-
Below 100 ps CTR using FastIC+, an ASIC including on-chip digitization for ToF-PET and beyond
Authors:
D. Mazzanti,
S. Gomez,
J. Mauricio,
J. Alozy,
F. Bandi,
M. Campbell,
R. Dolenec,
G. El Fakhri,
J. M. Fernandez-Tenllado,
A. Gola,
D. Guberman,
S. Majewski,
R. Manera,
A. Mariscal-Castilla,
M. Penna,
R. Pestotnik,
S. Portero,
A. Paterno,
A. Sanuy,
J. J. Silva,
R. Ballabriga,
D. Gascon
Abstract:
This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This ASIC, manufactured in 65 nm CMOS technology, can readout positive or negative polarity sensors and provides a digitized measurement of the arrival time and energy…
▽ More
This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This ASIC, manufactured in 65 nm CMOS technology, can readout positive or negative polarity sensors and provides a digitized measurement of the arrival time and energy of the detected events with a power consumption of 12.5 mW per channel. On-chip digitization is executed by a Time-to-Digital Converter (TDC) based on a Phase-Locked Loop (PLL) generating 16 phases at 1.28 GHz. The internal TDC introduces a jitter contribution of 31.3 ps FWHM, with minimal impact on timing measurements. When evaluating FastIC+ to readout 3$\times$3 mm$^2$ silicon photomultipliers (SiPMs) with a pulsed laser, we achieved a single-photon time resolution (SPTR) of (98 $\pm$ 1) ps FWHM. We also performed time-of-flight positron emission tomography (ToF-PET) experiments using scintillator crystals of different sizes and materials. With LYSO:Ce,Ca crystals of 2.8$\times$2.8$\times$20 mm$^3$ we obtained a coincidence time resolution (CTR) of (130 $\pm$ 1) ps FWHM. With LGSO crystals of 2$\times$2$\times$3 mm$^3$, a CTR of (85 $\pm$ 1) ps FWHM. To the best of our knowledge, this is the first time that a CTR below 100 ps using on-chip digitization is reported.
△ Less
Submitted 13 June, 2025;
originally announced June 2025.
-
Dual Prompting for Diverse Count-level PET Denoising
Authors:
Xiaofeng Liu,
Yongsong Huang,
Thibault Marin,
Samira Vafay Eslahi,
Tiss Amal,
Yanis Chemli,
Keith Johnson,
Georges El Fakhri,
Jinsong Ouyang
Abstract:
The to-be-denoised positron emission tomography (PET) volumes are inherent with diverse count levels, which imposes challenges for a unified model to tackle varied cases. In this work, we resort to the recently flourished prompt learning to achieve generalizable PET denoising with different count levels. Specifically, we propose dual prompts to guide the PET denoising in a divide-and-conquer manne…
▽ More
The to-be-denoised positron emission tomography (PET) volumes are inherent with diverse count levels, which imposes challenges for a unified model to tackle varied cases. In this work, we resort to the recently flourished prompt learning to achieve generalizable PET denoising with different count levels. Specifically, we propose dual prompts to guide the PET denoising in a divide-and-conquer manner, i.e., an explicitly count-level prompt to provide the specific prior information and an implicitly general denoising prompt to encode the essential PET denoising knowledge. Then, a novel prompt fusion module is developed to unify the heterogeneous prompts, followed by a prompt-feature interaction module to inject prompts into the features. The prompts are able to dynamically guide the noise-conditioned denoising process. Therefore, we are able to efficiently train a unified denoising model for various count levels, and deploy it to different cases with personalized prompts. We evaluated on 1940 low-count PET 3D volumes with uniformly randomly selected 13-22\% fractions of events from 97 $^{18}$F-MK6240 tau PET studies. It shows our dual prompting can largely improve the performance with informed count-level and outperform the count-conditional model.
△ Less
Submitted 5 May, 2025;
originally announced May 2025.
-
Mixture-of-Shape-Experts (MoSE): End-to-End Shape Dictionary Framework to Prompt SAM for Generalizable Medical Segmentation
Authors:
Jia Wei,
Xiaoqi Zhao,
Jonghye Woo,
Jinsong Ouyang,
Georges El Fakhri,
Qingyu Chen,
Xiaofeng Liu
Abstract:
Single domain generalization (SDG) has recently attracted growing attention in medical image segmentation. One promising strategy for SDG is to leverage consistent semantic shape priors across different imaging protocols, scanner vendors, and clinical sites. However, existing dictionary learning methods that encode shape priors often suffer from limited representational power with a small set of o…
▽ More
Single domain generalization (SDG) has recently attracted growing attention in medical image segmentation. One promising strategy for SDG is to leverage consistent semantic shape priors across different imaging protocols, scanner vendors, and clinical sites. However, existing dictionary learning methods that encode shape priors often suffer from limited representational power with a small set of offline computed shape elements, or overfitting when the dictionary size grows. Moreover, they are not readily compatible with large foundation models such as the Segment Anything Model (SAM). In this paper, we propose a novel Mixture-of-Shape-Experts (MoSE) framework that seamlessly integrates the idea of mixture-of-experts (MoE) training into dictionary learning to efficiently capture diverse and robust shape priors. Our method conceptualizes each dictionary atom as a shape expert, which specializes in encoding distinct semantic shape information. A gating network dynamically fuses these shape experts into a robust shape map, with sparse activation guided by SAM encoding to prevent overfitting. We further provide this shape map as a prompt to SAM, utilizing the powerful generalization capability of SAM through bidirectional integration. All modules, including the shape dictionary, are trained in an end-to-end manner. Extensive experiments on multiple public datasets demonstrate its effectiveness.
△ Less
Submitted 13 April, 2025;
originally announced April 2025.
