-
A High-Precision, Fast, Robust, and Cost-Effective Muon Detector Concept for the FCC-ee
Authors:
F. Anulli,
H. Beauchemin,
C. Bini,
A. Bross,
M. Corradi,
T. Dai,
D. Denisov,
E. C. Dukes,
C. Ferretti,
P. Fleischmann,
M. Franklin,
J. Freeman,
J. Ge,
L. Guan,
Y. Guo,
C. Herwig,
S. -C. Hsu,
J. Huth,
D. Levin,
C. Li,
H. -C. Lin,
H. Lubatti,
C. Luci,
V. Martinez Outschoorn,
K. Nelson
, et al. (15 additional authors not shown)
Abstract:
We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements. The drift tubes deliver two-dimensional position measurements perpendicular to the tubes with a resolution around 100~$μ$m. Meanwhile, the scintillator strips, re…
▽ More
We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements. The drift tubes deliver two-dimensional position measurements perpendicular to the tubes with a resolution around 100~$μ$m. Meanwhile, the scintillator strips, read out with the wavelength-shifting fibers and silicon photomultipliers, provide fast timing information with a precision of 200~ps or better and measure the third coordinate along the tubes with a resolution of about 1~mm.
△ Less
Submitted 14 April, 2025;
originally announced April 2025.
-
A Prototype Scintillator Real-Time Beam Monitor for Ultra-high Dose Rate Radiotherapy
Authors:
Daniel S. Levin,
Peter S. Friedman,
Claudio Ferretti,
Nicholas Ristow,
Monica Tecchio,
Dale W. Litzenberg,
Vladimir Bashkirov,
Reinhard Schulte
Abstract:
FLASH Radiotherapy (RT) is a potentially new cancer radiotherapy technique where an entire therapeutic dose is delivered in about 0.1 s and at ~1000 times higher dose rate than in conventional RT. For clinical trials to be conducted safely, precise and fast beam monitoring that can generate an out-of-tolerance beam interrupt is required. A FLASH Beam Scintillator Monitor (FBSM) is being developed…
▽ More
FLASH Radiotherapy (RT) is a potentially new cancer radiotherapy technique where an entire therapeutic dose is delivered in about 0.1 s and at ~1000 times higher dose rate than in conventional RT. For clinical trials to be conducted safely, precise and fast beam monitoring that can generate an out-of-tolerance beam interrupt is required. A FLASH Beam Scintillator Monitor (FBSM) is being developed based in part on a novel proprietary inorganic hybrid scintillator material. The FBSM provides large area coverage, low mass profile, linear response over a broad dynamic range, radiation tolerance, and real-time analysis IEC-compliant fast beam-interrupt signal. This paper includes the design concept and test results from a prototype device in radiation beams that include heavy ions, FLASH level dose per pulse electron beams, anda hospital radiotherapy clinic with electron beams. Results include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. The scintillator showed a small -0.02%/kGy signal decrease after a 212 kGy cumulative dose resulting from continuous exposure for 15 minutes at a FLASH compatible dose rate of 234 Gy/s. These tests established the linear response of the FBSM with respect to dose per pulse. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile. At 20 kfps or 50 microsec/frame, the real-time FPGA based computation and analysis of beam position, beam shape, and beam dose takes < 1 microsec.
△ Less
Submitted 8 March, 2024; v1 submitted 24 May, 2023;
originally announced May 2023.
-
Construction of Precision sMDT Detector for ATLAS Muon Spectrometer Upgrade
Authors:
D. Amidei,
N. Anderson,
A. Chen,
E. Carpenter,
L. Cooperrider,
T. Dai,
E. Diehl,
C. Ferretti,
Y. Guo,
J. Li,
X. Meng,
K. Nelson,
V. Pillsbury,
E. Salzer,
T. Schwarz,
L. Simpson,
Z. Wang,
C. Weaverdyck,
C. Wei,
Z. Yang,
M. Yuan,
B. Zhou,
J. Zhu
Abstract:
This paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 microns. The positions of the platforms f…
▽ More
This paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 microns. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 +- 7 microns with an average detection efficiency above 99 %. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.
△ Less
Submitted 1 November, 2022;
originally announced November 2022.
