Ultra-High precision Compton polarimetry at 2 GeV
Authors:
A. Zec,
S. Premathilake,
J. C. Cornejo,
M. M. Dalton,
C. Gal,
D. Gaskell,
M. Gericke,
I. Halilovic,
H. Liu,
J. Mammei,
R. Michaels,
C. Palatchi,
J. Pan,
K. D. Paschke,
B. Quinn,
J. Zhang
Abstract:
We report a high precision measurement of electron beam polarization using Compton polarimetry. The measurement was made in experimental Hall A at Jefferson Lab during the CREX experiment in 2020. A total uncertainty of dP/P=0.36% was achieved detecting the back-scattered photons from the Compton scattering process. This is the highest accuracy in a measurement of electron beam polarization using…
▽ More
We report a high precision measurement of electron beam polarization using Compton polarimetry. The measurement was made in experimental Hall A at Jefferson Lab during the CREX experiment in 2020. A total uncertainty of dP/P=0.36% was achieved detecting the back-scattered photons from the Compton scattering process. This is the highest accuracy in a measurement of electron beam polarization using Compton scattering ever reported, surpassing the ground-breaking measurement from the SLAC Large Detector (SLD) Compton polarimeter. Such uncertainty reaches the level required for the future flagship measurements to be made by the MOLLER and SoLID experiments.
△ Less
Submitted 25 February, 2024;
originally announced February 2024.
-
Activity Report of the Second African Conference on Fundamental and Applied Physics, ACP2021
Authors:
Kétévi A. Assamagan,
Obinna Abah,
Amare Abebe,
Stephen Avery,
Diallo Boye,
Arame Boye-Faye,
Kenneth Cecire,
Mohamed Chabab,
Samuel Chigome,
Simon Connell,
Marie Chantal Cyulinyana,
Mark Macrae Dalton,
Christine Darve,
Lalla Btissam Drissi,
Farida Fassi,
Ulrich Goelach,
Mohamed Gouighri,
Paul Gueye,
Sonia Haddad,
Bjorn von der Heyden,
Oumar Ka,
Gihan Kamel,
Stéphane Kenmoe,
Diouma Kobor,
Tjaart Krüger
, et al. (16 additional authors not shown)
Abstract:
The African School of Fundamental Physics and Applications, also known as the African School of Physics (ASP), was initiated in 2010, as a three-week biennial event, to offer additional training in fundamental and applied physics to African students with a minimum of three-year university education. Since its inception, ASP has grown to be much more than a school. ASP has become a series of activi…
▽ More
The African School of Fundamental Physics and Applications, also known as the African School of Physics (ASP), was initiated in 2010, as a three-week biennial event, to offer additional training in fundamental and applied physics to African students with a minimum of three-year university education. Since its inception, ASP has grown to be much more than a school. ASP has become a series of activities and events with directed ethos towards physics as an engine for development in Africa. One such activity of ASP is the African Conference on Fundamental and Applied Physics (ACP). The first edition of ACP took place during the 2018 edition of ASP at the University of Namibia in Windhoek. In this paper, we report on the second edition of ACP, organized on March 7--11, 2022, as a virtual event.
△ Less
Submitted 6 April, 2022; v1 submitted 4 April, 2022;
originally announced April 2022.