-
PET mapping of receptor occupancy using joint direct parametric reconstruction
Authors:
Thibault Marin,
Vasily Belov,
Yanis Chemli,
Jinsong Ouyang,
Yassir Najmaoui,
Georges El Fakhri,
Sridhar Duvvuri,
Philip Iredale,
Nicolas J. Guehl,
Marc D. Normandin,
Yoann Petibon
Abstract:
Receptor occupancy (RO) studies using PET neuroimaging play a critical role in the development of drugs targeting the central nervous system (CNS). The conventional approach to estimate drug receptor occupancy consists in estimation of binding potential changes between two PET scans (baseline and post-drug injection). This estimation is typically performed separately for each scan by first reconst…
▽ More
Receptor occupancy (RO) studies using PET neuroimaging play a critical role in the development of drugs targeting the central nervous system (CNS). The conventional approach to estimate drug receptor occupancy consists in estimation of binding potential changes between two PET scans (baseline and post-drug injection). This estimation is typically performed separately for each scan by first reconstructing dynamic PET scan data before fitting a kinetic model to time activity curves. This approach fails to properly model the noise in PET measurements, resulting in poor RO estimates, especially in low receptor density regions. Objective: In this work, we evaluate a novel joint direct parametric reconstruction framework to directly estimate distributions of RO and other kinetic parameters in the brain from a pair of baseline and post-drug injection dynamic PET scans. Methods: The proposed method combines the use of regularization on RO maps with alternating optimization to enable estimation of occupancy even in low binding regions. Results: Simulation results demonstrate the quantitative improvement of this method over conventional approaches in terms of accuracy and precision of occupancy. The proposed method is also evaluated in preclinical in-vivo experiments using 11C-MK-6884 and a muscarinic acetylcholine receptor 4 positive allosteric modulator drug, showing improved estimation of receptor occupancy as compared to traditional estimators. Conclusion: The proposed joint direct estimation framework improves RO estimation compared to conventional methods, especially in intermediate to low-binding regions. Significance: This work could potentially facilitate the evaluation of new drug candidates targeting the CNS.
△ Less
Submitted 19 October, 2024;
originally announced October 2024.
-
Free-breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model
Authors:
Wonil Lee,
Paul Kyu Han,
Thibault Marin,
Ismaël B. G. Mounime,
Samira Vafay Eslahi,
Yanis Djebra,
Didi Chi,
Felicitas J. Bijari,
Marc D. Normandin,
Georges El Fakhri,
Chao Ma
Abstract:
$\textbf{Purpose:}$ To develop a new method for free-breathing 3D extracellular volume (ECV) mapping of the whole heart at 3T. $\textbf{Methods:}…
▽ More
$\textbf{Purpose:}$ To develop a new method for free-breathing 3D extracellular volume (ECV) mapping of the whole heart at 3T. $\textbf{Methods:}$ A free-breathing 3D cardiac ECV mapping method was developed at 3T. T1 mapping was performed before and after contrast agent injection using a free-breathing ECG-gated inversion-recovery sequence with spoiled gradient echo readout. A linear tangent space alignment (LTSA) model-based method was used to reconstruct high-frame-rate dynamic images from (k,t)-space data sparsely sampled along a random stack-of-stars trajectory. Joint T1 and transmit B1 estimation was performed voxel-by-voxel for pre- and post-contrast T1 mapping. To account for the time-varying T1 after contrast agent injection, a linearly time-varying T1 model was introduced for post-contrast T1 mapping. ECV maps were generated by aligning pre- and post-contrast T1 maps through affine transformation. $\textbf{Results:}$ The feasibility of the proposed method was demonstrated using in vivo studies with six healthy volunteers at 3T. We obtained 3D ECV maps at a spatial resolution of 1.9$\times$1.9$\times$4.5 $mm^{3}$ and a FOV of 308$\times$308$\times$144 $mm^{3}$, with a scan time of 10.1$\pm$1.4 and 10.6$\pm$1.6 min before and after contrast agent injection, respectively. The ECV maps and the pre- and post-contrast T1 maps obtained by the proposed method were in good agreement with the 2D MOLLI method both qualitatively and quantitatively. $\textbf{Conclusion:}$ The proposed method allows for free-breathing 3D ECV mapping of the whole heart within a practically feasible imaging time. The estimated ECV values from the proposed method were comparable to those from the existing method. $\textbf{Keywords:}$ cardiac extracellular volume (ECV) mapping, cardiac T1 mapping, linear tangent space alignment (LTSA), manifold learning
△ Less
Submitted 22 August, 2024;
originally announced August 2024.
-
Point-supervised Brain Tumor Segmentation with Box-prompted MedSAM
Authors:
Xiaofeng Liu,
Jonghye Woo,
Chao Ma,
Jinsong Ouyang,
Georges El Fakhri
Abstract:
Delineating lesions and anatomical structure is important for image-guided interventions. Point-supervised medical image segmentation (PSS) has great potential to alleviate costly expert delineation labeling. However, due to the lack of precise size and boundary guidance, the effectiveness of PSS often falls short of expectations. Although recent vision foundational models, such as the medical seg…
▽ More
Delineating lesions and anatomical structure is important for image-guided interventions. Point-supervised medical image segmentation (PSS) has great potential to alleviate costly expert delineation labeling. However, due to the lack of precise size and boundary guidance, the effectiveness of PSS often falls short of expectations. Although recent vision foundational models, such as the medical segment anything model (MedSAM), have made significant advancements in bounding-box-prompted segmentation, it is not straightforward to utilize point annotation, and is prone to semantic ambiguity. In this preliminary study, we introduce an iterative framework to facilitate semantic-aware point-supervised MedSAM. Specifically, the semantic box-prompt generator (SBPG) module has the capacity to convert the point input into potential pseudo bounding box suggestions, which are explicitly refined by the prototype-based semantic similarity. This is then succeeded by a prompt-guided spatial refinement (PGSR) module that harnesses the exceptional generalizability of MedSAM to infer the segmentation mask, which also updates the box proposal seed in SBPG. Performance can be progressively improved with adequate iterations. We conducted an evaluation on BraTS2018 for the segmentation of whole brain tumors and demonstrated its superior performance compared to traditional PSS methods and on par with box-supervised methods.
