-
Photon shot-noise limited transient absorption soft X-ray spectroscopy at the European XFEL
Authors:
Loïc Le Guyader,
Andrea Eschenlohr,
Martin Beye,
William Schlotter,
Florian Döring,
Cammille Carinan,
David Hickin,
Naman Agarwal,
Christine Boeglin,
Uwe Bovensiepen,
Jens Buck,
Robert Carley,
Andrea Castoldi,
Alessandro D'Elia,
Jan-Torben Delitz,
Wajid Ehsan,
Robin Engel,
Florian Erdinger,
Hans Fangohr,
Peter Fischer,
Carlo Fiorini,
Alexander Föhlisch,
Luca Gelisio,
Michael Gensch,
Natalia Gerasimova
, et al. (39 additional authors not shown)
Abstract:
Femtosecond transient soft X-ray Absorption Spectroscopy (XAS) is a very promising technique that can be employed at X-ray Free Electron Lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here we present a dedicated setup for soft X-rays available at the Spectroscopy & Coherent Scattering (SCS) instrument at the European X-ray Free Electron Laser (EuXFEL). I…
▽ More
Femtosecond transient soft X-ray Absorption Spectroscopy (XAS) is a very promising technique that can be employed at X-ray Free Electron Lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here we present a dedicated setup for soft X-rays available at the Spectroscopy & Coherent Scattering (SCS) instrument at the European X-ray Free Electron Laser (EuXFEL). It consists of a beam-splitting off-axis zone plate (BOZ) used in transmission to create three copies of the incoming beam, which are used to measure the transmitted intensity through the excited and unexcited sample, as well as to monitor the incoming intensity. Since these three intensity signals are detected shot-by-shot and simultaneously, this setup allows normalized shot-by-shot analysis of the transmission. For photon detection, the DSSC imaging detector, which is capable of recording up to 800 images at 4.5 MHz frame rate during the FEL burst, is employed and allows approaching the photon shot-noise limit. We review the setup and its capabilities, as well as the online and offline analysis tools provided to users.
△ Less
Submitted 4 January, 2023; v1 submitted 8 November, 2022;
originally announced November 2022.
-
The CoESCA station at BESSY: Auger electron-Photoelectron coincidences from surfaces demonstrated for Ag MNN
Authors:
T. Leitner,
A. Born,
I. Bidermane,
R. Ovsyannikov,
F. O. L. Johansson,
Y. Sassa,
A. Föhlisch,
A. Lindblad,
F. O. Schumann,
S. Svensson,
N. Mårtensson
Abstract:
In this work, we present the CoESCA station for electron-electron coincidence spectroscopy from surfaces, built in a close collaboration between Uppsala University and Helmholtz-Zentrum Berlin at the BESSY II synchrotron facility in Berlin, Germany. We start with a detailed overview of previous work in the field of electron-electron coincidences, before we describe the CoESCA setup and its design…
▽ More
In this work, we present the CoESCA station for electron-electron coincidence spectroscopy from surfaces, built in a close collaboration between Uppsala University and Helmholtz-Zentrum Berlin at the BESSY II synchrotron facility in Berlin, Germany. We start with a detailed overview of previous work in the field of electron-electron coincidences, before we describe the CoESCA setup and its design parameters. The system is capable of recording shot-to-shot resolved 6D coincidence datasets, i.e. the kinetic energy and the two take off angles for both coincident electrons. The mathematics behind extracting and analysing these multi-dimensional coincidence datasets is introduced, with a focus on coincidence statistics, resulting in fundamental limits of the signal-to-noise ratio and its implications for acquisition times and the size of the raw data stream. The functionality of the CoESCA station is demonstrated for the example of Auger electron - photoelectron coincidences from silver surfaces for photoelectrons from the Ag 3d core levels and their corresponding MNN Auger electrons. The Auger spectra originating from the different core levels, 3d$_{3/2}$ and 3d$_{5/2}$ could be separated and further, the two-hole state energy distributions were determined for these Auger decay channels.
△ Less
Submitted 17 December, 2020;
originally announced December 2020.
-
Resonant Auger spectroscopy at the L2,3 shake-up thresholds as a probe of electron correlation effects in nickel
Authors:
M. Magnuson,
N. Wassdahl,
A. Nilsson,
A. Föhlisch,
J. Nordgren,
N. Mårtensson
Abstract:
The excitation energy dependence of the three-hole satellites in the L3-M4,5M4,5 and L2-M4,5M4,5 Auger spectra of nickel metal has been measured using synchrotron radiation. The satellite behavior in the non-radiative emission spectra at the L3 and L2 thresholds is compared and the influence of the Coster-Kronig channel explored. The three-hole satellite intensity at the L3 Auger emission line rev…
▽ More
The excitation energy dependence of the three-hole satellites in the L3-M4,5M4,5 and L2-M4,5M4,5 Auger spectra of nickel metal has been measured using synchrotron radiation. The satellite behavior in the non-radiative emission spectra at the L3 and L2 thresholds is compared and the influence of the Coster-Kronig channel explored. The three-hole satellite intensity at the L3 Auger emission line reveals a peak structure at 5 eV above the L3 threshold attributed to resonant processes at the 2p53d9 shake-up threshold. This is discussed in connection with the 6-eV feature in the x-ray absorption spectrum.
△ Less
Submitted 29 December, 2011; v1 submitted 5 December, 2011;
originally announced December 2011.