-
Fiber Organization has Little Effect on Electrical Activation Patterns during Focal Arrhythmias in the Left Atrium
Authors:
Jiyue He,
Arkady M. Pertsov,
Elizabeth M. Cherry,
Flavio H. Fenton,
Caroline H. Roney,
Steven A. Niederer,
Zirui Zang,
Rahul Mangharam
Abstract:
Over the past two decades there has been a steady trend towards the development of realistic models of cardiac conduction with increasing levels of detail. However, making models more realistic complicates their personalization and use in clinical practice due to limited availability of tissue and cellular scale data. One such limitation is obtaining information about myocardial fiber organization…
▽ More
Over the past two decades there has been a steady trend towards the development of realistic models of cardiac conduction with increasing levels of detail. However, making models more realistic complicates their personalization and use in clinical practice due to limited availability of tissue and cellular scale data. One such limitation is obtaining information about myocardial fiber organization in the clinical setting. In this study, we investigated a chimeric model of the left atrium utilizing clinically derived patient-specific atrial geometry and a realistic, yet foreign for a given patient fiber organization. We discovered that even significant variability of fiber organization had a relatively small effect on the spatio-temporal activation pattern during regular pacing. For a given pacing site, the activation maps were very similar across all fiber organizations tested.
△ Less
Submitted 22 April, 2023; v1 submitted 29 October, 2022;
originally announced October 2022.
-
Spatiotemporal correlation uncovers fractional scaling in cardiac tissue
Authors:
Alessandro Loppini,
Alessio Gizzi,
Christian Cherubini,
Elizabeth M. Cherry,
Flavio H. Fenton,
Simonetta Filippi
Abstract:
Complex spatiotemporal patterns of action potential duration have been shown to occur in many mammalian hearts due to a period-doubling bifurcation that develops with increasing frequency of stimulation. Here, through high-resolution optical mapping and numerical simulations, we quantify voltage length scales in canine ventricles via spatiotemporal correlation analysis as a function of stimulation…
▽ More
Complex spatiotemporal patterns of action potential duration have been shown to occur in many mammalian hearts due to a period-doubling bifurcation that develops with increasing frequency of stimulation. Here, through high-resolution optical mapping and numerical simulations, we quantify voltage length scales in canine ventricles via spatiotemporal correlation analysis as a function of stimulation frequency and during fibrillation. We show that i) length scales can vary from 40 to 20 cm during one to one responses, ii) a critical decay length for the onset of the period-doubling bifurcation is present and decreases to less than 3 cm before the transition to fibrillation occurs, iii) fibrillation is characterized by a decay length of about 1 cm. On this evidence, we provide a novel theoretical description of cardiac decay lengths introducing an experimental-based conduction velocity dispersion relation that fits the measured wavelengths with a fractional diffusion exponent of 1.5. We show that an accurate phenomenological mathematical model of the cardiac action potential, fine-tuned upon classical restitution protocols, can provide the correct decay lengths during periodic stimulations but that a domain size scaling via the fractional diffusion exponent of 1.5 is necessary to reproduce experimental fibrillation dynamics. Our study supports the need of generalized reaction-diffusion approaches in characterizing the multiscale features of action potential propagation in cardiac tissue. We propose such an approach as the underlying common basis of synchronization in excitable biological media.
△ Less
Submitted 12 June, 2018;
originally announced June 2018.
-
Mechanism of Discordant Alternans in Spatially Homogeneous Tissue
Authors:
Mari A. Watanabe,
Flavio H Fenton,
Steven J. Evans,
Harold Hastings,
Alain Karma
Abstract:
Discordant alternans,the phenomenon of 2 separate cardiac tissue locations exhibiting action potential duration (APD) alternans of opposite phase, appears to be a potential mechanism for electrocardiographic T wave alternans, but its initiation mechanism is unknown. We studied behavior of one- and two- dimensional cardiac tissue spatially homogenous in all respects, including APD restitution and…
▽ More
Discordant alternans,the phenomenon of 2 separate cardiac tissue locations exhibiting action potential duration (APD) alternans of opposite phase, appears to be a potential mechanism for electrocardiographic T wave alternans, but its initiation mechanism is unknown. We studied behavior of one- and two- dimensional cardiac tissue spatially homogenous in all respects, including APD restitution and conduction velocity restitution, using the Beeler Reuter ion channel model. We found that discordant alternans was initiated when spatial gradients of APD arose dynamically, such as from fixed rate pacing of a cable end (sinus node scenario), or from fixed rate pacing at one site preceded by a single excitation wavefront from another site (ectopic focus scenario). In the sinus node scenario, conduction velocity restitution was necessary to initiate discordant alternans. Alternating regimes of concordant and discordant alternans arose along the length of the cable, with regimes delimited by nodes of fixed APD. The number of observable nodes depended upon pacing rate and tissue length. Differences in beat to beat conduction velocity values at steady state were small. In the ectopic focus scenario, variable conduction velocity was not required for induction of discrodant alternans. In both scenarios, stability of node position was dependent upon electrotonic coupling. Other mathematical models produced qualitatively similar results. We conclude that spatial inhomogeneities of electrical restitution are not requiredd to produce discordant alternans; rather, discordant alternans can arise dynamicaly from interaction of APD and conduction veolocity resstitution with single site pacing, or from APD restitution alone in two site pacing.
△ Less
Submitted 5 April, 2000;
originally announced April 2000.