Impact of embedded $^{163}$Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experiment
Authors:
Douglas Bennett,
Matteo Borghesi,
Pietro Campana,
Rodolfo Carobene,
Giancarlo Ceruti,
Matteo De Gerone,
Marco Faverzani,
Lorenzo Ferrari Barusso,
Elena Ferri,
Joseph Fowler,
Sara Gamba,
Flavio Gatti,
Andrea Giachero,
Marco Gobbo,
Danilo Labranca,
Roberto Moretti,
Angelo Nucciotti,
Luca Origo,
Stefano Ragazzi,
Dan Schmidt,
Daniel Swetz,
Joel Ullom
Abstract:
We present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $^{163}$Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $^{163}$Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector's energy resolution, signal height,…
▽ More
We present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $^{163}$Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $^{163}$Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector's energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of $^{163}$Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing $^{163}$Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of $^{163}$Ho to be $(2.9 \pm 0.4 \mathrm{(stat)} \pm 0.7 \mathrm{(sys)})$ J/K/mol at $(94 \pm 1)$\,mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with $^{163}$Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate $^{163}$Ho activities up to approximately 5 Bq without significant performance degradation. For higher activities, reducing the TES transition temperature is necessary to maintain energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling implanted radionuclides while maintaining high-resolution performance.
△ Less
Submitted 16 June, 2025;
originally announced June 2025.
-
Future perspectives for $μ^+ \to \mathrm{e}^+ γ$ searches
Authors:
Paolo Walter Cattaneo,
Giovanni Dal Maso,
Matteo De Gerone,
Wataru Ootani,
Atsushi Oya,
Angela Papa,
Francesco Renga,
Andre Schöning
Abstract:
Searches for charged lepton flavor violation in the muon sector stand out among the most sensitive and clean probes for physics beyond the Standard Model. Currently, $μ^+ \to \mathrm{e}^+ γ$ experiments provide the best constraints in this field and, in the coming years, new experiments investigating the processes of $μ^+ \to \mathrm{e^+e^+e^-}$ and $μ\to \mathrm{e}$ conversion in the nuclear fiel…
▽ More
Searches for charged lepton flavor violation in the muon sector stand out among the most sensitive and clean probes for physics beyond the Standard Model. Currently, $μ^+ \to \mathrm{e}^+ γ$ experiments provide the best constraints in this field and, in the coming years, new experiments investigating the processes of $μ^+ \to \mathrm{e^+e^+e^-}$ and $μ\to \mathrm{e}$ conversion in the nuclear field are anticipated to surpass them. However, it is essential to maintain comparable sensitivities across all these processes to fully leverage their potential and differentiate between various new physics models if a discovery occurs. In this document, we present ongoing efforts to develop a future experimental program aimed at improving the sensitivity of \megp\ searches by one order of magnitude within the next decade.
△ Less
Submitted 26 April, 2025;
originally announced April 2025.
-
Most stringent bound on electron neutrino mass obtained with a scalable low temperature microcalorimeter array
Authors:
B. K. Alpert,
M. Balata,
D. T. Becker,
D. A. Bennett,
M. Borghesi,
P. Campana,
R. Carobene,
M. De Gerone,
W. B. Doriese,
M. Faverzani,
L. Ferrari Barusso,
E. Ferri,
J. W. Fowler,
G. Gallucci,
S. Gamba,
J. D. Gard,
F. Gatti,
A. Giachero,
M. Gobbo,
U. Köster,
D. Labranca,
M. Lusignoli,
P. Manfrinetti,
J. A. B. Mates,
E. Maugeri
, et al. (14 additional authors not shown)
Abstract:
The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the Standard Model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. In this Letter, we present the most stringent upper bound on the effective electron…
▽ More
The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the Standard Model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. In this Letter, we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of $^{163}$Ho. The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of $7\times10^7$ decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of $m_β<27$ eV/c$^2$ at 90% credibility. These results validate the feasibility of $^{163}$Ho calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.
△ Less
Submitted 27 March, 2025; v1 submitted 10 March, 2025;
originally announced March 2025.
-
Operation and performance of MEG II detector
Authors:
MEG II Collaboration,
K. Afanaciev,
A. M. Baldini,
S. Ban,
V. Baranov,
H. Benmansour,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
A. Corvaglia,
F. Cuna,
G. Dal Maso,
A. De Bari,
M. De Gerone,
L. Ferrari Barusso,
M. Francesconi,
L. Galli,
G. Gallucci,
F. Gatti,
L. Gerritzen,
F. Grancagnolo
, et al. (60 additional authors not shown)
Abstract:
The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation…
▽ More
The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.
△ Less
Submitted 8 January, 2024; v1 submitted 18 October, 2023;
originally announced October 2023.