△ Less
Submitted 1 August, 2024;
originally announced August 2024.
-
Synergistic Sensing: Application of SiNWs-PANI:MO$_x$ Heterostructures for Human Respiratory Monitoring
Authors:
M. T. Sultan,
A. Dumitru,
E. A. Fakhri,
R. E. Brophy,
S. T. Ingvarsson,
A. Manolescu,
H. G. Svavarsson
Abstract:
In this study we investigate novel hybrid structure of silicon nanowires (SiNWs) coated with PANI:metaloxide(MO$_x$) nanoparticles i.e., WO$_3$ and TiO$_2$. The SiNWs were fabricated using MACE, whereas PANI:MO$_x$ were deposited using chemical oxidative polymerization method on SiNWs. To this date little attempts has been done to utilize such hybrid structures for respiratory sensing. The structu…
▽ More
In this study we investigate novel hybrid structure of silicon nanowires (SiNWs) coated with PANI:metaloxide(MO$_x$) nanoparticles i.e., WO$_3$ and TiO$_2$. The SiNWs were fabricated using MACE, whereas PANI:MO$_x$ were deposited using chemical oxidative polymerization method on SiNWs. To this date little attempts has been done to utilize such hybrid structures for respiratory sensing. The structures were characterized using RAMAN spectroscopy, X-ray diffraction, Electron disperssive spectroscopy, and Scanning electron microscopy. The electrical characterization to obtain respiratory sensing reveals excellent response compared to those obtained for SiNWs:MO$_x$ and SiNWs:PANI. Such enhancement in sensitivity is attributed to formation p-n heterojunction along side with wider conduction channel provided of PANI, increased porosity in SiNWs/PANI:WO$_3$ hybrid structures, providing active sites, increased oxygen vacancies and large surface area compared to that of pure MO$_x$ nanoparticles. Further, an improved drift in base line and sensor stability was established for the structure with PANI:WO$_3$ as compared to the PANI:TiO$_2$.
△ Less
Submitted 10 June, 2024;
originally announced June 2024.
-
Nuclear Medicine Artificial Intelligence in Action: The Bethesda Report (AI Summit 2024)
Authors:
Arman Rahmim,
Tyler J. Bradshaw,
Guido Davidzon,
Joyita Dutta,
Georges El Fakhri,
Munir Ghesani,
Nicolas A. Karakatsanis,
Quanzheng Li,
Chi Liu,
Emilie Roncali,
Babak Saboury,
Tahir Yusufaly,
Abhinav K. Jha
Abstract:
The 2nd SNMMI Artificial Intelligence (AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD, on February 29 - March 1, 2024. Bringing together various community members and stakeholders, and following up on a prior successful 2022 AI Summit, the summit theme was: AI in Action. Six key topics included (i) an overview of prior and ongoing efforts by the AI task force, (ii) em…
▽ More
The 2nd SNMMI Artificial Intelligence (AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD, on February 29 - March 1, 2024. Bringing together various community members and stakeholders, and following up on a prior successful 2022 AI Summit, the summit theme was: AI in Action. Six key topics included (i) an overview of prior and ongoing efforts by the AI task force, (ii) emerging needs and tools for computational nuclear oncology, (iii) new frontiers in large language and generative models, (iv) defining the value proposition for the use of AI in nuclear medicine, (v) open science including efforts for data and model repositories, and (vi) issues of reimbursement and funding. The primary efforts, findings, challenges, and next steps are summarized in this manuscript.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Treatment-wise Glioblastoma Survival Inference with Multi-parametric Preoperative MRI
Authors:
Xiaofeng Liu,
Nadya Shusharina,
Helen A Shih,
C. -C. Jay Kuo,
Georges El Fakhri,
Jonghye Woo
Abstract:
In this work, we aim to predict the survival time (ST) of glioblastoma (GBM) patients undergoing different treatments based on preoperative magnetic resonance (MR) scans. The personalized and precise treatment planning can be achieved by comparing the ST of different treatments. It is well established that both the current status of the patient (as represented by the MR scans) and the choice of tr…
▽ More
In this work, we aim to predict the survival time (ST) of glioblastoma (GBM) patients undergoing different treatments based on preoperative magnetic resonance (MR) scans. The personalized and precise treatment planning can be achieved by comparing the ST of different treatments. It is well established that both the current status of the patient (as represented by the MR scans) and the choice of treatment are the cause of ST. While previous related MR-based glioblastoma ST studies have focused only on the direct mapping of MR scans to ST, they have not included the underlying causal relationship between treatments and ST. To address this limitation, we propose a treatment-conditioned regression model for glioblastoma ST that incorporates treatment information in addition to MR scans. Our approach allows us to effectively utilize the data from all of the treatments in a unified manner, rather than having to train separate models for each of the treatments. Furthermore, treatment can be effectively injected into each convolutional layer through the adaptive instance normalization we employ. We evaluate our framework on the BraTS20 ST prediction task. Three treatment options are considered: Gross Total Resection (GTR), Subtotal Resection (STR), and no resection. The evaluation results demonstrate the effectiveness of injecting the treatment for estimating GBM survival.
△ Less
Submitted 10 February, 2024;
originally announced February 2024.
-
Posterior Estimation for Dynamic PET imaging using Conditional Variational Inference
Authors:
Xiaofeng Liu,
Thibault Marin,
Tiss Amal,
Jonghye Woo,
Georges El Fakhri,
Jinsong Ouyang
Abstract:
This work aims efficiently estimating the posterior distribution of kinetic parameters for dynamic positron emission tomography (PET) imaging given a measurement of time of activity curve. Considering the inherent information loss from parametric imaging to measurement space with the forward kinetic model, the inverse mapping is ambiguous. The conventional (but expensive) solution can be the Marko…
▽ More
This work aims efficiently estimating the posterior distribution of kinetic parameters for dynamic positron emission tomography (PET) imaging given a measurement of time of activity curve. Considering the inherent information loss from parametric imaging to measurement space with the forward kinetic model, the inverse mapping is ambiguous. The conventional (but expensive) solution can be the Markov Chain Monte Carlo (MCMC) sampling, which is known to produce unbiased asymptotical estimation. We propose a deep-learning-based framework for efficient posterior estimation. Specifically, we counteract the information loss in the forward process by introducing latent variables. Then, we use a conditional variational autoencoder (CVAE) and optimize its evidence lower bound. The well-trained decoder is able to infer the posterior with a given measurement and the sampled latent variables following a simple multivariate Gaussian distribution. We validate our CVAE-based method using unbiased MCMC as the reference for low-dimensional data (a single brain region) with the simplified reference tissue model.
