Single event effect characterization of the mixed-signal ASIC developed for CCD camera in space use
Authors:
Hiroshi Nakajima,
Mari Fujikawa,
Hideki Mori,
Hiroaki Kan,
Shutaro Ueda,
Hiroko Kosugi,
Naohisa Anabuki,
Kiyoshi Hayashida,
Hiroshi Tsunemi,
John P. Doty,
Hirokazu Ikeda,
Hisashi Kitamura,
Yukio Uchihori
Abstract:
We present the single event effect (SEE) tolerance of a mixed-signal application-specific integrated circuit (ASIC) developed for a charge-coupled device camera onboard a future X-ray astronomical mission. We adopted proton and heavy ion beams at HIMAC/NIRS in Japan. The particles with high linear energy transfer (LET) of 57.9 MeV cm^{2}/mg is used to measure the single event latch-up (SEL) tolera…
▽ More
We present the single event effect (SEE) tolerance of a mixed-signal application-specific integrated circuit (ASIC) developed for a charge-coupled device camera onboard a future X-ray astronomical mission. We adopted proton and heavy ion beams at HIMAC/NIRS in Japan. The particles with high linear energy transfer (LET) of 57.9 MeV cm^{2}/mg is used to measure the single event latch-up (SEL) tolerance, which results in a sufficiently low cross-section of sigma_{SEL} < 4.2x10^{-11} cm^{2}/(IonxASIC). The single event upset (SEU) tolerance is estimated with various kinds of species with wide range of energy. Taking into account that a part of the protons creates recoiled heavy ions that has higher LET than that of the incident protons, we derived the probability of SEU event as a function of LET. Then the SEE event rate in a low-earth orbit is estimated considering a simulation result of LET spectrum. SEL rate is below once per 49 years, which satisfies the required latch-up tolerance. The upper limit of the SEU rate is derived to be 1.3x10^{-3}events/sec. Although the SEU events cannot be distinguished from the signals of X-ray photons from astronomical objects, the derived SEU rate is below 1.3% of expected non-X-ray background rate of the detector and hence these events should not be a major component of the instrumental background.
△ Less
Submitted 11 July, 2013;
originally announced July 2013.
Development of the analog ASIC for multi-channel readout X-ray CCD camera
Authors:
Hiroshi Nakajima,
Daisuke Matsuura,
Toshihiro Idehara,
Naohisa Anabuki,
Hiroshi Tsunemi,
John P. Doty,
Hirokazu Ikeda,
Haruyoshi Katayama,
Hisashi Kitamura,
Yukio Uchihori
Abstract:
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that…
▽ More
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that outputs only digital signals. As the result of the front-end electronics test, it works properly with low input noise of =<30 uV at the pixel rate below 100 kHz. The power consumption is sufficiently low of about 150 mW/chip. The input signal range of 720 mV covers the effective energy range of the typical X-ray photon counting CCD (up to 20 keV). The integrated non-linearity is 0.2% that is similar as those of the conventional CCDs in orbit. We also performed a radiation tolerance test against the total ionizing dose (TID) effect and the single event effect. The irradiation test using 60Co and proton beam showed that the ASIC has the sufficient tolerance against TID up to 200 krad, which absolutely exceeds the expected amount of dose during the period of operating in a low-inclination low-earth orbit. The irradiation of Fe ions with the fluence of 5.2x10^8 Ion/cm2 resulted in no single event latchup (SEL), although there were some possible single event upsets. The threshold against SEL is higher than 1.68 MeV cm^2/mg, which is sufficiently high enough that the SEL event should not be one of major causes of instrument downtime in orbit.
△ Less
Submitted 11 February, 2011;
originally announced February 2011.