-
Measuring the electron neutrino mass using the electron capture decay of 163Ho
Authors:
Joel Ullom,
Daniel Schmidt,
Simon Bandler,
Thomas Stevenson,
Mark Croce,
Katrina Koehler,
Matteo De Gerone,
Loredana Gastaldo,
Christian Enss,
Geonbo Kim,
Angelo Nucciotti,
Stefano Ragazzi,
Kyle Leach,
Diana Parno,
Brian Mong,
Josef Frisch,
Christopher Kenney
Abstract:
While the mass differences between neutrino mass states are known, their absolute masses and mass hierarchy have not yet been determined. Determining the mass of neutrinos provides access to physics beyond the Standard Model and the resulting value has implications for the growth of large-scale structure in the universe over cosmic history. Because of the importance of the topic, a number of effor…
▽ More
While the mass differences between neutrino mass states are known, their absolute masses and mass hierarchy have not yet been determined. Determining the mass of neutrinos provides access to physics beyond the Standard Model and the resulting value has implications for the growth of large-scale structure in the universe over cosmic history. Because of the importance of the topic, a number of efforts are already underway to determine the mass of neutrinos including direct kinematic measurements and indirect measurements of astrophysical phenomena that constrain the sum of the mass eigenstates through models of cosmic evolution. Here, we advocate for a collaborative international effort to perform a kinematic determination of the effective electron neutrino mass using calorimetric measurements of the decay of 163Ho. This effort is justified by the success of current experiments using the technique, its high benefit-to-cost ratio, the value of approaches with different systematic errors, and the value of measuring the electron neutrino mass rather than the electron anti-neutrino mass.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
The Search for $μ^+\to e^+ γ$ with 10$^{-14}$ Sensitivity: the Upgrade of the MEG Experiment
Authors:
The MEG II Collaboration,
Alessandro M. Baldini,
Vladimir Baranov,
Michele Biasotti,
Gianluigi Boca,
Paolo W. Cattaneo,
Gianluca Cavoto,
Fabrizio Cei,
Marco Chiappini,
Gianluigi Chiarello,
Alessandro Corvaglia,
Federica Cuna,
Giovanni dal Maso,
Antonio de Bari,
Matteo De Gerone,
Marco Francesconi,
Luca Galli,
Giovanni Gallucci,
Flavio Gatti,
Francesco Grancagnolo,
Marco Grassi,
Dmitry N. Grigoriev,
Malte Hildebrandt,
Kei Ieki,
Fedor Ignatov
, et al. (45 additional authors not shown)
Abstract:
The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$)…
▽ More
The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$) $<4.2 \times 10^{-13}$ at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of $6\times10^{-14}$. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ($7\times10^{7}$ muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.
△ Less
Submitted 1 September, 2021; v1 submitted 22 July, 2021;
originally announced July 2021.
-
A novel approach for nearly-coincident events rejection
Authors:
M. Borghesi,
M. De Gerone,
M. Faverzani,
M. Fedkevych,
E. Ferri,
G. Gallucci,
A. Giachero,
A. Nucciotti,
A. Puiu
Abstract:
We present a novel technique, called DSVP (Discrimination through Singular Vectors Projections), to discriminate spurious events within a dataset. The purpose of this paper is to lay down a general procedure which can be tailored for a broad variety of applications. After describing the general concept, we apply the algorithm to the problem of identifying nearly coincident events in low temperatur…
▽ More
We present a novel technique, called DSVP (Discrimination through Singular Vectors Projections), to discriminate spurious events within a dataset. The purpose of this paper is to lay down a general procedure which can be tailored for a broad variety of applications. After describing the general concept, we apply the algorithm to the problem of identifying nearly coincident events in low temperature microcalorimeters in order to push the time resolution close to its intrinsic limit. In fact, from simulated datasets it was possible to achieve an effective time resolution even shorter than the sampling time of the system considered. The obtained results are contextualized in the framework of the HOLMES experiment, which aims at directly measuring the neutrino mass with the calorimetric approach, allowing to significally improve its statistical sensitivity.
△ Less
Submitted 7 May, 2021; v1 submitted 7 January, 2021;
originally announced January 2021.
-
Progress in the development of TES microcalorimeter detectors suitable for neutrino mass measurement
Authors:
A. Giachero,
B. Alpert,
D. T. Becker,
D. A. Bennett,
M. Borghesi,
M. De Gerone,
M. Faverzani,
M. Fedkevych,
E. Ferri,
G. Gallucci,
J. D. Gard,
F. Gatti,
G. C. Hilton,
J. A. B. Mates,
A. Nucciotti,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R. Vale
Abstract:
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Tran…
▽ More
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiNx membrane with gold absorbers. Considering the large number of pixels and an event rate of about 300 Hz/pixel, a large multiplexing factor and a large bandwidth are needed. To fulfill this requirement, HOLMES will exploit recent advances in microwave multiplexing. In this contribution, we present the status of the activities in development, the performances of the developed microwave-multiplexed readout system, and the results obtained with the detectors specifically designed for HOLMES in terms of noise, time, and energy resolutions
△ Less
Submitted 7 January, 2021;
originally announced January 2021.
