-
European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment
Authors:
PIONEER Collaboration,
A. Adelmann,
W. Altmannshofer,
S. Ban,
O. Beesley,
A. Bolotnikov,
T. Brunner,
D. Bryman,
Q. Buat,
L. Caminada,
J. Carlton,
S. Chen,
M. Chiu,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
J. Datta,
B. Davis-Purcell,
A. Deshpande,
A. Di Canto,
A. Ebrahimi,
P. Fisher,
S. Foster,
K. Frahm
, et al. (54 additional authors not shown)
Abstract:
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimen…
▽ More
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimental result $R_{e/μ}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/μ}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.
△ Less
Submitted 14 April, 2025; v1 submitted 8 April, 2025;
originally announced April 2025.
-
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
Authors:
A. Kallitsopoulou,
R. Aleksan,
Y. Angelis,
S. Aune,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
D. Desforge,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger
, et al. (27 additional authors not shown)
Abstract:
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon…
▽ More
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.
△ Less
Submitted 29 October, 2024;
originally announced November 2024.
-
Numerical Modelling of Active Target Time Projection Chamber for Low Energy Nuclear Physic
Authors:
Pralay Kumar Das,
Jaydeep Datta,
Nayana Majumdar,
Supratik Mukhopadhyay
Abstract:
A numerical model based on hydrodynamic approach has been developed to emulate the device dynamics of active target Time Projection Chamber which is utilized for studying nuclear reaction through three dimensional tracking of concerned low energy particles. The proposed model has been used to investigate the performance of a prototype active target Time Projection Chamber, namely SAT-TPC, to be fa…
▽ More
A numerical model based on hydrodynamic approach has been developed to emulate the device dynamics of active target Time Projection Chamber which is utilized for studying nuclear reaction through three dimensional tracking of concerned low energy particles. The proposed model has been used to investigate the performance of a prototype active target Time Projection Chamber, namely SAT-TPC, to be fabricated at Saha Institute of Nuclear Physics, for its application in nuclear physics experiments. A case study of non-relativistic elastic scattering $^4He+^{12}C$ with beam energy $25~MeV$ and current $2.3~pA$ has been opted for this purpose. The effect of beam induced space charge on the tracking performance the SAT-TPC prototype has been studied to optimize the beam current and scheme of the anode readout segmentation. The model has been validated by comparing its results to that of a particle model used to explain observed distortion in scattered particle tracks in a low energy nuclear physics experiment.
△ Less
Submitted 24 September, 2024;
originally announced September 2024.
-
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
Authors:
M. Lisowska,
R. Aleksan,
Y. Angelis,
S. Aune,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Dehmelt,
G. Fanourakis,
S. Ferry,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
C. C. Lai,
P. Legou
, et al. (33 additional authors not shown)
Abstract:
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for…
▽ More
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.
△ Less
Submitted 9 December, 2024; v1 submitted 13 July, 2024;
originally announced July 2024.
-
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
Authors:
X. Wang,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Degmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
I. Maniatis
, et al. (26 additional authors not shown)
Abstract:
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bomb…
▽ More
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.
△ Less
Submitted 30 July, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
-
Single channel PICOSEC Micromegas detector with improved time resolution
Authors:
A. Utrobicic,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Dehmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger
, et al. (25 additional authors not shown)
Abstract:
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing perfo…
▽ More
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Prediction of Energy Resolution in the JUNO Experiment
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Kai Adamowicz,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Marco Beretta,
Antonio Bergnoli,
Daniel Bick
, et al. (629 additional authors not shown)
Abstract:
This paper presents an energy resolution study of the JUNO experiment, incorporating the latest knowledge acquired during the detector construction phase. The determination of neutrino mass ordering in JUNO requires an exceptional energy resolution better than 3\% at 1~MeV. To achieve this ambitious goal, significant efforts have been undertaken in the design and production of the key components o…
▽ More
This paper presents an energy resolution study of the JUNO experiment, incorporating the latest knowledge acquired during the detector construction phase. The determination of neutrino mass ordering in JUNO requires an exceptional energy resolution better than 3\% at 1~MeV. To achieve this ambitious goal, significant efforts have been undertaken in the design and production of the key components of the JUNO detector. Various factors affecting the detection of inverse beta decay signals have an impact on the energy resolution, extending beyond the statistical fluctuations of the detected number of photons, such as the properties of the liquid scintillator, performance of photomultiplier tubes, and the energy reconstruction algorithm. To account for these effects, a full JUNO simulation and reconstruction approach is employed. This enables the modeling of all relevant effects and the evaluation of associated inputs to accurately estimate the energy resolution. The results of study reveal an energy resolution of 2.95\% at 1~MeV. Furthermore, this study assesses the contribution of major effects to the overall energy resolution budget. This analysis serves as a reference for interpreting future measurements of energy resolution during JUNO data collection. Moreover, it provides a guideline for comprehending the energy resolution characteristics of liquid scintillator-based detectors.
