-
European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment
Authors:
PIONEER Collaboration,
A. Adelmann,
W. Altmannshofer,
S. Ban,
O. Beesley,
A. Bolotnikov,
T. Brunner,
D. Bryman,
Q. Buat,
L. Caminada,
J. Carlton,
S. Chen,
M. Chiu,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
J. Datta,
B. Davis-Purcell,
A. Deshpande,
A. Di Canto,
A. Ebrahimi,
P. Fisher,
S. Foster,
K. Frahm
, et al. (54 additional authors not shown)
Abstract:
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimen…
▽ More
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimental result $R_{e/μ}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/μ}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.
△ Less
Submitted 14 April, 2025; v1 submitted 8 April, 2025;
originally announced April 2025.
-
Searching for New Physics with DarkLight at the ARIEL Electron-Linac
Authors:
The DarkLight Collaboration,
E. Cline,
R. Corliss,
J. C. Bernauer,
R. Alarcon,
R. Baartman,
S. Benson,
J. Bessuille,
D. Ciarniello,
A. Christopher,
A. Colon,
W. Deconinck,
K. Dehmelt,
A. Deshpande,
J. Dilling,
D. H. Dongwi,
P. Fisher,
T. Gautam,
M. Gericke,
D. Hasell,
M. Hasinoff,
E. Ihloff,
R. Johnston,
R. Kanungo,
J. Kelsey
, et al. (21 additional authors not shown)
Abstract:
The search for a dark photon holds considerable interest in the physics community. Such a force carrier would begin to illuminate the dark sector. Many experiments have searched for such a particle, but so far it has proven elusive. In recent years the concept of a low mass dark photon has gained popularity in the physics community. Of particular recent interest is the $^8$Be and $^4$He anomaly, w…
▽ More
The search for a dark photon holds considerable interest in the physics community. Such a force carrier would begin to illuminate the dark sector. Many experiments have searched for such a particle, but so far it has proven elusive. In recent years the concept of a low mass dark photon has gained popularity in the physics community. Of particular recent interest is the $^8$Be and $^4$He anomaly, which could be explained by a new fifth force carrier with a mass of 17 MeV/$c^2$. The proposed DarkLight experiment would search for this potential low mass force carrier at ARIEL in the 10-20 MeV e$^+$e$^-$ invariant mass range. This proceeding will focus on the experimental design and physics case of the DarkLight experiment.
△ Less
Submitted 14 August, 2022; v1 submitted 8 August, 2022;
originally announced August 2022.
-
Single photon frequency conversion for frequency multiplexed quantum networks in the telecom band
Authors:
Paul Fisher,
Robert Cernansky,
Ben Haylock,
Mirko Lobino
Abstract:
High-speed long-range quantum communication requires combining frequency multiplexed photonic channels with quantum memories. We experimentally demonstrate an integrated quantum frequency conversion protocol that can convert between wavelength division multiplexing channels in the telecom range with an efficiency of $55\pm 8\%$ and a noise subtracted HOM dip visibility of 84.5%. This protocol is b…
▽ More
High-speed long-range quantum communication requires combining frequency multiplexed photonic channels with quantum memories. We experimentally demonstrate an integrated quantum frequency conversion protocol that can convert between wavelength division multiplexing channels in the telecom range with an efficiency of $55\pm 8\%$ and a noise subtracted HOM dip visibility of 84.5%. This protocol is based on a cascaded second order nonlinear interaction and can be used to interface a broad spectrum of frequencies with narrowband quantum memories, or alternatively as a quantum optical transponder, efficiently interfacing different regions of a frequency-multiplexed spectrum.
△ Less
Submitted 5 April, 2021;
originally announced April 2021.
-
Asymptotic turbulent friction in 2D rough-walled flows
Authors:
Alexandre Vilquin,
Julie Jagielka,
Simeon Djambov,
Hugo Herouard,
Patrick Fisher,
Charles-Henri Bruneau,
Pinaki Chakraborty,
Gustavo Gioia,
Hamid Kellay
Abstract:
The friction f is the property of wall-bounded flows that sets the pumping cost of a pipeline, the draining capacity of a river, and other variables of practical relevance. For highly turbulent rough-walled pipe flows, f depends solely on the roughness length scale r, and the f -- r relation may be expressed by the Strickler empirical scaling f $\propto$ r$^{\frac{1}{3}}$. Here, we show experiment…
▽ More
The friction f is the property of wall-bounded flows that sets the pumping cost of a pipeline, the draining capacity of a river, and other variables of practical relevance. For highly turbulent rough-walled pipe flows, f depends solely on the roughness length scale r, and the f -- r relation may be expressed by the Strickler empirical scaling f $\propto$ r$^{\frac{1}{3}}$. Here, we show experimentally that for soap film flows that are the two-dimensional (2D) equivalent of highly turbulent rough-walled pipe flows, f $\propto$ r and the f -- r relation is not the same in 2D as in 3D. Our findings are beyond the purview of the standard theory of friction but consistent with a competing theory in which f is linked to the turbulent spectrum via the spectral exponent $α$: In 3D, $α$ = 5/3 and the theory yields f $\propto$ r$^{\frac{1}{3}}$; in 2D, $α$ = 3 and the theory yields f $\propto$ r.
△ Less
Submitted 1 February, 2021;
originally announced February 2021.
