Diamond Detectors for the TOTEM Timing Upgrade
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
P. Broulím,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
F. De Leonardis,
A. D'Orazio,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski
, et al. (58 additional authors not shown)
Abstract:
This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with o…
▽ More
This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with one of the vertices reconstructed by the CMS detectors. The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD) diamond plates and is designed to measure the protons TOF with about 50 ps time precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2 and will tag the central diffractive events up to an interaction pileup of about 1. A dedicated fast and low noise electronics for the signal amplification has been developed. The digitization of the diamond signal is performed by sampling the waveform. After introducing the physics studies that will most profit from the addition of these new detectors, we discuss in detail the optimization and the performance of the first TOF detector installed in the LHC in November 2015.
△ Less
Submitted 18 January, 2017;
originally announced January 2017.
-
Construction and Test of the Precision Drift Chambers for the ATLAS Muon Spectrometer
Authors:
F. Bauer,
W. Blum,
U. Bratzler,
H. Dietl,
S. Kotov,
H. Kroha,
Th. Lagouri,
A. Manz,
A. Ostapchuk,
R. Richter,
S. Schael,
S. Chouridou,
M. Deile,
O. Kortner,
A. Staude,
R. Stroehmer,
T. Trefzger
Abstract:
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurised drift tubes on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 microns with a single-tube resolution of at least 80 microns and a sense wire posi…
▽ More
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurised drift tubes on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 microns with a single-tube resolution of at least 80 microns and a sense wire positioning accu- racy of 20 ?microns (rms). The feasibility was demonstrated with the full-scale prototype of one of the largest MDT chambers with 432 drift tubes of 3.8 m length. For the ATLAS muon spectrometer, 88 chambers of this type have to be built. The first chamber has been completed with a wire positioning accuracy of 14 microns (rms).
△ Less
Submitted 8 April, 2016;
originally announced April 2016.
-
Construction and Test of MDT Chambers for the ATLAS Muon Spectrometer
Authors:
F. Bauer,
U. Bratzler,
H. Dietl,
H. Kroha,
Th. Lagouri,
A. Manz,
A. Ostapchuk,
R. Richter,
S. Schael,
S. Chouridou,
M. Deile,
O. Kortner,
A. Staude,
R. Stroehmer,
T. Trefzger
Abstract:
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the AT- LAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical monitoring system to correct for deformations. The full-scale prototype of a large MDT chamber has been constructed with methods suitable for large-scale production. X-ray me…
▽ More
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the AT- LAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical monitoring system to correct for deformations. The full-scale prototype of a large MDT chamber has been constructed with methods suitable for large-scale production. X-ray measurements at CERN showed a positioning accuracy of the sense wires in the chamber of better than the required 20 ?microns (rms). The performance of the chamber was studied in a muon beam at CERN. Chamber production for ATLAS now has started.
△ Less
Submitted 7 April, 2016;
originally announced April 2016.
-
Performance of the ATLAS Precision Muon Chambers under LHC Operating Conditions
Authors:
M. Deile,
H. Dietl,
J. Dubbert,
S. Horvat,
O. Kortner,
H. Kroha,
A. Manz,
S. Mohrdieck,
F. Rauscher,
R. Richter,
A. Staude
Abstract:
For the muon spectrometer of the ATLAS detector at the large hadron collider (LHC), large drift chambers consisting of 6 to 8 layers of pressurized drift tubes are used for precision tracking covering an active area of 5000 m2 in the toroidal field of superconducting air core magnets. The chambers have to provide a spatial resolution of 41 microns with Ar:CO2 (93:7) gas mixture at an absolute pres…
▽ More
For the muon spectrometer of the ATLAS detector at the large hadron collider (LHC), large drift chambers consisting of 6 to 8 layers of pressurized drift tubes are used for precision tracking covering an active area of 5000 m2 in the toroidal field of superconducting air core magnets. The chambers have to provide a spatial resolution of 41 microns with Ar:CO2 (93:7) gas mixture at an absolute pressure of 3 bar and gas gain of 2?104. The environment in which the chambers will be operated is characterized by high neutron and background with counting rates of up to 100 per square cm and second. The resolution and efficiency of a chamber from the serial production for ATLAS has been investigated in a 100 GeV muon beam at photon irradiation rates as expected during LHC operation. A silicon strip detector telescope was used as external reference in the beam. The spatial resolution of a chamber is degraded by 4 ?m at the highest background rate. The detection efficiency of the drift tubes is unchanged under irradiation. A tracking efficiency of 98% at the highest rates has been demonstrated.
△ Less
Submitted 1 April, 2016;
originally announced April 2016.