△ Less
Submitted 9 January, 2025; v1 submitted 28 May, 2024;
originally announced May 2024.
-
Numerical simulation of charging up, accumulation of space charge and formation of discharges
Authors:
Purba Bhattacharya,
Promita Roy,
Tanay Dey,
Jaydeep Datta,
Prasant K. Rout,
Nayana Majumdar,
Supratik Mukhopadhyay
Abstract:
Aging and stability of gaseous ionization detectors are intricately related to charging up, accumulation of space charge and formation of discharges. All these phenomena, in their turn, depend on the dynamics of charged particles within the device. Because of the large number of particles involved and their complex interactions, the dynamic processes of generation and loss of charged particles, an…
▽ More
Aging and stability of gaseous ionization detectors are intricately related to charging up, accumulation of space charge and formation of discharges. All these phenomena, in their turn, depend on the dynamics of charged particles within the device. Because of the large number of particles involved and their complex interactions, the dynamic processes of generation and loss of charged particles, and their transport within the detector volume are extremely expensive to simulate numerically. In this work, we propose and evaluate possible algorithms / approaches that show some promise in relation to the above-mentioned problems. Several important ionization detectors having parallel plate configurations, such as GEM, Micromegas, RPCs and THGEMs, are considered for this purpose. Information related to primary ionization is obtained from HEED, while all the transport properties are evaluated using MAGBOLTZ. The transport dynamics have been followed using two different approaches. In one, particle description using neBEM-Garfield++ combination has been used. For this purpose, the neBEM solver has been significantly improved such that perturbations due to the charged particles present within the device are considered while estimating electric field. In the other approach, the transport is simulated following hydrodynamic model using COMSOL during which the electric field is also provided by COMSOL where it is easy to set up space charge effects. A comparison between these possible approaches will be presented. Effect of different simulation parameters will also be demonstrated using simple examples.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Fabrication of $^{108}$Cd target for the astrophysical p-process studies
Authors:
Sukhendu Saha,
Mousri Paul,
Lalit Kumar Sahoo,
Dipali Basak,
Tanmoy Bar,
Jagannath Datta,
Sandipan Dasgupta,
G. L. N. Reddy,
Chinmay Basu
Abstract:
The detailed process of preparing enriched $^{108}$Cd targets on mylar and copper backing using the vacuum evaporation technique is described. These targets were employed in an experiment to measure the proton capture cross-section at energies significantly below the Coulomb barrier, for the astrophysical p-process studies. Due to the low melting point and high vapor pressure of cadmium, some adju…
▽ More
The detailed process of preparing enriched $^{108}$Cd targets on mylar and copper backing using the vacuum evaporation technique is described. These targets were employed in an experiment to measure the proton capture cross-section at energies significantly below the Coulomb barrier, for the astrophysical p-process studies. Due to the low melting point and high vapor pressure of cadmium, some adjustments were implemented in the Telemark multipocket e-beam setup. The target thickness was determined through the measurement of alpha particle energy loss from a triple alpha source and also by RBS measurements. The thickness of the $^{108}$Cd films varies between 290 to 660 $μ$g/cm$^2$, with a non-uniformity of approximately 10$\%$. X-ray Photoelectron Spectroscopy (XPS) and X-ray Fluorescence (XRF) analyses were conducted to examine the presence of impurities and to assess surface morphology, phase, and chemical composition.
△ Less
Submitted 19 January, 2024;
originally announced February 2024.