-
The GlueX Beamline and Detector
Authors:
S. Adhikari,
C. S. Akondi,
H. Al Ghoul,
A. Ali,
M. Amaryan,
E. G. Anassontzis,
A. Austregesilo,
F. Barbosa,
J. Barlow,
A. Barnes,
E. Barriga,
R. Barsotti,
T. D. Beattie,
J. Benesch,
V. V. Berdnikov,
G. Biallas,
T. Black,
W. Boeglin,
P. Brindza,
W. J. Briscoe,
T. Britton,
J. Brock,
W. K. Brooks,
B. E. Cannon,
C. Carlin
, et al. (165 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based…
▽ More
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μ$s. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
△ Less
Submitted 26 October, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab -- 2018 update to PR12-16-001
Authors:
M. Battaglieri,
A. Bersani,
G. Bracco,
B. Caiffi,
A. Celentano,
R. De Vita,
L. Marsicano,
P. Musico,
F. Panza,
M. Ripani,
E. Santopinto,
M. Taiuti,
V. Bellini,
M. Bondi',
P. Castorina,
M. De Napoli,
A. Italiano,
V. Kuznetzov,
E. Leonora,
F. Mammoliti,
N. Randazzo,
L. Re,
G. Russo,
M. Russo,
A. Shahinyan
, et al. (100 additional authors not shown)
Abstract:
This document complements and completes what was submitted last year to PAC45 as an update to the proposal PR12-16-001 "Dark matter search in a Beam-Dump eXperiment (BDX)" at Jefferson Lab submitted to JLab-PAC44 in 2016. Following the suggestions contained in the PAC45 report, in coordination with the lab, we ran a test to assess the beam-related backgrounds and validate the simulation framework…
▽ More
This document complements and completes what was submitted last year to PAC45 as an update to the proposal PR12-16-001 "Dark matter search in a Beam-Dump eXperiment (BDX)" at Jefferson Lab submitted to JLab-PAC44 in 2016. Following the suggestions contained in the PAC45 report, in coordination with the lab, we ran a test to assess the beam-related backgrounds and validate the simulation framework used to design the BDX experiment. Using a common Monte Carlo framework for the test and the proposed experiment, we optimized the selection cuts to maximize the reach considering simultaneously the signal, cosmic-ray background (assessed in Catania test with BDX-Proto) and beam-related backgrounds (irreducible NC and CC neutrino interactions as determined by simulation). Our results confirmed what was presented in the original proposal: with 285 days of a parasitic run at 65 $μ$A (corresponding to $10^{22}$ EOT) the BDX experiment will lower the exclusion limits in the case of no signal by one to two orders of magnitude in the parameter space of dark-matter coupling versus mass.
△ Less
Submitted 8 October, 2019;
originally announced October 2019.
-
Construction and Performance of the Barrel Electromagnetic Calorimeter for the GlueX Experiment
Authors:
Tegan Beattie,
Ahmed Foda,
Colleen Henschel,
S Katsaganis,
Shaun Krueger,
George Lolos,
Zisis Papandreou,
E. L. Plummer,
Irina Semenova,
Andrei Semenov,
Fernando Barbosa,
Eugene Chudakov,
Mark Dalton,
David Lawrence,
Yi Qiang,
Nicholas Sandoval,
Elton Smith,
Christopher Stanislav,
Justin Stevens,
Simon Taylor,
Timothy Whitlatch,
Benedikt Zihlmann,
William Levine,
William McGinley,
Curtis Meyer
, et al. (14 additional authors not shown)
Abstract:
The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described herein. The calorimeter records the time and energy d…
▽ More
The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described herein. The calorimeter records the time and energy deposited by charged and neutral particles created by a multi-GeV photon beam. It is constructed as a lead and scintillating-fiber calorimeter and read out with 3840 large-area silicon photomultiplier arrays. Particles impinge on the detector over a wide range of angles, from normal incidence at 90 degrees down to 11.5 degrees, which defines a geometry that is fairly unique among calorimeters. The response of the calorimeter has been measured during a running experiment and performs as expected for electromagnetic showers below 2.5 GeV. We characterize the performance of the BCAL using the energy resolution integrated over typical angular distributions for $π^0$ and $η$ production of $σ_E/E$=5.2\%/$\sqrt{E(\rm{GeV})} \oplus$ 3.6\% and a timing resolution of $σ$\,=\,150\,ps at 1\,GeV.
△ Less
Submitted 20 April, 2018; v1 submitted 9 January, 2018;
originally announced January 2018.
