-
An innovative architecture for a wide band transient monitor on board the HERMES nano-satellite constellation
Authors:
F. Fuschino,
R. Campana,
C. Labanti,
Y. Evangelista,
F. Fiore,
M. Gandola,
M. Grassi,
F. Mele,
F. Ambrosino,
F. Ceraudo,
E. Demenev,
M. Fiorini,
G. Morgante,
R. Piazzolla,
G. Bertuccio,
P. Malcovati,
P. Bellutti,
G. Borghi,
G. Dilillo,
M. Feroci,
F. Ficorella,
G. La Rosa,
P. Nogara,
G. Pauletta,
A. Picciotto
, et al. (13 additional authors not shown)
Abstract:
The HERMES-TP/SP mission, based on a nanosatellite constellation, has very stringent constraints of sensitivity and compactness, and requires an innovative wide energy range instrument. The instrument technology is based on the "siswich" concept, in which custom-designed, low-noise Silicon Drift Detectors are used to simultaneously detect soft X-rays and to readout the optical light produced by th…
▽ More
The HERMES-TP/SP mission, based on a nanosatellite constellation, has very stringent constraints of sensitivity and compactness, and requires an innovative wide energy range instrument. The instrument technology is based on the "siswich" concept, in which custom-designed, low-noise Silicon Drift Detectors are used to simultaneously detect soft X-rays and to readout the optical light produced by the interaction of higher energy photons in GAGG:Ce scintillators. To preserve the inherent excellent spectroscopic performances of SDDs, advanced readout electronics is necessary. In this paper, the HERMES detector architecture concept will be described in detail, as well as the specifically developed front-end ASICs (LYRA-FE and LYRA-BE) and integration solutions. The experimental performance of the integrated system composed by scintillator+SDD+LYRA ASIC will be discussed, demonstrating that the requirements of a wide energy range sensitivity, from 2 keV up to 2 MeV, are met in a compact instrument.
△ Less
Submitted 8 January, 2021;
originally announced January 2021.
-
ESA Voyage 2050 white paper -- GrailQuest: hunting for Atoms of Space and Time hidden in the wrinkle of Space-Time
Authors:
L. Burderi,
A. Sanna,
T. Di Salvo,
L. Amati,
G. Amelino-Camelia,
M. Branchesi,
S. Capozziello,
E. Coccia,
M. Colpi,
E. Costa,
N. D'Amico,
P. De Bernardis,
M. De Laurentis,
M. Della Valle,
H. Falcke,
M. Feroci,
F. Fiore,
F. Frontera,
A. F. Gambino,
G. Ghisellini,
K. Hurley,
R. Iaria,
D. Kataria,
C. Labanti,
G. Lodato
, et al. (8 additional authors not shown)
Abstract:
GrailQuest (Gamma Ray Astronomy International Laboratory for QUantum Exploration of Space-Time) is a mission concept based on a constellation (hundreds/thousands) of nano/micro/small-satellites in low (or near) Earth orbits. Each satellite hosts a non-collimated array of scintillator crystals coupled with Silicon Drift Detectors with broad energy band coverage (keV-MeV range) and excellent tempora…
▽ More
GrailQuest (Gamma Ray Astronomy International Laboratory for QUantum Exploration of Space-Time) is a mission concept based on a constellation (hundreds/thousands) of nano/micro/small-satellites in low (or near) Earth orbits. Each satellite hosts a non-collimated array of scintillator crystals coupled with Silicon Drift Detectors with broad energy band coverage (keV-MeV range) and excellent temporal resolution ( below or equal 100 nanoseconds) each with effective area around 100 cm2. This simple and robust design allows for mass-production of the satellites of the fleet. This revolutionary approach implies a huge reduction of costs, flexibility in the segmented launching strategy, and an incremental long-term plan to increase the number of detectors and their performance: a living observatory for next-generation, space-based astronomical facilities. GrailQuest is conceived as an all-sky monitor for fast localisation of high signal-to-noise ratio transients in the X/gamma-ray band, e.g. the elusive electromagnetic counterparts of gravitational wave events. Robust temporal triangulation techniques will allow unprecedented localisation capabilities, in the keV-MeV band, of a few arcseconds or below, depending on the temporal structure of the transient event. The ambitious ultimate goal of this mission is to perform the first experiment, in quantum gravity, to directly probe space-time structure down to the minuscule Planck scale, by constraining or measuring a first order dispersion relation for light in vacuo. This is obtained by detecting delays between photons of different energies in the prompt emission of Gamma-ray Bursts.