-
An integrated optical device for frequency conversion across the full telecom C-band spectrum
Authors:
Paul Fisher,
Matteo Villa,
Francesco Lenzini,
Mirko Lobino
Abstract:
High-density communication through optical fiber is made possible by Wavelength Division Multiplexing, which is the simultaneous transmission of many discrete signals at different optical frequencies. Vast quantities of data may be transmitted without interference using this scheme but flexible routing of these signals requires an electronic middle step, carrying a cost in latency. We present a te…
▽ More
High-density communication through optical fiber is made possible by Wavelength Division Multiplexing, which is the simultaneous transmission of many discrete signals at different optical frequencies. Vast quantities of data may be transmitted without interference using this scheme but flexible routing of these signals requires an electronic middle step, carrying a cost in latency. We present a technique for frequency conversion across the entire WDM spectrum with a single device, which removes this latency cost. Using an optical waveguide in lithium niobate and two infrared pump beams, we show how to maximize conversion efficiency between arbitrary frequencies by analyzing the role of dispersion in cascaded nonlinear processes. The technique is presented generally and may be applied to any suitable nonlinear material or platform, and to classical or quantum optical signals.
△ Less
Submitted 9 July, 2019;
originally announced July 2019.
-
Measurement of Moller Scattering at 2.5 MeV
Authors:
C. S. Epstein,
R. Johnston,
S. Lee,
J. C. Bernauer,
R. Corliss,
K. Dow,
P. Fisher,
I. Friscic,
D. Hasell,
R. G. Milner,
P. Moran,
S. G. Steadman,
Y. Wang,
J. Dodge,
E. Ihloff,
J. Kelsey,
C. Vidal,
C. M. Cooke
Abstract:
Moller scattering is one of the most fundamental processes in QED. Understanding it to high precision is necessary for a variety of modern nuclear and particle physics experiments. In a recent calculation, existing soft-photon radiative corrections were combined with new hard-photon bremsstrahlung calculations to take into account the effect of photon emission at any photon energy, where the elect…
▽ More
Moller scattering is one of the most fundamental processes in QED. Understanding it to high precision is necessary for a variety of modern nuclear and particle physics experiments. In a recent calculation, existing soft-photon radiative corrections were combined with new hard-photon bremsstrahlung calculations to take into account the effect of photon emission at any photon energy, where the electron mass was included at all steps. To test the calculation, an experiment was carried out using the 3 MV Van de Graaff electrostatic accelerator at the MIT High Voltage Research Laboratory. Momentum spectra at three scattering angles at an incident electron energy of 2.5 MeV are reported here, and compared to the simulated radiative Moller spectra, based on our previous calculation. Good agreement between the measurements and our calculation is observed in the momentum spectrum at the three angles.
△ Less
Submitted 13 April, 2019; v1 submitted 21 March, 2019;
originally announced March 2019.
-
Design and Operation of a Windowless Gas Target Internal to a Solenoidal Magnet for Use with a Megawatt Electron Beam
Authors:
S. Lee,
R. Corliss,
I. Friščić,
R. Alarcon,
S. Aulenbacher,
J. Balewski,
S. Benson,
J. C. Bernauer,
J. Bessuille,
J. Boyce,
J. Coleman,
D. Douglas,
C. S. Epstein,
P. Fisher,
S. Frierson,
M. Garçon,
J. Grames,
D. Hasell,
C. Hernandez-Garcia,
E. Ihloff,
R. Johnston,
K. Jordan,
R. Kazimi,
J. Kelsey,
M. Kohl
, et al. (15 additional authors not shown)
Abstract:
A windowless hydrogen gas target of nominal thickness $10^{19}$ cm$^{-2}$ is an essential component of the DarkLight experiment, which is designed to utilize the megawatt electron beam at an Energy Recovery Linac (ERL). The design of such a target is challenging because the pressure drops by many orders of magnitude between the central, high-density section of the target and the surrounding beamli…
▽ More
A windowless hydrogen gas target of nominal thickness $10^{19}$ cm$^{-2}$ is an essential component of the DarkLight experiment, which is designed to utilize the megawatt electron beam at an Energy Recovery Linac (ERL). The design of such a target is challenging because the pressure drops by many orders of magnitude between the central, high-density section of the target and the surrounding beamline, resulting in laminar, transitional, and finally molecular flow regimes. The target system was assembled and operated at Jefferson Lab's Low Energy Recirculator Facility (LERF) in 2016, and subsequently underwent several revisions and calibration tests at MIT Bates in 2017. The system at dynamic equilibrium was simulated in COMSOL to provide a better understanding of its optimal operation at other working points. We have determined that a windowless gas target with sufficiently high density for DarkLight's experimental needs is feasible in an ERL environment.
△ Less
Submitted 30 May, 2019; v1 submitted 6 March, 2019;
originally announced March 2019.
-
Realization of a Large-Acceptance Faraday Cup for 3 MeV Electrons
Authors:
R. Johnston,
J. Bernauer,
C. M. Cooke,
R. Corliss,
C. S. Epstein,
P. Fisher,
I. Friščić,
D. Hasell,
E. Ihloff,
J. Kelsey,
S. Lee,
R. G. Milner,
P. Moran,
S. G. Steadman,
C. Vidal
Abstract:
The design, construction, installation, and testing of a Faraday Cup intended to measure the current of a 3 MeV, 1 microampere electron beam is described. Built as a current monitor for a Møller scattering measurement at the MIT High Voltage Research Laboratory, the device combines a large angular acceptance with the capability to measure a continuous, low energy beam. Bench studies of its perform…
▽ More
The design, construction, installation, and testing of a Faraday Cup intended to measure the current of a 3 MeV, 1 microampere electron beam is described. Built as a current monitor for a Møller scattering measurement at the MIT High Voltage Research Laboratory, the device combines a large angular acceptance with the capability to measure a continuous, low energy beam. Bench studies of its performance demonstrate current measurements accurate to the percent level at 1 microampere. The Faraday Cup was designed and constructed at MIT and has been in use at the HVRL since 2017, providing a significantly more detailed measurement of beam current than was previously available.