-
Timing resolution of a plastic scintillator counter read out by radiation damaged SiPMs connected in series
Authors:
G. Boca,
P. W. Cattaneo,
M. De Gerone,
F. Gatti,
M. Nakao,
M. Nishimura,
W. Ootani,
M. Rossella,
Y. Uchiyama,
M. Usami,
K. Yanai
Abstract:
This paper discusses the effects of radiation damage to SiPMs on the performances of plastic scintillator counters with series-connected SiPM readout, focusing on timing measurements. The performances of a counter composed of a $120 \times 40 \times5~\mathrm{mm}^3$ scintillator tile read out by two sets of six SiPMs from AdvanSiD connected in series attached on the short sides are presented, for d…
▽ More
This paper discusses the effects of radiation damage to SiPMs on the performances of plastic scintillator counters with series-connected SiPM readout, focusing on timing measurements. The performances of a counter composed of a $120 \times 40 \times5~\mathrm{mm}^3$ scintillator tile read out by two sets of six SiPMs from AdvanSiD connected in series attached on the short sides are presented, for different combinations of SiPMs at various levels of irradiation. Firstly, six SiPMs were equally irradiated with electrons from $^{90}$Sr sources up to a fluence of $Φ_\mathrm{e^-}\approx 3 \times 10^{12}~\mathrm{cm}^{-2}$. The timing resolution of the counter gradually deteriorated by the increase in dark current. The dark current and the deterioration were reduced when the counter was cooled from 30$^\circ$C to 10$^\circ$C. Secondly, 33 SiPMs were irradiated with reactor neutrons. The characteristics of counters read out by series-connected SiPMs with non-uniform damage levels, were investigated. The signal pulse height, the time response, and the timing resolution depend on the hit position in the counter, when SiPMs' irradiation is not uniform.
△ Less
Submitted 9 October, 2020; v1 submitted 11 May, 2020;
originally announced May 2020.
-
Working principle and demonstrator of microwave-multiplexing for the HOLMES experiment microcalorimeters
Authors:
D. T. Becker,
D. A. Bennett,
M. Biasotti,
M. Borghesi,
V. Ceriale,
M. De Gerone,
M. Faverzani,
E. Ferri,
J. W. Fowler,
G. Gallucci,
J. D. Gard,
A. Giachero,
J. P. Hays-Wehle,
G. C. Hilton,
J. A. B Mates,
A. Nucciotti,
A. Orlando,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R Vale
Abstract:
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In…
▽ More
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In order to acquire the large needed statistics, by keeping the pile-up contribution as low as possible, 1024 transition edge sensors (TESs) with high energy and time resolutions will be employed. Microcalorimeter and bolometer arrays based on transition edge sensor with thousands of pixels are under development for several space-based and ground-based applications, including astrophysics, nuclear and particle physics, and materials science. The common necessary challenge is to develop pratical multiplexing techniques in order to simplify the cryogenics and readout systems. Despite the various multiplexing variants which are being developed have been successful, new approaches are needed to enable scaling to larger pixel counts and faster sensors, as requested for HOLMES, reducing also the cost and complexity of readout. A very novel technique that meets all of these requirements is based on superconducting microwave resonators coupled to radio-frequency Superconducting Quantum Interference Devices, in which the the changes in the TES input current is tranduced to a change in phase of a microwave signal. In this work we introduce the basics of this technique, the design and development of the first two-channel read out system and its performances with the first TES detectors specifically designed for HOLMES. In the last part we explain how to extend this approach scaling to 1024 pixels.
△ Less
Submitted 11 October, 2019;
originally announced October 2019.
-
The laser-based time calibration system for the MEG II pixelated Timing Counter
Authors:
G. Boca,
P. W. Cattaneo,
M. De Gerone,
M. Francesconi,
L. Galli,
F. Gatti,
J. Koga,
M. Nakao,
M. Nishimura,
W. Ootani,
M. Rossella,
Y. Uchiyama,
M. Usami,
K. Yanai,
K. Yoshida
Abstract:
We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon photomultipliers (SiPMs). It is difficult to apply previous laser-based calibration methods for conventional meter-scale Time-Of-Flight detectors to the MEG II pTC from the…
▽ More
We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon photomultipliers (SiPMs). It is difficult to apply previous laser-based calibration methods for conventional meter-scale Time-Of-Flight detectors to the MEG II pTC from the implementation and the accuracy points of view. This paper presents a new laser-based time calibration system which can overcome such difficulties. A laser pulse is split into each scintillator counter via several optical components so that we can directly measure the time offset of each counter relative to the laser-emitted time. We carefully tested all the components and procedures prior to the actual operation. The laser system was installed into the pTC and thoroughly tested under the real experimental condition. The system showed good stability and being sensitive to any change of timing larger than ~10 ps. Moreover, it showed an uncertainty of 48 ps in the determination of the time offsets, which meets our requirements. The new method provides an example of the implementation of a precise timing alignment for the new type of detectors enabled by the advance of SiPM technology.