△ Less
Submitted 25 August, 2020; v1 submitted 5 November, 2019;
originally announced November 2019.
-
A compact and modular X and gamma-ray detector with a CsI scintillator and double-readout Silicon Drift Detectors
Authors:
R. Campana,
F. Fuschino,
C. Labanti,
M. Marisaldi,
L. Amati,
M. Fiorini,
M. Uslenghi,
G. Baldazzi,
P. Bellutti,
Y. Evangelista,
I. Elmi,
M. Feroci,
F. Ficorella,
F. Frontera,
A. Picciotto,
C. Piemonte,
A. Rachevski,
I. Rashevskaya,
L. P. Rignanese,
A. Vacchi,
G. Zampa,
N. Zampa,
N. Zorzi
Abstract:
A future compact and modular X and gamma-ray spectrometer (XGS) has been designed and a series of prototypes have been developed and tested. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25 mm2 Silicon Drift Detectors. Digital algorithms are used to discriminate between events absorbed in the Silicon layer (lower energy X rays) and events absorbed i…
▽ More
A future compact and modular X and gamma-ray spectrometer (XGS) has been designed and a series of prototypes have been developed and tested. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25 mm2 Silicon Drift Detectors. Digital algorithms are used to discriminate between events absorbed in the Silicon layer (lower energy X rays) and events absorbed in the scintillator crystal (higher energy X rays and gamma-rays). The prototype characterization is shown and the modular design for future experiments with possible astrophysical applications (e.g. for the THESEUS mission proposed for the ESA M5 call) are discussed.
△ Less
Submitted 20 April, 2017;
originally announced April 2017.
-
The effect of the displacement damage on the Charge Collection Efficiency in Silicon Drift Detectors for the LOFT satellite
Authors:
E. Del Monte,
Y. Evangelista,
E. Bozzo,
F. Cadoux,
A. Rachevski,
G. Zampa,
N. Zampa,
M. Feroci,
M. Pohl,
A. Vacchi
Abstract:
The technology of Silicon Drift Detectors (SDDs) has been selected for the two instruments aboard the Large Observatory For X-ray Timing (LOFT) space mission. LOFT underwent a three year long assessment phase as candidate for the M3 launch opportunity within the "Cosmic Vision 2015 -- 2025" long-term science plan of the European Space Agency. During the LOFT assessment phase, we studied the displa…
▽ More
The technology of Silicon Drift Detectors (SDDs) has been selected for the two instruments aboard the Large Observatory For X-ray Timing (LOFT) space mission. LOFT underwent a three year long assessment phase as candidate for the M3 launch opportunity within the "Cosmic Vision 2015 -- 2025" long-term science plan of the European Space Agency. During the LOFT assessment phase, we studied the displacement damage produced in the SDDs by the protons trapped in the Earth's magnetosphere. In a previous paper we discussed the effects of the Non Ionising Energy Losses from protons on the SDD leakage current. In this paper we report the measurement of the variation of Charge Collection Efficiency produced by displacement damage caused by protons and the comparison with the expected damage in orbit.
△ Less
Submitted 26 March, 2015;
originally announced March 2015.