△ Less
Submitted 27 November, 2018;
originally announced November 2018.
-
Posner molecules: From atomic structure to nuclear spins
Authors:
Michael W. Swift,
Chris G. Van de Walle,
Matthew P. A. Fisher
Abstract:
We investigate "Posner molecules", calcium phosphate clusters with chemical formula Ca$_9$(PO$_4$)$_6$. Originally identified in hydroxyapatite, Posner molecules have also been observed as free-floating molecules $in$ $vitro$. The formation and aggregation of Posner molecules have important implications for bone growth, and may also play a role in other biological processes such as the modulation…
▽ More
We investigate "Posner molecules", calcium phosphate clusters with chemical formula Ca$_9$(PO$_4$)$_6$. Originally identified in hydroxyapatite, Posner molecules have also been observed as free-floating molecules $in$ $vitro$. The formation and aggregation of Posner molecules have important implications for bone growth, and may also play a role in other biological processes such as the modulation of calcium and phosphate ion concentrations within the mitochondrial matrix. In this work, we use a first-principles computational methodology to study the structure of Posner molecules, their vibrational spectra, their interactions with other cations, and the process of pairwise bonding. Additionally, we show that the Posner molecule provides an ideal environment for the six constituent $^{31}\text{P}$ nuclear spins to obtain very long spin coherence times. $In$ $vitro$, the spins could provide a platform for liquid-state nuclear magnetic resonance quantum computation. $In$ $vivo$, the spins may have medical imaging applications. The spins have also been suggested as "neural qubits" in a proposed mechanism for quantum processing in the brain.
△ Less
Submitted 15 November, 2017;
originally announced November 2017.
-
Quantum Indistinguishability in Chemical Reactions
Authors:
Matthew P. A. Fisher,
Leo Radzihovsky
Abstract:
Quantum indistinguishability plays a crucial role in many low-energy physical phenomena, from quantum fluids to molecular spectroscopy. It is, however, typically ignored in most high temperature processes, particularly for ionic coordinates, implicitly assumed to be distinguishable, incoherent and thus well-approximated classically. We explore chemical reactions involving small symmetric molecules…
▽ More
Quantum indistinguishability plays a crucial role in many low-energy physical phenomena, from quantum fluids to molecular spectroscopy. It is, however, typically ignored in most high temperature processes, particularly for ionic coordinates, implicitly assumed to be distinguishable, incoherent and thus well-approximated classically. We explore chemical reactions involving small symmetric molecules, and argue that in many situations a full quantum treatment of collective nuclear degrees of freedom is essential. Supported by several physical arguments, we conjecture a "Quantum Dynamical Selection" (QDS) rule for small symmetric molecules that precludes chemical processes that involve direct transitions from orbitally non-symmetric molecular states. As we propose and discuss, the implications of the Quantum Dynamical Selection rule include: (i) a differential chemical reactivity of para- and ortho-hydrogen, (ii) a mechanism for inducing inter-molecular quantum entanglement of nuclear spins, (iii) a new isotope fractionation mechanism, (iv) a novel explanation of the enhanced chemical activity of "Reactive Oxygen Species", (v) illuminating the importance of ortho-water molecules in modulating the quantum dynamics of liquid water, (vi) providing the critical quantum-to-biochemical linkage in the nuclear spin model of the (putative) quantum brain, among others.
△ Less
Submitted 4 October, 2017; v1 submitted 17 July, 2017;
originally announced July 2017.
-
Measurement of the directional sensitivity of DMTPC detectors
Authors:
Cosmin Deaconu,
Michael Leyton,
Ross Corliss,
Gabriela Druitt,
Richard Eggleston,
Natalia Guerrero,
Shawn Henderson,
Jeremy Lopez,
Jocelyn Monroe,
Peter Fisher
Abstract:
The Dark Matter Time Projection Chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling $^{19}$F and $^{12}$C nuclei in low-pressure CF$_4$ gas using optical and charge readout systems. In this paper, we employ measurements from two DMTPC detectors, with operating pressures of 30-60 torr, to develop and validate a model of the directional response and perfo…
▽ More
The Dark Matter Time Projection Chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling $^{19}$F and $^{12}$C nuclei in low-pressure CF$_4$ gas using optical and charge readout systems. In this paper, we employ measurements from two DMTPC detectors, with operating pressures of 30-60 torr, to develop and validate a model of the directional response and performance of such detectors as a function of recoil energy. Using our model as a benchmark, we formulate the necessary specifications for a scalable directional detector with sensitivity comparable to that of current-generation counting (non-directional) experiments, which measure only recoil energy. Assuming the performance of existing DMTPC detectors, as well as current limits on the spin-dependent WIMP-nucleus cross section, we find that a 10-20 kg scale direction-sensitive detector is capable of correlating the measured direction of nuclear recoils with the predicted direction of incident dark matter particles and providing decisive (3$σ$) confirmation that a candidate signal from a non-directional experiment was indeed induced by elastic scattering of dark matter particles off of target nuclei.
△ Less
Submitted 29 May, 2017; v1 submitted 16 May, 2017;
originally announced May 2017.