△ Less
Submitted 19 September, 2019; v1 submitted 1 July, 2019;
originally announced July 2019.
-
A Laser-based Time Calibration System for the MEG II Timing Counter
Authors:
M. Nakao,
G. Boca,
P. W. Cattaneo,
M. De Gerone,
F. Gatti,
M. Nishimura,
W. Ootani,
M. Rossella,
Y. Uchiyama,
M. Usami,
K. Yoshida
Abstract:
We have developed a new laser-based time calibration system for the MEG II timing counter dedicated to timing measurement of positrons. The detector requires precise timing alignment between $\sim\,$500 scintillation counters. In this study, we present the calibration system which can directly measure the time offset of each counter relative to the laser-synchronized pulse. We thoroughly tested al…
▽ More
We have developed a new laser-based time calibration system for the MEG II timing counter dedicated to timing measurement of positrons. The detector requires precise timing alignment between $\sim\,$500 scintillation counters. In this study, we present the calibration system which can directly measure the time offset of each counter relative to the laser-synchronized pulse. We thoroughly tested all the optical components and the uncertainty of this method is estimated to be 24 ps. In 2017, we installed the full system into the MEG II environment and performed a commissioning run. This method shows excellent stability and consistency with another method. The proposed system provides a precise timing alignment for SiPM-based timing detectors. It also has potential in areas such as TOF-PET.
△ Less
Submitted 15 May, 2019;
originally announced May 2019.
-
Results from Pilot Run for MEG II Positron Timing Counter
Authors:
M. Nakao,
A. De Bari,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
M. Francesconi,
M. De Gerone,
L. Galli,
F. Gatti,
A. Mtchedilishvili,
D. Nicol,
M. Nishimura,
W. Ootani,
S. Ritt,
M. Rossella,
M. Simonetta,
Y. Uchiyama,
M. Usami
Abstract:
The MEG II experiment at Paul Scherrer Institut in Switzerland will search for the lepton flavour violating muon decay, $μ^+\to e^+γ$, with a sensitivity of $4\times10^{-14}$ improving the existing limit of an order of magnitude. In 2016, we finished the construction of the MEG II Timing Counter, the subdetector dedicated to the measurement of the positron emission time. The first one-fourth of it…
▽ More
The MEG II experiment at Paul Scherrer Institut in Switzerland will search for the lepton flavour violating muon decay, $μ^+\to e^+γ$, with a sensitivity of $4\times10^{-14}$ improving the existing limit of an order of magnitude. In 2016, we finished the construction of the MEG II Timing Counter, the subdetector dedicated to the measurement of the positron emission time. The first one-fourth of it was installed in the experimental area and we performed a pilot run with the MEG~II beam of $7\times10^{7}μ^+/$s. The timing resolution reached the design value improving by a factor of two compared to MEG.
△ Less
Submitted 22 August, 2018;
originally announced August 2018.
-
Status of the HOLMES Experiment to Directly Measure the Neutrino Mass
Authors:
A. Nucciotti,
B. Alpert,
M. Balata,
D. BeckerD. Bennett,
A. Bevilacqua,
M. Biasotti,
V. Ceriale,
G. Ceruti,
D. Corsini,
M. De Gerone,
R. Dressler,
M. Faverzani,
E. Ferri,
J. Fowler,
G. Gallucci,
J. Gard,
F. Gatti,
A. Giachero,
J. Hays-Wehle,
S. Heinitz,
G. Hilton,
U. Köster,
M. Lusignoli,
J. Mates,
S. Nisi
, et al. (13 additional authors not shown)
Abstract:
The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only experimental method which can provide a model independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment funded by the European Research Council to directly measure the neutrino mass…
▽ More
The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only experimental method which can provide a model independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment funded by the European Research Council to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the electron capture decay of the artificial isotope $^{163}$Ho. In a calorimetric measurement the energy released in the decay process is entirely contained into the detector, except for the fraction taken away by the neutrino. This approach eliminates both the issues related to the use of an external source and the systematic uncertainties arising from decays on excited final states. The most suitable detectors for this type of measurement are low temperature thermal detectors, where all the energy released into an absorber is converted into a temperature increase that can be measured by a sensitive thermometer directly coupled with the absorber. This measurement was originally proposed in 1982 by A. De Rujula and M. Lusignoli, but only in the last decade the technological progress in detectors development has allowed to design a sensitive experiment. HOLMES plans to deploy a large array of low temperature microcalorimeters with implanted $^{163}$Ho nuclei. In this contribution we outline the HOLMES project with its physics reach and technical challenges, along with its status and perspectives.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
The design of the MEG II experiment
Authors:
A. M. Baldini,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
C. Chiri,
G. Cocciolo,
A. Corvaglia,
A. de Bari,
M. De Gerone,
A. D'Onofrio,
M. Francesconi,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
D. N. Grigoriev,
M. Hildebrandt
, et al. (55 additional authors not shown)
Abstract:
The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 x 10-14 for the branching ratio, a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation…
▽ More
The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 x 10-14 for the branching ratio, a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation for the upgrade and a detailed overview of the design of the experiment and of the expected detector performance.