-
Transferable and Robust Machine Learning Model for Predicting Stability of Si Anodes for Multivalent Cation Batteries
Authors:
Joy Datta,
Dibakar Datta,
Vidushi Sharma
Abstract:
Data-driven methodology has become a key tool in computationally predicting material properties. Currently, these techniques are priced high due to computational requirements for generating sufficient training data for high-precision machine learning models. In this study, we present a Support Vector Regression (SVR)-based machine learning model to predict the stability of silicon (Si) - alkaline…
▽ More
Data-driven methodology has become a key tool in computationally predicting material properties. Currently, these techniques are priced high due to computational requirements for generating sufficient training data for high-precision machine learning models. In this study, we present a Support Vector Regression (SVR)-based machine learning model to predict the stability of silicon (Si) - alkaline metal alloys, with a strong emphasis on the transferability of the model to new silicon alloys with different electronic configurations and structures. We elaborate on the role of the structural descriptor in imparting transferability to the model that is trained on limited data (~750 Si alloys) derived from the Material Project database. Three popular descriptors, namely X-Ray Diffraction (XRD), Sine Coulomb Matrix (SCM), and Orbital Field Matrix (OFM), are evaluated for representing Si alloys. The material structures are represented by descriptors in the SVR model, coupled with hyperparameter tuning techniques like Grid Search CV and Bayesian Optimization (BO), to find the best performing model for predicting total energy, formation energy and packing fraction of the Si alloy systems. The models are trained on Si alloys with lithium (Li), sodium (Na), potassium (K), magnesium (Mg), calcium (Ca), and aluminum (Al) metals, where Si-Na and Si-Al systems are used as test structures. Our results show that XRD, an experimentally derived characterization of structures, performs most reliably as a descriptor for total energy prediction of new Si alloys. The study demonstrates that by qualitatively selection of training data, using hyperparameter tuning methods, and employing appropriate structural descriptors, the data requirements for robust and accurate ML models can be reduced.
△ Less
Submitted 25 June, 2023;
originally announced June 2023.
-
Data acquisition system for muon tracking in a muon scattering tomography setup
Authors:
Subhendu Das,
Sridhar Tripathy,
Jaydeep Datta,
Sandip Sarkar,
Nayana Majumdar,
Supratik Mukhopadhyay
Abstract:
We report here the development of a multi-channel DAQ system for muon tracking in a muon scattering tomography setup. The salient features of the proposed DAQ system are direct acquisition and processing of LVDS signals, 500 MHz sampling frequency and scalability. It consists of front-end electronics stage built around NINO ASIC. The back-end electronics is configured with Intel/Altera MAX-10 FPGA…
▽ More
We report here the development of a multi-channel DAQ system for muon tracking in a muon scattering tomography setup. The salient features of the proposed DAQ system are direct acquisition and processing of LVDS signals, 500 MHz sampling frequency and scalability. It consists of front-end electronics stage built around NINO ASIC. The back-end electronics is configured with Intel/Altera MAX-10 FPGA development board which transmits data to the storage following UART protocol. The proposed DAQ system has been tested for its performance using a position sensitive glass RPC detector with two-dimensional 8X8 readout strip configuration.
△ Less
Submitted 27 May, 2023;
originally announced May 2023.