-
Direct characterization of a nonlinear photonic circuit's wave function with laser light
Authors:
Francesco Lenzini,
Alexander N. Poddubny,
James Titchener,
Paul Fisher,
Andreas Boes,
Sachin Kasture,
Ben Haylock,
Matteo Villa,
Arnan Mitchell,
Alexander S. Solntsev,
Andrey A. Sukhorukov,
Mirko Lobino
Abstract:
Integrated photonics is a leading platform for quantum technologies including nonclassical state generation \cite{Vergyris:2016-35975:SRP, Solntsev:2014-31007:PRX, Silverstone:2014-104:NPHOT, Solntsev:2016:RPH}, demonstration of quantum computational complexity \cite{Lamitral_NJP2016} and secure quantum communications \cite{Zhang:2014-130501:PRL}. As photonic circuits grow in complexity, full quan…
▽ More
Integrated photonics is a leading platform for quantum technologies including nonclassical state generation \cite{Vergyris:2016-35975:SRP, Solntsev:2014-31007:PRX, Silverstone:2014-104:NPHOT, Solntsev:2016:RPH}, demonstration of quantum computational complexity \cite{Lamitral_NJP2016} and secure quantum communications \cite{Zhang:2014-130501:PRL}. As photonic circuits grow in complexity, full quantum tomography becomes impractical, and therefore an efficient method for their characterization \cite{Lobino:2008-563:SCI, Rahimi-Keshari:2011-13006:NJP} is essential. Here we propose and demonstrate a fast, reliable method for reconstructing the two-photon state produced by an arbitrary quadratically nonlinear optical circuit. By establishing a rigorous correspondence between the generated quantum state and classical sum-frequency generation measurements from laser light, we overcome the limitations of previous approaches for lossy multimode devices \cite{Liscidini:2013-193602:PRL, Helt:2015-1460:OL}. We applied this protocol to a multi-channel nonlinear waveguide network, and measured a 99.28$\pm$0.31\% fidelity between classical and quantum characterization. This technique enables fast and precise evaluation of nonlinear quantum photonic networks, a crucial step towards complex, large-scale, device production.
△ Less
Submitted 6 March, 2017; v1 submitted 2 March, 2017;
originally announced March 2017.
-
Quantum correlation measurements in interferometric gravitational wave detectors
Authors:
D. V. Martynov,
V. V. Frolov,
S. Kandhasamy,
K. Izumi,
H. Miao,
N. Mavalvala,
E. D. Hall,
R. Lanza,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
S. B. Anderson,
A. Ananyeva,
S. Appert,
K. Arai,
S. M. Aston,
S. W. Ballmer,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
I. Bartos,
J. C. Batch
, et al. (177 additional authors not shown)
Abstract:
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the…
▽ More
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer for the first time.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
-
Scalable ion-photon quantum interface based on integrated diffractive mirrors
Authors:
M. Ghadimi,
V. Blūms,
B. G. Norton,
P. M. Fisher,
S. C. Connell,
J. M. Amini,
C. Volin,
H. Hayden,
C. S. Pai,
D. Kielpinski,
M. Lobino,
E. W. Streed
Abstract:
Quantum networking links quantum processors through remote entanglement for distributed quantum information processing (QIP) and secure long-range communication. Trapped ions are a leading QIP platform, having demonstrated universal small-scale processors and roadmaps for large-scale implementation. Overall rates of ion-photon entanglement generation, essential for remote trapped ion entanglement,…
▽ More
Quantum networking links quantum processors through remote entanglement for distributed quantum information processing (QIP) and secure long-range communication. Trapped ions are a leading QIP platform, having demonstrated universal small-scale processors and roadmaps for large-scale implementation. Overall rates of ion-photon entanglement generation, essential for remote trapped ion entanglement, are limited by coupling efficiency into single mode fibres5 and scaling to many ions. Here we show a microfabricated trap with integrated diffractive mirrors that couples 4.1(6)% of the fluorescence from a $^{174}$Yb$^+$ ion into a single mode fibre, nearly triple the demonstrated bulk optics efficiency. The integrated optic collects 5.8(8)% of the π transition fluorescence, images the ion with sub-wavelength resolution, and couples 71(5)% of the collected light into the fibre. Our technology is suitable for entangling multiple ions in parallel and overcomes mode quality limitations of existing integrated optical interconnects. In addition, the efficiencies are sufficient for fault tolerant QIP.
△ Less
Submitted 30 June, 2016;
originally announced July 2016.
-
Nine Channel Mid-Power Bipolar Pulse Generator Based on a Field Programmable Gate Array
Authors:
Ben Haylock,
Francesco Lenzini,
Sachin Kasture,
Paul Fisher,
Erik W. Streed,
Mirko Lobino
Abstract:
Many channel arbitrary pulse sequence generation is required for the electro-optic reconfiguration of optical waveguide networks in Lithium Niobate. Here we describe a scalable solution to the requirement for mid-power bipolar parallel outputs, based on pulse patterns generated by an externally clocked field programmable gate array (FPGA). Positive and negative pulses can be generated at repetitio…
▽ More
Many channel arbitrary pulse sequence generation is required for the electro-optic reconfiguration of optical waveguide networks in Lithium Niobate. Here we describe a scalable solution to the requirement for mid-power bipolar parallel outputs, based on pulse patterns generated by an externally clocked field programmable gate array (FPGA). Positive and negative pulses can be generated at repetition rates from up to 80~MHz with pulse width adjustable in increments of 1.6~ns across nine independent outputs. Each channel can provide 1.5W of RF power and it can be synchronised with the operation of other components in an optical network such as light sources and detectors through an external clock with adjustable delay.
△ Less
Submitted 27 June, 2016;
originally announced June 2016.