△ Less
Submitted 15 January, 2018;
originally announced January 2018.
-
Measuring the electron neutrino mass with improved sensitivity: the HOLMES experiment
Authors:
A. Giachero,
B. Alpert,
D. Becker,
D. Bennett,
M. Biasotti,
C. Brofferio,
V. Ceriale,
G. Ceruti,
D. Corsini,
P. Day,
M. De Gerone,
R. Dressler,
M. Faverzani,
E. Ferri,
J. Fowler,
E. Fumagalli,
G. Gallucci,
J. Gard,
F. Gatti J. Hays-Wehle,
S. Heinitz,
G. Hilton,
U. Koester,
M. Lusignoli,
J. Mates,
S. Nisi
, et al. (17 additional authors not shown)
Abstract:
HOLMES is a new experiment aiming at directly measuring the neutrino mass with a sensitivity below 2 eV. HOLMES will perform a calorimetric measurement of the energy released in the decay of $^{163}$Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with spectrometers. This measurement was proposed in 1982 by A. De…
▽ More
HOLMES is a new experiment aiming at directly measuring the neutrino mass with a sensitivity below 2 eV. HOLMES will perform a calorimetric measurement of the energy released in the decay of $^{163}$Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress has allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted $^{163}$Ho nuclei. HOLMES, besides being an important step forward in the direct neutrino mass measurement with a calorimetric approach, will also establish the potential of this approach to extend the sensitivity down to 0.1 eV and lower. In its final configuration HOLMES will collect about $3\cdot 10^{13}$ decays with 1000 detectors characterized by an instrumental energy resolution of the order of few eV and a time resolution of few microseconds. To embed the $^{163}$Ho into the gold absorbers a custom mass separator ion implanter is being developed. The detectors used for the HOLMES experiment will be Mo/Cu bilayers TESs (Transition Edge Sensors) on SiN$_x$ membrane with gold absorbers. Microwave multiplexed rf-SQUIDs are the best available technique to read out large array of such detectors. An extensive R&D activity is in progress in order to maximize the multiplexing factor while preserving the performances of the individual detectors. The current activities are focused on the the single detector performances optimization and on the $^{163}$Ho isotope production and embedding. A preliminary measurement of a sub-array of $4\times 16$ detectors is planned late in 2017. In this contribution we present the HOLMES project with its technical challenges, its status and perspectives.
△ Less
Submitted 7 March, 2017; v1 submitted 12 December, 2016;
originally announced December 2016.
-
Time resolution of time-of-flight detector based on multiple scintillation counters readout by SiPMs
Authors:
P. W. Cattaneo,
M. De Gerone,
F. Gatti,
M. Nishimura,
W. Ootani,
M. Rossella,
S. Shirabe,
Y. Uchiyama
Abstract:
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $σ_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with multiple counters made of plastic scintillator readout by silicon photomultipliers (SiPMs). The purpose of this work is to demonstrate the time resolution for ~50 MeV…
▽ More
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $σ_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with multiple counters made of plastic scintillator readout by silicon photomultipliers (SiPMs). The purpose of this work is to demonstrate the time resolution for ~50 MeV/c positrons using prototype counters. Counters with dimensions of $90\times 40\times 5~\mathrm{mm}^3$ readout by six SiPMs (three on each $40\times 5~\mathrm{mm}^2$ plane) were built with SiPMs from Hamamatsu Photonics and AdvanSiD and tested in a positron beam at the DA$Φ$NE Beam Test Facility. The time resolution was found to improve nearly as the square root of the number of counter hits. A time resolution $σ_t=26.2\pm1.3~\mathrm{ps}$ was obtained with eight counters with Hamamatsu SiPMs. These results suggest that the design resolution is achievable in the MEG II experiment.
△ Less
Submitted 20 May, 2016; v1 submitted 12 November, 2015;
originally announced November 2015.