-
Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab: an update on PR12-16-001
Authors:
M. Battaglieri,
A. Bersani,
G. Bracco,
B. Caiffi,
A. Celentano,
R. De Vita,
L. Marsicano,
P. Musico,
M. Osipenko,
F. Panza,
M. Ripani,
E. Santopinto,
M. Taiuti,
V. Bellini,
M. Bondi',
P. Castorina,
M. De Napoli,
A. Italiano,
V. Kuznetzov,
E. Leonora,
F. Mammoliti,
N. Randazzo,
L. Re,
G. Russo,
M. Russo
, et al. (101 additional authors not shown)
Abstract:
This document is an update to the proposal PR12-16-001 Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab submitted to JLab-PAC44 in 2016 reporting progress in addressing questions raised regarding the beam-on backgrounds. The concerns are addressed by adopting a new simulation tool, FLUKA, and planning measurements of muon fluxes from the dump with its existing shielding around t…
▽ More
This document is an update to the proposal PR12-16-001 Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab submitted to JLab-PAC44 in 2016 reporting progress in addressing questions raised regarding the beam-on backgrounds. The concerns are addressed by adopting a new simulation tool, FLUKA, and planning measurements of muon fluxes from the dump with its existing shielding around the dump. First, we have implemented the detailed BDX experimental geometry into a FLUKA simulation, in consultation with experts from the JLab Radiation Control Group. The FLUKA simulation has been compared directly to our GEANT4 simulations and shown to agree in regions of validity. The FLUKA interaction package, with a tuned set of biasing weights, is naturally able to generate reliable particle distributions with very small probabilities and therefore predict rates at the detector location beyond the planned shielding around the beam dump. Second, we have developed a plan to conduct measurements of the muon ux from the Hall-A dump in its current configuration to validate our simulations.
△ Less
Submitted 8 January, 2018; v1 submitted 5 December, 2017;
originally announced December 2017.
-
A novel comparison of Møller and Compton electron-beam polarimeters
Authors:
J. A. Magee,
A. Narayan,
D. Jones,
R. Beminiwattha,
J. C. Cornejo,
M. M. Dalton,
W. Deconinck,
D. Dutta,
D. Gaskell,
J. W. Martin,
K. D. Paschke,
V. Tvaskis,
A. Asaturyan,
J. Benesch,
G. Cates,
B. S. Cavness,
L. A. Dillon-Townes,
G. Hays,
J. Hoskins,
E. Ihloff,
R. Jones,
P. M. King,
S. Kowalski,
L. Kurchaninov,
L. Lee
, et al. (16 additional authors not shown)
Abstract:
We have performed a novel comparison between electron-beam polarimeters based on Møller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents ($<$ 5 $μ$A) during the $Q_{\rm weak}$ experiment in Hall C at Jefferson Lab. These low current measurements were bracketed by the regular high current (180 $μ$A) operation of the Compton polarimete…
▽ More
We have performed a novel comparison between electron-beam polarimeters based on Møller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents ($<$ 5 $μ$A) during the $Q_{\rm weak}$ experiment in Hall C at Jefferson Lab. These low current measurements were bracketed by the regular high current (180 $μ$A) operation of the Compton polarimeter. All measurements were found to be consistent within experimental uncertainties of 1% or less, demonstrating that electron polarization does not depend significantly on the beam current. This result lends confidence to the common practice of applying Møller measurements made at low beam currents to physics experiments performed at higher beam currents. The agreement between two polarimetry techniques based on independent physical processes sets an important benchmark for future precision asymmetry measurements that require sub-1% precision in polarimetry.
△ Less
Submitted 25 January, 2017; v1 submitted 19 October, 2016;
originally announced October 2016.
