-
Virtual H&E Histology by Fiber-Based Picosecond Two-Photon Microscopy
Authors:
Jan Philip Kolb,
Daniel Weng,
Hubertus Hakert,
Matthias Eibl,
Wolfgang Draxinger,
Tobias Meyer,
Thomas Gottschall,
Ralf Brinkmann,
Reginald Bringruber,
Jürgen Popp,
Jens Limpert,
Sebastian Nino Karpf,
Robert Huber
Abstract:
Two-Photon Microscopy (TPM) can provide three-dimensional morphological and functional contrast in vivo. Through proper staining, TPM can be utilized to create virtual, H&E equivalent images and thus can improve throughput in histology-based applications. We previously reported on a new light source for TPM that employs a compact and robust fiber-amplified, directly modulated laser. This laser is…
▽ More
Two-Photon Microscopy (TPM) can provide three-dimensional morphological and functional contrast in vivo. Through proper staining, TPM can be utilized to create virtual, H&E equivalent images and thus can improve throughput in histology-based applications. We previously reported on a new light source for TPM that employs a compact and robust fiber-amplified, directly modulated laser. This laser is pulse-to-pulse wavelength switchable between 1064 nm, 1122 nm, and 1186 nm with an adjustable pulse duration from 50ps to 5ns and arbitrary repetition rates up to 1MHz at kW-peak powers. Despite the longer pulse duration, it can achieve similar average signal levels compared to fs-setups by lowering the repetition rate to achieve similar cw and peak power levels. The longer pulses lead to a larger number of photons per pulse, which yields single shot fluorescence lifetime measurements (FLIM) by applying a fast 4 GSamples/s digitizer. In the previous setup, the wavelengths were limited to 1064 nm and longer. Here, we use four wave mixing in a non-linear photonic crystal fiber to expand the wavelength range down to 940 nm. This wavelength is highly suitable for imaging green fluorescent proteins in neurosciences and stains such as acridine orange (AO), eosin yellow (EY) and sulforhodamine 101 (SR101) used for histology applications. In a more compact setup, we also show virtual H&E histological imaging using a direct 1030 nm fiber MOPA.
△ Less
Submitted 11 August, 2020;
originally announced August 2020.
-
Wavelength agile multi-photon microscopy with a fiber amplified diode laser
Authors:
Matthias Eibl,
Daniel Weng,
Hubertus Hakert,
Jan Philip Kolb,
Tom Pfeiffer,
Jennifer E. Hundt,
Robert Huber,
Sebastian Karpf
Abstract:
Multi-photon microscopy is a powerful tool in biomolecular research. Less complex and more cost effective excitation light sources will make this technique accessible to a broader community. Especially semiconductor diode seeded fiber lasers have proven to be robust, low cost and easy to use. However, their wavelength tuning range is often limited, so only a limited number of fluorophores can be a…
▽ More
Multi-photon microscopy is a powerful tool in biomolecular research. Less complex and more cost effective excitation light sources will make this technique accessible to a broader community. Especially semiconductor diode seeded fiber lasers have proven to be robust, low cost and easy to use. However, their wavelength tuning range is often limited, so only a limited number of fluorophores can be accessed. Therefore, different approaches have been proposed to extend the spectral coverage of these lasers. Recently, we showed that four-wave mixing (FWM) assisted stimulated Raman scattering (SRS) can be harnessed to red-shift high power pulses from 1064 nm to a narrowband output at 1122 nm and 1186 nm and therefore extend the number of accessible fluorophores. In this contribution, we show the applicability of all three wavelengths for multi-photon microscopy and analyze the performance.
△ Less
Submitted 1 November, 2018; v1 submitted 30 October, 2018;
originally announced October 2018.