-
Construction and testing of sMDT tubes at the University of Michigan for the ATLAS Muon Spectrometer upgrade
Authors:
C. Wei,
A. Chen,
D. Amidei,
N. Anderson,
E. Carpenter,
L. Cooperrider,
T. Dai,
E. Diehl,
C. Ferretti,
J. Li,
P. Lugato,
J. Minnella,
S. Moskaitis,
K. Nelson,
V. Pillsbury,
E. Salzer,
L. Simpson,
Z. C. Wang,
Z. R. Wang,
C. Weaverdyck,
Z. Yang,
B. Zhou
Abstract:
This paper reports on the design and construction of infrastructure and test stations for small-diameter monitored drift tube (sMDT) assembly and testing at the University of Michigan (UM) to prepare for the ATLAS Muon Spectrometer upgrade for the high-luminosity program of the Large Hadron Collider. Procedures of the tube assembly and quality assurance and control (QA/QC) tests are described in d…
▽ More
This paper reports on the design and construction of infrastructure and test stations for small-diameter monitored drift tube (sMDT) assembly and testing at the University of Michigan (UM) to prepare for the ATLAS Muon Spectrometer upgrade for the high-luminosity program of the Large Hadron Collider. Procedures of the tube assembly and quality assurance and control (QA/QC) tests are described in detail. More than 99% of the tubes meet the tube QA/QC specifications based on 2100 tubes built at UM. The UM test stations are also used for QA/QC testing on the tubes constructed at Michigan State University. These tubes are being used to construct the sMDT chambers which will replace the current MDT chambers of the barrel inner station of the Muon Spectrometer.
△ Less
Submitted 8 September, 2022;
originally announced September 2022.
-
A High Performance Scintillator Ion Beam Monitor
Authors:
Daniel S Levin,
Peter S. Friedman,
Tom Ginter,
Claudio Ferretti,
Alexander Kaipainen,
Nicholas Ristow
Abstract:
A high-performance Scintillator Ion Beam Monitor (SIBM) provides diagnostics across a range of isotopes, energies, and intensities employing a machine-vision camera with two novel scintillator targets movable into/out of the beam without breaking vacuum. Scintillators are: 1) a semicrystalline polymer material (PM) film, 1-200 microns thick; 2) A 100-400 micron thick opaque wafer consisting of a h…
▽ More
A high-performance Scintillator Ion Beam Monitor (SIBM) provides diagnostics across a range of isotopes, energies, and intensities employing a machine-vision camera with two novel scintillator targets movable into/out of the beam without breaking vacuum. Scintillators are: 1) a semicrystalline polymer material (PM) film, 1-200 microns thick; 2) A 100-400 micron thick opaque wafer consisting of a hybrid of inorganic-polymer (HM) plastic matrix. The SIBM was demonstrated at the Facility of Rare Isotope Beams (FRIB, East Lansing, MI) real-time beam profile and rate analysis spanning more than five orders of magnitude including visualization of single ion signals. It may replace FRIB reference detectors: Faraday cup, silicon strips and a micro-channel plate.
△ Less
Submitted 31 August, 2022;
originally announced August 2022.
-
A Sonification of the zCOSMOS Galaxy Dataset
Authors:
S. Bardelli,
Claudia Ferretti,
Luca Andrea Ludovico,
Giorgio Presti,
Maurizio Rinaldi
Abstract:
Sonification is the transformation of data into acoustic signals, achievable through different techniques. Sonification can be defined as a way to represent data values and relations as perceivable sounds, aiming at facilitating their communication and interpretation. Like data visualization provides meaning via images, sonification conveys meaning via sound. Sonification approaches are useful in…
▽ More
Sonification is the transformation of data into acoustic signals, achievable through different techniques. Sonification can be defined as a way to represent data values and relations as perceivable sounds, aiming at facilitating their communication and interpretation. Like data visualization provides meaning via images, sonification conveys meaning via sound. Sonification approaches are useful in a number of scenario. A first case is the possibility to receive information while keeping other sensory channels free, like in medical environment, in driving experience, etc. Another scenario addresses an easier recognition of patterns when data present high dimensionality and cardinality. Finally, sonification can be applied to presentation and dissemination initiatives, also with artistic goals. The zCOSMOS dataset contains detailed data about almost 20000 galaxies, describing the evolution of a relatively small portion of the universe in the last 10 million years in terms of galaxy mass, absolute luminosity, redshift, distance, age, and star formation rate. The present paper proposes a sonification for the mentioned dataset, with the following goals: i) providing a general description of the dataset, accessible via sound, which could also make unnoticed patterns emerge; ii) realizing an artistic but scientifically accurate sonic portrait of a portion of the universe, thus filling the gap between art and science in the context of scientific dissemination and so-called "edutainment"; iii) adding value to the dataset, since also scientific data and achievements must be considered as a cultural heritage that needs to be preserved and enhanced. Both scientific and technological aspects of the sonification are addressed.