-
JUNO sensitivity to $^7$Be, $pep$, and CNO solar neutrinos
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Marco Beretta
, et al. (592 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented levels of precision. In this paper, we provide estimation of the JUNO sensitivity to 7Be, pep, and CNO solar neutrinos that can be obtained via a spectral analysis above the 0.45 MeV threshold. This study is performed assuming different scenarios of the liquid scintillator radiopurity, ranging from the most opti mistic one corresponding to the radiopurity levels obtained by the Borexino experiment, up to the minimum requirements needed to perform the neutrino mass ordering determination with reactor antineutrinos - the main goal of JUNO. Our study shows that in most scenarios, JUNO will be able to improve the current best measurements on 7Be, pep, and CNO solar neutrino fluxes. We also perform a study on the JUNO capability to detect periodical time variations in the solar neutrino flux, such as the day-night modulation induced by neutrino flavor regeneration in Earth, and the modulations induced by temperature changes driven by helioseismic waves.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
Calculation of true coincidence summing correction factor for a Broad Energy Germanium (BEGe) detector using standard and fabricated sources
Authors:
Ashish Gupta,
M. Shareef,
Munmun Twisha,
Saikat Bhattacharjee,
Gopal Mukherjee,
Satya Samiran Nayak,
Sansaptak Basu,
S. Dasgupta,
J. Datta,
S. Bhattacharyya,
A. Mukherjee
Abstract:
The true coincidence summing (TCS) correction factor for a Broad Energy Germanium (BEGe) detector has been calculated at far and close geometry measurement using multi-energetic radioactive $γ$-ray sources $^{60}$Co, $^{133}$Ba and $^{152}$Eu. The correction factors were calculated using experimental method and analytical method. Photopeak efficiency and total efficiency required to calculate the…
▽ More
The true coincidence summing (TCS) correction factor for a Broad Energy Germanium (BEGe) detector has been calculated at far and close geometry measurement using multi-energetic radioactive $γ$-ray sources $^{60}$Co, $^{133}$Ba and $^{152}$Eu. The correction factors were calculated using experimental method and analytical method. Photopeak efficiency and total efficiency required to calculate the correction factor were obtained using Geant4 Monte Carlo simulation code. A few standard as well as fabricated mono-energetic sources were also included in the $γ$-ray efficiency measurements. The simulated efficiencies of mono-energetic $γ$-ray sources were matched to experimental $γ$-ray efficiencies by optimizing the detector parameters. The same parameters were used to obtain the photopeak and total efficiency for $γ$-ray of our interest and coincident $γ$-ray. Analytical correction factors and experimental correction factors were found in good agreement with each other.
△ Less
Submitted 6 February, 2023;
originally announced February 2023.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Study of space charge phenomena in GEM-based detectors
Authors:
Promita Roy,
Prasant Kumar Rout,
Jaydeep Datta,
Purba Bhattacharya,
Supratik Mukhopadhyay,
Nayana Majumdar,
Sandip Sarkar
Abstract:
Space charge accumulation within GEM holes is one of the vital phenomena which affects many of the key working parameters of the detector. This accumulation is found to be significantly affected by the initial primary charge configurations and applied GEM voltages since they determine charge sharing and the subsequent evolution of detector response. In this work, we have studied the effects of spa…
▽ More
Space charge accumulation within GEM holes is one of the vital phenomena which affects many of the key working parameters of the detector. This accumulation is found to be significantly affected by the initial primary charge configurations and applied GEM voltages since they determine charge sharing and the subsequent evolution of detector response. In this work, we have studied the effects of space charge phenomena on different parameters for single GEM detectors using a hybrid numerical model.
△ Less
Submitted 21 September, 2022;
originally announced September 2022.
-
Studies on Electrical Properties of Resistive Plate Chamber (RPC)
Authors:
Subhendu Das,
Jaydeep Datta,
Nayana Majumdar,
Supratik Mukhopadhyay
Abstract:
A numerical model based on Finite Element Method (FEM) has been developed to simulate the electrical properties of RPC utilizing the law of current conservation. It has been used to systematically investigate the effect of the electrical as well as the geometrical parameters of the device components on the potential distribution and field configuration which govern the RPC performance. The numeric…
▽ More
A numerical model based on Finite Element Method (FEM) has been developed to simulate the electrical properties of RPC utilizing the law of current conservation. It has been used to systematically investigate the effect of the electrical as well as the geometrical parameters of the device components on the potential distribution and field configuration which govern the RPC performance. The numerical model has been validated by comparing the dark current and electric field with those produced by another mathematical model based on surface currents. The efficacy of the present model has been demonstrated by comparing its results to the experimental measurements performed with a glass RPC. The measured and estimated values of these observables have been found to be in good agreement.
△ Less
Submitted 20 September, 2022; v1 submitted 27 April, 2022;
originally announced April 2022.