△ Less
Submitted 24 October, 2023;
originally announced October 2023.
-
Incremental Learning for Heterogeneous Structure Segmentation in Brain Tumor MRI
Authors:
Xiaofeng Liu,
Helen A. Shih,
Fangxu Xing,
Emiliano Santarnecchi,
Georges El Fakhri,
Jonghye Woo
Abstract:
Deep learning (DL) models for segmenting various anatomical structures have achieved great success via a static DL model that is trained in a single source domain. Yet, the static DL model is likely to perform poorly in a continually evolving environment, requiring appropriate model updates. In an incremental learning setting, we would expect that well-trained static models are updated, following…
▽ More
Deep learning (DL) models for segmenting various anatomical structures have achieved great success via a static DL model that is trained in a single source domain. Yet, the static DL model is likely to perform poorly in a continually evolving environment, requiring appropriate model updates. In an incremental learning setting, we would expect that well-trained static models are updated, following continually evolving target domain data -- e.g., additional lesions or structures of interest -- collected from different sites, without catastrophic forgetting. This, however, poses challenges, due to distribution shifts, additional structures not seen during the initial model training, and the absence of training data in a source domain. To address these challenges, in this work, we seek to progressively evolve an ``off-the-shelf" trained segmentation model to diverse datasets with additional anatomical categories in a unified manner. Specifically, we first propose a divergence-aware dual-flow module with balanced rigidity and plasticity branches to decouple old and new tasks, which is guided by continuous batch renormalization. Then, a complementary pseudo-label training scheme with self-entropy regularized momentum MixUp decay is developed for adaptive network optimization. We evaluated our framework on a brain tumor segmentation task with continually changing target domains -- i.e., new MRI scanners/modalities with incremental structures. Our framework was able to well retain the discriminability of previously learned structures, hence enabling the realistic life-long segmentation model extension along with the widespread accumulation of big medical data.
△ Less
Submitted 30 May, 2023;
originally announced May 2023.
-
Attentive Continuous Generative Self-training for Unsupervised Domain Adaptive Medical Image Translation
Authors:
Xiaofeng Liu,
Jerry L. Prince,
Fangxu Xing,
Jiachen Zhuo,
Reese Timothy,
Maureen Stone,
Georges El Fakhri,
Jonghye Woo
Abstract:
Self-training is an important class of unsupervised domain adaptation (UDA) approaches that are used to mitigate the problem of domain shift, when applying knowledge learned from a labeled source domain to unlabeled and heterogeneous target domains. While self-training-based UDA has shown considerable promise on discriminative tasks, including classification and segmentation, through reliable pseu…
▽ More
Self-training is an important class of unsupervised domain adaptation (UDA) approaches that are used to mitigate the problem of domain shift, when applying knowledge learned from a labeled source domain to unlabeled and heterogeneous target domains. While self-training-based UDA has shown considerable promise on discriminative tasks, including classification and segmentation, through reliable pseudo-label filtering based on the maximum softmax probability, there is a paucity of prior work on self-training-based UDA for generative tasks, including image modality translation. To fill this gap, in this work, we seek to develop a generative self-training (GST) framework for domain adaptive image translation with continuous value prediction and regression objectives. Specifically, we quantify both aleatoric and epistemic uncertainties within our GST using variational Bayes learning to measure the reliability of synthesized data. We also introduce a self-attention scheme that de-emphasizes the background region to prevent it from dominating the training process. The adaptation is then carried out by an alternating optimization scheme with target domain supervision that focuses attention on the regions with reliable pseudo-labels. We evaluated our framework on two cross-scanner/center, inter-subject translation tasks, including tagged-to-cine magnetic resonance (MR) image translation and T1-weighted MR-to-fractional anisotropy translation. Extensive validations with unpaired target domain data showed that our GST yielded superior synthesis performance in comparison to adversarial training UDA methods.
△ Less
Submitted 23 May, 2023;
originally announced May 2023.
-
Posterior Estimation Using Deep Learning: A Simulation Study of Compartmental Modeling in Dynamic PET
Authors:
Xiaofeng Liu,
Thibault Marin,
Tiss Amal,
Jonghye Woo,
Georges El Fakhri,
Jinsong Ouyang
Abstract:
Background: In medical imaging, images are usually treated as deterministic, while their uncertainties are largely underexplored. Purpose: This work aims at using deep learning to efficiently estimate posterior distributions of imaging parameters, which in turn can be used to derive the most probable parameters as well as their uncertainties. Methods: Our deep learning-based approaches are based o…
▽ More
Background: In medical imaging, images are usually treated as deterministic, while their uncertainties are largely underexplored. Purpose: This work aims at using deep learning to efficiently estimate posterior distributions of imaging parameters, which in turn can be used to derive the most probable parameters as well as their uncertainties. Methods: Our deep learning-based approaches are based on a variational Bayesian inference framework, which is implemented using two different deep neural networks based on conditional variational auto-encoder (CVAE), CVAE-dual-encoder and CVAE-dual-decoder. The conventional CVAE framework, i.e., CVAE-vanilla, can be regarded as a simplified case of these two neural networks. We applied these approaches to a simulation study of dynamic brain PET imaging using a reference region-based kinetic model. Results: In the simulation study, we estimated posterior distributions of PET kinetic parameters given a measurement of time-activity curve. Our proposed CVAE-dual-encoder and CVAE-dual-decoder yield results that are in good agreement with the asymptotically unbiased posterior distributions sampled by Markov Chain Monte Carlo (MCMC). The CVAE-vanilla can also be used for estimating posterior distributions, although it has an inferior performance to both CVAE-dual-encoder and CVAE-dual-decoder. Conclusions: We have evaluated the performance of our deep learning approaches for estimating posterior distributions in dynamic brain PET. Our deep learning approaches yield posterior distributions, which are in good agreement with unbiased distributions estimated by MCMC. All these neural networks have different characteristics and can be chosen by the user for specific applications. The proposed methods are general and can be adapted to other problems.