△ Less
Submitted 11 February, 2022;
originally announced February 2022.
-
Operation and performance of microhexcavity pixel detector in gas discharge and avalanche mode
Authors:
A. Mulski,
Y. Benhammou,
J. W. Chapman,
A. Das,
E. Etzion,
C. Ferretti,
P. S. Friedman,
R. P. Johnson,
D. S. Levin,
N. Kamp,
H. Ochoa,
M. Raviv-Moshe,
N. Ristow
Abstract:
The Microhexcavity Panel ( muHex) is a novel gaseous micropattern particle detector comprised of a dense array of close-packed hexagonal pixels, each operating as an independent detection unit for ionizing radiation. It is a second generation detector derived from plasma panel detectors and microcavity detectors. The muHex is under development to be deployed as a scalable, fast timing (ns) and her…
▽ More
The Microhexcavity Panel ( muHex) is a novel gaseous micropattern particle detector comprised of a dense array of close-packed hexagonal pixels, each operating as an independent detection unit for ionizing radiation. It is a second generation detector derived from plasma panel detectors and microcavity detectors. The muHex is under development to be deployed as a scalable, fast timing (ns) and hermetically sealed gaseous tracking detector with high rate ( > 100 KHz/cm^2 ) capability. The devices reported here were fabricated as 16 x 16 pixel arrays of 2 mm edge-to-edge, 1 mm deep hexagonal cells embedded in a thin, 1.4 mm glass-ceramic wafer. Cell walls are metalized cathodes, connected to high voltage bus lines through conductive vias. Anodes are small, 457 micron diameter metal discs screen printed on the upper substrate. The detectors are filled with an operating gas to near 1 atm and then closed with a shut-off valve. They have been operated in both avalanche mode and gas discharge devices, producing mV to volt level signals with about 1 to 3 ns rise times. Operation in discharge mode is enabled by high impedance quench resistors on the high voltage bus at each pixel site. Results indicate that each individual pixel behaves as an isolated detection unit with high single pixel intrinsic efficiency to both beta's from radioactive sources and to cosmic ray muons. Continuous avalanche mode operation over several days at hit rates over 300 KHz/cm^2 with no gas flow have been observed. Measurements of pixel isolation, timing response, efficiency, hit rate and rate stability are reported.
△ Less
Submitted 24 October, 2018;
originally announced October 2018.
-
Performance of a First Microhexcavity Plasma Panel Detector with Muons
Authors:
Alexis Mulski,
Yan Benhamou,
Erez Etzion,
Claudio Ferretti,
Peter S. Friedman,
Daniel S. Levin,
Meny Raviv Moshe,
David Reikher,
Nicholas Ristow
Abstract:
The microhexcavity plasma panel detector is a type of gaseous particle detector consisting of a close-packed array of millimeter-size hexagonal cells. The cells are biased to operate in Geiger mode where each cell functions as an independent detection unit. The response of the detector to ionizing radiation was investigated using low-energy radioactive $ β$ sources and cosmic ray muons. Efficiency…
▽ More
The microhexcavity plasma panel detector is a type of gaseous particle detector consisting of a close-packed array of millimeter-size hexagonal cells. The cells are biased to operate in Geiger mode where each cell functions as an independent detection unit. The response of the detector to ionizing radiation was investigated using low-energy radioactive $ β$ sources and cosmic ray muons. Efficiency measurements were conducted with cosmic ray muons in conjunction with a scintillator hodoscope. The rate response and signals obtained from the microhexcavity detector filled with Penning gas mixture at atmospheric pressure are herein described. The relative pixel efficiency, after allowing for ion-pair formation in the gas volume, is 96.8 $ \pm $ 4.4$ \% $ for operation of the detector above an applied high voltage of 1000 V.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
Microhexcavity Plasma Panel Detectors
Authors:
Alexis Mulski,
Daniel S. Levin,
Yan Benhamou,
John W. Chapman,
Achintya Das,
Erez Etzion,
Claudio Ferretti,
Peter S. Friedman,
Meny Raviv-Moshe,
David Reikher,
Nicholas Ristow
Abstract:
Plasma panel detectors are a variant of micropattern detectors that are sensitive to ionizing radiation. They are motivated by the design and operation of plasma display panels. The detectors consist of arrays of electrically and optically isolated pixels defined by metallized cavities embedded in a dielectric substrate. These are hermetically sealed gaseous detectors that use exclusively non-hydr…
▽ More
