The influence of nuclear models and Monte Carlo radiation transport codes on stray neutron dose estimations in proton therapy
Authors:
M. De Saint-Hubert,
J. Farah,
M. Klodowska,
M. T. Romero-Exposito,
K. Tyminska,
V. Mares,
P. Olko,
L Stolarczyk,
S. Trinkl
Abstract:
This study investigates the influence of several Monte Carlo radiation transport codes and nuclear models on the simulation of secondary neutron spectra and its impact on calculating and measuring neutron doses in proton therapy. Three different multi-purpose Monte Carlo radiation transport codes (FLUKA, MCNPX, Geant4) were used with different available nuclear models to calculate secondary neutro…
▽ More
This study investigates the influence of several Monte Carlo radiation transport codes and nuclear models on the simulation of secondary neutron spectra and its impact on calculating and measuring neutron doses in proton therapy. Three different multi-purpose Monte Carlo radiation transport codes (FLUKA, MCNPX, Geant4) were used with different available nuclear models to calculate secondary neutron energy spectra at various points inside a water tank phantom with PMMA walls using a 10 cm x 10 cm rectangular, mono-energetic proton beam (110, 150, 180, and 210 MeV). Using Kerma approximation secondary neutron doses were calculated applying fluence-to-dose equivalent conversion coefficients in water. Moreover, the impact of varying spectra for electrochemically etched CR39 detector calibration was analyzed for different codes and models. In distal positions beyond the Bragg peak, results show largest variations between the codes, up to 53% for the high energy neutron fluence at 16 cm from the Bragg peak of the 110 MeV proton beam. In lateral positions, the variation between the codes is smaller and for the total neutron fluence within 20%. Variation in the nuclear models in MCNPX was only visible for the proton beam energies of 180 and 210 MeV and modeling the high energy neutron fluence which reached up to 23% for 210 MeV at 11 cm lateral from the beam axis. Impact on neutron dose equivalent was limited for the different models used (<8%) while it was pronounced for the different codes (45% at 16 cm from the Bragg peak of the 110 MeV proton beam). CR39 calibration factors in lateral positions were on average varying 10% between codes and 5 % between nuclear models.This study demonstrated a large impact on the neutron fluence spectra calculated by different codes while the impact of different models in MCNPX proved to be less prominent for the neutron modeling in proton therapy.
△ Less
Submitted 7 December, 2021;
originally announced December 2021.
Fetus dose calculation during proton therapy of pregnant phantoms using MCNPX and MCNP6.2 codes
Authors:
Marijke De Saint-Hubert,
Katarzyna Tyminska,
Liliana Stolarczyk,
Hrvoje Brkic
Abstract:
Radiotherapy of pregnant cancer patients is not common, but when applied accurate assessment of the fetus dose is required, especially since the treatment planning systems are not able and do not allow accurate assessment of out-of-field doses. Proton therapy significantly reduces out-of-field doses, such as dose to the fetus, when compared to the photon radiotherapy techniques and as such could b…
▽ More
Radiotherapy of pregnant cancer patients is not common, but when applied accurate assessment of the fetus dose is required, especially since the treatment planning systems are not able and do not allow accurate assessment of out-of-field doses. Proton therapy significantly reduces out-of-field doses, such as dose to the fetus, when compared to the photon radiotherapy techniques and as such could be promising for pregnant cancer patients. Within this study Monte Carlo calculations are performed on the three different computational phantoms representing pregnant women, all in second trimester of pregnancy. Simplified proton beam to the pregnant women brain was modelled, and the total dose equivalent (normalized per target dose) to the fetus was calculated. Between MCNPX and MCNP6.2 code versions we observed up to 6% difference. In this work 3 groups participated and the variation between the groups was 8% and 12% for MCNPX and MCNP6.2, respectively. Depending on the phantom used in the calculations the fetal dose was between 0.4 and 0.8 μSv/Gy. Major contribution to the total dose came from the neutrons, with only 20% of the dose coming from photons, while other particles have negligible contributions. Results of the total dose equivalent differ by factor of two, when different phantoms were used, due to geometrical and anatomical characteristics of mother and fetus position.
△ Less
Submitted 7 December, 2021;
originally announced December 2021.