J. Samarati,
F. Sauli,
L. Scharenberg,
M. van Stenis,
A. Utrobicic,
R. Veenhof
Abstract:
Integrating the ATLAS/BNL VMM3a ASIC (Application Specific Integrated Circuit) into the RD51/SRS (Scalable Readout System) provides a self-triggered continuous readout system for various gaseous detectors. Since the system allows flexible parameters, such as switching the polarity, adjusting electronics gain or different peaking times, the settings can be adjusted for a wide range of detectors. Th…
▽ More
Integrating the ATLAS/BNL VMM3a ASIC (Application Specific Integrated Circuit) into the RD51/SRS (Scalable Readout System) provides a self-triggered continuous readout system for various gaseous detectors. Since the system allows flexible parameters, such as switching the polarity, adjusting electronics gain or different peaking times, the settings can be adjusted for a wide range of detectors. The system allows particles to be recorded with a MHz interaction rate in energy, space, and time.
The system will be introduced in the beginning, and short examples will be given for different applications. After, the Twin GEM TPC will be discussed in more detail to show the benefits of such a trigger-less system in combination with the Twin configuration. Last, a few results for the tracking performance and the possibility to operate as a tracking telescope will be shown. Thus, this presents the possibility of an extremely low material budget tracking system suitable for tracking from high to low-energy particle beams.
△ Less
Submitted 17 January, 2025;
originally announced January 2025.
-
The Ultra-Low material budget GEM based TPC for tracking with VMM3a readout
Authors:
F. Garcia,
K. J. Flöthner,
A. Amato,
S. Biswas,
F. M. Brunbauer,
M. W. Heiss,
G. Janka,
D. Janssens,
M. Lisowska,
M. Meurer,
H. Muller,
B. Banto Oberhauser,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
T. Prokscha,
L. Ropelewski,
L. Scharenberg,
J. Samarati,
F. Sauli,
M. van Stenis,
R. Veenhof,
B. Zeh,
X. Zhao
Abstract:
The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28\% X/X$_0$ and can be further reduced by decreasing the thickness of the gas tra…
▽ More
The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28\% X/X$_0$ and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. Thus, it provides excellent position reconstruction and reduced multi-scattering. This detector consists of two GEM-TPCs with drift fields in opposite directions, achieved by rotating one 180 degrees in the middle plane with respect to the other. These two GEM-TPCs share the same gas volume, i.e., inside a single vessel. This configuration is called a TWIN configuration. The results presented in this work were measured using the newly integrated VMM3a/SRS readout electronics, an important milestone in improving overall performance and capabilities. In 2024, this detector was tested at the H4 beamline of the SPS at CERN, using muons and pions and with different gas mixtures like, for instance: Ar/CO$_2$ (70/30 \%), He/CO$_2$ (70/30 \%) and He/CO$_2$ (90/10 \%). The helium-based mixtures were used to commission the detector to track low momenta muons required in the PSI muon-induced X-ray emission (MIXE) experiment. The results obtained from these measurements, a brief discussion of the methodology used for the data analysis, and a comparison of the spatial resolution for different gas mixtures will be presented.
△ Less
Submitted 18 March, 2025; v1 submitted 16 January, 2025;
originally announced January 2025.
-
PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration
Authors:
Y. Meng,
R. Aleksan,
Y. Angelis,
J. Bortfeld,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datt,
K. Degmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
Z. Li,
M. Lisowska,
J. Liu
, et al. (27 additional authors not shown)
Abstract:
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area…
▽ More
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 $\times$ 10 $\text{cm}^2$ area prototypes and a 20 $\times$ 20 $\text{cm}^2$ prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.
△ Less
Submitted 9 January, 2025;
originally announced January 2025.
-
Towards MPGDs with embedded pixel ASICs
Authors:
L. Scharenberg,
J. Alozy,
W. Billereau,
F. Brunbauer,
M. Campbell,
P. Carbonez,
K. J. Flöthner,
F. Garcia,
A. Garcia-Tejedor,
T. Genetay,
K. Heijhoff,
D. Janssens,
S. Kaufmann,
M. Lisowska,
X. Llopart,
M. Mager,
B. Mehl,
H. Muller,
R. de Oliveira,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
F. Piernas Diaz,
A. Rodrigues,
L. Ropelewski
, et al. (5 additional authors not shown)
Abstract:
Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low material budget, X-ray polarimetry at low energies ($\lessapprox$ 2 keV) or rare-event searches which profit from event selection based on geometrical parameters.…
▽ More
Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low material budget, X-ray polarimetry at low energies ($\lessapprox$ 2 keV) or rare-event searches which profit from event selection based on geometrical parameters. In this article, the idea of embedding a pixel ASIC - specifically the Timepix4 - into a micro-pattern gaseous amplification stage is illustrated. Furthermore, the first results of reading out a triple-GEM detector with the Timepix4 (GEMPix4) are shown, including the first X-ray images taken with a Timepix4 utilising Through Silicon Vias (TSVs). Lastly, a new readout concept is presented, called the 'Silicon Readout Board', extending the use of pixel ASICs to read out gaseous detectors to a wider range of HEP applications.