-
Numerical calculation of RPC time resolution
Authors:
Jaydeep Datta,
Nayana Majumdar,
Supratik Mukhopadhyay,
Sandip Sarkar
Abstract:
Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the time resolution of RPC is dependent on the detector geometry, applied voltage and the gas mixture used for detector operation. In this work, we have tried to devel…
▽ More
Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the time resolution of RPC is dependent on the detector geometry, applied voltage and the gas mixture used for detector operation. In this work, we have tried to develop a numerical model to estimate the time resolution of the detector. The model is developed using COMSOL Multiphysics, a commercially available finite element method solver. Using the primary ionization information from HEED and the electron transport properties from MAGBOLTZ, the model solves the Boltzmann equations to simulate the avalanche in the detector and finds the time to cross a previously determined threshold current, which is used to measure the time resolution of the detector.
△ Less
Submitted 25 April, 2022;
originally announced April 2022.
-
Numerical estimation of discharge probability in GEM-based detectors
Authors:
Prasant Kumar Rout,
R. Kanishka,
Jaydeep Datta,
Promita Roy,
Purba Bhattacharya,
Supratik Mukhopadhyay,
Nayana Majumdar,
Sandip Sarkar
Abstract:
Discharge probability in GEM-based gaseous detectors has been numerically estimated using an axisymmetric hydrodynamic model. Initial primary charge configurations in the drift region, obtained using Heed and Geant4, are found to have significant effect on the subsequent evolution of detector response. Simulation of energy resolution has been performed to establish the capability of the hydrodynam…
▽ More
Discharge probability in GEM-based gaseous detectors has been numerically estimated using an axisymmetric hydrodynamic model. Initial primary charge configurations in the drift region, obtained using Heed and Geant4, are found to have significant effect on the subsequent evolution of detector response. Simulation of energy resolution has been performed to establish the capability of the hydrodynamic model to capture statistical nature of the experimental situation. Finally, single and triple GEM configurations exposed to alpha sources have been simulated to estimate discharge probability which have been compared with available experimental data. Despite the simplifying and drastic assumptions in the numerical model, the comparisons are encouraging.
△ Less
Submitted 13 August, 2021; v1 submitted 23 March, 2021;
originally announced March 2021.
-
Numerical Qualification of Eco-Friendly Gas Mixtures for Avalanche-Mode Operation of Resistive Plate Chambers in INO-ICAL
Authors:
Jaydeep Datta,
Sridhar Tripathy,
Nayana Majumdar,
Supratik Mukhopadhyay
Abstract:
Numerical qualification of an eco-friendly alternative gas mixture for avalanche mode operation of Resistive Plate Chambers is the soul of this work. To identify the gas mixture, a numerical model developed elsewhere by the authors has been first established by comparing the simulated figure of merits (efficiency and streamer probability) with the experimental data for the gas mixture used in INO-…
▽ More
Numerical qualification of an eco-friendly alternative gas mixture for avalanche mode operation of Resistive Plate Chambers is the soul of this work. To identify the gas mixture, a numerical model developed elsewhere by the authors has been first established by comparing the simulated figure of merits (efficiency and streamer probability) with the experimental data for the gas mixture used in INO-ICAL. Then it has been used to simulate the same properties of a gas mixture based on argon, carbon di-oxide and nitrogen, identified as potential replacement by studying its different properties. Efficacy of this eco-friendly gas mixture has been studied by comparing the simulated result with the standard gas mixture used in INO-ICAL as well as with experimental data of other eco-friendly hydrofluorocarbon (HFO1234ze) based potential replacements. To increase the efficacy of the proposed gas mixture, studies of the traditional way (addition of a little amount of SF$_6$) and an alternative approach (exploring the option of high-end electronics) were carried out.
△ Less
Submitted 3 May, 2021; v1 submitted 2 March, 2021;
originally announced March 2021.