Plasma panel detectors are a variant of micropattern detectors that are sensitive to ionizing radiation. They are motivated by the design and operation of plasma display panels. The detectors consist of arrays of electrically and optically isolated pixels defined by metallized cavities embedded in a dielectric substrate. These are hermetically sealed gaseous detectors that use exclusively non-hydrocarbon gas mixtures. The newest variant of these closed-architecture detectors is known as the Microhexcavity plasma panel detector ($μ$Hex) consisting of 2 mm wide, regular close-packed hexagonal pixels each with a circular thick-film anode. The fabrication, staging, and operation of these detectors is described. Initial tests with the $μ$Hex detectors operated in Geiger mode yield Volt-level signals in the presence of ionizing radiation. The spontaneous discharge rate in the absence of a source is roughly 3-4 orders of magnitude lower compared to the rates measured using low energy betas.
△ Less
Submitted 18 September, 2017; v1 submitted 13 September, 2017;
originally announced September 2017.
-
Upgrades of the ATLAS Muon Spectrometer with sMDT Chambers
Authors:
C. Ferretti,
H. Kroha
Abstract:
With half the drift-tube diameter of the Monitored Drift Tube (MDT) chambers of the ATLAS muon spectrometer and otherwise unchanged operating parameters, small-diameter Muon Drift Tube (sMDT) chambers provide an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit. The chamber assembly time has been reduced by a factor of seven to one wor…
▽ More
With half the drift-tube diameter of the Monitored Drift Tube (MDT) chambers of the ATLAS muon spectrometer and otherwise unchanged operating parameters, small-diameter Muon Drift Tube (sMDT) chambers provide an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit. The chamber assembly time has been reduced by a factor of seven to one working day and the sense wire positioning accuracy improved by a factor of two to better than ten microns. Two sMDT chambers have been installed in ATLAS in 2014 to improve the momentum resolution in the barrel part of the spectrometer. The construction of an additional twelve chambers covering the feet regions of the ATLAS detector has started. It will be followed by the replacement of the MDT chambers at the ends of the barrel inner layer by sMDTs improving the Performance at the high expected background rates and providing space for additional RPC trigger chambers.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
First results with a microcavity plasma panel detector
Authors:
R. Ball,
M. Ben-Moshe,
Y. Benhammou,
R. Bensimon,
J. W. Chapman,
M. Davies,
E. Etzion,
C. Ferretti,
P. S. Friedman,
D. S. Levin,
Y. Silver,
R. L. Varner,
C. Weaverdyck,
B. Zhou
Abstract:
A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles fro…
▽ More
A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles from a radioactive source, a maximum pixel efficiency of greater than 95% is calculated, for operation of the detector over a 100V wide span of high voltages (HV). Over this same HV range, the background rate per pixel was measured to be 3 to 4 orders of magnitude lower than the rate with the cell illuminated by the beta source. Pixel-to-pixel count rate uniformity is within 3% and stable within 3% for many days. The time resolution is 2.4 ns, and a very low cell-to-cell crosstalk has been measured between cells separated by 2 mm.
△ Less
Submitted 3 December, 2014; v1 submitted 24 July, 2014;
originally announced July 2014.
-
Development of a plasma panel radiation detector
Authors:
R. Ball,
J. R. Beene,
M. Ben-Moshe,
Y. Benhammou,
R. Bensimon,
J. W. Chapman,
E. Etzion,
C. Ferretti,
P. S. Friedman,
D. S. Levin,
Y. Silver,
R. L. Varner,
C. Weaverdyck,
R. Wetzel,
B. Zhou,
T. Anderson,
K. McKinny,
E. H. Bentefour
Abstract:
This article reports on the development and experimental results of commercial plasma display panels adapted for their potential use as micropattern gas radiation detectors. The plasma panel sensors (PPS) design an materials include glass substrates, metal electrodes and inert gas mixtures which provide a physically robust, hermetically-sealed device. Plasma display panels used as detectors were t…
▽ More
This article reports on the development and experimental results of commercial plasma display panels adapted for their potential use as micropattern gas radiation detectors. The plasma panel sensors (PPS) design an materials include glass substrates, metal electrodes and inert gas mixtures which provide a physically robust, hermetically-sealed device. Plasma display panels used as detectors were tested with cosmic ray muons, beta rays and gamma rays, protons and thermal neutrons. The results demonstrated rise times and time resolution of a few nanoseconds, as well as sub-millimeter spatial resolution compatible with the pixel pitch.
