-
New class of biological detectors for WIMPs
Authors:
Andrzej K. Drukier,
Charles Cantor,
Mark Chonofsky,
George M. Church,
Robert L. Fagaly,
Katherine Freese,
Alejandro Lopez,
Takeshi Sano,
Christopher Savage,
Wesley P. Wong
Abstract:
Weakly Interacting Massive Particles (WIMPs) may constitute a large fraction of the matter in the Universe. There are excess events in the data of DAMA/LIBRA, CoGeNT, CRESST-II, and recently CDMS-Si, which could be consistent with WIMP masses of approximately 10 GeV/c2. However, for MDM > 10 GeV/c2 null results of the CDMS-Ge, XENON, and LUX detectors may be in tension with the potential detection…
▽ More
Weakly Interacting Massive Particles (WIMPs) may constitute a large fraction of the matter in the Universe. There are excess events in the data of DAMA/LIBRA, CoGeNT, CRESST-II, and recently CDMS-Si, which could be consistent with WIMP masses of approximately 10 GeV/c2. However, for MDM > 10 GeV/c2 null results of the CDMS-Ge, XENON, and LUX detectors may be in tension with the potential detections for certain dark matter scenarios and assuming a certain light response.
We propose the use of a new class of biological dark matter (DM) detectors to further examine this light dark matter hypothesis, taking advantage of new signatures with low atomic number targets, Two types of biological DM detectors are discussed here: DNA-based detectors and enzymatic reactions (ER) based detectors. In the case of DNA-based detectors, we discuss a new implementation. In the case of ER detectors, there are four crucial phases of the detection process: a) change of state due to energy deposited by a particle; b) amplification due to the release of energy derived from the action of an enzyme on its substrate; c) sustainable but non-explosive enzymatic reaction; d) self-termination due to the denaturation of the enzyme, when the temperature is raised. This paper provides information of how to design as well as optimize these four processes.
△ Less
Submitted 2 July, 2015; v1 submitted 31 March, 2014;
originally announced March 2014.
-
Development of 2D Bi-SQUID Arrays with High Linearity
Authors:
S. Berggren,
G. Prokopenko,
P. Longhini,
A. Palacios,
O. A. Mukhanov,
A. Leese de Escobar,
B. J. Taylor,
M. C. de Andrade,
M. Nisenoff,
R. L. Fagaly,
T. Wong,
E. Cho,
E. Wong,
V. In
Abstract:
We develop a two-dimensional (2D) Superconducting Quantum Interference Filter (SQIF) array based on recently introduced high-linearity tri-junction bi-SQUIDs. Our bi-SQUID SQIF array design is based on a tight integration of individual bi- SQUID cells sharing inductances with adjacent cells. We provide extensive computer simulations, analysis and experimental measurements, in which we explore the…
▽ More
We develop a two-dimensional (2D) Superconducting Quantum Interference Filter (SQIF) array based on recently introduced high-linearity tri-junction bi-SQUIDs. Our bi-SQUID SQIF array design is based on a tight integration of individual bi- SQUID cells sharing inductances with adjacent cells. We provide extensive computer simulations, analysis and experimental measurements, in which we explore the phase dynamics and linearity of the array voltage response. The non-uniformity in inductances of the bi-SQUIDs produces a pronounced zero-field single antipeak in the voltage response. The anti-peak linearity and size can be optimized by varying the critical current of the additional junction of each bi-SQUID. The layout implementation of the tight 2D array integration leads to a distinct geometrical diamond shape formed by the merged dual bi-SQUID cells. Different size 2D arrays are fabricated using standard HYPRES niobium 4.5 kA/cm2 fabrication process. The measured linearity, power gain, and noise properties will be analyzed for different array sizes and the results will be compared with circuit simulations. We will discuss a design approach for the electrically small magnetic field antenna and low-noise amplifiers with high bandwidth based on these 2D bi-SQUID SQIF arrays. The results from this work will be used to design chips densely and completely covered in bi-SQUIDs that has optimized parameters such as linearity and power gain.
△ Less
Submitted 8 January, 2013;
originally announced January 2013.
-
DC and RF Measurements of Serial Bi-SQUID Arrays
Authors:
G. V. Prokopenko,
O. A. Mukhanov,
A. Leese de Escobar,
B. Taylor,
M. C. de Andrade,
S. Berggren,
P. Longhini,
A. Palacios,
M. Nisenoff,
R. L. Fagaly
Abstract:
SQUID arrays are promising candidates for low profile antennas and low noise amplifier applications. We present the integrated circuit designs and results of DC and RF measurements of the wideband serial arrays based on integration of linear bi-SQUID cells forming a Superconducting Quantum Interference Filter (bi-SQUID SQIF). Various configurations of serial arrays designs are described. The measu…
▽ More
SQUID arrays are promising candidates for low profile antennas and low noise amplifier applications. We present the integrated circuit designs and results of DC and RF measurements of the wideband serial arrays based on integration of linear bi-SQUID cells forming a Superconducting Quantum Interference Filter (bi-SQUID SQIF). Various configurations of serial arrays designs are described. The measured linearity, power gain, and noise temperature are analyzed and compared. The experimental results are matched to results of mathematical modeling. A serial bi-SQUID SQIF arrays are mounted into a coplanar waveguide (CPW) and symmetrically grounded to corresponding sides of CPW. The RF output comes out from the central common line, which is also used for DC biasing and forms a symmetrical balanced output. The signal and DC flux biasing line is designed as coplanar lines passed in parallel over each bi-SQUID cell in a bidirectional fashion concentrating magnetic flux inside of each cell. Serial bi-SQUID SQIF arrays are fabricated on 5 mm x 5 mm chips using standard HYPRES niobium 4.5 kA/cm2 fabrication process.
△ Less
Submitted 15 December, 2012;
originally announced December 2012.