-
First Beam Neutrinos Observed with an LAPPD in the ANNIE Experiment
Authors:
B. W. Adams,
S. Abubakar,
D. Ajana,
M. A. Aman,
M. Ascencio-Sosa,
A. Augusthy,
Z. Bagdasarian,
J. Beacom,
M. Bergevin,
D. Bick,
M. Breisch,
E. Brunner-Huber,
G. Caceres Vera,
S. Dazeley,
S. Deng,
S. Donnelly,
S. Doran,
E. Drakopoulou,
S. Edayath,
R. Edwards,
J. Eisch,
Y. Feng,
V. Fischer,
R. Foster,
S. Gardiner
, et al. (48 additional authors not shown)
Abstract:
The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) probes the physics of neutrino-nucleus interactions in a gadolinium-loaded water (Gd-water) target while serving as a flexible testbed for advanced next-generation optical neutrino detection technologies. These advanced technologies include novel detection media (particularly Gd-water and hybrid Cherenkov-scintillation through water-b…
▽ More
The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) probes the physics of neutrino-nucleus interactions in a gadolinium-loaded water (Gd-water) target while serving as a flexible testbed for advanced next-generation optical neutrino detection technologies. These advanced technologies include novel detection media (particularly Gd-water and hybrid Cherenkov-scintillation through water-based liquid scintillator) and novel photosensors. In this paper we demonstrate the first implementation of a fully-integrated setup for Large Area Picosecond PhotoDetectors (LAPPDs) in a neutrino experiment. Details are presented regarding the design, commissioning, and deployment of an LAPPD and the supporting systems. We also present the first neutrino interactions ever observed with an LAPPD.
△ Less
Submitted 14 August, 2025;
originally announced August 2025.
-
ExoMol line lists -- XLIV. IR and UV line list for silicon monoxide (SiO)
Authors:
Sergei N. Yurchenko,
Jonathan Tennyson,
Anna-Maree Syme,
Ahmad Y. Adam,
Victoria H. J. Clark,
Bridgette Cooper,
C. Pria Dobney,
Shaun T. E. Donnelly,
Maire N. Gorman,
Anthony E. Lynas-Gray,
Thomas Meltzer,
Alec Owens,
Qianwei Qu,
Mikhail Semenov,
Wilfrid Somogyi,
Apoorva Upadhyay,
Samuel Wright,
Juan C. Zapata Trujillo
Abstract:
A new silicon monoxide ($^{28}$Si$^{16}$O) line list covering infrared, visible and ultraviolet regions called SiOUVenIR is presented. This line list extends the infrared EBJT ExoMol line list by including vibronic transitions to the $A\,{}^{1}Π$ and $E\,{}^{1}Σ^{+}$ electronic states. Strong perturbations to the $A\,{}^{1}Π$ band system are accurately modelled through the treatment of 6 dark elec…
▽ More
A new silicon monoxide ($^{28}$Si$^{16}$O) line list covering infrared, visible and ultraviolet regions called SiOUVenIR is presented. This line list extends the infrared EBJT ExoMol line list by including vibronic transitions to the $A\,{}^{1}Π$ and $E\,{}^{1}Σ^{+}$ electronic states. Strong perturbations to the $A\,{}^{1}Π$ band system are accurately modelled through the treatment of 6 dark electronic states: $C\,{}^{1}Σ^{-}$, $D\,{}^{1}Δ$, $a\,{}^{3}Σ^{+}$, $b\,{}^{3}Π$, $e\,{}^{3}Σ^{-}$ and $d\,{}^{3}Δ$. Along with the $X\,{}^{1}Σ^{+}$ ground state, these 9 electronic states were used to build a comprehensive spectroscopic model of SiO using a combination of empirical and ab initio curves, including the potential energy (PE), spin-orbit (SO), electronic angular momentum (EAM) and (transition) dipole moment curves. The ab initio PE and coupling curves, computed at the multireference configuration interaction (MRCI) level of theory, were refined by fitting their analytical representations to 2617 experimentally derived SiO energy levels determined from 97 vibronic bands belonging to the $X$-$X$, $E$-$X$ and $A$-$X$ electronic systems through the MARVEL procedure. 112 observed forbidden transitions from the $C$-$X$, $D$-$X$, $e$-$X$, and $d$-$X$ bands were assigned using our predictions, and these could be fed back into the MARVEL procedure. The SiOUVenIR line list was computed using published ab initio transition dipole moments for the $E$-$X$ and $A$-$X$ bands; the line list is suitable for temperatures up to 10,000 K and for wavelengths longer than 140 nm. SiOUVenIR is available from www.exomol.com and the CDS database.
△ Less
Submitted 8 November, 2021;
originally announced November 2021.