-
Muon polarization in the MEG experiment: predictions and measurements
Authors:
A. M. Baldini,
Y. Bao,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
G. Chiarello,
C. Chiri,
A. De Bari,
M. De Gerone,
A. DÓnofrio,
S. Dussoni,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
A. Graziosi,
D. N. Grigoriev,
T. Haruyama,
M. Hildebrandt
, et al. (45 additional authors not shown)
Abstract:
The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stopping target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at…
▽ More
The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stopping target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at the production is predicted to be $P_μ = -1$ by the Standard Model (SM) with massless neutrinos. We estimated our residual muon polarization to be $P_μ = -0.85 \pm 0.03 ~ {\rm (stat)} ~ { }^{+ 0.04}_{-0.05} ~ {\rm (syst)}$ at the stopping target, which is consistent with the SM predictions when the depolarizing effects occurring during the muon production, propagation and moderation in the target are taken into account. The knowledge of beam polarization is of fundamental importance in order to model the background of our ${\megsign}$ search induced by the muon radiative decay: $μ^{+} \rightarrow {\rm e}^{+} \barν_μ ν_{\rm e} γ$.
△ Less
Submitted 28 April, 2016; v1 submitted 15 October, 2015;
originally announced October 2015.
-
HOLMES - The Electron Capture Decay of 163Ho to Measure the Electron Neutrino Mass with sub-eV sensitivity
Authors:
B. Alpert,
M. Balata,
D. Bennett,
M. Biasotti,
C. Boragno,
C. Brofferio,
V. Ceriale,
D. Corsini,
P. K. Day,
M. De Gerone,
R. Dressler,
M. Faverzani,
E. Ferri,
J. Fowler,
F. Gatti,
A. Giachero,
J. Hays-Wehle,
S. Heinitz,
G. Hilton,
U. Koester,
M. Lusignoli,
M. Maino,
J. Mates,
S. Nisi,
R. Nizzolo
, et al. (13 additional authors not shown)
Abstract:
The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of 163Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982…
▽ More
The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of 163Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted 163Ho nuclei. The resulting mass sensitivity will be as low as 0.4 eV. HOLMES will be an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. It will also establish the potential of this approach to extend the sensitivity down to 0.1 eV. We outline here the project with its technical challenges and perspectives.
△ Less
Submitted 17 March, 2015; v1 submitted 16 December, 2014;
originally announced December 2014.
-
Development of High Precision Timing Counter Based on Plastic Scintillator with SiPM Readout
Authors:
Paolo W. Cattaneo,
Matteo De Gerone,
Flavio Gatti,
Miki Nishimura,
Wataru Ootani,
Massimo Rossella,
Yusuke Uchiyama
Abstract:
High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have studied counter sizes up to $120\times40\times5$ mm^3 with series connection of multiple SiPMs to increase the sensitive area and thus achieve better time resol…
▽ More
High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have studied counter sizes up to $120\times40\times5$ mm^3 with series connection of multiple SiPMs to increase the sensitive area and thus achieve better time resolution. A readout scheme with analog shaping and digital waveform analysis is optimized to achieve the highest time resolution. The timing performance is measured using electrons from a Sr-90 radioactive source, comparing different scintillators, counter dimensions, and types of near-ultraviolet sensitive SiPMs. As a result, a resolution of $σ=42 \pm 2$ ps at 1 MeV energy deposition is obtained for counter size $60\times 30 \times 5$ mm^3 with three SiPMs ($3\times3$ mm^2 each) at each end of the scintillator. The time resolution improves with the number of photons detected by the SiPMs. The SiPMs from Hamamatsu Photonics give the best time resolution because of their high photon detection efficiency in the near-ultraviolet region. Further improvement is possible by increasing the number of SiPMs attached to the scintillator.
△ Less
Submitted 11 August, 2014; v1 submitted 6 February, 2014;
originally announced February 2014.
-
Measurement of the radiative decay of polarized muons in the MEG experiment
Authors:
MEG Collaboration,
A. M. Baldini,
Y. Bao,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
G. Chiarello,
C. Chiri,
A. de Bari,
M. De Gerone,
A. D'Onofrio,
S. Dussoni,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
A. Graziosi,
D. N. Grigoriev,
T. Haruyama
, et al. (46 additional authors not shown)
Abstract:
We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV…
▽ More
We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV and E_γ > 40 MeV, consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for $μ^+ \to e^+γ$ process.
△ Less
Submitted 7 March, 2016; v1 submitted 11 December, 2013;
originally announced December 2013.
-
Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results
Authors:
M. De Gerone,
F. Gatti,
W. Ootani,
Y. Uchiyama,
M. Nishimura,
S. Shirabe,
P. W. Cattaneo,
M. Rossella
Abstract:
The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of the single counter elements (SiPMs, scintillators, geometry) is described. Moreover, the results obtained with a first prototype tested at the Beam Test Facili…
▽ More
The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of the single counter elements (SiPMs, scintillators, geometry) is described. Moreover, the results obtained with a first prototype tested at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati (LNF) are presented.
△ Less
Submitted 7 January, 2014; v1 submitted 3 December, 2013;
originally announced December 2013.