△ Less
Submitted 17 March, 2023;
originally announced March 2023.
-
Ge coated silicon nanowires as human respiratory sensing device
Authors:
E. Fakhri,
M. T. Sultan,
A. Manolescu,
S. Ingvarsson,
H. G. Svavarsson
Abstract:
We report on Ge coated silicon nanowires (SiNWs) sensors synthesized with metal assisted chemical etching and qualify their functionality as human respiratory sensor. The sensors were made from p-type single-crystalline (100) silicon wafers using a silver catalysed top-down etching, afterwards coated by 50 nm Ge thin layer using a magnetron sputtering. The Ge post-treatment were performed by rapid…
▽ More
We report on Ge coated silicon nanowires (SiNWs) sensors synthesized with metal assisted chemical etching and qualify their functionality as human respiratory sensor. The sensors were made from p-type single-crystalline (100) silicon wafers using a silver catalysed top-down etching, afterwards coated by 50 nm Ge thin layer using a magnetron sputtering. The Ge post-treatment were performed by rapid thermal annealing (RTA) at 450 and 700 C degrees. The sensors were characterized by X-ray diffraction diffractogram and scanning electron microscopy. It is demonstrated that the sensors are highly sensitive as human breath detectors, with rapid response and frequency detect-ability. They are also shown to be a good candidate for human respiratory diseases diagnoses.
△ Less
Submitted 17 February, 2023;
originally announced February 2023.
-
PET image denoising based on denoising diffusion probabilistic models
Authors:
Kuang Gong,
Keith A. Johnson,
Georges El Fakhri,
Quanzheng Li,
Tinsu Pan
Abstract:
Due to various physical degradation factors and limited counts received, PET image quality needs further improvements. The denoising diffusion probabilistic models (DDPM) are distribution learning-based models, which try to transform a normal distribution into a specific data distribution based on iterative refinements. In this work, we proposed and evaluated different DDPM-based methods for PET i…
▽ More
Due to various physical degradation factors and limited counts received, PET image quality needs further improvements. The denoising diffusion probabilistic models (DDPM) are distribution learning-based models, which try to transform a normal distribution into a specific data distribution based on iterative refinements. In this work, we proposed and evaluated different DDPM-based methods for PET image denoising. Under the DDPM framework, one way to perform PET image denoising is to provide the PET image and/or the prior image as the network input. Another way is to supply the prior image as the input with the PET image included in the refinement steps, which can fit for scenarios of different noise levels. 120 18F-FDG datasets and 140 18F-MK-6240 datasets were utilized to evaluate the proposed DDPM-based methods. Quantification show that the DDPM-based frameworks with PET information included can generate better results than the nonlocal mean and Unet-based denoising methods. Adding additional MR prior in the model can help achieve better performance and further reduce the uncertainty during image denoising. Solely relying on MR prior while ignoring the PET information can result in large bias. Regional and surface quantification shows that employing MR prior as the network input while embedding PET image as a data-consistency constraint during inference can achieve the best performance. In summary, DDPM-based PET image denoising is a flexible framework, which can efficiently utilize prior information and achieve better performance than the nonlocal mean and Unet-based denoising methods.
△ Less
Submitted 14 September, 2022; v1 submitted 13 September, 2022;
originally announced September 2022.
-
Feasibility study of clinical target volume definition for soft-tissue sarcoma using muscle fiber orientations derived from diffusion tensor imaging
Authors:
Nadya Shusharina,
Xiaofeng Liu,
Jaume Coll-Font,
Anna Foster,
Georges El Fakhri,
Jonghye Woo,
Thomas Bortfeld,
Christopher Nguyen
Abstract:
Objective: Soft-tissue sarcoma spreads preferentially along muscle fibers. We explore the utility of deriving muscle fiber orientations from diffusion tensor MRI (DT-MRI) for defining the boundary of the clinical target volume in muscle tissue. Approach: We recruited eight healthy volunteers to acquire MR images of the left and right thigh. The imaging session consisted of (a) two MRI spin-echo-ba…
▽ More
Objective: Soft-tissue sarcoma spreads preferentially along muscle fibers. We explore the utility of deriving muscle fiber orientations from diffusion tensor MRI (DT-MRI) for defining the boundary of the clinical target volume in muscle tissue. Approach: We recruited eight healthy volunteers to acquire MR images of the left and right thigh. The imaging session consisted of (a) two MRI spin-echo-based scans, T1- and T2-weighted; (b) a diffusion weighted (DW) spin-echo-based scan using an echo planar acquisition with fat suppression. The thigh muscles were auto-segmented using CNN. DT-MRI data was used as a geometry encoding input to solve the anisotropic Eikonal equation with Hamiltonian Fast-Marching method. The isosurfaces of the solution modeled the CTV boundary. Main results: The auto-segmented muscles of the thigh agreed with manually delineated with the Dice score ranging from 0.8 to 0.94 for different muscles. Anisotropy of the isosurfaces was compared across muscles with different anatomical orientations within a thigh, between muscles in left and right thighs of each subject, and between different subjects. Analysis showed a high degree of consistency across all comparisons. The distance from the GTV to the isosurface and the eigenvalues ratio are two controlling parameters for the extent and shape of the CTV. Significance: Our feasibility study with healthy volunteers shows the promise of using muscle fiber orientations derived from diffusion weighted MRI data for automated generation of anisotropic CTV boundary in soft tissue sarcoma. Our contribution is significant as it is expected to lead to the improvements in the treatment outcomes of soft-tissue sarcoma patients undergoing radiotherapy and decrease amputation rate for a subset of patients. We expect such improvements to have a strong positive impact for the cancer centers with small volume of sarcoma patients.