-
Steepest-descent algorithm for simulating plasma-wave caustics via metaplectic geometrical optics
Authors:
Sean M. Donnelly,
Nicolas A. Lopez,
I. Y. Dodin
Abstract:
The design and optimization of radiofrequency-wave systems for fusion applications is often performed using ray-tracing codes, which rely on the geometrical-optics (GO) approximation. However, GO fails at wave cutoffs and caustics. To accurately model the wave behavior in these regions, more advanced and computationally expensive "full-wave" simulations are typically used, but this is not strictly…
▽ More
The design and optimization of radiofrequency-wave systems for fusion applications is often performed using ray-tracing codes, which rely on the geometrical-optics (GO) approximation. However, GO fails at wave cutoffs and caustics. To accurately model the wave behavior in these regions, more advanced and computationally expensive "full-wave" simulations are typically used, but this is not strictly necessary. A new generalized formulation called metaplectic geometrical optics (MGO) has been proposed that reinstates GO near caustics. The MGO framework yields an integral representation of the wavefield that must be evaluated numerically in general. We present an algorithm for computing these integrals using Gauss-Freud quadrature along the steepest-descent contours. Benchmarking is performed on the standard Airy problem, for which the exact solution is known analytically. The numerical MGO solution provided by the new algorithm agrees remarkably well with the exact solution and significantly improves upon previously derived analytical approximations of the MGO integral.
△ Less
Submitted 13 August, 2021; v1 submitted 27 April, 2021;
originally announced April 2021.
-
Modification of Nanodiamonds by Xenon Implantation: A Molecular Dynamics Study
Authors:
Jason L. Fogg,
Alireza Aghajamali,
Jonathan A. Hinks,
Stephen E. Donnelly,
Andrey A. Shiryaev,
Nigel A. Marks
Abstract:
Xenon implantation into nanodiamonds is studied using molecular dynamics. The nanodiamonds range in size from 2-10 nm and the primary knock-on (PKA) energy extends up to 40 keV. For small nanodiamonds an energy-window effect occurs in which PKA energies of around 6 keV destroy the nanodiamond, while in larger nanodiamonds the radiation cascade is increasingly similar to those in bulk material. Des…
▽ More
Xenon implantation into nanodiamonds is studied using molecular dynamics. The nanodiamonds range in size from 2-10 nm and the primary knock-on (PKA) energy extends up to 40 keV. For small nanodiamonds an energy-window effect occurs in which PKA energies of around 6 keV destroy the nanodiamond, while in larger nanodiamonds the radiation cascade is increasingly similar to those in bulk material. Destruction of the small nanodiamonds occurs due to thermal annealing associated with the small size of the particles and the absence of a heat-loss path. Simulations are also performed for a range of impact parameters, and for a series of double-nanodiamond systems in which a heat-loss path is present. The latter show that the thermal shock caused by the impact occurs on the timescale of a few picoseconds. These findings are relevant to ion-beam modification of nanoparticles by noble gases as well as meteoritic studies where implantation is proposed as the mechanism for xenon incorporation in pre-solar nanodiamonds.
△ Less
Submitted 26 March, 2019;
originally announced March 2019.
-
Quantum magnetic resonance microscopy
Authors:
David A. Simpson,
Robert G. Ryan,
Liam T. Hall,
Evgeniy Panchenko,
Simon C. Drew,
Steven Petrou,
Paul S. Donnelly,
Paul Mulvaney,
Lloyd C. L. Hollenberg
Abstract:
Magnetic resonance spectroscopy is universally regarded as one of the most important tools in chemical and bio-medical research. However, sensitivity limitations typically restrict imaging resolution to length scales greater than 10 μm. Here we bring quantum control to the detection of chemical systems to demonstrate high resolution electron spin imaging using the quantum properties of an array of…
▽ More
Magnetic resonance spectroscopy is universally regarded as one of the most important tools in chemical and bio-medical research. However, sensitivity limitations typically restrict imaging resolution to length scales greater than 10 μm. Here we bring quantum control to the detection of chemical systems to demonstrate high resolution electron spin imaging using the quantum properties of an array of nitrogen-vacancy (NV) centres in diamond. Our quantum magnetic resonance microscope selectively images electronic spin species by precisely tuning a magnetic field to bring the quantum probes into resonance with the external target spins. This provides diffraction limited spatial resolution of the target spin species over a field of view of ~50x50 μm^2. We demonstrate imaging and spectroscopy on aqueous Cu2+ ions over microscopic volumes (0.025 μm^3), with detection sensitivity at resonance of 104 spins/voxel, ~100 zeptomol (10^-19 mol). The ability to image, perform spectroscopy and dynamically monitor spin-dependent redox reactions and transition metal biochemistry at these scales opens up a new realm of nanoscopic electron spin resonance and zepto-chemistry in the physical and life sciences.
△ Less
Submitted 14 February, 2017;
originally announced February 2017.