The Qweak High Performance LH2 Target
Authors:
J. Brock,
S. Covrig Dusa,
J. Dunne,
C. Keith,
D. Meekins,
J. Pierce,
G. R. Smith,
A. Subedi
Abstract:
A high-power liquid hydrogen target was built for the Jefferson Lab Qweak experiment, which measured the tiny parity-violating asymmetry in $\vec{e}$p scattering at an incident energy of 1.16 GeV, and a Q$^2 = 0.025$ GeV$^{2}$. To achieve the luminosity of $1.7 \times 10^{39}$ cm$^{-2}$ s$^{-1}$, a 34.5 cm-long target was used with a beam current of 180 $μ$A. The ionization energy-loss deposited b…
▽ More
A high-power liquid hydrogen target was built for the Jefferson Lab Qweak experiment, which measured the tiny parity-violating asymmetry in $\vec{e}$p scattering at an incident energy of 1.16 GeV, and a Q$^2 = 0.025$ GeV$^{2}$. To achieve the luminosity of $1.7 \times 10^{39}$ cm$^{-2}$ s$^{-1}$, a 34.5 cm-long target was used with a beam current of 180 $μ$A. The ionization energy-loss deposited by the beam in the target was 2.1 kW. The target temperature was controlled to within $\pm$0.02 K and the target noise (density fluctuations) near the experiment's beam helicity-reversal rate of 960 Hz was only 53 ppm. The 58 liquid liter target achieved a head of 11.4 m (7.6 kPa) and a mass flow of 1.2 $\pm$ 0.3 kg/s (corresponding to a volume flow of 17.4 $\pm$ 3.8 l/s) at the nominal 29 Hz rotation frequency of the recirculating centrifugal pump. We describe aspects of the design, operation, and performance of this target, the highest power LH2 target ever used in an electron scattering experiment to date.
△ Less
Submitted 13 March, 2023;
originally announced March 2023.
-
The Solenoidal Large Intensity Device (SoLID) for JLab 12 GeV
Authors:
John Arrington,
Jay Benesch,
Alexandre Camsonne,
Jimmy Caylor,
Jian-Ping Chen,
Silviu Covrig Dusa,
Alexander Emmert,
George Evans,
Haiyan Gao,
J. Ole Hansen,
Garth M. Huber,
Sylvester Joosten,
Vladimir Khachatryan,
Nilanga Liyanage,
Zein-Eddine Meziani,
Michael Nycz,
Chao Peng,
Michael Paolone,
Whit Seay,
Paul A. Souder,
Nikos Sparveris,
Hubert Spiesberger,
Ye Tian,
Eric Voutier,
Junqi Xie
, et al. (6 additional authors not shown)
Abstract:
The Solenoidal Large Intensity Device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensit…
▽ More
The Solenoidal Large Intensity Device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensity frontier that will exploit the full potential of its 12 GeV electron beam. In this paper, we present an overview of the rich physics program that can be realized with SoLID, which encompasses the tomography of the nucleon in 3-D momentum space from Semi-Inclusive Deep Inelastic Scattering (SIDIS), expanding the phase space in the search for new physics and novel hadronic effects in parity-violating DIS (PVDIS), a precision measurement of $J/ψ$ production at threshold that probes the gluon field and its contribution to the proton mass, tomography of the nucleon in combined coordinate and momentum space with deep exclusive reactions, and more. To meet the challenging requirements, the design of SoLID described here takes full advantage of recent progress in detector, data acquisition and computing technologies. In addition, we outline potential experiments beyond the currently approved program and discuss the physics that could be explored should upgrades of CEBAF become a reality in the future.
△ Less
Submitted 12 February, 2023; v1 submitted 18 September, 2022;
originally announced September 2022.
-
The P2 Experiment - A future high-precision measurement of the electroweak mixing angle at low momentum transfer
Authors:
Dominik Becker,
Razvan Bucoveanu,
Carsten Grzesik,
Ruth Kempf,
Kathrin Imai,
Matthias Molitor,
Alexey Tyukin,
Marco Zimmermann,
David Armstrong,
Kurt Aulenbacher,
Sebastian Baunack,
Rakitha Beminiwattha,
Niklaus Berger,
Peter Bernhard,
Andrea Brogna,
Luigi Capozza,
Silviu Covrig Dusa,
Wouter Deconinck,
Jürgen Diefenbach,
Jens Erler,
Ciprian Gal,
Boris Gläser,
Boxing Gou,
Wolfgang Gradl,
Michael Gericke
, et al. (20 additional authors not shown)
Abstract:
This article describes the future P2 parity-violating electron scattering facility at the upcoming MESA accelerator in Mainz. The physics program of the facility comprises indirect, high precision search for physics beyond the Standard Model, measurement of the neutron distribution in nuclear physics, single-spin asymmetries stemming from two-photon exchange and a possible future extension to the…
▽ More
This article describes the future P2 parity-violating electron scattering facility at the upcoming MESA accelerator in Mainz. The physics program of the facility comprises indirect, high precision search for physics beyond the Standard Model, measurement of the neutron distribution in nuclear physics, single-spin asymmetries stemming from two-photon exchange and a possible future extension to the measurement of hadronic parity violation. The first measurement of the P2 experiment aims for a high precision determination of the weak mixing angle to a precision of 0.14% at a four-momentum transfer of Q^2 = 4.5 10^{-3} GeV^2. The accuracy is comparable to existing measurements at the Z pole. It comprises a sensitive test of the standard model up to a mass scale of 50 TeV, extendable to 70 TeV. This requires a measurement of the parity violating cross section asymmetry -39.94 10^{-9} in the elastic electron-proton scattering with a total accuracy of 0.56 10^-9 (1.4 %) in 10,000 h of 150 \micro A polarized electron beam impinging on a 60 cm liquid H_2 target allowing for an extraction of the weak charge of the proton which is directly connected to the weak mixing angle. Contributions from gamma Z-box graphs become small at the small beam energy of 155 MeV. The size of the asymmetry is the smallest asymmetry ever measured in electron scattering with an unprecedented goal for the accuracy. We report here on the conceptual design of the P2 spectrometer, its Cherenkov detectors, the integrating read-out electronics as well as the ultra-thin, fast tracking detectors. There has been substantial theory work done in preparation of the determination of the weak mixing angle. The further physics program in particle and nuclear physics is described as well.
△ Less
Submitted 14 March, 2018; v1 submitted 13 February, 2018;
originally announced February 2018.
-
The Q_weak Experimental Apparatus
Authors:
Qweak Collaboration,
T. Allison,
M. Anderson,
D. Androic,
D. S. Armstrong,
A. Asaturyan,
T. D. Averett,
R. Averill,
J. Balewski,
J. Beaufait,
R. S. Beminiwattha,
J. Benesch,
F. Benmokhtar,
J. Bessuille,
J. Birchall,
E. Bonnell,
J. Bowman,
P. Brindza,
D. B. Brown,
R. D. Carlini,
G. D. Cates,
B. Cavness,
G. Clark,
J. C. Cornejo,
S. Covrig Dusa
, et al. (104 additional authors not shown)
Abstract:
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry…
▽ More
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 microA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Moller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8 degrees and 11.6 degrees were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cerenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q^2 = 0.025 GeV^2 was determined using dedicated low-current (~100 pA) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet.
△ Less
Submitted 6 January, 2015; v1 submitted 24 September, 2014;
originally announced September 2014.