SuperB Technical Design Report
Authors:
SuperB Collaboration,
M. Baszczyk,
P. Dorosz,
J. Kolodziej,
W. Kucewicz,
M. Sapor,
A. Jeremie,
E. Grauges Pous,
G. E. Bruno,
G. De Robertis,
D. Diacono,
G. Donvito,
P. Fusco,
F. Gargano,
F. Giordano,
F. Loddo,
F. Loparco,
G. P. Maggi,
V. Manzari,
M. N. Mazziotta,
E. Nappi,
A. Palano,
B. Santeramo,
I. Sgura,
L. Silvestris
, et al. (384 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch…
▽ More
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/charm production threshold with a luminosity of 10^{35} cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100 larger than present B Factories, would allow investigation of new physics effects in rare decays, CP Violation and Lepton Flavour Violation. This document details the detector design presented in the Conceptual Design Report (CDR) in 2007. The R&D and engineering studies performed to arrive at the full detector design are described, and an updated cost estimate is presented.
A combination of a more realistic cost estimates and the unavailability of funds due of the global economic climate led to a formal cancelation of the project on Nov 27, 2012.
△ Less
Submitted 24 June, 2013;
originally announced June 2013.
Multi-GeV Electron Spectrometer
Authors:
R. Faccini,
F. Anelli,
A. Bacci,
D. Batani,
M. Bellaveglia,
R. Benocci,
C. Benedetti,
L. Cacciotti,
C. A. Cecchetti,
A. Clozza,
L. Cultrera,
G. Di~Pirro,
N. Drenska,
F. Anelli,
M. Ferrario,
D. Filippetto,
S. Fioravanti,
A. Gallo,
A. Gamucci,
G. Gatti,
A. Ghigo,
A. Giulietti,
D. Giulietti,
L. A. Gizzi,
P. Koester
, et al. (13 additional authors not shown)
Abstract:
The advance in laser plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1pC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected.…
▽ More
The advance in laser plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1pC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction of such a device. We will present the design considerations for this spectrometer and the first results from a prototype.
△ Less
Submitted 18 February, 2010;
originally announced February 2010.