-
The Sensitivity of the Advanced LIGO Detectors at the Beginning of Gravitational Wave Astronomy
Authors:
D. V. Martynov,
E. D. Hall,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
R. A. Anderson,
S. B. Anderson,
K. Arai,
M. A. Arain,
S. M. Aston,
L. Austin,
S. W. Ballmer,
M. Barbet,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
M. A. Barton,
I. Bartos,
J. C. Batch,
A. S. Bell,
I. Belopolski,
J. Bergman
, et al. (239 additional authors not shown)
Abstract:
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than…
▽ More
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than $10^{-23}/\sqrt{\text{Hz}}$ was achieved around 100 Hz. Understanding both the fundamental and the technical noise sources was critical for increasing the observable volume in the universe. The average distance at which coalescing binary black hole systems with individual masses of 30 $M_\odot$ could be detected was 1.3 Gpc. Similarly, the range for binary neutron star inspirals was about 75 Mpc. With respect to the initial detectors, the observable volume of Universe increased respectively by a factor 69 and 43. These improvements allowed Advanced LIGO to detect the gravitational wave signal from the binary black hole coalescence, known as GW150914.
△ Less
Submitted 10 February, 2018; v1 submitted 1 April, 2016;
originally announced April 2016.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Quantum Cognition: The possibility of processing with nuclear spins in the brain
Authors:
Matthew P. A. Fisher
Abstract:
The possibility that quantum processing with nuclear spins might be operative in the brain is proposed and then explored. Phosphorus is identified as the unique biological element with a nuclear spin that can serve as a qubit for such putative quantum processing - a neural qubit - while the phosphate ion is the only possible qubit-transporter. We identify the "Posner molecule",…
▽ More
The possibility that quantum processing with nuclear spins might be operative in the brain is proposed and then explored. Phosphorus is identified as the unique biological element with a nuclear spin that can serve as a qubit for such putative quantum processing - a neural qubit - while the phosphate ion is the only possible qubit-transporter. We identify the "Posner molecule", $\text{Ca}_9 (\text{PO}_4)_6$, as the unique molecule that can protect the neural qubits on very long times and thereby serve as a (working) quantum-memory. A central requirement for quantum-processing is quantum entanglement. It is argued that the enzyme catalyzed chemical reaction which breaks a pyrophosphate ion into two phosphate ions can quantum entangle pairs of qubits. Posner molecules, formed by binding such phosphate pairs with extracellular calcium ions, will inherit the nuclear spin entanglement. A mechanism for transporting Posner molecules into presynaptic neurons during a "kiss and run" exocytosis, which releases neurotransmitters into the synaptic cleft, is proposed. Quantum measurements can occur when a pair of Posner molecules chemically bind and subsequently melt, releasing a shower of intra-cellular calcium ions that can trigger further neurotransmitter release and enhance the probability of post-synaptic neuron firing. Multiple entangled Posner molecules, triggering non-local quantum correlations of neuron firing rates, would provide the key mechanism for neural quantum processing. Implications, both in vitro and in vivo, are briefly mentioned.
△ Less
Submitted 28 August, 2015; v1 submitted 19 August, 2015;
originally announced August 2015.
-
The DarkLight Experiment: A Precision Search for New Physics at Low Energies
Authors:
J. Balewski,
J. Bernauer,
J. Bessuille,
R. Corliss,
R. Cowan,
C. Epstein,
P. Fisher,
D. Hasell,
E. Ihloff,
Y. Kahn,
J. Kelsey,
R. Milner,
S. Steadman,
J. Thaler,
C. Tschalaer,
C. Vidal,
S. Benson,
J. Boyce,
D. Douglas,
P. Evtushenko,
C. Hernandez-Garcia,
C. Keith,
C. Tennant,
S. Zhang,
R. Alarcon
, et al. (15 additional authors not shown)
Abstract:
We describe the current status of the DarkLight experiment at Jefferson Laboratory. DarkLight is motivated by the possibility that a dark photon in the mass range 10 to 100 MeV/c$^2$ could couple the dark sector to the Standard Model. DarkLight will precisely measure electron proton scattering using the 100 MeV electron beam of intensity 5 mA at the Jefferson Laboratory energy recovering linac inc…
▽ More
We describe the current status of the DarkLight experiment at Jefferson Laboratory. DarkLight is motivated by the possibility that a dark photon in the mass range 10 to 100 MeV/c$^2$ could couple the dark sector to the Standard Model. DarkLight will precisely measure electron proton scattering using the 100 MeV electron beam of intensity 5 mA at the Jefferson Laboratory energy recovering linac incident on a windowless gas target of molecular hydrogen. The complete final state including scattered electron, recoil proton, and e+e- pair will be detected. A phase-I experiment has been funded and is expected to take data in the next eighteen months. The complete phase-II experiment is under final design and could run within two years after phase-I is completed. The DarkLight experiment drives development of new technology for beam, target, and detector and provides a new means to carry out electron scattering experiments at low momentum transfers.
△ Less
Submitted 15 December, 2014;
originally announced December 2014.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier
Authors:
M. Demarteau,
R. Lipton,
H. Nicholson,
I. Shipsey,
D. Akerib,
A. Albayrak-Yetkin,
J. Alexander,
J. Anderson,
M. Artuso,
D. Asner,
R. Ball,
M. Battaglia,
C. Bebek,
J. Beene,
Y. Benhammou,
E. Bentefour,
M. Bergevin,
A. Bernstein,
B. Bilki,
E. Blucher,
G. Bolla,
D. Bortoletto,
N. Bowden,
G. Brooijmans,
K. Byrum
, et al. (189 additional authors not shown)
Abstract:
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss…
▽ More
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
DarkLight: A Search for Dark Forces at the Jefferson Laboratory Free-Electron Laser Facility
Authors:
J. Balewski,
J. Bernauer,
W. Bertozzi,
J. Bessuille,
B. Buck,
R. Cowan,
K. Dow,
C. Epstein,
P. Fisher,
S. Gilad,
E. Ihloff,
Y. Kahn,
A. Kelleher,
J. Kelsey,
R. Milner,
C. Moran,
L. Ou,
R. Russell,
B. Schmookler,
J. Thaler,
C. Tschalär,
C. Vidal,
A. Winnebeck,
S. Benson,
C. Gould
, et al. (42 additional authors not shown)
Abstract:
We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.