△ Less
Submitted 22 December, 2024;
originally announced December 2024.
-
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
Authors:
A. Kallitsopoulou,
R. Aleksan,
Y. Angelis,
S. Aune,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
D. Desforge,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger
, et al. (27 additional authors not shown)
Abstract:
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon…
▽ More
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.
△ Less
Submitted 29 October, 2024;
originally announced November 2024.
-
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
Authors:
M. Lisowska,
R. Aleksan,
Y. Angelis,
S. Aune,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Dehmelt,
G. Fanourakis,
S. Ferry,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
C. C. Lai,
P. Legou
, et al. (33 additional authors not shown)
Abstract:
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for…
▽ More
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.
△ Less
Submitted 9 December, 2024; v1 submitted 13 July, 2024;
originally announced July 2024.
-
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
Authors:
X. Wang,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Degmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
I. Maniatis
, et al. (26 additional authors not shown)
Abstract:
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bomb…
▽ More
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.
△ Less
Submitted 30 July, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
-
Spatial resolution improvements with finer-pitch GEMs
Authors:
K. J. Flöthner,
L. Scharenberg,
A. Brask,
F. Brunbauer,
F. Garcia,
D. Janssens,
B. Ketzer,
M. Lisowska,
H. Muller,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
M. Van Stenis,
R. Veenhof
Abstract:
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In t…
▽ More
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In this paper, the results from studies with a triple-GEM detector with an X-Y-strip readout anode are presented. It is demonstrated that GEMs with a finer hole pitch of here 90 um improve the detector's spatial resolution. Within these studies, also the impact of the front-end electronics on the spatial resolution was investigated, which is briefly discussed in the paper.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Single channel PICOSEC Micromegas detector with improved time resolution
Authors:
A. Utrobicic,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Dehmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger
, et al. (25 additional authors not shown)
Abstract:
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing perfo…
▽ More
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Characterisation of resistive MPGDs with 2D readout
Authors:
L. Scharenberg,
F. Brunbauer,
H. Danielson,
Z. Fang,
K. J. Flöthner,
F. Garcia,
D. Janssens,
M. Lisowska,
J. Liu,
Y. Lyu,
B. Mehl,
H. Muller,
R. de Oliveira,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
O. Pizzirusso,
L. Ropelewski,
J. Samarati,
M. Shao,
A. Teixeira,
M. Van Stenis,
R. Veenhof,
Z. Zhang,
Y. Zhou
Abstract:
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A uRWELL prototype is investigated in view of its use as a reference tracking detecto…
▽ More
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A uRWELL prototype is investigated in view of its use as a reference tracking detector in a future gaseous beam telescope. A MicroMegas prototype with a fine-pitch mesh (730 line-pairs-per-inch) is investigated, both for comparison and to profit from the better field uniformity and thus the ability to operate the detector more stable at high gains. Furthermore, the measurements are another application of the RD51 VMM3a/SRS electronics.
△ Less
Submitted 6 February, 2024;
originally announced February 2024.
-
Studying signals in particle detectors with resistive elements such as the 2D resistive strip bulk MicroMegas
Authors:
Djunes Janssens,
Florian Brunbauer,
Karl Jonathan Flöthner,
Marta Lisowska,
Hans Muller,
Eraldo Oliveri,
Giorgio Orlandini,
Werner Riegler,
Leszek Ropelewski,
Heinrich Schindler,
Lucian Scharenberg,
Antonija Utrobicic,
Rob Veenhof
Abstract:
As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or performance. The extended form of the Ramo-Shockley theorem for conductive media has been applied to a 1 M$Ω$/$\Box$ 2D resistive strip bulk MM to calculate the signal'…
▽ More
As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or performance. The extended form of the Ramo-Shockley theorem for conductive media has been applied to a 1 M$Ω$/$\Box$ 2D resistive strip bulk MM to calculate the signal's spreading over neighbouring channels using an 80 GeV/c muon track. For this geometry, the dynamic weighting potential was obtained numerically using a finite element solver by applying a junction condition and coordinate scaling technique to accurately represent the boundary conditions of a $10\times 10$ cm$^2$ active area. Using test beam measurements, the results of this model will be used to benchmark this microscopic modelling methodology for signal induction in resistive particle detectors.
△ Less
Submitted 4 April, 2023;
originally announced April 2023.