-
Numerical Evaluation of a muon tomography system for imaging defects in concrete structures
Authors:
Sridhar Tripathy,
Jaydeep Datta,
Nayana Majumdar,
Supratik Mukhopadhyay
Abstract:
Among numerous applications of muon tomography, deployment in civil structures has caught attraction of many recently. In this work, the appropriateness of muon scattering tomography to detect defects in concrete structures has been studied numerically. A few basic concrete structures that are frequently used in civil construction, have been considered as test cases. A simulation has been performe…
▽ More
Among numerous applications of muon tomography, deployment in civil structures has caught attraction of many recently. In this work, the appropriateness of muon scattering tomography to detect defects in concrete structures has been studied numerically. A few basic concrete structures that are frequently used in civil construction, have been considered as test cases. A simulation has been performed on Geant4 platform where an imaging setup built with several gaseous ionization detectors, having a specific spatial resolution for tracking the muons, have been modeled. The images of the test cases with and without the defect have been simulated for a month-long exposure of cosmic muons on the basis of their scattering from the composite concrete structures. The images have been compared using t-test to evaluate the performance of the imaging setup in identifying the defects. Further processing of the images has been done with a pattern recognition method proposed in our earlier work to improve defect identification. The efficacy of the said method has been evaluated in terms of the PRM-score devised in this work. The limitation and advantages of the present application of the muon scattering tomography encompassing the imaging and image processing technique in non-destructive evaluation of concrete structures have been discussed.
△ Less
Submitted 22 March, 2021; v1 submitted 17 February, 2021;
originally announced February 2021.
-
Fast simulation of avalanche and streamer in GEM detector using hydrodynamic approach
Authors:
Prasant Kumar Rout,
Jaydeep Datta,
Promita Roy,
Purba Bhattacharya,
Supratik Mukhopadhyay,
Nayana Majumdar,
Sandip Sarkar
Abstract:
A fast, hydrodynamic numerical model has been developed on the COMSOL Multi-physics platform to simulate the evolution and dynamics of charged particles in gaseous ionization detectors based on the Gaseous Electron Multipliers (GEM). Effects of using two-dimensional (2D), 2D axisymmetric and three-dimensional(3D) models of the detectors have been analyzed to choose the optimum configuration. The c…
▽ More
A fast, hydrodynamic numerical model has been developed on the COMSOL Multi-physics platform to simulate the evolution and dynamics of charged particles in gaseous ionization detectors based on the Gaseous Electron Multipliers (GEM). Effects of using two-dimensional (2D), 2D axisymmetric and three-dimensional(3D) models of the detectors have been analyzed to choose the optimum configuration. The chosen model has been used to follow the entire operating regime of single, double and triple GEM detectors, including avalanche and streamer mode operations. The accumulation of space charge, its contribution towards the distortion of the applied electric field and production of streamers have been investigated in fair detail using the optimized model.
△ Less
Submitted 15 December, 2020; v1 submitted 5 November, 2020;
originally announced November 2020.
-
Study of Streamer Development in Resistive Plate Chamber
Authors:
Jaydeep Datta,
Sridhar Tripathy,
Nayana Majumdar,
Supratik Mukhopadhyay
Abstract:
This work has been carried out to simulate a Resistive Plate Chamber and corroborate it with experimental measurements in order to develop a numerical tool for studying the performance of the device for any gas mixture. This will allow us to explore the feasibility of operating these chambers in their avalanche mode within the Iron Calorimeter setup at India-based Neutrino Observatory with any eco…
▽ More
This work has been carried out to simulate a Resistive Plate Chamber and corroborate it with experimental measurements in order to develop a numerical tool for studying the performance of the device for any gas mixture. This will allow us to explore the feasibility of operating these chambers in their avalanche mode within the Iron Calorimeter setup at India-based Neutrino Observatory with any eco-friendly substitute. The simulation has considered a hydrodynamic model of charge transport to emulate the electronic and ionic growths in the device as a function of the applied voltage which determines its working mode as either of the avalanche or streamer. In order to validate, the simulation result has been compared with compatible experimental data available in the literature.
△ Less
Submitted 20 November, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Precise Tracking of Cosmic Muons using Time over Threshold property of NINO ASICs
Authors:
Sridhar Tripathy,
Subhendu Das,
Jaydeep Datta,
Nayana Majumdar,
Supratik Mukhopadhyay
Abstract:
This work reports a cost-effective, simple front-end readout and DAQ of a RPC-based muon scattering tomography system under construction. The Time-over-threshold property of NINO ASICs has been exploited to achieve precise tracking by extraction of position information. The use of a low-cost FPGA for event selection and TOT measurement has been demonstrated for a prototype RPC which has been trigg…
▽ More
This work reports a cost-effective, simple front-end readout and DAQ of a RPC-based muon scattering tomography system under construction. The Time-over-threshold property of NINO ASICs has been exploited to achieve precise tracking by extraction of position information. The use of a low-cost FPGA for event selection and TOT measurement has been demonstrated for a prototype RPC which has been triggered by a cosmic ray hodoscope of three plastic scintillators. The relation between input pulse width and TOT has been established by analyzing the waveforms of the RPC signals. The TOT profile at different working voltages has been obtained by the FPGA and it has been fitted with the Gaussian distribution. Its standard deviation represents an estimate of the tracking precision.