-
Radiation tests of the Silicon Drift Detectors for LOFT
Authors:
E. Del Monte,
P. Azzarello,
E. Bozzo,
S. Bugiel,
S. Diebold,
Y. Evangelista,
E. Kendziorra,
F. Muleri,
E. Perinati,
A. Rachevski,
G. Zampa,
N. Zampa,
M. Feroci,
M. Pohl,
A. Santangelo,
A. Vacchi
Abstract:
During the three years long assessment phase of the LOFT mission, candidate to the M3 launch opportunity of the ESA Cosmic Vision programme, we estimated and measured the radiation damage of the silicon drift detectors (SDDs) of the satellite instrumentation. In particular, we irradiated the detectors with protons (of 0.8 and 11 MeV energy) to study the increment of leakage current and the variati…
▽ More
During the three years long assessment phase of the LOFT mission, candidate to the M3 launch opportunity of the ESA Cosmic Vision programme, we estimated and measured the radiation damage of the silicon drift detectors (SDDs) of the satellite instrumentation. In particular, we irradiated the detectors with protons (of 0.8 and 11 MeV energy) to study the increment of leakage current and the variation of the charge collection efficiency produced by the displacement damage, and we "bombarded" the detectors with hypervelocity dust grains to measure the effect of the debris impacts. In this paper we describe the measurements and discuss the results in the context of the LOFT mission.
△ Less
Submitted 27 August, 2014;
originally announced August 2014.
-
Baseline design of the filters for the LAD detector on board LOFT
Authors:
M. Barbera,
B. Winter,
J. Coker,
M. Feroci,
T. Kennedy,
D. Walton,
S. Zane
Abstract:
The Large Observatory for X-ray Timing (LOFT) was one of the M3 missions selected for the phase A study in the ESA's Cosmic Vision program. LOFT is designed to perform high-time-resolution X-ray observations of black holes and neutron stars. The main instrument on the LOFT payload is the Large Area Detector (LAD), a collimated experiment with a nominal effective area of ~10 m 2 @ 8 keV, and a spec…
▽ More
The Large Observatory for X-ray Timing (LOFT) was one of the M3 missions selected for the phase A study in the ESA's Cosmic Vision program. LOFT is designed to perform high-time-resolution X-ray observations of black holes and neutron stars. The main instrument on the LOFT payload is the Large Area Detector (LAD), a collimated experiment with a nominal effective area of ~10 m 2 @ 8 keV, and a spectral resolution of ~240 eV in the energy band 2-30 keV. These performances are achieved covering a large collecting area with more than 2000 large-area Silicon Drift Detectors (SDDs) each one coupled to a collimator based on lead-glass micro-channel plates. In order to reduce the thermal load onto the detectors, which are open to Sky, and to protect them from out of band radiation, optical-thermal filter will be mounted in front of the SDDs. Different options have been considered for the LAD filters for best compromise between high quantum efficiency and high mechanical robustness. We present the baseline design of the optical-thermal filters, show the nominal performances, and present preliminary test results performed during the phase A study.
△ Less
Submitted 27 August, 2014;
originally announced August 2014.
-
The SIRIUS Mixed analog-digital ASIC developed for the LOFT LAD and WFM instruments
Authors:
A. Cros,
D. Rambaud,
E. Moutaye,
L. Ravera,
D. Barret,
P. Caïs,
R. Clédassou,
P. Bodin,
JY. Seyler,
A. Bonzo,
M. Feroci,
C. Labanti,
Y. Evangelista,
Y. Favre
Abstract:
We report on the development and characterization of the low-noise, low power, mixed analog-digital SIRIUS ASICs for both the LAD and WFM X-ray instruments of LOFT. The ASICs we developed are reading out large area silicon drift detectors (SDD). Stringent requirements in terms of noise (ENC of 17 e- to achieve an energy resolution on the LAD of 200 eV FWHM at 6 keV) and power consumption (650 μW p…
▽ More
We report on the development and characterization of the low-noise, low power, mixed analog-digital SIRIUS ASICs for both the LAD and WFM X-ray instruments of LOFT. The ASICs we developed are reading out large area silicon drift detectors (SDD). Stringent requirements in terms of noise (ENC of 17 e- to achieve an energy resolution on the LAD of 200 eV FWHM at 6 keV) and power consumption (650 μW per channel) were basis for the ASICs design. These SIRIUS ASICs are developed to match SDD detectors characteristics: 16 channels ASICs adapted for the LAD (970 microns pitch) and 64 channels for the WFM (145 microns pitch) will be fabricated. The ASICs were developed with the 180nm mixed technology of TSMC.