-
Resolution and Efficiency of the ATLAS Muon Drift-Tube Chambers at High Background Rates
Authors:
M. Deile,
J. Dubbert,
S. Horvat,
O. Kortner,
H. Kroha,
A. Manz,
S. Mohrdieck-Moeck,
F. Rauscher,
R. Richter,
A. Staude,
W. Stiller
Abstract:
The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of up to 990 Hz/square cm which corresponds to twice the highest background rate expected in ATLAS. A silicon strip detector telescope was used as external referenc…
▽ More
The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of up to 990 Hz/square cm which corresponds to twice the highest background rate expected in ATLAS. A silicon strip detector telescope was used as external reference in the beam. The pulse-height measurement of the read-out electronics was used to perform time-slewing corrections which lead to an improvement of the average drift-tube resolution from 104 microns to 82 microns without irradiation and from 128 microns to 108 microns at the maximum expected rate. The measured drift-tube efficiency agrees with the expectation from the dead time of the read-out electronics up to the maximum expected rate.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
LHC Optics Measurement with Proton Tracks Detected by the Roman Pots of the TOTEM Experiment
Authors:
The TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski,
F. Garcia
, et al. (54 additional authors not shown)
Abstract:
Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport…
▽ More
Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport is of key importance for the experiment. A novel method of optics evaluation is proposed which exploits kinematical distributions of elastically scattered protons observed in the RPs. Theoretical predictions, as well as Monte Carlo studies, show that the residual uncertainty of this optics estimation method is smaller than 0.25 percent.
△ Less
Submitted 2 June, 2014;
originally announced June 2014.
-
Performance of the TOTEM Detectors at the LHC
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
M. G. Bagliesi,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
R. Cecchi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro
, et al. (57 additional authors not shown)
Abstract:
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity regi…
▽ More
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and +- 220 m from IP5. This article describes in detail the working of the TOTEM detector to produce physics results in the first three years of operation and data taking at the LHC.
△ Less
Submitted 10 October, 2013;
originally announced October 2013.
-
The First 1 1/2 Years of TOTEM Roman Pot Operation at LHC
Authors:
M. Deile,
G. H. Antchev,
R. B. Appleby,
R. W. Assmann,
I. Atanassov,
V. Avati,
J. Baechler,
R. Bruce,
M. Dupont,
K. Eggert,
B. Farnham,
J. Kaspar,
F. Lucas Rodriguez,
J. Morant,
H. Niewiadomski,
X. Pons,
E. Radermacher,
S. Ravat,
F. Ravotti,
S. Redaelli,
G. Ruggiero,
H. Sabba,
M. Sapinski,
W. Snoeys,
G. Valentino
, et al. (1 additional authors not shown)
Abstract:
Since the LHC running season 2010, the TOTEM Roman Pots (RPs) are fully operational and serve for collecting elastic and diffractive proton-proton scattering data. Like for other moveable devices approaching the high intensity LHC beams, a reliable and precise control of the RP position is critical to machine protection. After a review of the RP movement control and position interlock system, the…
▽ More
Since the LHC running season 2010, the TOTEM Roman Pots (RPs) are fully operational and serve for collecting elastic and diffractive proton-proton scattering data. Like for other moveable devices approaching the high intensity LHC beams, a reliable and precise control of the RP position is critical to machine protection. After a review of the RP movement control and position interlock system, the crucial task of alignment will be discussed.
△ Less
Submitted 26 October, 2011;
originally announced October 2011.
-
Beam Coupling Impedance Measurement and Mitigation for a TOTEM Roman Pot
Authors:
Mario Deile,
Fritz Caspers,
Tom Kroyer,
Marco Oriunno,
Ernst Radermacher,
Federico Roncarolo,
Anna Soter
Abstract:
The longitudinal and transverse beam coupling impedance of the first final TOTEM Roman Pot unit has been measured in the laboratory with the wire method. For the evaluation of transverse impedance the wire position has been kept constant, and the insertions of the RP were moved asymmetrically. With the original configuration of the RP, resonances with fairly high Q values were observed. In order…
▽ More
The longitudinal and transverse beam coupling impedance of the first final TOTEM Roman Pot unit has been measured in the laboratory with the wire method. For the evaluation of transverse impedance the wire position has been kept constant, and the insertions of the RP were moved asymmetrically. With the original configuration of the RP, resonances with fairly high Q values were observed. In order to mitigate this problem, RF-absorbing ferrite plates were mounted in appropriate locations. As a result, all resonances were sufficiently damped to meet the stringent LHC beam coupling impedance requirements.
△ Less
Submitted 30 June, 2008;
originally announced June 2008.
-
Tests of a Roman Pot Prototype for the TOTEM Experiment
Authors:
M. Deile
Abstract:
The TOTEM collaboration has developed and tested the first prototype of its Roman Pots to be operated in the LHC. TOTEM Roman Pots contain stacks of 10 silicon detectors with strips oriented in two orthogonal directions. To measure proton scattering angles of a few microradians, the detectors will approach the beam centre to a distance of 10 sigma + 0.5 mm (= 1.3 mm). Dead space near the detecto…
▽ More
The TOTEM collaboration has developed and tested the first prototype of its Roman Pots to be operated in the LHC. TOTEM Roman Pots contain stacks of 10 silicon detectors with strips oriented in two orthogonal directions. To measure proton scattering angles of a few microradians, the detectors will approach the beam centre to a distance of 10 sigma + 0.5 mm (= 1.3 mm). Dead space near the detector edge is minimised by using two novel "edgeless" detector technologies. The silicon detectors are used both for precise track reconstruction and for triggering. The first full-sized prototypes of both detector technologies as well as their read-out electronics have been developed, built and operated. The tests took place first in a fixed-target muon beam at CERN's SPS, and then in the proton beam-line of the SPS accelerator ring. We present the test beam results demonstrating the successful functionality of the system despite slight technical shortcomings to be improved in the near future.
△ Less
Submitted 11 July, 2005;
originally announced July 2005.