-
The MEG detector for $μ+\to e+γ$ decay search
Authors:
J. Adam,
X. Bai,
A. M. Baldini,
E. Baracchini,
C. Bemporad,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
C. Cerri,
M. Corbo,
N. Curalli,
A. De Bari,
M. De Gerone,
L. Del Frate,
S. Doke,
S. Dussoni,
J. Egger,
K. Fratini,
Y. Fujii,
L. Galli,
S. Galeotti,
G. Gallucci,
F. Gatti,
B. Golden
, et al. (51 additional authors not shown)
Abstract:
The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and…
▽ More
The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and the positron momentum, a timing counter for measuring the positron time, and a liquid xenon detector for measuring the photon energy, position and time. The trigger system, the read-out electronics and the data acquisition system are also presented in detail. The paper is completed with a description of the equipment and techniques developed for the calibration in time and energy and the simulation of the whole apparatus.
△ Less
Submitted 10 April, 2013; v1 submitted 10 March, 2013;
originally announced March 2013.
-
New constraint on the existence of the mu+-> e+ gamma decay
Authors:
MEG Collaboration,
J. Adam,
X. Bai,
A. M. Baldini,
E. Baracchini,
C. Bemporad,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
C. Cerri,
A. de Bari,
M. De Gerone,
T. Doke,
S. Dussoni,
J. Egger,
K. Fratini,
Y. Fujii,
L. Galli,
G. Gallucci,
F. Gatti,
B. Golden,
M. Grassi,
A. Graziosi,
D. N. Grigoriev
, et al. (49 additional authors not shown)
Abstract:
The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% conf…
▽ More
The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% confidence level). This represents a four times more stringent limit than the previous world best limit set by MEG.
△ Less
Submitted 23 April, 2013; v1 submitted 4 March, 2013;
originally announced March 2013.
-
MEG Upgrade Proposal
Authors:
A. M. Baldini,
F. Cei,
C. Cerri,
S. Dussoni,
L. Galli,
M. Grassi,
D. Nicolò,
F. Raffaelli,
F. Sergiampietri,
G. Signorelli,
F. Tenchini,
D. Bagliani,
M. De Gerone,
F. Gatti,
E. Baracchini,
Y. Fujii,
T. Iwamoto,
D. Kaneko,
T. Mori,
M. Nishimura,
W. Ootani,
R. Sawada,
Y. Uchiyama,
G. Boca,
P. W. Cattaneo
, et al. (43 additional authors not shown)
Abstract:
We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to ena…
▽ More
We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stopping target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.
△ Less
Submitted 4 February, 2013; v1 submitted 30 January, 2013;
originally announced January 2013.
-
Search for anomalies in the neutrino sector with muon spectrometers and large LArTPC imaging detectors at CERN
Authors:
M. Antonello,
D. Bagliani,
B. Baibussinov,
H. Bilokon,
F. Boffelli,
M. Bonesini,
E. Calligarich,
N. Canci,
S. Centro,
A. Cesana,
K. Cieslik,
D. B. Cline,
A. G. Cocco,
D. Dequal,
A. Dermenev,
R. Dolfini,
M. De Gerone,
S. Dussoni,
C. Farnese,
A. Fava,
A. Ferrari,
G. Fiorillo,
G. T. Garvey,
F. Gatti,
D. Gibin
, et al. (114 additional authors not shown)
Abstract:
A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed in order to definitely clarify the possible existence of additional neutrino states, as pointed out by neutrino calibration source experiments, reactor and accelerator experiments and measure the corresponding oscillation parameters. The experiment is based on two identical LAr-TPCs complemented by magnetized spectromete…
▽ More
A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed in order to definitely clarify the possible existence of additional neutrino states, as pointed out by neutrino calibration source experiments, reactor and accelerator experiments and measure the corresponding oscillation parameters. The experiment is based on two identical LAr-TPCs complemented by magnetized spectrometers detecting electron and muon neutrino events at Far and Near positions, 1600 m and 300 m from the proton target, respectively. The ICARUS T600 detector, the largest LAr-TPC ever built with a size of about 600 ton of imaging mass, now running in the LNGS underground laboratory, will be moved at the CERN Far position. An additional 1/4 of the T600 detector (T150) will be constructed and located in the Near position. Two large area spectrometers will be placed downstream of the two LAr-TPC detectors to perform charge identification and muon momentum measurements from sub-GeV to several GeV energy range, greatly complementing the physics capabilities. This experiment will offer remarkable discovery potentialities, collecting a very large number of unbiased events both in the neutrino and antineutrino channels, largely adequate to definitely settle the origin of the observed neutrino-related anomalies.
△ Less
Submitted 28 September, 2012; v1 submitted 3 August, 2012;
originally announced August 2012.