△ Less
Submitted 28 May, 2020; v1 submitted 30 April, 2020;
originally announced April 2020.
-
Material Discrimination in Cosmic Muon Imaging using Pattern Recognition Method
Authors:
Sridhar Tripathy,
Jaydeep Datta,
Nayana Majumdar,
Supratik Mukhopadhyay
Abstract:
This work reports numerical simulations and statistical tests carried out to study the performance of a prototype imaging setup to be developed for material discrimination using Muon Scattering Tomography (MST). The reconstructed images have been processed with a Pattern Recognition Method (PRM) to discriminate the low-Z and high-Z materials. The same method has been applied to examine the perform…
▽ More
This work reports numerical simulations and statistical tests carried out to study the performance of a prototype imaging setup to be developed for material discrimination using Muon Scattering Tomography (MST). The reconstructed images have been processed with a Pattern Recognition Method (PRM) to discriminate the low-Z and high-Z materials. The same method has been applied to examine the performance of the setup in recognizing the shape of the test objects. Design parameters of the setup, such as area of the muon detectors, their physical placement, along with their spatial resolution, etc. have been discussed. To evaluate the efficacy of the newly proposed PRM, the results have been compared to another technique based on cluster finding.
△ Less
Submitted 2 May, 2020; v1 submitted 11 March, 2020;
originally announced March 2020.
-
Material Identification with Cosmic Ray Muons using RPCs
Authors:
Sridhar Tripathy,
Jaydeep Datta,
Abhik Jash,
Subhadip Bouri,
Nayana Majumdar,
Supratik Mukhopadhyay,
Sandip Sarkar
Abstract:
We plan to build an imaging setup for material identification utilizing the Coulomb scattering of cosmic ray muons due to their interaction with the materials and tracking their trajectories with RPCs. To begin with, we consider a setup of six RPCs stacked in a parallel manner to read the position and timing information of the muons before and after their interaction with a phantom of a given mate…
▽ More
We plan to build an imaging setup for material identification utilizing the Coulomb scattering of cosmic ray muons due to their interaction with the materials and tracking their trajectories with RPCs. To begin with, we consider a setup of six RPCs stacked in a parallel manner to read the position and timing information of the muons before and after their interaction with a phantom of a given material using a set of three RPCs for each phase. Here we present a simulation work carried out to study the image formation of the phantom of several materials using the present setup. A detailed modeling of the imaging system consisting of six RPCs was done using GEANT4. Cosmic Ray Library (CRY) was used for generation of particles with the appropriate distribution of energies and momenta. Three reconstruction algorithms were followed for material identification and image reconstruction, viz. Point of Closest Approach (POCA), Iterative POCA and the Binned Clustering Algorithm. A weighted metric discriminator was calculated for target object identification. Using the algorithms, the imaging of the area of interest lying between the two layers of RPCs was done. The time required to discriminate target objects and do the image reconstruction has been studied.
△ Less
Submitted 10 June, 2018;
originally announced June 2018.
-
Covalently bound Bovine Serum Albumin (BSA) protein modified Hydrogenated Diamond Like Carbon (HDLC) surface as biosensor application
Authors:
Hari Shankar Biswasa,
Kausik Gupta,
Jagannath Datta,
Uday Chand Ghosh,
Nihar Ranjan Ray
Abstract:
We have developed a biosensor based on BSA with the help of metal ions binding mechanism to detect and remove inorganic As(III), Cu(II), Pb(II) from water like fishing by hooking system.
We have developed a biosensor based on BSA with the help of metal ions binding mechanism to detect and remove inorganic As(III), Cu(II), Pb(II) from water like fishing by hooking system.
△ Less
Submitted 2 April, 2014;
originally announced April 2014.