-
Two-photon-excited fluorescence (TPEF) and fluorescence lifetime imaging (FLIM) with sub-nanosecond pulses and a high analog bandwidth signal detection
Authors:
Matthias Eibl,
Sebastian Karpf,
Hubertus Hakert,
Daniel Weng,
Robert Huber
Abstract:
Two-photon excited fluorescence (TPEF) microscopy and fluorescence lifetime imaging (FLIM) are powerful imaging techniques in bio-molecular science. The need for elaborate light sources for TPEF and speed limitations for FLIM, however, hinder an even wider application. We present a way to overcome this limitations by combining a robust and inexpensive fiber laser for nonlinear excitation with a fa…
▽ More
Two-photon excited fluorescence (TPEF) microscopy and fluorescence lifetime imaging (FLIM) are powerful imaging techniques in bio-molecular science. The need for elaborate light sources for TPEF and speed limitations for FLIM, however, hinder an even wider application. We present a way to overcome this limitations by combining a robust and inexpensive fiber laser for nonlinear excitation with a fast analog digitization method for rapid FLIM imaging. The applied sub nanosecond pulsed laser source is synchronized to a high analog bandwidth signal detection for single shot TPEF- and single shot FLIM imaging. The actively modulated pulses at 1064nm from the fiber laser are adjustable from 50ps to 5ns with kW of peak power. At a typically applied pulse lengths and repetition rates, the duty cycle is comparable to typically used femtosecond pulses and thus the peak power is also comparable at same cw-power. Hence, both types of excitation should yield the same number of fluorescence photons per time on average when used for TPEF imaging. However, in the 100ps configuration, a thousand times more fluorescence photons are generated per pulse. In this paper, we now show that the higher number of fluorescence photons per pulse combined with a high analog bandwidth detection makes it possible to not only use a single pulse per pixel for TPEF imaging but also to resolve the exponential time decay for FLIM. To evaluate the performance of our system, we acquired FLIM images of a Convallaria sample with pixel rates of 1 MHz where the lifetime information is directly measured with a fast real time digitizer. With the presented results, we show that longer pulses in the many-10ps to nanosecond regime can be readily applied for TPEF imaging and enable new imaging modalities like single pulse FLIM.
△ Less
Submitted 11 October, 2018;
originally announced October 2018.
-
Pulse-to-pulse wavelength switchting of diode based fiber laser for multi-color multi-photon imaging
Authors:
Matthias Eibl,
Sebastian Karpf,
Hubertus Hakert,
Daniel Weng,
Torben Blömker,
Robert Huber
Abstract:
We present an entirely fiber based laser source for non-linear imaging with a novel approach for multi-color excitation. The high power output of an actively modulated and amplified picosecond fiber laser at 1064 nm is shifted to longer wavelengths by a combination of four-wave mixing and stimulated Raman scattering. By combining different fiber types and lengths, we control the non-linear wavelen…
▽ More
We present an entirely fiber based laser source for non-linear imaging with a novel approach for multi-color excitation. The high power output of an actively modulated and amplified picosecond fiber laser at 1064 nm is shifted to longer wavelengths by a combination of four-wave mixing and stimulated Raman scattering. By combining different fiber types and lengths, we control the non-linear wavelength conversion in the delivery fiber itself and can switch between 1064 nm, 1122 nm, and 1186 nm on-the-fly by tuning the pump power of the fiber amplifier and modulate the seed diodes. This is a promising way to enhance the applicability of short pulsed laser diodes for bio-molecular non-linear imaging by reducing the spectral limitations of such sources. In comparison to our previous work [1, 2], we show for the first time two-photon imaging with the shifted wavelengths and we demonstrate pulse-to-pulse switching between the different wavelengths without changing the configuration.
△ Less
Submitted 11 October, 2018;
originally announced October 2018.
-
Shot-Noise limited Time-encoded (TICO) Raman spectroscopy
Authors:
Sebastian Karpf,
Matthias Eibl,
Wolfgang Wieser,
Thomas Klein,
Robert Huber
Abstract:
Raman scattering, an inelastic scattering mechanism, provides information about molecular excitation energies and can be used to identify chemical compounds. Albeit being a powerful analysis tool, especially for label-free biomedical imaging with molecular contrast, it suffers from inherently low signal levels. This practical limitation can be overcome by non-linear enhancement techniques like sti…
▽ More
Raman scattering, an inelastic scattering mechanism, provides information about molecular excitation energies and can be used to identify chemical compounds. Albeit being a powerful analysis tool, especially for label-free biomedical imaging with molecular contrast, it suffers from inherently low signal levels. This practical limitation can be overcome by non-linear enhancement techniques like stimulated Raman scattering (SRS). In SRS, an additional light source stimulates the Raman scattering process. This can lead to orders of magnitude increase in signal levels and hence faster acquisition in biomedical imaging. However, achieving a broad spectral coverage in SRS is technically challenging and the signal is no longer background-free, as either stimulated Raman gain (SRG) or loss (SRL) is measured, turning a sensitivity limit into a dynamic range limit. Thus, the signal has to be isolated from the laser background light, requiring elaborate methods for minimizing detection noise. Here we analyze the detection sensitivity of a shot-noise limited broadband stimulated time-encoded Raman (TICO-Raman) system in detail. In time-encoded Raman, a wavelength-swept Fourier Domain Mode Locked (FDML) laser covers a broad range of Raman transition energies while allowing a dual-balanced detection for lowering the detection noise to the fundamental shot-noise limit.
