The MUSE Beamline Calorimeter
Authors:
W. Lin,
T. Rostomyan,
R. Gilman,
S. Strauch,
C. Meier,
C. Nestler,
M. Ali,
H. Atac,
J. C. Bernauer,
W. J. Briscoe,
A. Christopher Ndukwe,
E. W. Cline,
K. Deiters,
S. Dogra,
E. J. Downie,
Z. Duan,
I. P. Fernando,
A. Flannery,
D. Ghosal,
A. Golossanov,
J. Guo,
N. S. Ifat,
Y. Ilieva,
M. Kohl,
I. Lavrukhin
, et al. (18 additional authors not shown)
Abstract:
The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron-proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measuremen…
▽ More
The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron-proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron-proton and muon-proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. In this article we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.
△ Less
Submitted 23 August, 2024;
originally announced August 2024.
-
Blinding for precision scattering experiments: The MUSE approach as a case study
Authors:
J. C. Bernauer,
E. W. Cline,
H. Atac,
W. J. Briscoe,
A. Christopher Ndukwe,
E. J. Downie,
I. P. Fernando,
T. Gautam,
R. Gilman,
R. Goldin,
M. Kohl,
I. Lavrukhin,
W. Lin,
W. Lorenzon,
P. Mohanmurthy,
S. J. Nazeer,
M. Nicol,
T. Patel,
A. Prosnyakov,
R. D. Ransome,
R. Ratvasky,
H. Reid,
P. E. Reimer,
G. Ron,
T. Rostomyan
, et al. (5 additional authors not shown)
Abstract:
Human bias is capable of changing the analysis of measured data sufficiently to alter the results of an experiment. It is incumbent upon modern experiments, especially those investigating quantities considered contentious in the broader community, to blind their analysis in an effort to minimize bias. The choice of a blinding model is experiment specific, but should also aim to prevent accidental…
▽ More
Human bias is capable of changing the analysis of measured data sufficiently to alter the results of an experiment. It is incumbent upon modern experiments, especially those investigating quantities considered contentious in the broader community, to blind their analysis in an effort to minimize bias. The choice of a blinding model is experiment specific, but should also aim to prevent accidental release of results before an analysis is finalized. In this paper, we discuss common threats to an unbiased analysis, as well as common quantities that can be blinded in different types of nuclear physics experiments. We use the Muon Scattering Experiment as an example, and detail the blinding scheme used therein.
△ Less
Submitted 16 October, 2023;
originally announced October 2023.
-
Characterization of Muon and Electron Beams in the Paul Scherrer Institute PiM1 Channel for the MUSE Experiment
Authors:
E. Cline,
W. Lin,
P. Roy,
P. E. Reimer,
K. E. Mesick,
A. Akmal,
A. Alie,
H. Atac,
A. Atencio,
C. Ayerbe Gayoso,
N. Benmouna,
F. Benmokhtar,
J. C. Bernauer,
W. J. Briscoe,
J. Campbell,
D. Cohen,
E. O. Cohen,
C. Collicott,
K. Deiters,
S. Dogra,
E. Downie,
I. P. Fernando,
A. Flannery,
T. Gautam,
D. Ghosal
, et al. (35 additional authors not shown)
Abstract:
The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the prope…
▽ More
The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the properties of the beam line established for pions. We discuss the production processes that generate the electron and muon beams, and the simulations of these processes. Simulations of the $π$/$μ$/$e$ beams through the channel using TURTLE and G4beamline are compared. The G4beamline simulation is then compared to several experimental measurements of the channel, including the momentum dispersion at the IFP and target, the shape of the beam spot at the target, and timing measurements that allow the beam momenta to be determined. We conclude that the PiM1 channel can be used for high precision $π$, $μ$, and $e$ scattering.
△ Less
Submitted 15 September, 2021;
originally announced September 2021.
