-
Satellites in the Ti~1$s$ core level spectra of SrTiO$_3$ and TiO$_2$
Authors:
Atsushi Hariki,
Keisuke Higashi,
Tatsuya Yamaguchi,
Jiebin Li,
Curran Kalha,
Manfred Mascheck,
Susanna K. Eriksson,
Tomas Wiell,
Frank M. F. de Groot,
Anna Regoutz
Abstract:
Satellites in core level spectra of photoelectron spectroscopy (PES) can provide crucial information on the electronic structure and chemical bonding in materials, particular in transition metal oxides. This paper explores satellites of the Ti 1$s$ and 2$p$ core level spectra of SrTiO$_3$ and TiO$_2$. Conventionally, soft x-ray PES (SXPS) probes the Ti 2$p$ core level; however, it is not ideal to…
▽ More
Satellites in core level spectra of photoelectron spectroscopy (PES) can provide crucial information on the electronic structure and chemical bonding in materials, particular in transition metal oxides. This paper explores satellites of the Ti 1$s$ and 2$p$ core level spectra of SrTiO$_3$ and TiO$_2$. Conventionally, soft x-ray PES (SXPS) probes the Ti 2$p$ core level; however, it is not ideal to fully capture satellite features due to its inherent spin-orbit-splitting (SOS). Here, hard x-ray PES(HAXPES) provides access to the Ti 1$s$ spectrum instead, which allows us to study intrinsic charge responses upon core-hole creation without the complication from SOS and with favorable intrinsic linewidths. The experimental spectra are theoretically analyzed by two impurity models, including an Anderson impurity model (AIM) built on local density approximation (LDA) and dynamical mean-field theory (DMFT), and a conventional TiO$_6$ cluster model. The theoretical results emphasize the importance of explicit inclusion of higher-order Ti-O charge-transfer processes beyond the nearest-neighboring Ti-O bond to simulate the core level spectra of SrTiO$_3$ and TiO$_2$. The AIM approach with continuous bath orbitals provided by LDA+DMFT represents the experimental spectra well. Crucially, with the aid of the LDA+DMFT method, this paper provides a robust prescription of how to use the computationally cheap cluster model in fitting analyses of core level spectra.
△ Less
Submitted 6 January, 2023; v1 submitted 17 June, 2022;
originally announced June 2022.
-
Give quantum mechanics a chance: use relativistic quantum mechanics to analyze measurement!
Authors:
Karl-Erik Eriksson
Abstract:
At the time of publication of H. Everett's Relative-State Formulation (1957) and DeWitt's Many-Worlds Interpretation (1970), quantum mechanics was available in a more modern and adequate version than the one used by these authors. We show that with the more modern quantum theory, quantum measurement could have been analyzed along more conventional lines in a one-world cosmology. Bell criticized th…
▽ More
At the time of publication of H. Everett's Relative-State Formulation (1957) and DeWitt's Many-Worlds Interpretation (1970), quantum mechanics was available in a more modern and adequate version than the one used by these authors. We show that with the more modern quantum theory, quantum measurement could have been analyzed along more conventional lines in a one-world cosmology. Bell criticized the Everett-DeWitt theory quite sharply in 1987 but this seems not to have affected the acceptance of the old quantum mechanics as the framework for analysis of measurement.
△ Less
Submitted 14 July, 2021; v1 submitted 14 June, 2021;
originally announced June 2021.
-
On the Interplay between Robustness and Dynamic Planning for Adaptive Radiation Therapy
Authors:
Michelle Böck,
Kjell Eriksson,
Anders Forsgren
Abstract:
Interfractional geometric uncertainties can lead to deviations of the actual delivered dose from the prescribed dose distribution. To better handle these uncertainties during treatment, the authors propose a dynamic framework for robust adaptive radiation therapy in which a variety of robust adaptive treatment strategies are introduced and evaluated. This variety is a result of optimization variab…
▽ More
Interfractional geometric uncertainties can lead to deviations of the actual delivered dose from the prescribed dose distribution. To better handle these uncertainties during treatment, the authors propose a dynamic framework for robust adaptive radiation therapy in which a variety of robust adaptive treatment strategies are introduced and evaluated. This variety is a result of optimization variables with various degrees of freedom within robust optimization models that vary in their grade of conservativeness. We formulate an adaptive framework with dependence on time and/or uncertainty or neither. The framework is evaluated with either expected-value-, worst-case-, or conditional-value-at-risk-(CVaR)-optimization. The goal of this study is to identify the mathematical properties of the proposed robust adaptive strategies in order to restore the planned dose distribution. We apply a result from convex analysis to show that in our framework, the time-dependent problem has a time-independent optimal solution. This implies that the time-dependent problem can be solved by dynamically solving the corresponding time-independent problem. This is especially relevant in a clinical context, since it implies that adaptive radiation therapy can be implemented in clinical practice using commercially available treatment planning systems. We demonstrate that time-and-scenario-dependent variables are most compatible with worst-case-optimization and that including dose prediction potentially improves treatment compared to non-adaptive planning. Contrarily, time-and-scenario-independent variables appear most compatible with expected-value-optimization. Non-adaptive robust strategies may provide sufficient target coverage, comparable to robust adaptive strategies, if the occurring uncertainties follow the same distribution as those included in the robust model.