△ Less
Submitted 11 October, 2018;
originally announced October 2018.
-
Flexible A-scan rate MHz OCT: Computational downscaling by coherent averaging
Authors:
Tom Pfeiffer,
Wolfgang Wieser,
Thomas Klein,
Markus Petermann,
Jan-Phillip Kolb,
Matthias Eibl,
Robert Huber
Abstract:
In order to realize fast OCT-systems with adjustable line rate, we investigate averaging of image data from an FDML based MHz-OCT-system. The line rate can be reduced in software and traded in for increased system sensitivity and image quality. We compare coherent and incoherent averaging to effectively scale down the system speed of a 3.2 MHz FDML OCT system to around 100 kHz in postprocessing. W…
▽ More
In order to realize fast OCT-systems with adjustable line rate, we investigate averaging of image data from an FDML based MHz-OCT-system. The line rate can be reduced in software and traded in for increased system sensitivity and image quality. We compare coherent and incoherent averaging to effectively scale down the system speed of a 3.2 MHz FDML OCT system to around 100 kHz in postprocessing. We demonstrate that coherent averaging is possible with MHz systems without special interferometer designs or digital phase stabilisation. We show OCT images of a human finger knuckle joint in vivo with very high quality and deep penetration.
△ Less
Submitted 19 July, 2016;
originally announced July 2016.
-
Megahertz FDML Laser with up to 143nm Sweep Range for Ultrahigh Resolution OCT at 1050nm
Authors:
Jan Philip Kolb,
Thomas Klein,
Mattias Eibl,
Tom Pfeiffer,
Wolfgang Wieser,
Robert Huber
Abstract:
We present a new design of a Fourier Domain Mode Locked laser (FDML laser), which provides a new record in sweep range at ~1um center wavelength: At the fundamental sweep rate of 2x417 kHz we reach 143nm bandwidth and 120nm with 4x buffering at 1.67MHz sweep rate. The latter configuration of our system is characterized: The FWHM of the point spread function (PSF) of a mirror is 5.6um (in tissue).…
▽ More
We present a new design of a Fourier Domain Mode Locked laser (FDML laser), which provides a new record in sweep range at ~1um center wavelength: At the fundamental sweep rate of 2x417 kHz we reach 143nm bandwidth and 120nm with 4x buffering at 1.67MHz sweep rate. The latter configuration of our system is characterized: The FWHM of the point spread function (PSF) of a mirror is 5.6um (in tissue). Human in vivo retinal imaging is performed with the MHz laser showing more details in vascular structures. Here we could measure an axial resolution of 6.0um by determining the FWHM of specular reflex in the image. Additionally, challenges related to such a high sweep bandwidth such as water absorption are investigated.
△ Less
Submitted 19 July, 2016;
originally announced July 2016.
-
Time-Encoded Raman: Fiber-based, hyperspectral, broadband stimulated Raman microscopy
Authors:
Sebastian Karpf,
Matthias Eibl,
Wolfgang Wieser,
Thomas Klein,
Robert Huber
Abstract:
Raman sensing and Raman microscopy are amongst the most specific optical technologies to identify the chemical compounds of unknown samples, and to enable label-free biomedical imaging with molecular contrast. However, the high cost and complexity, low speed, and incomplete spectral information provided by current technology are major challenges preventing more widespread application of Raman syst…
▽ More
Raman sensing and Raman microscopy are amongst the most specific optical technologies to identify the chemical compounds of unknown samples, and to enable label-free biomedical imaging with molecular contrast. However, the high cost and complexity, low speed, and incomplete spectral information provided by current technology are major challenges preventing more widespread application of Raman systems. To overcome these limitations, we developed a new method for stimulated Raman spectroscopy and Raman imaging using continuous wave (CW), rapidly wavelength swept lasers. Our all-fiber, time-encoded Raman (TICO-Raman) setup uses a Fourier Domain Mode Locked (FDML) laser source to achieve a unique combination of high speed, broad spectral coverage (750 cm-1 - 3150 cm-1) and high resolution (0.5 cm-1). The Raman information is directly encoded and acquired in time. We demonstrate quantitative chemical analysis of a solvent mixture and hyperspectral Raman microscopy with molecular contrast of plant cells.
△ Less
Submitted 16 May, 2014;
originally announced May 2014.