△ Less
Submitted 20 June, 2022;
originally announced June 2022.
-
Piezoresistance characterization of silicon nanowires in uniaxial and isostatic pressure variation
Authors:
Elham Fakhri,
Rodica Plugaru,
Muhammad Taha Sultan,
Thorsteinn Hanning Kristinsson,
Hákon Örn Árnason,
Neculai Plugaru,
Andrei Manolescu,
Snorri Ingvarsson,
Halldor Gudfinnur Svavarsson
Abstract:
Silicon nanowires (SiNWs) are known to exhibit large piezoresistance (PZR) effect, making it suitable for various sensing applications. Here, we report the results of a PZR investigation on randomly distributed and interconnected vertical silicon nanowire arrays as a pressure sensor. The samples were produced from p-type (100) Si wafers using a silver catalysed top-down etching process. The piezor…
▽ More
Silicon nanowires (SiNWs) are known to exhibit large piezoresistance (PZR) effect, making it suitable for various sensing applications. Here, we report the results of a PZR investigation on randomly distributed and interconnected vertical silicon nanowire arrays as a pressure sensor. The samples were produced from p-type (100) Si wafers using a silver catalysed top-down etching process. The piezoresistance response of these SiNW arrays was analysed by measuring their I-V characteristics under applied uniaxial as well as isostatic pressure. The interconnected SiNWs exhibit increased mechanical stability in comparison with separated or periodic nanowires. The repeatability of the fabrication process and statistical distribution of measurements were also tested on several samples from different batches. A sensing resolution down to roughly \SI{1}{\milli\bar} pressure was observed with uniaxial force application, and more than two orders of magnitude resistance variation was determined for isostatic pressure below atmospheric pressure.
△ Less
Submitted 23 June, 2022; v1 submitted 10 June, 2022;
originally announced June 2022.
-
Free-breathing 3D Cardiac T1 Mapping with Transmit B1 Correction at 3T
Authors:
Paul Kyu Han,
Thibault Marin,
Yanis Djebra,
Vanessa Landes,
Yue Zhuo,
Georges El Fakhri,
Chao Ma
Abstract:
Purpose: To develop a cardiac T1 mapping method for free-breathing 3D T1 mapping of the whole heart at 3T with transmit B1 (B1+) correction Methods: A free-breathing, ECG-gated inversion recovery sequence with spoiled gradient-echo readout was developed and optimized for cardiac T1 mapping at 3T. High-frame rate dynamic images were reconstructed from sparse (k,t)-space data acquired along a stack-…
▽ More
Purpose: To develop a cardiac T1 mapping method for free-breathing 3D T1 mapping of the whole heart at 3T with transmit B1 (B1+) correction Methods: A free-breathing, ECG-gated inversion recovery sequence with spoiled gradient-echo readout was developed and optimized for cardiac T1 mapping at 3T. High-frame rate dynamic images were reconstructed from sparse (k,t)-space data acquired along a stack-of-stars trajectory using a subspace-based method for accelerated imaging. Joint T1 and flip-angle (FA) estimation was performed in T1 mapping to improve its robustness to B1+ inhomogeneity. Subject-specific timing of data acquisition was utilized in the estimation to account for natural heart-rate variations during the imaging experiment. Results: Simulations showed that accuracy and precision of T1 mapping can be improved with joint T1 and FA estimation and optimized ECG-gated SPGR-based IR acquisition scheme. The phantom study showed good agreement between the T1 maps from the proposed method and the reference method. 3D cardiac T1 maps (40 slices) were obtained at a 1.9 mm in-plane and 4.5 mm through-plane spatial resolution from healthy subjects (n=6) with an average imaging time of 14.2 +- 1.6 min (heartbeat rate: 64.2 +- 7.1 bpm), showing myocardial T1 values comparable to those obtained from MOLLI. The proposed method generated B1+ maps with spatially smooth variation showing 21-32% and 11-15% variations across the septal-lateral and inferior-anterior regions of the myocardium in the left ventricle. Conclusion: The proposed method allows free-breathing 3D T1 mapping of the whole-heart with transmit B1 correction in a practical imaging time.
△ Less
Submitted 15 November, 2021;
originally announced November 2021.
-
Deep learning-based GTV contouring modeling inter- and intra- observer variability in sarcomas
Authors:
Thibault Marin,
Yue Zhuo,
Rita Maria Lahoud,
Fei Tian,
Xiaoyue Ma,
Fangxu Xing,
Maryam Moteabbed,
Xiaofeng Liu,
Kira Grogg,
Nadya Shusharina,
Jonghye Woo,
Chao Ma,
Yen-Lin E. Chen,
Georges El Fakhri
Abstract:
Background and purpose: The delineation of the gross tumor volume (GTV) is a critical step for radiation therapy treatment planning. The delineation procedure is typically performed manually which exposes two major issues: cost and reproducibility. Delineation is a time-consuming process that is subject to inter- and intra-observer variability. While methods have been proposed to predict GTV conto…
▽ More
Background and purpose: The delineation of the gross tumor volume (GTV) is a critical step for radiation therapy treatment planning. The delineation procedure is typically performed manually which exposes two major issues: cost and reproducibility. Delineation is a time-consuming process that is subject to inter- and intra-observer variability. While methods have been proposed to predict GTV contours, typical approaches ignore variability and therefore fail to utilize the valuable confidence information offered by multiple contours. Materials and methods: In this work we propose an automatic GTV contouring method for soft-tissue sarcomas from X-ray computed tomography (CT) images, using deep learning by integrating inter- and intra-observer variability in the learned model. Sixty-eight patients with soft tissue and bone sarcomas were considered in this evaluation, all underwent pre-operative CT imaging used to perform GTV delineation. Four radiation oncologists and radiologists performed three contouring trials each for all patients. We quantify variability by defining confidence levels based on the frequency of inclusion of a given voxel into the GTV and use a deep convolutional neural network to learn GTV confidence maps. Results: Results were compared to confidence maps from the four readers as well as ground-truth consensus contours established jointly by all readers. The resulting continuous Dice score between predicted and true confidence maps was 87% and the Hausdorff distance was 14 mm. Conclusion: Results demonstrate the ability of the proposed method to predict accurate contours while utilizing variability and as such it can be used to improve clinical workflow.