-
Search for "anomalies" from neutrino and anti-neutrino oscillations at Delta_m^2 ~ 1eV^2 with muon spectrometers and large LAr-TPC imaging detectors
Authors:
M. Antonello,
D. Bagliani,
B. Baibussinov,
H. Bilokon,
F. Boffelli,
M. Bonesini,
E. Calligarich,
N. Canci,
S. Centro,
A. Cesana,
K. Cieslik,
D. B. Cline,
A. G. Cocco,
D. Dequal,
A. Dermenev,
R. Dolfini,
M. De Gerone,
S. Dussoni,
C. Farnese,
A. Fava,
A. Ferrari,
G. Fiorillo,
G. T. Garvey,
F. Gatti,
D. Gibin
, et al. (114 additional authors not shown)
Abstract:
This proposal describes an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN "Far" position. An a…
▽ More
This proposal describes an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN "Far" position. An additional 1/4 of the T600 detector will be constructed and located in the "Near" position. Two spectrometers will be placed downstream of the two LAr-TPC detectors to greatly complement the physics capabilities. Spectrometers will exploit a classical dipole magnetic field with iron slabs, and a new concept air-magnet, to perform charge identification and muon momentum measurements in a wide energy range over a large transverse area. In the two positions, the radial and energy spectra of the nu_e beam are practically identical. Comparing the two detectors, in absence of oscillations, all cross sections and experimental biases cancel out, and the two experimentally observed event distributions must be identical. Any difference of the event distributions at the locations of the two detectors might be attributed to the possible existence of ν-oscillations, presumably due to additional neutrinos with a mixing angle sin^2(2theta_new) and a larger mass difference Delta_m^2_new. The superior quality of the LAr imaging TPC, in particular its unique electron-pi_zero discrimination allows full rejection of backgrounds and offers a lossless nu_e detection capability. The determination of the muon charge with the spectrometers allows the full separation of nu_mu from anti-nu_mu and therefore controlling systematics from muon mis-identification largely at high momenta.
△ Less
Submitted 29 March, 2012; v1 submitted 15 March, 2012;
originally announced March 2012.
-
Development and commissioning of the Timing Counter for the MEG Experiment
Authors:
M. De Gerone,
S. Dussoni,
K. Fratini,
F. Gatti,
R. Valle,
G. Boca,
P. W. Cattaneo,
R. Nardò,
M. Rossella,
L. Galli,
M. Grassi,
D. Nicolò,
Y. Uchiyama,
D. Zanello
Abstract:
The Timing Counter of the MEG (Mu to Electron Gamma) experiment is designed to deliver trigger information and to accurately measure the timing of the $e^+$ in searching for the decay $μ^+ \rightarrow e^+γ$. It is part of a magnetic spectrometer with the $μ^+$ decay target in the center. It consists of two sectors upstream and downstream the target, each one with two layers: the inner one made wit…
▽ More
The Timing Counter of the MEG (Mu to Electron Gamma) experiment is designed to deliver trigger information and to accurately measure the timing of the $e^+$ in searching for the decay $μ^+ \rightarrow e^+γ$. It is part of a magnetic spectrometer with the $μ^+$ decay target in the center. It consists of two sectors upstream and downstream the target, each one with two layers: the inner one made with scintillating fibers read out by APDs for trigger and track reconstruction, the outer one consisting in scintillating bars read out by PMTs for trigger and time measurement. The design criteria, the obtained performances and the commissioning of the detector are presented herein.
△ Less
Submitted 4 February, 2012; v1 submitted 1 December, 2011;
originally announced December 2011.
-
The Timing Counter of the MEG experiment: calibration and performance
Authors:
P. W. Cattaneo,
M. De Gerone,
S. Dussoni,
F. Gatti,
M. Rossella,
Y. Uchiyama,
R. Valle
Abstract:
The MEG detector is designed to test Lepton Flavor Violation in the $μ^+\rightarrow e^+γ$ decay down to a Branching Ratio of a few $10^{-13}$. The decay topology consists in the coincident emission of a monochromatic photon in direction opposite to a monochromatic positron. A precise measurement of the relative time $t_{e^+γ}$ is crucial to suppress the background. The Timing Counter (TC) is desig…
▽ More
The MEG detector is designed to test Lepton Flavor Violation in the $μ^+\rightarrow e^+γ$ decay down to a Branching Ratio of a few $10^{-13}$. The decay topology consists in the coincident emission of a monochromatic photon in direction opposite to a monochromatic positron. A precise measurement of the relative time $t_{e^+γ}$ is crucial to suppress the background. The Timing Counter (TC) is designed to precisely measure the time of arrival of the $e^+$ and to provide information to the trigger system. It consists of two sectors up and down stream the decay target, each consisting of two layers. The outer one made of scintillating bars and the inner one of scintillating fibers. Their design criteria and performances are described.
△ Less
Submitted 6 April, 2011;
originally announced April 2011.