-
Atmospheric constituents and surface-level UVB: implications for a paleoaltimetry proxy and attempts to reconstruct UV exposure during volcanic episodes
Authors:
Brian C. Thomas,
Byron D. Goracke,
Sean M. Dalton
Abstract:
Chemical and morphological features of spores and pollens have been linked to changes in solar ultraviolet radiation (specifically UVB, 280-315 nm) at Earth's surface. Variation in UVB exposure as inferred from these features has been suggested as a proxy for paleoaltitude. While UVB irradiance does increase with altitude above sea level, a number of other factors affect the irradiance at any give…
▽ More
Chemical and morphological features of spores and pollens have been linked to changes in solar ultraviolet radiation (specifically UVB, 280-315 nm) at Earth's surface. Variation in UVB exposure as inferred from these features has been suggested as a proxy for paleoaltitude. While UVB irradiance does increase with altitude above sea level, a number of other factors affect the irradiance at any given place and time. In this modeling study we use the TUV atmospheric radiative transfer model to investigate dependence of surface-level UVB irradiance and relative biological impact on a number of constituents in Earth's atmosphere that are variable over long and short time periods. We consider changes in O3 column density, and SO2 and sulfate aerosols due to periods of volcanic activity, including that associated with the formation of the Siberian Traps. We find that UVB irradiance may be highly variable under volcanic conditions and variations in several of these atmospheric constituents can easily mimic or overwhelm changes in UVB irradiance due to changes in altitude. On the other hand, we find that relative change with altitude is not very sensitive to different sets of atmospheric conditions. Any paleoaltitude proxy based on UVB exposure requires confidence that the samples under comparison were located at roughly the same latitude, under very similar O3 and SO2 columns, with similar atmospheric aerosol conditions. In general, accurate estimates of the surface-level UVB exposure at any time and location require detailed radiative transfer modeling taking into account a number of atmospheric factors; this result is important for paleoaltitude proxies as well as attempts to reconstruct the UV environment through geologic time and to tie extinctions, such as the end-Permian mass extinction, to UVB irradiance changes.
△ Less
Submitted 26 August, 2016;
originally announced August 2016.
-
A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab
Authors:
A. Rakhman,
M. Hafez,
S. Nanda,
F. Benmokhtar,
A. Camsonne,
G. D. Cates,
M. M. Dalton,
G. B. Franklin,
M. Friend,
R. W. Michaels,
V. Nelyubin,
D. S. Parno,
K. D. Paschke,
B. P. Quinn,
P. A. Souder,
W. A. Tobias
Abstract:
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maxi…
▽ More
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maximum achieved green power at 5 W IR pump power is 1.74 W with a total conversion efficiency of 34.8\%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7~kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7\%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0\% precision in polarization measurements of an electron beam with energy and current of 1.0~GeV and 50~$μ$A.
△ Less
Submitted 29 March, 2016; v1 submitted 3 January, 2016;
originally announced January 2016.
-
First Results from The GlueX Experiment
Authors:
The GlueX Collaboration,
H. Al Ghoul,
E. G. Anassontzis,
F. Barbosa,
A. Barnes,
T. D. Beattie,
D. W. Bennett,
V. V. Berdnikov,
T. Black,
W. Boeglin,
W. K. Brooks,
B. Cannon,
O. Chernyshov,
E. Chudakov,
V. Crede,
M. M. Dalton,
A. Deur,
S. Dobbs,
A. Dolgolenko,
M. Dugger,
H. Egiyan,
P. Eugenio,
A. M. Foda,
J. Frye,
S. Furletov
, et al. (86 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of $π^{0}$, $η$ and…
▽ More
The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of $π^{0}$, $η$ and $ω$ mesons. Linearly-polarized photons were successfully produced through coherent bremsstrahlung and polarization transfer to the $ρ$ has been observed.
△ Less
Submitted 14 January, 2016; v1 submitted 11 December, 2015;
originally announced December 2015.