△ Less
Submitted 10 October, 2021;
originally announced October 2021.
-
Motion correction for PET using subspace-based real-time MR imaging in simultaneous PET/MR
Authors:
Thibault Marin,
Yanis Djebra,
Paul K. Han,
Yanis Chemli,
Isabelle Bloch,
Georges El Fakhri,
Jinsong Ouyang,
Yoann Petibon,
Chao Ma
Abstract:
Image quality of PET reconstructions is degraded by subject motion occurring during the acquisition. MR-based motion correction approaches have been studied for PET/MR scanners and have been successful at capturing regular motion patterns, when used in conjunction with surrogate signals (e.g. navigators) to detect motion. However, handling irregular respiratory motion and bulk motion remains chall…
▽ More
Image quality of PET reconstructions is degraded by subject motion occurring during the acquisition. MR-based motion correction approaches have been studied for PET/MR scanners and have been successful at capturing regular motion patterns, when used in conjunction with surrogate signals (e.g. navigators) to detect motion. However, handling irregular respiratory motion and bulk motion remains challenging. In this work, we propose an MR-based motion correction method relying on subspace-based real-time MR imaging to estimate motion fields used to correct PET reconstructions. We take advantage of the low-rank characteristics of dynamic MR images to reconstruct high-resolution MR images at high frame rates from highly undersampled k-space data. Reconstructed dynamic MR images are used to determine motion phases for PET reconstruction and estimate phase-to-phase nonrigid motion fields able to capture complex motion patterns such as irregular respiratory and bulk motion. MR-derived binning and motion fields are used for PET reconstruction to generate motion-corrected PET images. The proposed method was evaluated on in vivo data with irregular motion patterns. MR reconstructions accurately captured motion, outperforming state-of-the-art dynamic MR reconstruction techniques. Evaluation of PET reconstructions demonstrated the benefits of the proposed method over standard methods in terms of motion artifact reduction. The proposed method can improve the image quality of motion-corrected PET reconstructions in clinical applications.
△ Less
Submitted 2 October, 2020; v1 submitted 27 August, 2020;
originally announced August 2020.
-
A layered single-side readout DOI TOF-PET detector
Authors:
L. Bläckberg,
S. Sajedi,
G. El Fakhri,
H. Sabet
Abstract:
We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative offset, with inherent DOI information but good timing performance has not been shown with conventional light sharing readout. 2) Single crystal array with one-to…
▽ More
We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative offset, with inherent DOI information but good timing performance has not been shown with conventional light sharing readout. 2) Single crystal array with one-to-one coupling to the photodetector (PD) array, with good timing performance, but no DOI. We believe the combination, where the first layer of a staggered design is coupled one-to-one to a PD array may provide both DOI and timing. The concept is here evaluated through light transport simulations. Results show that: 1) In terms of DOI one-to-one readout of the first layer allows for accurate DOI extraction using a single threshold relative to the PD sum signal, for up to 4 layers. The number of PD pixels exceeding the threshold corresponds to the layer of interaction. The corresponding approach is not possible for the same geometries with a light sharing readout scheme. 2) When employing a low threshold of 2 optical photons the layered approach with one-to-one readout of the first layer improves timing close to the PD compared to single layer, due to reduced crystal thickness. Single detector timing resolution values of 91, 127, 151 and 164 ps were seen in the 4-layer design with unpolished pixels, compared to 148 ps for single array with one-to-one coupling. 3) For the layered design with light sharing readout, timing improves with increased PD pixel size, with an apparent tradeoff between spatial resolution and timing not observed for the one-to-one coupled counterpart. The combination of straightforward and accurate DOI determination, good timing performance and relatively simple design makes the proposed detector a promising candidate for brain dedicated DOI TOF-PET.
△ Less
Submitted 7 July, 2020;
originally announced July 2020.
-
MR-Based PET Attenuation Correction using a Combined Ultrashort Echo Time/Multi-Echo Dixon Acquisition
Authors:
Paul Kyu Han,
Debra E. Horng,
Kuang Gong,
Yoann Petibon,
Kyungsang Kim,
Quanzheng Li,
Keith A. Johnson,
Georges El Fakhri,
Jinsong Ouyang,
Chao Ma
Abstract:
We propose a magnetic resonance (MR)-based method for estimation of continuous linear attenuation coefficients (LAC) in positron emission tomography (PET) using a physical compartmental model and ultrashort echo time (UTE)/multi-echo Dixon (mUTE) acquisitions. Specifically, we propose a three-dimensional (3D) mUTE sequence to acquire signals from water, fat, and short-T2 components (e.g., bones) s…
▽ More
We propose a magnetic resonance (MR)-based method for estimation of continuous linear attenuation coefficients (LAC) in positron emission tomography (PET) using a physical compartmental model and ultrashort echo time (UTE)/multi-echo Dixon (mUTE) acquisitions. Specifically, we propose a three-dimensional (3D) mUTE sequence to acquire signals from water, fat, and short-T2 components (e.g., bones) simultaneously in a single acquisition. The proposed mUTE sequence integrates 3D UTE with multi-echo Dixon acquisitions and uses sparse radial trajectories to accelerate imaging speed. Errors in the radial k-space trajectories are measured using a special k-space trajectory mapping sequence and corrected for image reconstruction. A physical compartmental model is used to fit the measured multi-echo MR signals to obtain fractions of water, fat and bone components for each voxel, which are then used to estimate the continuous LAC map for PET attenuation correction. The performance of the proposed method was evaluated via phantom and in vivo human studies, using LACs from Computed Tomography (CT) as reference. Compared to Dixon- and atlas-based MRAC methods, the proposed method yielded PET images with higher correlation and similarity in relation to the reference. The relative absolute errors of PET activity values reconstructed by the proposed method were below 5% in all of the four lobes (frontal, temporal, parietal, occipital), cerebellum, whole white matter and gray matter regions across all subjects (n=6). The proposed mUTE method can generate subject-specific, continuous LAC map for PET attenuation correction in PET/MR.
