TrackRAD2025 challenge dataset: Real-time tumor tracking for MRI-guided radiotherapy
Authors:
Yiling Wang,
Elia Lombardo,
Adrian Thummerer,
Tom Blöcker,
Yu Fan,
Yue Zhao,
Christianna Iris Papadopoulou,
Coen Hurkmans,
Rob H. N. Tijssen,
Pia A. W. Görts,
Shyama U. Tetar,
Davide Cusumano,
Martijn P. W. Intven,
Pim Borman,
Marco Riboldi,
Denis Dudáš,
Hilary Byrne,
Lorenzo Placidi,
Marco Fusella,
Michael Jameson,
Miguel Palacios,
Paul Cobussen,
Tobias Finazzi,
Cornelis J. A. Haasbeek,
Paul Keall
, et al. (3 additional authors not shown)
Abstract:
Purpose: Magnetic resonance imaging (MRI) to visualize anatomical motion is becoming increasingly important when treating cancer patients with radiotherapy. Hybrid MRI-linear accelerator (MRI-linac) systems allow real-time motion management during irradiation. This paper presents a multi-institutional real-time MRI time series dataset from different MRI-linac vendors. The dataset is designed to su…
▽ More
Purpose: Magnetic resonance imaging (MRI) to visualize anatomical motion is becoming increasingly important when treating cancer patients with radiotherapy. Hybrid MRI-linear accelerator (MRI-linac) systems allow real-time motion management during irradiation. This paper presents a multi-institutional real-time MRI time series dataset from different MRI-linac vendors. The dataset is designed to support developing and evaluating real-time tumor localization (tracking) algorithms for MRI-guided radiotherapy within the TrackRAD2025 challenge (https://trackrad2025.grand-challenge.org/).
Acquisition and validation methods: The dataset consists of sagittal 2D cine MRIs in 585 patients from six centers (3 Dutch, 1 German, 1 Australian, and 1 Chinese). Tumors in the thorax, abdomen, and pelvis acquired on two commercially available MRI-linacs (0.35 T and 1.5 T) were included. For 108 cases, irradiation targets or tracking surrogates were manually segmented on each temporal frame. The dataset was randomly split into a public training set of 527 cases (477 unlabeled and 50 labeled) and a private testing set of 58 cases (all labeled).
Data Format and Usage Notes: The data is publicly available under the TrackRAD2025 collection: https://doi.org/10.57967/hf/4539. Both the images and segmentations for each patient are available in metadata format.
Potential Applications: This novel clinical dataset will enable the development and evaluation of real-time tumor localization algorithms for MRI-guided radiotherapy. By enabling more accurate motion management and adaptive treatment strategies, this dataset has the potential to advance the field of radiotherapy significantly.
△ Less
Submitted 23 May, 2025; v1 submitted 24 March, 2025;
originally announced March 2025.
Study of Bulk Damage of High Dose Gamma Irradiated p-type Silicon Diodes with Various Resistivities
Authors:
I. Zatocilova,
M. Mikestikova,
V. Latonova,
J. Kroll,
R. Privara,
P. Novotny,
D. Dudas,
J. Kvasnicka
Abstract:
The bulk damage of p-type silicon detectors caused by high doses of gamma irradiation has been studied. The study was carried out on three types of n$^{+}$-in-p silicon diodes with comparable geometries but different initial resistivities. This allowed to determine how different initial parameters of studied samples influence radiation-induced changes in the measured characteristics. The diodes we…
▽ More
The bulk damage of p-type silicon detectors caused by high doses of gamma irradiation has been studied. The study was carried out on three types of n$^{+}$-in-p silicon diodes with comparable geometries but different initial resistivities. This allowed to determine how different initial parameters of studied samples influence radiation-induced changes in the measured characteristics. The diodes were irradiated by a Cobalt-60 gamma source to total ionizing doses ranging from 0.50 up to 8.28 MGy, and annealed for 80 minutes at 60 °C. The Geant4 toolkit for simulation of the passage of particles through matter was used to simulate the deposited energy homogeneity, to verify the equal distribution of total deposited energies through all the layers of irradiated samples, and to calculate the secondary electron spectra in the irradiation box. The main goal of the study was to characterize the gamma-radiation induced displacement damage by measuring current-voltage characteristics (IV), and the evolution of the full depletion voltage with the total ionizing dose, by measuring capacitance-voltage characteristics (CV). It has been observed that the bulk leakage current increases linearly with total ionizing dose, and the damage coefficient depends on the initial resistivity of the silicon diode. The effective doping concentration and therefore full depletion voltage significantly decreases with increasing total ionizing dose, before starting to increase again at a specific dose. We assume that this decrease is caused by the effect of acceptor removal. Another noteworthy observation of this study is that the IV and CV measurements of the gamma irradiated diodes do not reveal any annealing effect.
△ Less
Submitted 28 September, 2023;
originally announced September 2023.