△ Less
Submitted 14 June, 2014; v1 submitted 13 March, 2014;
originally announced March 2014.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier
Authors:
M. Demarteau,
R. Lipton,
H. Nicholson,
I. Shipsey,
D. Akerib,
A. Albayrak-Yetkin,
J. Alexander,
J. Anderson,
M. Artuso,
D. Asner,
R. Ball,
M. Battaglia,
C. Bebek,
J. Beene,
Y. Benhammou,
E. Bentefour,
M. Bergevin,
A. Bernstein,
B. Bilki,
E. Blucher,
G. Bolla,
D. Bortoletto,
N. Bowden,
G. Brooijmans,
K. Byrum
, et al. (189 additional authors not shown)
Abstract:
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss…
▽ More
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
Plasma panel-based radiation detectors
Authors:
Peter Friedman,
Robert Ball,
James Beene,
Yan Benhammou,
Meny Ben-Moshe,
Hassan Bentefour,
J. W. Chapman,
Erez Etzion,
Claudio Ferretti,
Daniel Levin,
Yiftah Silver,
Robert Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels. It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in plasma display panels, it uses nonreactive, intrinsically radiation-hard materials such as glass substrates…
▽ More
The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels. It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in plasma display panels, it uses nonreactive, intrinsically radiation-hard materials such as glass substrates, refractory metal electrodes, and mostly inert gas mixtures. We are developing these devices primarily as thin, low-mass detectors with gas gaps from a few hundred microns to a few millimeters. The PPS is a high gain, inherently digital device with the potential for fast response times, fine position resolution (<50-mm RMS) and low cost. In this paper, we report on prototype PPS experimental results in detecting betas, protons, and cosmic muons, and we extrapolate on the PPS potential for applications including the detection of alphas, heavy ions at low-to-medium energy, thermal neutrons, and X-rays.
△ Less
Submitted 10 May, 2013;
originally announced May 2013.
-
Plasma Panel Sensors for Particle and Beam Detection
Authors:
Peter S. Friedman,
Robert Ball,
James R. Beene,
Yan Benhammou,
E. H. Bentefour,
J. W. Chapman,
Erez Etzion,
Claudio Ferretti,
Nir Guttman,
Daniel S. Levin,
Meny Ben-Moshe,
Yiftah Silver,
Robert L. Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
The plasma panel sensor (PPS) is an inherently digital, high gain, novel variant of micropattern gas detectors inspired by many operational and fabrication principles common to plasma display panels (PDPs). The PPS is comprised of a dense array of small, plasma discharge, gas cells within a hermetically-sealed glass panel, and is assembled from non-reactive, intrinsically radiation-hard materials…
▽ More
The plasma panel sensor (PPS) is an inherently digital, high gain, novel variant of micropattern gas detectors inspired by many operational and fabrication principles common to plasma display panels (PDPs). The PPS is comprised of a dense array of small, plasma discharge, gas cells within a hermetically-sealed glass panel, and is assembled from non-reactive, intrinsically radiation-hard materials such as glass substrates, metal electrodes and mostly inert gas mixtures. We are developing the technology to fabricate these devices with very low mass and small thickness, using gas gaps of at least a few hundred micrometers. Our tests with these devices demonstrate a spatial resolution of about 1 mm. We intend to make PPS devices with much smaller cells and the potential for much finer position resolutions. Our PPS tests also show response times of several nanoseconds. We report here our results in detecting betas, cosmic-ray muons, and our first proton beam tests.
△ Less
Submitted 22 November, 2012;
originally announced November 2012.