△ Less
Submitted 2 April, 2020;
originally announced April 2020.
-
Simulation study of light transport in laser-processed LYSO:Ce detectors with single-side readout
Authors:
Lisa Bläckberg,
Georges El Fakhri,
Hamid Sabet
Abstract:
A tightly focused pulsed laser can locally modify the crystal structure inside the bulk of a scintillator. The result is incorporation of so-called optical barriers with a refractive index (RI) different from that of the crystal bulk, that can be used to redirect the scintillation light and control the light spread in the detector. We systematically study the scintillation light transport in detec…
▽ More
A tightly focused pulsed laser can locally modify the crystal structure inside the bulk of a scintillator. The result is incorporation of so-called optical barriers with a refractive index (RI) different from that of the crystal bulk, that can be used to redirect the scintillation light and control the light spread in the detector. We systematically study the scintillation light transport in detectors fabricated using the Laser Induced Optical Barrier technique, and objectively compare their potential performance characteristics with the two mainstream detector types: monolithic and mechanically pixelated arrays. Among countless optical barrier patterns, we explore barriers arranged in a pixel-like pattern extending all-way or half-way through a 20 mm thick LYSO:Ce crystal. We analyze the performance of the detectors coupled to MPPC arrays, in terms of light response functions, position histograms, line profiles, and light collection efficiency. Our results show that laser-processed detectors constitute a new detector category with a behavior between the two standard detector types. When the barrier-crystal interface is smooth, no DOI information can be obtained regardless of barrier RI. However, with a rough barrier-crystal interface we can extract multiple DOI levels. Lower barrier RI results in larger light confinement, leading to better transverse resolution. Laser-processed crystals can also potentially increase the light collection efficiency, which could lead to improved energy resolution and timing resolution due to higher signals. For a laser-processed detector with smooth barrier-crystal interfaces the light collection efficiency is simulated to >44%, and for rough interfaces >73%. The numbers for a monolithic crystal is 39% with polished surfaces, and 71% with rough surfaces, and for a mechanically pixelated array 33% with polished pixel surfaces and 51% with rough surfaces.
△ Less
Submitted 9 July, 2018;
originally announced July 2018.
-
Attenuation correction for brain PET imaging using deep neural network based on dixon and ZTE MR images
Authors:
Kuang Gong,
Jaewon Yang,
Kyungsang Kim,
Georges El Fakhri,
Youngho Seo,
Quanzheng Li
Abstract:
Positron Emission Tomography (PET) is a functional imaging modality widely used in neuroscience studies. To obtain meaningful quantitative results from PET images, attenuation correction is necessary during image reconstruction. For PET/MR hybrid systems, PET attenuation is challenging as Magnetic Resonance (MR) images do not reflect attenuation coefficients directly. To address this issue, we pre…
▽ More
Positron Emission Tomography (PET) is a functional imaging modality widely used in neuroscience studies. To obtain meaningful quantitative results from PET images, attenuation correction is necessary during image reconstruction. For PET/MR hybrid systems, PET attenuation is challenging as Magnetic Resonance (MR) images do not reflect attenuation coefficients directly. To address this issue, we present deep neural network methods to derive the continuous attenuation coefficients for brain PET imaging from MR images. With only Dixon MR images as the network input, the existing U-net structure was adopted and analysis using forty patient data sets shows it is superior than other Dixon based methods. When both Dixon and zero echo time (ZTE) images are available, we have proposed a modified U-net structure, named GroupU-net, to efficiently make use of both Dixon and ZTE information through group convolution modules when the network goes deeper. Quantitative analysis based on fourteen real patient data sets demonstrates that both network approaches can perform better than the standard methods, and the proposed network structure can further reduce the PET quantification error compared to the U-net structure.
△ Less
Submitted 24 May, 2018; v1 submitted 17 December, 2017;
originally announced December 2017.
-
Iterative PET Image Reconstruction Using Convolutional Neural Network Representation
Authors:
Kuang Gong,
Jiahui Guan,
Kyungsang Kim,
Xuezhu Zhang,
Georges El Fakhri,
Jinyi Qi,
Quanzheng Li
Abstract:
PET image reconstruction is challenging due to the ill-poseness of the inverse problem and limited number of detected photons. Recently deep neural networks have been widely and successfully used in computer vision tasks and attracted growing interests in medical imaging. In this work, we trained a deep residual convolutional neural network to improve PET image quality by using the existing inter-…
▽ More
PET image reconstruction is challenging due to the ill-poseness of the inverse problem and limited number of detected photons. Recently deep neural networks have been widely and successfully used in computer vision tasks and attracted growing interests in medical imaging. In this work, we trained a deep residual convolutional neural network to improve PET image quality by using the existing inter-patient information. An innovative feature of the proposed method is that we embed the neural network in the iterative reconstruction framework for image representation, rather than using it as a post-processing tool. We formulate the objective function as a constraint optimization problem and solve it using the alternating direction method of multipliers (ADMM) algorithm. Both simulation data and hybrid real data are used to evaluate the proposed method. Quantification results show that our proposed iterative neural network method can outperform the neural network denoising and conventional penalized maximum likelihood methods.
△ Less
Submitted 9 October, 2017;
originally announced October 2017.