△ Less
Submitted 1 November, 2018;
originally announced November 2018.
-
Increased accuracy of planning tools for optimization of dynamic multileaf collimator delivery of radiotherapy through reformulated objective functions
Authors:
Lovisa Engberg,
Kjell Eriksson,
Anders Forsgren
Abstract:
The purpose of this study is to examine in a clinical setting a novel formulation of objective functions for intensity-modulated radiotherapy treatment plan multicriteria optimization (MCO) that we suggested in a recent study. The proposed objective functions are extended with dynamic multileaf collimator (DMLC) delivery constraints from the literature, and a tailored interior point method is desc…
▽ More
The purpose of this study is to examine in a clinical setting a novel formulation of objective functions for intensity-modulated radiotherapy treatment plan multicriteria optimization (MCO) that we suggested in a recent study. The proposed objective functions are extended with dynamic multileaf collimator (DMLC) delivery constraints from the literature, and a tailored interior point method is described to efficiently solve the resulting optimization formulation. In a numerical planning study involving three patient cases, DMLC plans Pareto optimal to the MCO formulation with the proposed objective functions are generated. Evaluated based on pre-defined plan quality indices, these DMLC plans are compared to conventionally generated DMLC plans. Comparable or superior plan quality is observed. Supported by these results, the proposed objective functions are argued to have a potential to streamline the planning process, since they are designed to overcome the methodological shortcomings associated with the conventional penalty-based objective functions assumed to cause the current need for time-consuming trial-and-error parameter tuning. In particular, the increased accuracy of the planning tools imposed by the proposed objective functions has the potential to make the planning process less complicated. These conclusions position the proposed formulation as an alternative to existing methods for automated planning.
△ Less
Submitted 23 October, 2018; v1 submitted 2 February, 2018;
originally announced February 2018.
-
Explicit optimization of plan quality measures in intensity-modulated radiation therapy treatment planning
Authors:
Lovisa Engberg,
Kjell Eriksson,
Anders Forsgren,
Björn Hårdemark
Abstract:
Conventional planning objectives in optimization of intensity-modulated radiotherapy treatment (IMRT) plans are designed to minimize the violation of dose-volume histogram (DVH) thresholds using penalty functions. Although successful in guiding the DVH curve towards these thresholds, conventional planning objectives offer limited control of the individual points on the DVH curve (doses-at-volume)…
▽ More
Conventional planning objectives in optimization of intensity-modulated radiotherapy treatment (IMRT) plans are designed to minimize the violation of dose-volume histogram (DVH) thresholds using penalty functions. Although successful in guiding the DVH curve towards these thresholds, conventional planning objectives offer limited control of the individual points on the DVH curve (doses-at-volume) used to evaluate plan quality. In this study, we abandon the usual penalty-function framework and propose planning objectives that more explicitly relate to DVH statistics. The proposed planning objectives are based on mean-tail-dose, resulting in convex optimization. We also demonstrate how to adapt a standard optimization method to the proposed formulation in order to obtain a substantial reduction in computational cost.
We investigate the potential of the proposed planning objectives as tools for optimizing DVH statistics through juxtaposition with the conventional planning objectives on two patient cases. Sets of treatment plans with differently balanced planning objectives are generated using either the proposed or the conventional approach. Dominance in the sense of better distributed doses-at-volume is observed in plans optimized within the proposed framework, indicating that the DVH statistics are better optimized and more efficiently balanced using the proposed planning objectives.
△ Less
Submitted 25 January, 2017; v1 submitted 5 July, 2016;
originally announced July 2016.