△ Less
Submitted 27 August, 2014;
originally announced August 2014.
-
Characterization of the VEGA ASIC coupled to large area position-sensitive Silicon Drift Detectors
Authors:
R. Campana,
Y. Evangelista,
F. Fuschino,
M. Ahangarianabhari,
D. Macera,
G. Bertuccio,
M. Grassi,
C. Labanti,
M. Marisaldi,
P. Malcovati,
A. Rachevski,
G. Zampa,
N. Zampa,
L. Andreani,
G. Baldazzi,
E. Del Monte,
Y. Favre,
M. Feroci,
F. Muleri,
I. Rashevskaya,
A. Vacchi,
F. Ficorella,
G. Giacomini,
A. Picciotto,
M. Zuffa
Abstract:
Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly useful for experiments in which a good energy resolution combined with a large sensitive area is required, as in the case of X-ray astronomy space missions and medical applications. This paper presents the experimental characterization of VEGA, a custom Application Specific Integrated Circuit (ASIC) used as the front-end…
▽ More
Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly useful for experiments in which a good energy resolution combined with a large sensitive area is required, as in the case of X-ray astronomy space missions and medical applications. This paper presents the experimental characterization of VEGA, a custom Application Specific Integrated Circuit (ASIC) used as the front-end electronics for XDXL-2, a large-area (30.5 cm^2) SDD prototype. The ASICs were integrated on a specifically developed PCB hosting also the detector. Results on the ASIC noise performances, both stand-alone and bonded to the large area SDD, are presented and discussed.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
Measurement of the effect of Non Ionising Energy Losses on the leakage current of Silicon Drift Detector prototypes for the LOFT satellite
Authors:
E. Del Monte,
A. Rachevski,
G. Zampa,
N. Zampa,
P. Azzarello,
E. Bozzo,
R. Campana,
S. Diebold,
Y. Evangelista,
E. Perinati,
M. Feroci,
M. Pohl,
A. Vacchi
Abstract:
The silicon drift detectors are at the basis of the instrumentation aboard the Large Observatory For x-ray Timing (LOFT) satellite mission, which underwent a three year assessment phase within the "Cosmic Vision 2015 - 2025" long-term science plan of the European Space Agency. Silicon detectors are especially sensitive to the displacement damage, produced by the non ionising energy losses of charg…
▽ More
The silicon drift detectors are at the basis of the instrumentation aboard the Large Observatory For x-ray Timing (LOFT) satellite mission, which underwent a three year assessment phase within the "Cosmic Vision 2015 - 2025" long-term science plan of the European Space Agency. Silicon detectors are especially sensitive to the displacement damage, produced by the non ionising energy losses of charged and neutral particles, leading to an increase of the device leakage current and thus worsening the spectral resolution.
During the LOFT assessment phase, we irradiated two silicon drift detectors with a proton beam at the Proton Irradiation Facility in the accelerator of the Paul Scherrer Institute and we measured the increase in leakage current. In this paper we report the results of the irradiation and we discuss the impact of the radiation damage on the LOFT scientific performance.
△ Less
Submitted 24 June, 2014; v1 submitted 21 May, 2014;
originally announced May 2014.
