-
Cryogenic Penning-Trap Apparatus for Precision Experiments with Sympathetically Cooled (anti)protons
Authors:
M. Niemann,
T. Meiners,
J. Mielke,
N. Pulido,
J. Schaper,
M. J. Borchert,
J. M. Cornejo,
A. -G. Paschke,
G. Zarantonello,
H. Hahn,
T. Lang,
C. Manzoni,
M. Marangoni,
G. Cerullo,
U. Morgner,
J. -A. Fenske,
A. Bautista-Salvador,
R. Lehnert,
S. Ulmer,
C. Ospelkaus
Abstract:
Current precision experiments with single (anti)protons to test CPT symmetry progress at a rapid pace, but are complicated by the need to cool particles to sub-thermal energies. We describe a cryogenic Penning-trap setup for $^9$Be$^+$ ions designed to allow coupling of single (anti)protons to laser-cooled atomic ions for sympathetic cooling and quantum logic spectroscopy. We report on trapping an…
▽ More
Current precision experiments with single (anti)protons to test CPT symmetry progress at a rapid pace, but are complicated by the need to cool particles to sub-thermal energies. We describe a cryogenic Penning-trap setup for $^9$Be$^+$ ions designed to allow coupling of single (anti)protons to laser-cooled atomic ions for sympathetic cooling and quantum logic spectroscopy. We report on trapping and laser cooling of clouds and single $^9$Be$^+$ ions. We discuss prospects for a microfabricated trap to allow coupling of single (anti)protons to laser-cooled $^9$Be$^+$ ions for sympathetic laser cooling to sub-mK temperatures on ms time scales.
△ Less
Submitted 18 July, 2021;
originally announced July 2021.
-
A highly stable monolithic enhancement cavity for SHG generation in the UV
Authors:
S. Hannig,
J. Mielke,
J. A. Fenske,
M. Misera,
N. Beev,
C. Ospelkaus,
P. O. Schmidt
Abstract:
We present a highly stable bow-tie power enhancement cavity for critical second-harmonic generation into the UV using a Brewster-cut $β$-BaB$_2$O$_4$ (BBO) nonlinear crystal. The cavity geometry is suitable for all UV wavelengths reachable with BBO and can be modified to accommodate anti-reflection coated crystals, extending its applicability to the entire wavelength range accessible with non-line…
▽ More
We present a highly stable bow-tie power enhancement cavity for critical second-harmonic generation into the UV using a Brewster-cut $β$-BaB$_2$O$_4$ (BBO) nonlinear crystal. The cavity geometry is suitable for all UV wavelengths reachable with BBO and can be modified to accommodate anti-reflection coated crystals, extending its applicability to the entire wavelength range accessible with non-linear frequency conversion. The cavity is length-stabilized using a fast general purpose digital PI controller based on the open source STEMlab 125-14 (formerly Red Pitaya) system acting on a mirror mounted on a fast piezo actuator. We observe $130\,\mathrm{h}$ uninterrupted operation without decay in output power at $313\,\mathrm{nm}$. The robustness of the system has been confirmed by exposing it to accelerations of up to $1\,\mathrm{g}$ with less than $10\%$ in-lock output power variations. Furthermore, the cavity can withstand 30~minutes of acceleration exposure at a level of $3\,\mathrm{g}_\mathrm{rms}$ without substantial change in SHG output power, demonstrating that the design is suitable for transportable setups.
△ Less
Submitted 21 September, 2017;
originally announced September 2017.
-
Neutron detectors for the ESS diffractometers
Authors:
I. Stefanescu,
M. Christensen,
J. Fenske,
R. Hall-Wilton,
P. F. Henry,
O. Kirstein,
M. Mueller,
G. Nowak,
D. Pooley,
D. Raspino,
N. Rhodes,
J. Saroun,
J. Schefer,
E. Schooneveld,
J. Sykora,
W. Schweika
Abstract:
The ambitious instrument suite for the future European Spallation Source whose civil construction started recently in Lund, Sweden, demands a set of diverse and challenging requirements for the neutron detectors. For instance, the unprecedented high flux expected on the samples to be investigated in neutron diffraction or reflectometry experiments requires detectors that can handle high counting r…
▽ More
The ambitious instrument suite for the future European Spallation Source whose civil construction started recently in Lund, Sweden, demands a set of diverse and challenging requirements for the neutron detectors. For instance, the unprecedented high flux expected on the samples to be investigated in neutron diffraction or reflectometry experiments requires detectors that can handle high counting rates, while the investigation of sub-millimeter protein crystals will only be possible with large-area detectors that can achieve a position resolution as low as 200 μm. This has motivated an extensive research and development campaign to advance the state-of-the-art detector and to find new technologies that can reach maturity by the time the ESS will operate at full potential. This paper presents the key detector requirements for three of the Time-of-Flight diffraction instrument concepts selected by the Scientific Advisory Committee to advance into the phase of preliminary engineering design. We discuss the available detector technologies suitable for this particular instrument class and their major challenges. The detector technologies selected by the instrument teams to collect the diffraction patterns are briefly discussed. Analytical calculations, Monte-Carlo simulations, and real experimental data are used to develop a generic method to esti- mate the event rate in the diffraction detectors. The proposed approach is based upon conservative assumptions that use information and input parameters that reflect our current level of knowledge and understanding of the ESS project. We apply this method to make predictions for the future diffraction instruments, and thus provide additional information that can help the instrument teams with the optimisation of the detector designs.
△ Less
Submitted 29 November, 2016; v1 submitted 8 July, 2016;
originally announced July 2016.