-
International Workshop on Next Generation Gamma-Ray Source
Authors:
C. R. Howell,
M. W. Ahmed,
A. Afanasev,
D. Alesini,
J. R. M. Annand,
A. Aprahamian,
D. L. Balabanski,
S. V. Benson,
A. Bernstein,
C. R. Brune,
J. Byrd,
B. E. Carlsten,
A. E. Champagne,
S. Chattopadhyay,
D. Davis,
E. J. Downie,
M. J. Durham,
G. Feldman,
H. Gao,
C. G. R. Geddes,
H. W. Griesshammer,
R. Hajima,
H. Hao,
D. Hornidge,
J. Isaak
, et al. (28 additional authors not shown)
Abstract:
A workshop on The Next Generation Gamma-Ray Sources sponsored by the Office of Nuclear Physics at the Department of Energy, was held November 17--19, 2016 in Bethesda, Maryland. The goals of the workshop were to identify basic and applied research opportunities at the frontiers of nuclear physics that would be made possible by the beam capabilities of an advanced laser Compton beam facility. To an…
▽ More
A workshop on The Next Generation Gamma-Ray Sources sponsored by the Office of Nuclear Physics at the Department of Energy, was held November 17--19, 2016 in Bethesda, Maryland. The goals of the workshop were to identify basic and applied research opportunities at the frontiers of nuclear physics that would be made possible by the beam capabilities of an advanced laser Compton beam facility. To anchor the scientific vision to realistically achievable beam specifications using proven technologies, the workshop brought together experts in the fields of electron accelerators, lasers, and optics to examine the technical options for achieving the beam specifications required by the most compelling parts of the proposed research programs. An international assembly of participants included current and prospective $γ$-ray beam users, accelerator and light-source physicists, and federal agency program managers. Sessions were organized to foster interactions between the beam users and facility developers, allowing for information sharing and mutual feedback between the two groups. The workshop findings and recommendations are summarized in this whitepaper.
△ Less
Submitted 19 December, 2020;
originally announced December 2020.
-
Timing Detectors with SiPM read-out for the MUSE Experiment at PSI
Authors:
Tigran Rostomyan,
Ethan Cline,
Ievgen Lavrukhin,
Hamza Atac,
Ariella Atencio,
Jan C. Bernauer,
William J. Briscoe,
Dan Cohen,
Erez O. Cohen,
Cristina Collicott,
Konrad Deiters,
Shraddha Dogra,
Evangeline Downie,
Werner Erni,
Ishara P. Fernando,
Anne Flannery,
Thir Gautam,
Debdeep Ghosal,
Ronald Gilman,
Alexander Golossanov,
Jack Hirschman,
Minjung Kim,
Michael Kohl,
Bernd Krusche,
Lin Li
, et al. (18 additional authors not shown)
Abstract:
The Muon Scattering Experiment at the Paul Scherrer Institut uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of three timing detectors using plastic scintillator read out with silicon photomultipliers that have been built for the experiment. The Beam Hodoscope, upstream of…
▽ More
The Muon Scattering Experiment at the Paul Scherrer Institut uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of three timing detectors using plastic scintillator read out with silicon photomultipliers that have been built for the experiment. The Beam Hodoscope, upstream of the scattering target, counts the beam flux and precisely times beam particles both to identify species and provide a starting time for time-of-flight measurements. The Beam Monitor, downstream of the scattering target, counts the unscattered beam flux, helps identify background in scattering events, and precisely times beam particles for time-of-flight measurements. The Beam Focus Monitor, mounted on the target ladder under the liquid hydrogen target inside the target vacuum chamber, is used in dedicated runs to sample the beam spot at three points near the target center, where the beam should be focused.
△ Less
Submitted 15 October, 2020; v1 submitted 23 July, 2020;
originally announced July 2020.