-
The radiation environment in a Low Earth Orbit: the case of BeppoSAX
Authors:
R. Campana,
M. Orlandini,
E. Del Monte,
M. Feroci,
F. Frontera
Abstract:
Low-inclination, low altitude Earth orbits (LEO) are of increasing importance for astrophysical satellites, due to their low background environment. Here, the South Atlantic Anomaly (SAA) is the region with the highest amount of radiation. We study the radiation environment in a LEO (500-600 km altitude, 4 degrees inclination) through the particle background measured by the Particle Monitor (PM) e…
▽ More
Low-inclination, low altitude Earth orbits (LEO) are of increasing importance for astrophysical satellites, due to their low background environment. Here, the South Atlantic Anomaly (SAA) is the region with the highest amount of radiation. We study the radiation environment in a LEO (500-600 km altitude, 4 degrees inclination) through the particle background measured by the Particle Monitor (PM) experiment onboard the BeppoSAX satellite, between 1996 and 2002. Using time series of particle count rates measured by PM we construct intensity maps and derive SAA passage times and fluences. The low-latitude SAA regions are found to have an intensity strongly decreasing with altitude and dependent on the magnetic rigidity. The SAA extent, westward drift and strength vs altitude is shown.
△ Less
Submitted 2 May, 2014;
originally announced May 2014.
-
A setup for soft proton irradiation of X-ray detectors for future astronomical space missions
Authors:
Sebastian Diebold,
Philipp Azzarello,
Ettore Del Monte,
Marco Feroci,
Josef Jochum,
Eckhard Kendziorra,
Emanuele Perinati,
Alexandre Rachevski,
Andrea Santangelo,
Christoph Tenzer,
Andrea Vacchi,
Gianluigi Zampa,
Nicola Zampa
Abstract:
Protons that are trapped in the Earth's magnetic field are one of the main threats to astronomical X-ray observatories. Soft protons, in the range from tens of keV up to a few MeV, impinging on silicon X-ray detectors can lead to a significant degradation of the detector performance. Especially in low earth orbits an enhancement of the soft proton flux has been found. A setup to irradiate detector…
▽ More
Protons that are trapped in the Earth's magnetic field are one of the main threats to astronomical X-ray observatories. Soft protons, in the range from tens of keV up to a few MeV, impinging on silicon X-ray detectors can lead to a significant degradation of the detector performance. Especially in low earth orbits an enhancement of the soft proton flux has been found. A setup to irradiate detectors with soft protons has been constructed at the Van-de-Graaff accelerator of the Physikalisches Institut of the University of Tübingen. Key advantages are a high flux uniformity over a large area, to enable irradiations of large detectors, and a monitoring system for the applied fluence, the beam uniformity, and the spectrum, that allows testing of detector prototypes in early development phases, when readout electronics are not yet available. Two irradiation campaigns have been performed so far with this setup. The irradiated detectors are silicon drift detectors, designated for the use on-board the LOFT space mission. This paper gives a description of the experimental setup and the associated monitoring system.
△ Less
Submitted 16 July, 2013;
originally announced July 2013.
-
Accelerator experiments with soft protons and hyper-velocity dust particles: application to ongoing projects of future X-ray missions
Authors:
E. Perinati,
S. Diebold,
E. Kendziorra,
A. Santangelo,
C. Tenzer,
J. Jochum,
S. Bugiel,
R. Srama,
E. Del Monte,
M. Feroci,
A. Rubini,
A. Rachevski,
G. Zampa,
N. Zampa,
I. Rashevskaya,
A. Vacchi,
P. Azzarello,
E. Bozzo,
J. -W. den Herder,
S. Zane,
S. Brandt,
M. Hernanz,
M. A. Leutenegger,
R. L. Kelley,
C. A. Kilbourne
, et al. (9 additional authors not shown)
Abstract:
We report on our activities, currently in progress, aimed at performing accelerator experiments with soft protons and hyper-velocity dust particles. They include tests of different types of X-ray detectors and related components (such as filters) and measurements of scattering of soft protons and hyper-velocity dust particles off X-ray mirror shells. These activities have been identified as a goal…
▽ More
We report on our activities, currently in progress, aimed at performing accelerator experiments with soft protons and hyper-velocity dust particles. They include tests of different types of X-ray detectors and related components (such as filters) and measurements of scattering of soft protons and hyper-velocity dust particles off X-ray mirror shells. These activities have been identified as a goal in the context of a number of ongoing space projects in order to assess the risk posed by environmental radiation and dust and qualify the adopted instrumentation with respect to possible damage or performance degradation. In this paper we focus on tests for the Silicon Drift Detectors (SDDs) used aboard the LOFT space mission. We use the Van de Graaff accelerators at the University of Tübingen and at the Max Planck Institute for Nuclear Physics (MPIK) in Heidelberg, for soft proton and hyper-velocity dust tests respectively. We present the experimental set-up adopted to perform the tests, status of the activities and some very preliminary results achieved at present time.
