Optimized thermoelectric sensitivity measurement for differential thermometry with thermopiles
Authors:
Tim Prangemeier,
Iman Nejati,
Andreas Müller,
Philip Endres,
Mario Fratzl,
Mathias Dietzel
Abstract:
A novel approach to calibrate the sensitivity of a differential thermometer, consisting of several thermocouples connected in series (thermopile), has been developed. The goal of this method is to increase the accuracy of small temperature difference measurements ($ΔT \leq 1\:\textrm{K}$), without invoking higher sensor complexity. To this end, a method to determine the optimal temperature differe…
▽ More
A novel approach to calibrate the sensitivity of a differential thermometer, consisting of several thermocouples connected in series (thermopile), has been developed. The goal of this method is to increase the accuracy of small temperature difference measurements ($ΔT \leq 1\:\textrm{K}$), without invoking higher sensor complexity. To this end, a method to determine the optimal temperature difference employed during the differential measurement of thermoelectric sensitivities has been developed. This calibration temperature difference is found at the minimum of combined measurement and linearization error for a given mean temperature. The developed procedure is demonstrated in an illustrative example calibration of a nine-junction thermopile. For mean temperatures between $-10\:^{o}\textrm{C}$ and $15\:^{o}\textrm{C}$, the thermoelectric sensitivity was measured with an uncertainty of less than $\pm 2\:\%$. Subsequently, temperature differences as low as $10^{-2}\:\textrm{K}$ can be resolved, while the thermometer used for the example calibration was accurate only to $\pm 0.3\:\textrm{K}$. This and higher degrees of accuracy are required in certain research applications, for example to detect heat flux modulations in bifurcating fluidic systems.
△ Less
Submitted 27 April, 2017;
originally announced April 2017.
The CDMS view on molecular data needs of Herschel, SOFIA, and ALMA
Authors:
Holger S P Müller,
C P Endres,
J Stutzki,
S Schlemmer
Abstract:
The catalog section of the Cologne Database for Molecular Spectroscopy, CDMS, contains mostly rotational transition frequencies, with auxiliary information, of molecules observable in space. The frequency lists are generated mostly from critically evaluated laboratory data employing established Hamiltonian models. The CDMS has been online publicly for more than 12 years, e.g., via the short-cut ht…
▽ More
The catalog section of the Cologne Database for Molecular Spectroscopy, CDMS, contains mostly rotational transition frequencies, with auxiliary information, of molecules observable in space. The frequency lists are generated mostly from critically evaluated laboratory data employing established Hamiltonian models. The CDMS has been online publicly for more than 12 years, e.g., via the short-cut http://www.cdms.de. Initially constructed as ascii tables, its inclusion into a database environment within the Virtual Atomic and Molecular Data Centre (VAMDC, http://www.vamdc.eu) has begun in June 2008. A test version of the new CDMS is about to be released. The CDMS activities have been part of the extensive laboratory spectroscopic investigations in Cologne. Moreover, these activities have also benefit from collaborations with other laboratory spectroscopy groups as well as with astronomers. We will provide some basic information on the CDMS and its participation in the VAMDC project. In addition, some recent detections of molecules as well as spectroscopic studies will be discussed to evaluate the spectroscopic data needs of Herschel, SOFIA, and ALMA in particular in terms of light hydrides, complex molecules, and metal containing species
△ Less
Submitted 6 April, 2013;
originally announced April 2013.