We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.
△ Less
Submitted 19 July, 2013; v1 submitted 16 July, 2013;
originally announced July 2013.
-
Transmission of High-Power Electron Beams Through Small Apertures
Authors:
C. Tschalaer,
R. Alarcon,
S. Balascuta,
S. V. Benson,
W. Bertozzi,
J. R. Boyce,
R. Cowan,
D. Douglas,
P. Evtushenko,
P. Fisher,
E. Ihloff,
N. Kalantarians,
A. Kelleher,
R. Legg,
R. G. Milner,
G. R. Neil,
L. Ou,
B. Schmookler,
C. Tennant,
G. P. Williams,
S. Zhang,
.
Abstract:
Tests were performed to pass a 100 MeV, 430 kWatt c.w. electron beam from the energy-recovery linac at the Jefferson Laboratory's FEL facility through a set of small apertures in a 127 mm long aluminum block. Beam transmission losses of 3 p.p.m. through a 2 mm diameter aperture were maintained during a 7 hour continuous run.
Tests were performed to pass a 100 MeV, 430 kWatt c.w. electron beam from the energy-recovery linac at the Jefferson Laboratory's FEL facility through a set of small apertures in a 127 mm long aluminum block. Beam transmission losses of 3 p.p.m. through a 2 mm diameter aperture were maintained during a 7 hour continuous run.
△ Less
Submitted 31 May, 2013;
originally announced May 2013.
-
Measured Radiation and Background Levels During Transmission of Megawatt Electron Beams Through Millimeter Apertures
Authors:
R. Alarcon,
S. Balascuta,
S. V. Benson,
W. Bertozzi,
J. R. Boyce,
R. Cowan,
D. Douglas,
P. Evtushenko,
P. Fisher,
E. Ihloff,
N. Kalantarians,
A. Kelleher,
W. J. Kossler,
R. Legg,
E. Long,
R. G. Milner,
G. R. Neil,
L. Ou,
B. Schmookler,
C. Tennant,
C. Tschalaer,
G. P. Williams,
S. Zhang
Abstract:
We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery…
▽ More
We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation when the machine is tuned for 130 MeV operation.
△ Less
Submitted 30 May, 2013;
originally announced May 2013.
-
Transmission of Megawatt Relativistic Electron Beams Through Millimeter Apertures
Authors:
R. Alarcon,
S. Balascuta,
S. V. Benson,
W. Bertozzi,
J. R. Boyce,
R. Cowan,
D. Douglas,
P. Evtushenko,
P. Fisher,
E. Ihloff,
N. Kalantarians,
A. Kelleher,
R. Legg,
R. G. Milner,
G. R. Neil,
L. Ou,
B. Schmookler,
C. Tennant,
C. Tschalaer,
G. P. Williams,
S. Zhang
Abstract:
High power, relativistic electron beams from energy recovery linacs have great potential to realize new experimental paradigms for pioneering innovation in fundamental and applied research. A major design consideration for this new generation of experimental capabilities is the understanding of the halo associated with these bright, intense beams. In this Letter, we report on measurements performe…
▽ More
High power, relativistic electron beams from energy recovery linacs have great potential to realize new experimental paradigms for pioneering innovation in fundamental and applied research. A major design consideration for this new generation of experimental capabilities is the understanding of the halo associated with these bright, intense beams. In this Letter, we report on measurements performed using the 100 MeV, 430 kWatt CW electron beam from the energy recovery linac at the Jefferson Laboratory's Free Electron Laser facility as it traversed a set of small apertures in a 127 mm long aluminum block. Thermal measurements of the block together with neutron measurements near the beam-target interaction point yielded a consistent understanding of the beam losses. These were determined to be 3 ppm through a 2 mm diameter aperture and were maintained during a 7 hour continuous run.
△ Less
Submitted 1 May, 2013;
originally announced May 2013.
-
Background Rejection in the DMTPC Dark Matter Search Using Charge Signals
Authors:
J. P. Lopez,
D. Dujmic,
S. Ahlen,
J. B. R. Battat,
C. Deaconu,
P. Fisher,
S. Henderson,
A. Inglis,
A. Kaboth,
J. Monroe,
G. Sciolla,
H. Tomita,
H. Wellenstein,
R. Yamamoto
Abstract:
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing a low pressure gas TPC for detecting Weakly Interacting Massive Particle (WIMP)-nucleon interactions. Optical readout with CCD cameras allows for the detection of the daily modulation of the direction of the dark matter wind. In order to reach sensitivities required for WIMP detection, the detector needs to minimize backgr…
▽ More
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing a low pressure gas TPC for detecting Weakly Interacting Massive Particle (WIMP)-nucleon interactions. Optical readout with CCD cameras allows for the detection of the daily modulation of the direction of the dark matter wind. In order to reach sensitivities required for WIMP detection, the detector needs to minimize backgrounds from electron recoils. This paper demonstrates that a simplified CCD analysis achieves $7.3\times10^{-5}$ rejection of electron recoils while a charge analysis yields an electron rejection factor of $3.3\times10^{-4}$ for events with $^{241}$Am-equivalent ionization energy loss between 40 keV and 200 keV. A combined charge and CCD analysis yields a background-limited upper limit of $1.1\times10^{-5}$ (90% confidence level) for the rejection of $γ$ and electron events. Backgrounds from alpha decays from the field cage are eliminated by introducing a veto electrode that surrounds the sensitive region in the TPC. CCD-specific backgrounds are reduced more than two orders of magnitude when requiring a coincidence with the charge readout.