△ Less
Submitted 14 September, 2012;
originally announced September 2012.
-
Simulations of the X-ray imaging capabilities of the Silicon Drift Detectors (SDD) for the LOFT Wide Field Monitor
Authors:
Y. Evangelista,
R. Campana,
E. Del Monte,
I. Donnarumma,
M. Feroci,
F. Muleri,
L. Pacciani,
P. Soffitta,
A. Rachevski,
A. Vacchi,
G. Zampa,
N. Zampa,
S. Suchy,
S. Brandt,
C. Budtz-Jørgensen,
M. Hernanz
Abstract:
The Large Observatory For X-ray Timing (LOFT), selected by ESA as one of the four Cosmic Vision M3 candidate missions to undergo an assessment phase, will revolutionize the study of compact objects in our galaxy and of the brightest supermassive black holes in active galactic nuclei. The Large Area Detector (LAD), carrying an unprecedented effective area of 10 m^2, is complemented by a coded-mask…
▽ More
The Large Observatory For X-ray Timing (LOFT), selected by ESA as one of the four Cosmic Vision M3 candidate missions to undergo an assessment phase, will revolutionize the study of compact objects in our galaxy and of the brightest supermassive black holes in active galactic nuclei. The Large Area Detector (LAD), carrying an unprecedented effective area of 10 m^2, is complemented by a coded-mask Wide Field Monitor, in charge of monitoring a large fraction of the sky potentially accessible to the LAD, to provide the history and context for the sources observed by LAD and to trigger its observations on their most interesting and extreme states. In this paper we present detailed simulations of the imaging capabilities of the Silicon Drift Detectors developed for the LOFT Wide Field Monitor detection plane. The simulations explore a large parameter space for both the detector design and the environmental conditions, allowing us to optimize the detector characteristics and demonstrating the X-ray imaging performance of the large-area SDDs in the 2-50 keV energy band.
△ Less
Submitted 7 September, 2012;
originally announced September 2012.
-
First results about on-ground calibration of the Silicon Tracker for the AGILE satellite
Authors:
AGILE Collaboration,
P. W. Cattaneo,
A. Argan,
F. Boffelli,
A. Bulgarelli,
B. Buonomo,
A. W. Chen,
F. D'Ammando,
T. Froysland,
F. Fuschino,
M. Galli,
F. Gianotti,
A. Giuliani,
F. Longo,
M. Marisaldi,
G. Mazzitelli,
A. Pellizzoni,
M. Prest,
G. Pucella,
L. Quintieri,
A. Rappoldi,
M. Tavani,
M. Trifoglio,
A. Trois,
P. Valente
, et al. (43 additional authors not shown)
Abstract:
The AGILE scientific instrument has been calibrated with a tagged $γ$-ray beam at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati (LNF). The goal of the calibration was the measure of the Point Spread Function (PSF) as a function of the photon energy and incident angle and the validation of the Monte Carlo (MC) simulation of the silicon tracker operation. The calibration…
▽ More
The AGILE scientific instrument has been calibrated with a tagged $γ$-ray beam at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati (LNF). The goal of the calibration was the measure of the Point Spread Function (PSF) as a function of the photon energy and incident angle and the validation of the Monte Carlo (MC) simulation of the silicon tracker operation. The calibration setup is described and some preliminary results are presented.
