-
A Demonstration of Slowed Electron ${\bf E} \times {\bf B}$ Drift for PTOLEMY
Authors:
M. Farino,
A. Tan,
A. Apponi,
M. Betti,
M. Borghesi,
A. Casale,
O. Castellano,
G. Cavoto,
L. Cecchini,
E. Celasco,
W. Chung,
A. G. Cocco,
A. Colijn,
B. Corcione,
N. D'Ambrosio,
N. de Groot,
S. el Morabit,
A. Esposito,
M. Faverzani,
A. D. Ferella,
E. Ferri,
L. Ficcadenti,
S. Gamba,
S. Gariazzo,
H. Garrone
, et al. (36 additional authors not shown)
Abstract:
The novel transverse electromagnetic filtering system proposed by the PTOLEMY collaboration necessitates the precise control of $β$-decay electron motion via ${\bf E} \times {\bf B}$ drift. In particular, drift speed must be slowed substantially to contain electrons within the radio-frequency antenna region and accurately tune voltage potentials within the filter. This paper presents the experimen…
▽ More
The novel transverse electromagnetic filtering system proposed by the PTOLEMY collaboration necessitates the precise control of $β$-decay electron motion via ${\bf E} \times {\bf B}$ drift. In particular, drift speed must be slowed substantially to contain electrons within the radio-frequency antenna region and accurately tune voltage potentials within the filter. This paper presents the experimental design to vary ${\bf E} \times {\bf B}$ drift speed of carbon-14 $β$-decay electrons using a custom electrode field cage situated between the pole faces of an electromagnet. Matching our results with high-fidelity simulation, we deduce a capacity to increase particle time of flight by a factor of 5 in the field cage's slow drift region. Limited only by the dimensions of our system, we assert drift speed can be arbitrarily slowed to meet the needs of PTOLEMY's future detector.
△ Less
Submitted 28 March, 2025; v1 submitted 13 March, 2025;
originally announced March 2025.
-
Implementation and Optimization of the PTOLEMY Transverse Drift Electromagnetic Filter
Authors:
A. Apponi,
M. G. Betti,
M. Borghesi,
A. Boscá,
F. Calle,
N. Canci,
G. Cavoto,
C. Chang,
W. Chung,
A. G. Cocco,
A. P. Colijn,
N. D'Ambrosio,
N. de Groot,
M. Faverzani,
A. Ferella,
E. Ferri,
L. Ficcadenti,
P. Garcia-Abia,
G. Garcia Gomez-Tejedor,
S. Gariazzo,
F. Gatti,
C. Gentile,
A. Giachero,
Y. Hochberg,
Y. Kahn
, et al. (31 additional authors not shown)
Abstract:
The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the s…
▽ More
The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to <10 eV (<1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratary (LNGS) in Italy.
△ Less
Submitted 24 January, 2022; v1 submitted 23 August, 2021;
originally announced August 2021.
-
EuPRAXIA@SPARC_LAB Design study towards a compact FEL facility at LNF
Authors:
M. Ferrario,
D. Alesini,
M. P. Anania,
M. Artioli,
A. Bacci,
S. Bartocci,
R. Bedogni,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
F. Brandi,
E. Brentegani,
F. Broggi,
B. Buonomo,
P. L. Campana,
G. Campogiani,
C. Cannaos,
S. Cantarella,
F. Cardelli,
M. Carpanese,
M. Castellano,
G. Castorina,
N. Catalan Lasheras,
E. Chiadroni,
A. Cianchi
, et al. (95 additional authors not shown)
Abstract:
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in…
▽ More
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in synergy with the EuPRAXIA design study. In this paper we report about the recent progresses in the on going design study of the new facility.
△ Less
Submitted 26 January, 2018;
originally announced January 2018.
-
Wake fields effects in dielectric capillary
Authors:
A. Biagioni,
M. P. Anania,
M. Bellaveglia,
E. Brentegani,
G. Castorina,
E. Chiadroni,
A. Cianchi,
D. Di Giovenale,
G. Di Pirro,
H. Fares,
L. Ficcadenti,
F. Filippi,
M. Ferrario,
A. Mostacci,
R. Pompili,
J. Scifo,
B. Spataro,
C. Vaccarezza,
F. Villa,
A. Zigler
Abstract:
Plasma wake-field acceleration experiments are performed at the SPARC LAB test facility by using a gas-filled capillary plasma source composed of a dielectric capillary. The electron can reach GeV energy in a few centimeters, with an accelerating gradient orders of magnitude larger than provided by conventional techniques. In this acceleration scheme, wake fields produced by passing electron beams…
▽ More
Plasma wake-field acceleration experiments are performed at the SPARC LAB test facility by using a gas-filled capillary plasma source composed of a dielectric capillary. The electron can reach GeV energy in a few centimeters, with an accelerating gradient orders of magnitude larger than provided by conventional techniques. In this acceleration scheme, wake fields produced by passing electron beams through dielectric structures can determine a strong beam instability that represents an important hurdle towards the capability to focus high-current electron beams in the transverse plane. For these reasons, the estimation of the transverse wakefield amplitudes assumes a fundamental role in the implementation of the plasma wake-field acceleration. In this work, it presented a study to investigate which parameters affect the wake-field formation inside a cylindrical dielectric structure, both the capillary dimensions and the beam parameters, and it is introduced a quantitative evaluation of the longitudinal and transverse electric fields.
△ Less
Submitted 12 January, 2018;
originally announced January 2018.
-
Technical Design Report EuroGammaS proposal for the ELI-NP Gamma beam System
Authors:
O. Adriani,
S. Albergo,
D. Alesini,
M. Anania,
D. Angal-Kalinin,
P. Antici,
A. Bacci,
R. Bedogni,
M. Bellaveglia,
C. Biscari,
N. Bliss,
R. Boni,
M. Boscolo,
F. Broggi,
P. Cardarelli,
K. Cassou,
M. Castellano,
L. Catani,
I. Chaikovska,
E. Chiadroni,
R. Chiche,
A. Cianchi,
J. Clarke,
A. Clozza,
M. Coppola
, et al. (84 additional authors not shown)
Abstract:
The machine described in this document is an advanced Source of up to 20 MeV Gamma Rays based on Compton back-scattering, i.e. collision of an intense high power laser beam and a high brightness electron beam with maximum kinetic energy of about 720 MeV. Fully equipped with collimation and characterization systems, in order to generate, form and fully measure the physical characteristics of the pr…
▽ More
The machine described in this document is an advanced Source of up to 20 MeV Gamma Rays based on Compton back-scattering, i.e. collision of an intense high power laser beam and a high brightness electron beam with maximum kinetic energy of about 720 MeV. Fully equipped with collimation and characterization systems, in order to generate, form and fully measure the physical characteristics of the produced Gamma Ray beam. The quality, i.e. phase space density, of the two colliding beams will be such that the emitted Gamma ray beam is characterized by energy tunability, spectral density, bandwidth, polarization, divergence and brilliance compatible with the requested performances of the ELI-NP user facility, to be built in Romania as the Nuclear Physics oriented Pillar of the European Extreme Light Infrastructure. This document illustrates the Technical Design finally produced by the EuroGammaS Collaboration, after a thorough investigation of the machine expected performances within the constraints imposed by the ELI-NP tender for the Gamma Beam System (ELI-NP-GBS), in terms of available budget, deadlines for machine completion and performance achievement, compatibility with lay-out and characteristics of the planned civil engineering.
△ Less
Submitted 14 July, 2014;
originally announced July 2014.