In situ ultrasound imaging of shear shock waves in the porcine brain
Authors:
Sandhya Chandrasekaran,
Francisco Santibanez,
Bharat B. Tripathi,
Ryan DeRuiter,
Gianmarco F. Pinton
Abstract:
Using high frame-rate ultrasound and high sensitivity motion tracking, we recently showed that shear waves sent to the ex vivo porcine brain develop into shear shock waves with destructive local accelerations inside the brain which may be a key mechanism behind deep traumatic brain injuries. Direct measurement of brain motion at an adequate frame-rate during impacts has been a persistent challenge…
▽ More
Using high frame-rate ultrasound and high sensitivity motion tracking, we recently showed that shear waves sent to the ex vivo porcine brain develop into shear shock waves with destructive local accelerations inside the brain which may be a key mechanism behind deep traumatic brain injuries. Direct measurement of brain motion at an adequate frame-rate during impacts has been a persistent challenge. Here we present the ultrasound observation of shear shock waves in the acoustically challenging environment of the in situ porcine brain during a single-shot impact. The brain was attached to a plate source which was vibrated at a moderate amplitude of 25g, to propagate a 40 Hz shear wave into the brain. Simultaneously, images of the moving brain were acquired at 2193 images/s, using a custom imaging sequence with 8 interleaved ultrasound transmit-receive events, designed to accurately track shear shocks. To achieve a long field-of-view, wide-beam emissions were designed using time-reversal ultrasound simulations and no compounding was used to avoid motion blurring. A peak acceleration of 102g was measured at the shock-front, 7.1 mm deep inside the brain. It is also shown that experimental shear velocity, acceleration, and strain-rate waveforms in brain are in excellent agreement with theoretical predictions from a custom higher-order finite volume method hence demonstrating the capabilities to measure rapid brain motion even in the presence of strong acoustical reverberations from the porcine skull.
△ Less
Submitted 24 April, 2021;
originally announced April 2021.
Quantitative sub-resolution blood velocity estimation using ultrasound localization microscopy ex-vivo and in-vivo
Authors:
David Espindola,
Ryan M. DeRuiter,
Francisco Santibanez,
Paul A. Dayton,
Gianmarco Pinton
Abstract:
Super-resolution ultrasound imaging relies on the sub-wavelength localization of microbubble contrast agents. By tracking individual microbubbles, the velocity and flow within microvessels can be estimated. However, a 2D super-resolution image can only localize bubbles with sub-wavelength resolution in the imaging plane whereas the resolution in the elevation plane is limited by conventional beamw…
▽ More
Super-resolution ultrasound imaging relies on the sub-wavelength localization of microbubble contrast agents. By tracking individual microbubbles, the velocity and flow within microvessels can be estimated. However, a 2D super-resolution image can only localize bubbles with sub-wavelength resolution in the imaging plane whereas the resolution in the elevation plane is limited by conventional beamwidth physics. Since ultrasound imaging integrates echoes over the elevation dimension, velocity estimates at a single location in the imaging plane include information throughout the imaging slice thickness. This slice thickness is typically a few orders or magnitude larger than the super-resolution limit. It is shown here that in order to estimate the velocity, a spatial integration over the elevation direction must be considered. This operation yields a multiplicative correction factor that compensates for the elevation integration. A correlation-based velocity estimation technique is then presented. Calibrated microtube phantom experiments are used to validate the proposed velocity estimation method and the proposed elevation integration correction factor. It is shown that velocity measurements are in agreement with theoretical predictions within the considered range of flow rates (10 to 90 $μ$L/min). Then, the proposed technique is applied to two in-vivo mouse tail experiments imaged with a low frequency human clinical transducer with human clinical concentrations of microbubbles. In the first experiment, a vein was visible with a diameter of 140 $μ$m and a peak flow velocity of 0.8 mm/s. In the second experiment, a vein was observed in the super-resolved image with a diameter of 120~$μ$m and with maximum local velocity of $\approx$~4.4~mm/s. It is shown that the parabolic flow profiles within these micro-vessels are resolvable.
△ Less
Submitted 29 January, 2020;
originally announced January 2020.