△ Less
Submitted 12 December, 2011;
originally announced December 2011.
-
Characterization of a tagged $γ$-ray beam line at the DA$Φ$NE Beam Test Facility
Authors:
P. W. Cattaneo,
A. Argan,
F. Boffelli,
A. Bulgarelli,
B. Buonomo,
A. W. Chen,
F. D'Ammando,
T. Froysland,
F. Fuschino,
M. Galli,
F. Gianotti,
A. Giuliani,
F. Longo,
M. Marisaldi,
G. Mazzitelli,
A. Pellizzoni,
M. Prest,
G. Pucella,
L. Quintieri,
A. Rappoldi,
M. Tavani,
M. Trifoglio,
A. Trois,
P. Valente,
E. Vallazza
, et al. (42 additional authors not shown)
Abstract:
At the core of the AGILE scientific instrument, designed to operate on a satellite, there is the Gamma Ray Imaging Detector (GRID) consisting of a Silicon Tracker (ST), a Cesium Iodide Mini-Calorimeter and an Anti-Coincidence system of plastic scintillator bars. The ST needs an on-ground calibration with a $γ$-ray beam to validate the simulation used to calculate the energy response function and t…
▽ More
At the core of the AGILE scientific instrument, designed to operate on a satellite, there is the Gamma Ray Imaging Detector (GRID) consisting of a Silicon Tracker (ST), a Cesium Iodide Mini-Calorimeter and an Anti-Coincidence system of plastic scintillator bars. The ST needs an on-ground calibration with a $γ$-ray beam to validate the simulation used to calculate the energy response function and the effective area versus the energy and the direction of the $γ$ rays. A tagged $γ$-ray beam line was designed at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali of Frascati (LNF), based on an electron beam generating $γ$ rays through bremsstrahlung in a position-sensitive target. The $γ$-ray energy is deduced by difference with the post-bremsstrahlung electron energy \cite{prest}-\cite{hasan}. The electron energy is measured by a spectrometer consisting of a dipole magnet and an array of position sensitive silicon strip detectors, the Photon Tagging System (PTS). The use of the combined BTF-PTS system as tagged photon beam requires understanding the efficiency of $γ$-ray tagging, the probability of fake tagging, the energy resolution and the relation of the PTS hit position versus the $γ$-ray energy. This paper describes this study comparing data taken during the AGILE calibration occurred in 2005 with simulation.
△ Less
Submitted 19 January, 2012; v1 submitted 26 November, 2011;
originally announced November 2011.
-
Gamma-Ray Localization of Terrestrial Gamma-Ray Flashes
Authors:
M. Marisaldi,
A. Argan,
A. Trois,
A. Giuliani,
M. Tavani,
C. Labanti,
F. Fuschino,
A. Bulgarelli,
F. Longo,
G. Barbiellini,
E. Del Monte,
E. Moretti,
M. Trifoglio,
E. Costa,
P. Caraveo,
P. W. Cattaneo,
A. Chen,
F. D'Ammando,
G. De Paris,
G. Di Cocco,
G. Di Persio,
I. Donnarumma,
Y. Evangelista,
M. Feroci,
A. Ferrari
, et al. (37 additional authors not shown)
Abstract:
Terrestrial Gamma-Ray Flashes (TGFs) are very short bursts of high energy photons and electrons originating in Earth's atmosphere. We present here a localization study of TGFs carried out at gamma-ray energies above 20 MeV based on an innovative event selection method. We use the AGILE satellite Silicon Tracker data that for the first time have been correlated with TGFs detected by the AGILE Mini-…
▽ More
Terrestrial Gamma-Ray Flashes (TGFs) are very short bursts of high energy photons and electrons originating in Earth's atmosphere. We present here a localization study of TGFs carried out at gamma-ray energies above 20 MeV based on an innovative event selection method. We use the AGILE satellite Silicon Tracker data that for the first time have been correlated with TGFs detected by the AGILE Mini-Calorimeter. We detect 8 TGFs with gamma-ray photons of energies above 20 MeV localized by the AGILE gamma-ray imager with an accuracy of 5-10 degrees at 50 MeV. Remarkably, all TGF-associated gamma rays are compatible with a terrestrial production site closer to the sub-satellite point than 400 km. Considering that our gamma rays reach the AGILE satellite at 540 km altitude with limited scattering or attenuation, our measurements provide the first precise direct localization of TGFs from space.