△ Less
Submitted 28 January, 2013; v1 submitted 23 January, 2013;
originally announced January 2013.
-
Background Rejection in the DMTPC Dark Matter Search Using Charge Signals
Authors:
J. P. Lopez,
S. Ahlen,
J. Battat,
T. Caldwell,
M. Chernicoff,
C. Deaconu,
D. Dujmic,
A. Dushkin,
W. Fedus,
P. Fisher,
F. Golub,
S. Henderson,
A. Inglis,
A. Kaboth,
G. Kohse,
L. Kirsch,
R. Lanza,
A. Lee,
J. Monroe,
H. Ouyang,
T. Sahin,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
H. Wellenstein
, et al. (3 additional authors not shown)
Abstract:
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the direction of the dark matter wind, while several charge readout channels allow for the measurement of additional recoil properties. In this article, we show that…
▽ More
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the direction of the dark matter wind, while several charge readout channels allow for the measurement of additional recoil properties. In this article, we show that the addition of the charge readout analysis to the CCD allows us too obtain a statistics-limited 90% C.L. upper limit on the $e^-$ rejection factor of $5.6\times10^{-6}$ for recoils with energies between 40 and 200 keV$_{\mathrm{ee}}$. In addition, requiring coincidence between charge signals and light in the CCD reduces CCD-specific backgrounds by more than two orders of magnitude.
△ Less
Submitted 15 September, 2011;
originally announced September 2011.
-
Expression of Interest for a Novel Search for CP Violation in the Neutrino Sector: DAEdALUS
Authors:
J. Alonso,
F. T. Avignone,
W. A. Barletta,
R. Barlow,
H. T. Baumgartner,
A. Bernstein,
E. Blucher,
L. Bugel,
L. Calabretta,
L. Camilleri,
R. Carr,
J. M. Conrad,
S. A. Dazeley,
Z. Djurcic,
A. de Gouvea,
P. H. Fisher,
C. M. Ignarra,
B. J. P. Jones,
C. L. Jones,
G. Karagiorgi,
T. Katori,
S. E. Kopp,
R. C. Lanza,
W. A. Loinaz,
P. McIntyre
, et al. (20 additional authors not shown)
Abstract:
DAEdALUS, a Decay-At-rest Experiment for delta_CP studies At the Laboratory for Underground Science, provides a new approach to the search for CP violation in the neutrino sector. The design utilizes low-cost, high-power proton accelerators under development for commercial uses. These provide neutrino beams with energy up to 52 MeV from pion and muon decay-at-rest. The experiment searches for anin…
▽ More
DAEdALUS, a Decay-At-rest Experiment for delta_CP studies At the Laboratory for Underground Science, provides a new approach to the search for CP violation in the neutrino sector. The design utilizes low-cost, high-power proton accelerators under development for commercial uses. These provide neutrino beams with energy up to 52 MeV from pion and muon decay-at-rest. The experiment searches for aninu_mu to antinu_e at short baselines corresponding to the atmospheric Delta m^2 region. The antinu_e will be detected, via inverse beta decay, in the 300 kton fiducial-volume Gd-doped water Cherenkov neutrino detector proposed for the Deep Underground Science and Engineering Laboratory (DUSEL). DAEdALUS opens new opportunities for DUSEL. It provides a high-statistics, low-background alternative for CP violation searches which matches the capability of the conventional long-baseline neutrino experiment, LBNE. Because of the complementary designs, when DAEdALUS antineutrino data are combined with LBNE neutrino data, the sensitivity of the CP-violation search improves beyond any present proposals, including the proposal for Project X. Also, the availability of an on-site neutrino beam opens opportunities for additional physics, both for the presently planned DUSEL detectors and for new experiments at a future 300 ft campus.
△ Less
Submitted 1 June, 2010;
originally announced June 2010.
-
A Background-Free Direction-Sensitive Neutron Detector2 A Background-Free Direction-Sensitive Neutron Detector
Authors:
Alvaro Roccaro,
H. Tomita,
S. Ahlen,
D. Avery,
A. Inglis,
J. Battat,
D. Dujmic,
P. Fisher,
S. Henderson,
A. Kaboth,
G. Kohse,
R. Lanza,
J. Monroe,
G. Sciolla,
N. Skvorodnev,
H. Wellenstein,
R. Yamamoto
Abstract:
We show data from a new type of detector that can be used to determine neutron flux, energy distribution, and direction of neutron motion for both fast and thermal neutrons. Many neutron detectors are plagued by large backgrounds from x-rays and gamma rays, and most current neutron detectors lack single-event energy sensitivity or any information on neutron directionality. Even the best detector…
▽ More
We show data from a new type of detector that can be used to determine neutron flux, energy distribution, and direction of neutron motion for both fast and thermal neutrons. Many neutron detectors are plagued by large backgrounds from x-rays and gamma rays, and most current neutron detectors lack single-event energy sensitivity or any information on neutron directionality. Even the best detectors are limited by cosmic ray neutron backgrounds. All applications (neutron scattering and radiography, measurements of solar and cosmic ray neutron flux, measurements of neutron interaction cross sections, monitoring of neutrons at nuclear facilities, oil exploration, and searches for fissile weapons of mass destruction) will benefit from the improved neutron detection sensitivity and improved measurements of neutron properties made possible by this detector. The detector is free of backgrounds from x-rays, gamma rays, beta particles, relativistic singely charged particles and cosmic ray neutrons. It is sensitive to thermal neutrons, fission neutrons, and high energy neutrons, with detection features distinctive for each energy range. It is capable of determining the location of a source of fission neutrons based on characteristics of elastic scattering of neutrons by helium nuclei. The detector we have constructed could identify one gram of reactor grade plutonium, one meter away, with less than one minute of observation time.