-
Studies on fast triggering and high precision tracking with Resistive Plate Chambers
Authors:
G. Aielli,
B. Bilki,
R. Ball,
J. W. Chapman,
R. Cardarelli,
T. Dai,
E. Diehl,
J. Dubbert,
C. Ferretti,
H. Feng,
K. Francis,
L. Guan,
L. Han,
S. Hou,
D. Levin,
B. Li,
L. Liu,
L. Paolozzi,
J. Repond,
J. Roloff,
R. Santonico,
H. Y. Song,
X. L. Wang,
Y. Wu,
L. Xia
, et al. (5 additional authors not shown)
Abstract:
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores simultaneously precision tracking and triggering…
▽ More
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores simultaneously precision tracking and triggering capabilities. RPC signals were acquired with precision timing and charge integrating readout electronics at both ends of the strips. The time resolution was measured to be better than 600 ps and the average spatial resolution was found to be 220 um using charge information and 287 um using timing information. The dual-ended readout allows the determination of the average and the difference of the signal arrival times. The average time was found to be independent of the incident particle position along the strip and is useful for triggering purposes. The time difference yielded a determination of the hit position with a precision of 7.5 mm along the strip. These results demonstrate the feasibility using RPCs for fast and high-resolution triggering and tracking.
△ Less
Submitted 24 October, 2012;
originally announced October 2012.
-
Development of a plasma panel radiation detector: recent progress and key issues
Authors:
Yiftah Silver,
Robert Ball,
James R. Beene,
Yan Benhammou,
Meny Ben-Moshe,
J. W. Chapman,
Tiesheng Dai,
Erez Etzion,
Claudio Ferretti,
Nir Guttman,
Peter S. Friedman,
Daniel S. Levin,
S. Ritt,
Robert L. Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS is conceived as an array of sealed plasma discharge gas cells which can be used for fast response (O(5ns) per pixel), high spatial resolution detection (pixel pi…
▽ More
A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS is conceived as an array of sealed plasma discharge gas cells which can be used for fast response (O(5ns) per pixel), high spatial resolution detection (pixel pitch can be less than 100 micrometer) of ionizing and minimum ionizing particles. The PPS is assembled from non-reactive, intrinsically radiation-hard materials: glass substrates, metal electrodes and inert gas mixtures. We report on the PPS development program, including simulations and design and the first laboratory studies which demonstrate the usage of plasma display panels in measurements of cosmic ray muons, as well as the expansion of experimental results on the detection of betas from radioactive sources.
△ Less
Submitted 30 May, 2012;
originally announced May 2012.
-
The Detection of Ionizing Radiation by Plasma Panel Sensors: Cosmic Muons, Ion Beams and Cancer Therapy
Authors:
Peter S. Friedman,
Robert Ball,
J. W. Chapman,
Claudio Ferretti,
Daniel S. Levin,
Curtis Weaverdyck,
Bing Zhou,
Yan Benhammou,
Erez Etzion,
Nir Guttman,
M. Ben Moshe,
Yiftah Silver,
James R. Beene,
Robert L. Varner Jr.
Abstract:
The plasma panel sensor is an ionizing photon and particle radiation detector derived from PDP technology with high gain and nanosecond response. Experimental results in detecting cosmic ray muons and beta particles from radioactive sources are described along with applications including high energy and nuclear physics, homeland security and cancer therapeutics
The plasma panel sensor is an ionizing photon and particle radiation detector derived from PDP technology with high gain and nanosecond response. Experimental results in detecting cosmic ray muons and beta particles from radioactive sources are described along with applications including high energy and nuclear physics, homeland security and cancer therapeutics
△ Less
Submitted 3 April, 2012;
originally announced April 2012.
-
Streamlined Calibrations of the ATLAS Precision Muon Chambers for Initial LHC Running
Authors:
N. Amram,
R. Ball,
Y. Benhammou,
M. Ben Moshe,
T. Dai,
E. B. Diehl,
J. Dubbert,
E. Etzion,
C. Ferretti,
J. Gregory,
S. Haider,
J. Hindes,
D. S. Levin,
R. Thun,
A. Wilson,
C. Weaverdyck,
Y. Wu,
H. Yang,
B. Zhou,
S. Zimmermann
Abstract:
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT function…
▽ More
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT functions depend on MDT environmental parameters and so must be appropriately calibrated for local chamber conditions. We report on the creation and application of a gas monitor system based calibration program for muon track reconstruction in the LHC startup phase.
△ Less
Submitted 7 March, 2011; v1 submitted 3 March, 2011;
originally announced March 2011.