-
Hall A Annual Report 2014
Authors:
M. M. Dalton,
E. Chudakov,
J. Gomez,
D. W. Higinbotham,
C. Keppel,
R. Michaels,
L. Myers,
K. Aniol,
S. Iqbal,
N. See,
J. R. Arrington,
M. V. Ivanov,
M. Mihovilovič,
S. Širca,
N. Muangma,
Dien Nguyen,
R. Pomatsalyuk,
O. Glamazdin,
V. Vereshchaka,
S. Riordan,
T. Su,
V. Sulkosky,
P. Zhu
Abstract:
Report of the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility during 2013.
Report of the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility during 2013.
△ Less
Submitted 20 November, 2015;
originally announced November 2015.
-
Precision Electron-Beam Polarimetry using Compton Scattering at 1 GeV
Authors:
A. Narayan,
D. Jones,
J. C. Cornejo,
M. M. Dalton,
W. Deconinck,
D. Dutta,
D. Gaskell,
J. W. Martin,
K. D. Paschke,
V. Tvaskis,
A. Asaturyan,
J. Benesch,
G. Cates,
B. S. Cavness,
L. A. Dillon-Townes,
G. Hays,
E. Ihloff,
R. Jones,
S. Kowalski,
L. Kurchaninov,
L. Lee,
A. McCreary,
M. McDonald,
A. Micherdzinska,
A. Mkrtchyan
, et al. (11 additional authors not shown)
Abstract:
We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond micr…
▽ More
We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond micro-strip detector which was able to capture most of the spectrum of scattered electrons. The data analysis technique exploited track finding, the high granularity of the detector and its large acceptance. The polarization of the $180~μ$A, $1.16$~GeV electron beam was measured with a statistical precision of $<$~1\% per hour and a systematic uncertainty of 0.59\%. This exceeds the level of precision required by the \qweak experiment, a measurement of the vector weak charge of the proton. Proposed future low-energy experiments require polarization uncertainty $<$~0.4\%, and this result represents an important demonstration of that possibility. This measurement is also the first use of diamond detectors for particle tracking in an experiment.
△ Less
Submitted 17 February, 2016; v1 submitted 22 September, 2015;
originally announced September 2015.
-
The Q_weak Experimental Apparatus
Authors:
Qweak Collaboration,
T. Allison,
M. Anderson,
D. Androic,
D. S. Armstrong,
A. Asaturyan,
T. D. Averett,
R. Averill,
J. Balewski,
J. Beaufait,
R. S. Beminiwattha,
J. Benesch,
F. Benmokhtar,
J. Bessuille,
J. Birchall,
E. Bonnell,
J. Bowman,
P. Brindza,
D. B. Brown,
R. D. Carlini,
G. D. Cates,
B. Cavness,
G. Clark,
J. C. Cornejo,
S. Covrig Dusa
, et al. (104 additional authors not shown)
Abstract:
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry…
▽ More
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 microA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Moller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8 degrees and 11.6 degrees were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cerenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q^2 = 0.025 GeV^2 was determined using dedicated low-current (~100 pA) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet.
△ Less
Submitted 6 January, 2015; v1 submitted 24 September, 2014;
originally announced September 2014.
-
A study of decays to strange final states with GlueX in Hall D using components of the BaBar DIRC
Authors:
The GlueX Collaboration,
M. Dugger,
B. Ritchie,
I. Senderovich,
E. Anassontzis,
P. Ioannou,
C. Kourkoumeli,
G. Vasileiadis,
G. Voulgaris,
N. Jarvis,
W. Levine,
P. Mattione,
W. McGinley,
C. A. Meyer,
R. Schumacher,
M. Staib,
F. Klein,
D. Sober,
N. Sparks,
N. Walford,
D. Doughty,
A. Barnes,
R. Jones,
J. McIntyre,
F. Mokaya
, et al. (82 additional authors not shown)
Abstract:
We propose to enhance the kaon identification capabilities of the GlueX detector by constructing an FDIRC (Focusing Detection of Internally Reflected Cherenkov) detector utilizing the decommissioned BaBar DIRC components. The GlueX FDIRC would significantly enhance the GlueX physics program by allowing one to search for and study hybrid mesons decaying into kaon final states. Such systematic studi…
▽ More
We propose to enhance the kaon identification capabilities of the GlueX detector by constructing an FDIRC (Focusing Detection of Internally Reflected Cherenkov) detector utilizing the decommissioned BaBar DIRC components. The GlueX FDIRC would significantly enhance the GlueX physics program by allowing one to search for and study hybrid mesons decaying into kaon final states. Such systematic studies of kaon final states are essential for inferring the quark flavor content of hybrid and conventional mesons. The GlueX FDIRC would reuse one-third of the synthetic fused silica bars that were utilized in the BaBar DIRC. A new focussing photon camera, read out with large area photodetectors, would be developed. We propose operating the enhanced GlueX detector in Hall D for a total of 220 days at an average intensity of 5x10^7 γ/s, a program that was conditionally approved by PAC39
△ Less
Submitted 1 August, 2014;
originally announced August 2014.
