-
Observation of narrow-band $γ$ radiation from a boron-doped diamond superlattice with an 855 MeV electron beam
Authors:
Hartmut Backe,
José Baruchel,
Simon Bénichou,
Rébecca Dowek,
David Eon,
Pierre Everaere,
Lutz Kirste,
Pascal Klag,
Werner Lauth,
Patrik Straňák,
Thu Nhi Tran Caliste
Abstract:
A diamond superlattice with a period length of 3.54 $μ$m was grown on a high quality straight (100) diamond plate with the method of Chemical Vapour Deposition (CVD). A sinusoidal varying boron doping profile resulted in a periodic variation of the lattice constant, and in turn four sinusoidally deformed (110) planes with a period length of 5.0 $μ$m and an amplitude of 0.138 nm. A channeling exper…
▽ More
A diamond superlattice with a period length of 3.54 $μ$m was grown on a high quality straight (100) diamond plate with the method of Chemical Vapour Deposition (CVD). A sinusoidal varying boron doping profile resulted in a periodic variation of the lattice constant, and in turn four sinusoidally deformed (110) planes with a period length of 5.0 $μ$m and an amplitude of 0.138 nm. A channeling experiment was performed with the 855 MeV electron beam of the Mainz Microtron MAMI accelerator facility. Part of the impinging electrons perform sinusoidal oscillations resulting in the emission of quasi-monochromatic $γ$ radiation. A clear peak was observed with a large sodium iodide scintillation detector close to the expected photon energy of 1.33 MeV. Gross properties like photon energy, width and intensity of the peak can be reproduced fairly well by idealized Monte-Carlo simulation calculations. Based on the latter, prospects of applying such $γ$ radiation sources are addressed with the example of the photonuclear reaction $^{100}$Mo($γ$,n)$^{99}$Mo at 14.3 MeV to produce the medical important $^{99m}$Tc isotope.
△ Less
Submitted 27 May, 2025; v1 submitted 24 April, 2025;
originally announced April 2025.
-
Performance of CVD diamond detectors for single ion beam-tagging applications in hadrontherapy monitoring
Authors:
Sébastien Curtoni,
Marie-Laure Gallin-Martel,
Sara Marcatili,
Latifa Abbassi,
Alexandre Bes,
Germain Bosson,
Johann Collot,
Thierry Crozes,
Denis Dauvergne,
Wout De Nolf,
Pierre Everaere,
Laurent Gallin-Martel,
Abderrahmane Ghimouz,
Ferid Haddad,
Christophe Hoarau,
Jean-Yves Hostachy,
Charbel Koumeir,
Ana Lacoste,
Vincent Métivier,
John Morse,
Jean-François Motte,
Jean-François Muraz,
Freddy Poirier,
Fatah Ellah Rarbi,
Olivier Rossetto
, et al. (4 additional authors not shown)
Abstract:
In the context of online ion range verification in particle therapy, the CLaRyS collaboration is developing Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improv…
▽ More
In the context of online ion range verification in particle therapy, the CLaRyS collaboration is developing Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improved by detecting single ions with a 100 ps ($σ$) time resolution, through a quality assurance procedure at low beam intensity at the beginning of the treatment session. This work presents the investigations led to assess the performance of Chemical Vapor Deposition (CVD) diamond detectors to fulfill these requirements. A $^{90}$Sr beta source, 68 MeV protons, 95 MeV/u carbon ions and a synchrotron X-ray pulsed beam were used to measure the time resolution, single ion detection efficiency and proton counting capability of various CVD diamond samples. An offline technique, based on double-sided readout with fast current preamplifiers and used to improve the signal-to-noise ratio, is also presented. The different tests highlighted Time-Of-Flight resolutions ranging from 13 ps ($σ$) to 250 ps ($σ$), depending on the experimental conditions. The single 68 MeV proton detection efficiency of various large area polycrystalline (pCVD) samples was measured to be $>$96% using coincidence measurements with a single-crystal reference detector. Single-crystal CVD (sCVD) diamond proved to be able to count a discrete number of simultaneous protons while it was not achievable with a polycrystalline sample. Considering the results of the present study, two diamond hodoscope demonstrators are under development: one based on sCVD, and one of larger size based on pCVD. They will be used for the purpose of single ion as well as ion bunches detection, either at reduced or clinical beam intensities.
△ Less
Submitted 23 August, 2021; v1 submitted 11 May, 2021;
originally announced May 2021.
-
RF pulse amplifier for CVD-diamond particle detectors
Authors:
C. Hoarau,
G. Bosson,
J. -L. Bouly,
S. Curtoni,
D. Dauvergne,
P. Everaere,
M. -L. Gallin-Martel,
S. Marcatili,
J. -F. Muraz,
A. Portier,
N. Rosuel
Abstract:
This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stamping, with prerequisite of fast electro…
▽ More
This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stamping, with prerequisite of fast electronics. The LNA is designed with surface mounted components and RF layout techniques to control costs and to allow timing performance suitable for sub-nanosecond edges of pulses. Also this amplifier offers the possibility of high voltage biasing, a characteristic essential for driving diamond detectors. Finally the greatest asset of this study is certainly the minimization of the power consumption, which allows us to consider designs with multiple amplifiers, in limited space, for striped diamond detectors.
△ Less
Submitted 22 February, 2021;
originally announced February 2021.