△ Less
Submitted 28 September, 2010;
originally announced September 2010.
-
Science with the new generation high energy gamma- ray experiments
Authors:
M. Alvarez,
D. D'Armiento,
G. Agnetta,
A. Alberdi,
A. Antonelli,
A. Argan,
P. Assis,
E. A. Baltz,
C. Bambi,
G. Barbiellini,
H. Bartko,
M. Basset,
D. Bastieri,
P. Belli,
G. Benford,
L. Bergstrom,
R. Bernabei,
G. Bertone,
A. Biland,
B. Biondo,
F. Bocchino,
E. Branchini,
M. Brigida,
T. Bringmann,
P. Brogueira
, et al. (175 additional authors not shown)
Abstract:
This Conference is the fifth of a series of Workshops on High Energy Gamma- ray Experiments, following the Conferences held in Perugia 2003, Bari 2004, Cividale del Friuli 2005, Elba Island 2006. This year the focus was on the use of gamma-ray to study the Dark Matter component of the Universe, the origin and propagation of Cosmic Rays, Extra Large Spatial Dimensions and Tests of Lorentz Invaria…
▽ More
This Conference is the fifth of a series of Workshops on High Energy Gamma- ray Experiments, following the Conferences held in Perugia 2003, Bari 2004, Cividale del Friuli 2005, Elba Island 2006. This year the focus was on the use of gamma-ray to study the Dark Matter component of the Universe, the origin and propagation of Cosmic Rays, Extra Large Spatial Dimensions and Tests of Lorentz Invariance.
△ Less
Submitted 4 December, 2007;
originally announced December 2007.
-
Scientific performances of the XAA1.2 front-end chip for silicon microstrip detectors
Authors:
E. Del Monte,
P. Soffitta,
E. Morelli,
L. Pacciani,
G. Porrovecchio,
A. Rubini,
O. Uberti,
E. Costa,
G. Di Persio,
I. Donnarumma,
Y. Evangelista,
M. Feroci,
F. Lazzarotto,
M. Mastropietro,
M. Rapisarda
Abstract:
The XAA1.2 is a custom ASIC chip for silicon microstrip detectors adapted by Ideas for the SuperAGILE instrument on board the AGILE space mission. The chip is equipped with 128 input channels, each one containing a charge preamplifier, shaper, peak detector and stretcher. The most important features of the ASIC are the extended linearity, low noise and low power consumption. The XAA1.2 underwent…
▽ More
The XAA1.2 is a custom ASIC chip for silicon microstrip detectors adapted by Ideas for the SuperAGILE instrument on board the AGILE space mission. The chip is equipped with 128 input channels, each one containing a charge preamplifier, shaper, peak detector and stretcher. The most important features of the ASIC are the extended linearity, low noise and low power consumption. The XAA1.2 underwent extensive laboratory testing in order to study its commandability and functionality and evaluate its scientific performances. In this paper we describe the XAA1.2 features, report the laboratory measurements and discuss the results emphasizing the scientific performances in the context of the SuperAGILE front-end electronics.
△ Less
Submitted 15 November, 2006;
originally announced November 2006.