-
Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab
Authors:
BDX Collaboration,
M. Battaglieri,
A. Celentano,
R. De Vita,
E. Izaguirre,
G. Krnjaic,
E. Smith,
S. Stepanyan,
A. Bersani,
E. Fanchini,
S. Fegan,
P. Musico,
M. Osipenko,
M. Ripani,
E. Santopinto,
M. Taiuti,
P. Schuster,
N. Toro,
M. Dalton,
A. Freyberger,
F. -X. Girod,
V. Kubarovsky,
M. Ungaro,
G. De Cataldo,
R. De Leo
, et al. (61 additional authors not shown)
Abstract:
MeV-GeV dark matter (DM) is theoretically well motivated but remarkably unexplored. This Letter of Intent presents the MeV-GeV DM discovery potential for a 1 m$^3$ segmented plastic scintillator detector placed downstream of the beam-dump at one of the high intensity JLab experimental Halls, receiving up to 10$^{22}$ electrons-on-target (EOT) in a one-year period. This experiment (Beam-Dump eXperi…
▽ More
MeV-GeV dark matter (DM) is theoretically well motivated but remarkably unexplored. This Letter of Intent presents the MeV-GeV DM discovery potential for a 1 m$^3$ segmented plastic scintillator detector placed downstream of the beam-dump at one of the high intensity JLab experimental Halls, receiving up to 10$^{22}$ electrons-on-target (EOT) in a one-year period. This experiment (Beam-Dump eXperiment or BDX) is sensitive to DM-nucleon elastic scattering at the level of a thousand counts per year, with very low threshold recoil energies ($\sim$1 MeV), and limited only by reducible cosmogenic backgrounds. Sensitivity to DM-electron elastic scattering and/or inelastic DM would be below 10 counts per year after requiring all electromagnetic showers in the detector to exceed a few-hundred MeV, which dramatically reduces or altogether eliminates all backgrounds. Detailed Monte Carlo simulations are in progress to finalize the detector design and experimental set up. An existing 0.036 m$^3$ prototype based on the same technology will be used to validate simulations with background rate estimates, driving the necessary R$\&$D towards an optimized detector. The final detector design and experimental set up will be presented in a full proposal to be submitted to the next JLab PAC. A fully realized experiment would be sensitive to large regions of DM parameter space, exceeding the discovery potential of existing and planned experiments by two orders of magnitude in the MeV-GeV DM mass range.
△ Less
Submitted 11 June, 2014;
originally announced June 2014.
-
Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab
Authors:
M. Friend,
D. Parno,
F. Benmokhtar,
A. Camsonne,
M. Dalton,
G. B. Franklin,
V. Mamyan,
R. Michaels,
S. Nanda,
V. Nelyubin,
K. Paschke,
B. Quinn,
A. Rakhman,
P. Souder,
A. Tobias
Abstract:
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crysta…
▽ More
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.
△ Less
Submitted 24 August, 2011; v1 submitted 15 August, 2011;
originally announced August 2011.