Ultra-fast timing detectors to probe exotic properties of nuclei using RIB facility
Authors:
Ushasi Datta,
S. Chakraborty,
A. Rahaman
Abstract:
Recently, the facilities of radioactive ion beam (RIB) combined with advanced detector systems provide us unique opportunity to probe the exotic properties of the nuclei with unusual neutron-to-proton ratio. In this article, a study of characterization of different types of ultra-fast timing detectors: a special type of gas detector (multi-strip multi-gap resistive plate chamber, MMRPC) ($σ$ $<$10…
▽ More
Recently, the facilities of radioactive ion beam (RIB) combined with advanced detector systems provide us unique opportunity to probe the exotic properties of the nuclei with unusual neutron-to-proton ratio. In this article, a study of characterization of different types of ultra-fast timing detectors: a special type of gas detector (multi-strip multi-gap resistive plate chamber, MMRPC) ($σ$ $<$100 ps), scintillators array ( viz., $LaBr_3:Ce$) (timing resolution ($σ<$250 ps) are being presented. A brief discussion on usage of these different types of ultra-fast timing detector systems at radioactive ion beam facilities is also included.
△ Less
Submitted 15 January, 2016;
originally announced January 2016.
Response of Multi-strip Multi-gap Resistive Plate Chamber
Authors:
Ushasi Datta,
S. Chakraborty,
A. Rahaman,
P. Basu,
J. Basu,
D. Bemmerer,
K. Boretzky,
Z. Elekes,
M. Kempe,
G. Munzenberg,
H. Simon,
M. Sobiella,
D. Stach,
A. Wagner,
D. Yakorev
Abstract:
A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE at Helmholtz-Zentrum Dresden-Rossendorf. In this report the response of SINP developed MMRPC with different controlling parameters is described in details. The…
▽ More
A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE at Helmholtz-Zentrum Dresden-Rossendorf. In this report the response of SINP developed MMRPC with different controlling parameters is described in details. The obtained time resolution ($σ_t$) of the detector after slew correction was 91.5$ \pm $3 ps. Position resolution measured along ($σ_x$) and across ($σ_y$) the strip was 2.8$\pm$0.6 cm and 0.58 cm, respectively. The measured absolute efficiency of the detector for minimum ionizing particle like electron was 95.8$\pm$1.3 $\%$. Better timing resolution of the detector can be achieved by restricting the events to a single strip. The response of the detector was mainly in avalanche mode but a few percentage of streamer mode response was also observed. A comparison of the response of these two modes with trigger rate was studied
△ Less
Submitted 15 January, 2016; v1 submitted 30 April, 2015;
originally announced April 2015.