△ Less
Submitted 21 June, 2009;
originally announced June 2009.
-
Transport properties of electrons in CF4
Authors:
T. Caldwell,
A. Roccaro,
T. Sahin,
H. Yegoryan,
D. Dujmic,
S. Ahlen,
J. Battat,
P. Fisher,
S. Henderson,
A. Kaboth,
G. Kohse,
R. Lanza,
J. Lopez,
J. Monroe,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
R. Vanderspek,
H. Wellenstein,
R. Yamamoto
Abstract:
Carbon-tetrafluoride (CF4) is used as a counting gas in particle detectors, but some of its properties that are of interest for large time-projection chambers are not well known. We measure the mean energy, which is proportional to the diffusion coefficent, and the attentuation coefficient of electron propagation in CF4 gas using a 10-liter dark matter detector prototype of the DMTPC project.
Carbon-tetrafluoride (CF4) is used as a counting gas in particle detectors, but some of its properties that are of interest for large time-projection chambers are not well known. We measure the mean energy, which is proportional to the diffusion coefficent, and the attentuation coefficient of electron propagation in CF4 gas using a 10-liter dark matter detector prototype of the DMTPC project.
△ Less
Submitted 15 May, 2009;
originally announced May 2009.
-
DMTPC-10L: Direction-Sensitive Dark Matter Detector Prototype
Authors:
D. Dujmic,
P. Fisher,
R. Lanza,
J. Lopez,
A. Kaboth,
G. Kohse,
J. Monroe,
R. Vanderspek,
G. Sciolla,
R. Yamamoto,
S. Ahlen,
K. Otis,
A. Roccaro,
H. Tomita,
N. Skvorodnev,
H. Wellenstein
Abstract:
The known direction of motion of dark matter particles relative to the Earth may be a key for their unambiguous identification even in the presence of backgrounds. We describe a prototype detector that is able to reconstruct direction vectors of weakly interacting massive particles that may the dominant constituent of the dark matter in our galaxy. The detector uses a low-density gas (CF4) in a…
▽ More
The known direction of motion of dark matter particles relative to the Earth may be a key for their unambiguous identification even in the presence of backgrounds. We describe a prototype detector that is able to reconstruct direction vectors of weakly interacting massive particles that may the dominant constituent of the dark matter in our galaxy. The detector uses a low-density gas (CF4) in a 10liter time-projection chamber with mesh-based electrodes and optical and charge readout. Initial results confirm good performance in the reconstruction of direction angle and sense ('head-tail') for low-momentum nuclear recoils.
△ Less
Submitted 15 October, 2008;
originally announced October 2008.
-
A Measurement of Photon Production in Electron Avalanches in CF4
Authors:
A. Kaboth,
J. Monroe,
S. Ahlen,
D. Dujmic,
S. Henderson,
G. Kohse,
R. Lanza,
M. Lewandowska,
A. Roccaro,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
R. Vanderspek,
H. Wellenstein,
R. Yamamoto,
P. Fisher
Abstract:
This paper presents a measurement of the ratio of photon to electron production and the scintillation spectrum in a popular gas for time pro jection chambers, carbon tetrafluoride (CF4), over the range of 200 to 800 nm; the ratio is measured to be 0.34+/-0.04. This result is of particular importance for a new generation of dark matter time projection chambers with directional sensitivity which u…
▽ More
This paper presents a measurement of the ratio of photon to electron production and the scintillation spectrum in a popular gas for time pro jection chambers, carbon tetrafluoride (CF4), over the range of 200 to 800 nm; the ratio is measured to be 0.34+/-0.04. This result is of particular importance for a new generation of dark matter time projection chambers with directional sensitivity which use CF4 as a fill gas.
△ Less
Submitted 14 March, 2008;
originally announced March 2008.
-
Observation of the 'head-tail' effect in nuclear recoils of low-energy neutrons
Authors:
D. Dujmic,
H. Tomita,
M. Lewandowska,
S. Ahlen,
P. Fisher,
S. Henderson,
A. Kaboth,
G. Kohse,
R. Lanza,
J. Monroe,
A. Roccaro,
G. Sciolla,
N. Skvorodnev,
R. Vanderspek,
H. Wellenstein,
R. Yamamoto
Abstract:
Directional detection of dark matter can provide unambiguous observation of dark matter interactions even in the presence of background. This article presents an experimental method to measure the direction tag ("head-tail") of the dark matter wind by detecting the scintillation light created by the elastic nuclear recoils in the scattering of dark matter particles with the detector material. Th…
▽ More
Directional detection of dark matter can provide unambiguous observation of dark matter interactions even in the presence of background. This article presents an experimental method to measure the direction tag ("head-tail") of the dark matter wind by detecting the scintillation light created by the elastic nuclear recoils in the scattering of dark matter particles with the detector material. The technique is demonstrated by tagging the direction of the nuclear recoils created in the scattering of low-energy neutrons with CF4 in a low-pressure time-projection chamber that is developed by the DMTPC collaboration. The measurement of the decreasing ionization rate along the recoil trajectory provides the direction tag of the incoming neutrons, and proves that the "head-tail" effect can be observed.
△ Less
Submitted 9 October, 2007; v1 submitted 17 August, 2007;
originally announced August 2007.