-
A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution
Authors:
Antonija Utrobicic,
Yannis Angelis,
Stephan Aune,
Jonathan Bortfeldt,
Florian Brunbauer,
Evridiki Chatzianagnostou,
Klaus Dehmelt,
Daniel Desforge,
George Fanourakis,
Karl Jonathan Floethner,
Michele Gallinaro,
Francisco Garcia,
Prakhar Garg,
Ioannis Giomataris,
Kondo Gnanvo,
Thomas Gustavsson,
Francisco Jose Iguaz,
Djunes Janssens,
Alexandra Kallitsopoulou,
Marinko Kovacic,
Philippe Legou,
Marta Lisowska,
Jianbei Liu,
Michael Lupberger,
Simona Malace
, et al. (20 additional authors not shown)
Abstract:
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics exp…
▽ More
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm$^2$ suffered from degraded timing resolution due to the non-uniformity of the preamplification gap. A new 100 cm$^2$ detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over measured pads and a time resolution below 25 ps. More recent measurements with a new thinner drift gap detector module and newly developed RF pulse amplifiers show that the resolution can be enhanced to a level of 17~ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.
△ Less
Submitted 31 March, 2023;
originally announced April 2023.
-
Towards robust PICOSEC Micromegas precise timing detectors
Authors:
Marta Lisowska,
Yannis Angelis,
Stephan Aune,
Jonathan Bortfeldt,
Florian Brunbauer,
Evridiki Chatzianagnostou,
Klaus Dehmelt,
Daniel Desforge,
George Fanourakis,
Karl Jonathan Floethner,
Michele Gallinaro,
Francisco Garcia,
Prakhar Garg,
Ioannis Giomataris,
Kondo Gnanvo,
Thomas Gustavsson,
Francisco Jose Iguaz,
Djunes Janssens,
Alexandra Kallitsopoulou,
Marinko Kovacic,
Philippe Legou,
Jianbei Liu,
Michael Lupberger,
Simona Malace,
Ioannis Maniatis
, et al. (21 additional authors not shown)
Abstract:
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. The objective of this work is to improve the PICOSEC MM detec…
▽ More
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects; i.e. integration of resistive MM and carbon-based photocathodes; while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below 20 ps for an individual pad obtained with the 10x10 cm^2 area resistive PICOSEC MM of 20 MOhm/sq showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B4C) photocathode presented a time resolution below 35 ps; opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
The novel XYU-GEM to resolve ambiguities
Authors:
K. J. Flöthner,
F. Brunbauer,
S. Ferry,
F. Garcia,
D. Janssens,
B. Ketzer,
M. Lisowska,
H. Muller,
R. de Oliveira,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
F. Sauli,
L. Scharenberg,
M. van Stenis,
A. Utrobicic,
R. Veenhof
Abstract:
Removing ambiguities within a single stage becomes crucial when one can not use multiple detectors behind each other to resolve them which naturally is the case for neutral radiation. An example would be RICH detectors. Commonly pixilated readout is choosen for this purpose. However, this causes a remarkable increase in quantity of channels and does not scale up well. Therefore, the XYU-GEM was pr…
▽ More
Removing ambiguities within a single stage becomes crucial when one can not use multiple detectors behind each other to resolve them which naturally is the case for neutral radiation. An example would be RICH detectors. Commonly pixilated readout is choosen for this purpose. However, this causes a remarkable increase in quantity of channels and does not scale up well. Therefore, the XYU-GEM was proposed as a three coordinate strip-readout which is combined with a triple GEM detector. The readout complements a common XY readout with an additional projection which is tilted by 45°. The overdetermination due to three projections can be used to resovle ambiguities. Following the detector design will be explained, first measurements discussed to understand the response of the detector and a way to change the charge sharing without changing the manufacturing parameters of the readout.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
Performance of the new RD51 VMM3a/SRS beam telescope---studying MPGDs simultaneously in energy, space and time at high rates
Authors:
L. Scharenberg,
J. Bortfeldt,
F. Brunbauer,
K. Desch,
K. Flöthner,
F. Garcia,
D. Janssens,
M. Lisowska,
H. Muller,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
D. Sorvisto,
M. van Stenis,
R. Veenhof
Abstract:
The RD51 collaboration maintains a common infrastructure at CERN for its R & D activities, including two beam telescopes for test beam campaigns. Recently, one of the beam telescopes has been equipped and commissioned with new multi-channel and charge-sensitive front-end electronics based on the ATLAS/BNL VMM3a front-end ASIC and the RD51 Scalable Readout System (SRS). This allows to read out the…
▽ More
The RD51 collaboration maintains a common infrastructure at CERN for its R & D activities, including two beam telescopes for test beam campaigns. Recently, one of the beam telescopes has been equipped and commissioned with new multi-channel and charge-sensitive front-end electronics based on the ATLAS/BNL VMM3a front-end ASIC and the RD51 Scalable Readout System (SRS). This allows to read out the detectors at high rates (up to the MHz regime) with electronics time resolutions of the order of 1 ns and the ability to handle different detector types and sizes, due to a larger dynamic range compared to the previous front-end electronics based on the APV25 ASIC. Having studied and improved the beam telescope's performance over the course of three test beam campaigns, the results are presented in this paper.