-
Technical Design Report for the Paul Scherrer Institute Experiment R-12-01.1: Studying the Proton "Radius" Puzzle with μp Elastic Scattering
Authors:
R. Gilman,
E. J. Downie,
G. Ron,
S. Strauch,
A. Afanasev,
A. Akmal,
J. Arrington,
H. Atac,
C. Ayerbe-Gayoso,
F. Benmokhtar,
N. Benmouna,
J. Bernauer,
A. Blomberg,
W. J. Briscoe,
D. Cioffi,
E. Cline,
D. Cohen,
E. O. Cohen,
C. Collicott,
K. Deiters,
J. Diefenbach,
B. Dongwi,
D. Ghosal,
A. Golossanov,
R. Gothe
, et al. (34 additional authors not shown)
Abstract:
The difference in proton radii measured with $μp$ atoms and with $ep$ atoms and scattering remains an unexplained puzzle. The PSI MUSE proposal is to measure $μp$ and $e p$ scattering in the same experiment at the same time. The experiment will determine cross sections, two-photon effects, form factors, and radii independently for the two reactions, and will allow $μp$ and $ep$ results to be compa…
▽ More
The difference in proton radii measured with $μp$ atoms and with $ep$ atoms and scattering remains an unexplained puzzle. The PSI MUSE proposal is to measure $μp$ and $e p$ scattering in the same experiment at the same time. The experiment will determine cross sections, two-photon effects, form factors, and radii independently for the two reactions, and will allow $μp$ and $ep$ results to be compared with reduced systematic uncertainties. These data should provide the best test of lepton universality in a scattering experiment to date, about an order of magnitude improvement over previous tests. Measuring scattering with both particle polarities will allow a test of two-photon exchange at the sub-percent level, about a factor of four improvement on uncertainties and over an order of magnitude more data points than previous low momentum transfer determinations, and similar to the current generation of higher momentum transfer electron experiments. The experiment has the potential to demonstrate whether the $μp$ and $ep$ interactions are consistent or different, and whether any difference results from novel physics or two-photon exchange. The uncertainties are such that if the discrepancy is real it should be confirmed with $\approx$5$σ$ significance, similar to that already established between the regular and muonic hydrogen Lamb shift.
△ Less
Submitted 27 September, 2017;
originally announced September 2017.
-
A new measurement of the neutron detection efficiency for the NaI Crystal Ball detector
Authors:
M. Martemianov,
V. Kulikov,
B. T. Demissie,
Z. Marinides,
C. S. Akondi,
J. R. M. Annand,
H. J. Arends,
R. Beck,
N. Borisov,
A. Braghieri,
W. J. Briscoe,
S. Cherepnya,
C. Collicott,
S. Costanza,
E. J. Downie,
M. Dieterle,
M. I. Ferretti Bondy,
L. V. Filkov,
S. Garni,
D. I. Glazier,
D. Glowa,
W. Gradl,
G. Gurevich,
D. Hornidge,
G. M. Huber
, et al. (46 additional authors not shown)
Abstract:
We report on a measurement of the neutron detection efficiency in NaI crystals in the Crystal Ball detector obtained from a study of single p0 photoproduction on deuterium using the tagged photon beam at the Mainz Microtron. The results were obtained up to a neutron energy of 400 MeV. They are compared to previous measurements made more than 15 years ago at the pion beam at the BNL AGS.
We report on a measurement of the neutron detection efficiency in NaI crystals in the Crystal Ball detector obtained from a study of single p0 photoproduction on deuterium using the tagged photon beam at the Mainz Microtron. The results were obtained up to a neutron energy of 400 MeV. They are compared to previous measurements made more than 15 years ago at the pion beam at the BNL AGS.
△ Less
Submitted 25 February, 2015;
originally announced February 2015.
-
Charge asymmetry in high-energy $μ^+μ^-$ photoproduction in the electric field of a heavy atom
Authors:
E. J. Downie,
R. N. Lee,
A. I. Milstein,
G. Ron
Abstract:
The charge asymmetry in the differential cross section of high-energy $μ^+μ^-$ photoproduction in the electric field of a heavy atom is obtained. This asymmetry arises due to the Coulomb corrections to the amplitude of the process (next-to-leading term with respect to the atomic field). The deviation of the nuclear electric field from the Coulomb field at small distances is crucially important for…
▽ More
The charge asymmetry in the differential cross section of high-energy $μ^+μ^-$ photoproduction in the electric field of a heavy atom is obtained. This asymmetry arises due to the Coulomb corrections to the amplitude of the process (next-to-leading term with respect to the atomic field). The deviation of the nuclear electric field from the Coulomb field at small distances is crucially important for the charge asymmetry. Though the Coulomb corrections to the total cross section are negligibly small, the charge asymmetry is measurable for selected final states of $μ^+$ and $μ^-$. We further discuss the feasibility for experimental observation of this effect.
△ Less
Submitted 4 December, 2013;
originally announced December 2013.
-
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
Authors:
The PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and…
▽ More
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.