△ Less
Submitted 16 February, 2023;
originally announced February 2023.
-
Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D
Authors:
K. Dehmelt,
M. Della Pietra,
H. Muller,
S. E. Tzamarias,
A. White,
S. White,
Z. Zhang,
M. Alviggi,
I. Angelis,
S. Aune,
J. Bortfeldt,
M. Bregant,
F. Brunbauer,
M. T. Camerlingo,
V. Canale,
V. D'Amico,
D. Desforge,
C. Di Donato,
R. Di Nardo,
G. Fanourakis,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo
, et al. (45 additional authors not shown)
Abstract:
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51…
▽ More
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.
△ Less
Submitted 19 March, 2022; v1 submitted 12 March, 2022;
originally announced March 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Rate-capability of the VMM3a Front End in the RD51 Scalable Readout System
Authors:
D. Pfeiffer,
L. Scharenberg,
P. Schwäbig,
S. Alcock,
F. Brunbauer,
M. J. Christensen,
K. Desch,
K. Flöthner,
F. Garcia,
R. Hall-Wilton,
M. Hracek,
G. Iakovidis,
D. Janssens,
J. Kaminski,
M. Lupberger,
H. Muller,
E. Oliveri,
L. Ropelewski,
A. Rusu,
J. Samarati,
M. van Stenis,
A. Utrobicic,
R. Veenhof
Abstract:
The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use…
▽ More
The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use of Micro-Pattern Gaseous Detectors (MPGDs). As part of the integration of the VMM3a into the SRS, the readout and data transfer scheme was optimised to reach a high rate-capability of the entire readout system and profit from the VMM3a's high single-channel rate-capability of 3.6 Mhits/s. The optimisation focused mainly on the handling of the data output stream of the VMM3a, but also on the development of a trigger-logic between the front-end cards and the DAQ computer. In this article, two firmware implementations of the non-ATLAS continuous readout mode are presented, as well as the implementation of the trigger-logic. Afterwards, a short overview on X-ray imaging results is presented, to illustrate the high rate-capability rom an application point-of-view.
△ Less
Submitted 2 February, 2022; v1 submitted 21 September, 2021;
originally announced September 2021.
-
Measurements of the Charging-Up Effect in Gas Electron Multipliers
Authors:
Philip Hauer,
Karl Flöthner,
Dimitri Schaab,
Jonathan Ottnad,
Viktor Ratza,
Markus Ball,
Bernhard Ketzer
Abstract:
GEM are widely used as amplification stages in gaseous detectors exposed to high rates. The GEM consists of a polyimide foil which is coated by two thin copper layers. Charges collected into the holes or created during the amplification process may adhere to the polyimide part inside the holes. This is often accompanied by a change of the effective gain. The effect is commonly known as the chargin…
▽ More
GEM are widely used as amplification stages in gaseous detectors exposed to high rates. The GEM consists of a polyimide foil which is coated by two thin copper layers. Charges collected into the holes or created during the amplification process may adhere to the polyimide part inside the holes. This is often accompanied by a change of the effective gain. The effect is commonly known as the charging-up effect.
This work presents a systematic investigation of the effect under well-controlled and monitored conditions for a single standard GEM foil in Ar/CO$_2$ (90/10) gas for varying rates of X-ray interactions in the detector and for different gains of the foil. In order to cover a wide range of different rates, we apply two different methods. The first one is based on a current measurement while the second one relies on the analysis of $^{55}$Fe spectra over time. Both methods give consistent results, showing an initial increase of the effective gain with time and an asymptotic saturation, which can be well described by a single-exponential function. We find that the characteristic time constants extracted from our measurements scale inversely proportional to the rate of incoming electrons for a given GEM voltage. Introducing characteristic quantities, which describe either the number of incoming electrons per hole or the total number of electrons in a hole per characteristic time, we find consistent numbers for measurements taken at the same GEM voltages. For measurements taken at different GEM voltages, however, also the characteristic total number of electrons inside the hole, which is supposed to take into account the different effective gains, is found to be higher by a factor of about 3.5 for $U_{\rm GEM}=$ 350V ($n_{\rm tot}=8.8\times 10^8$) compared to 400V ($n_{\rm tot}=2.4\times 10^8$). This hints at a residual dependence of the charging-up characteristics on the GEM voltage.
△ Less
Submitted 9 April, 2020; v1 submitted 5 November, 2019;
originally announced November 2019.