-
New beyond-Voigt line-shape profile recommended for the HITRAN database
Authors:
P. Wcisło,
N. Stolarczyk,
M. Słowiński,
H. Jóźwiak,
D. Lisak,
R. Ciuryło,
A. Cygan,
F. Schreier,
C. D. Boone,
A. Castrillo,
L. Gianfrani,
Y. Tan,
S-M. Hu,
E. Adkins,
J. T. Hodges,
H. Tran,
H. N. Ngo,
J. -M. Hartmann,
S. Beguier,
A. Campargue,
R. J. Hargreaves,
L. S. Rothman,
I. E. Gordon
Abstract:
Parameters associated with the collisional perturbation of spectral lines are essential for modeling the absorption of electromagnetic radiation in gas media. The HITRAN molecular spectroscopic database provides these parameters, although originally they were associated only with the Voigt profile parameterization. However, in the HITRAN2016 and HITRAN2020 editions, Voigt, speed-dependent Voigt an…
▽ More
Parameters associated with the collisional perturbation of spectral lines are essential for modeling the absorption of electromagnetic radiation in gas media. The HITRAN molecular spectroscopic database provides these parameters, although originally they were associated only with the Voigt profile parameterization. However, in the HITRAN2016 and HITRAN2020 editions, Voigt, speed-dependent Voigt and Hartmann-Tran (HT) profiles have been incorporated, thanks to the new relational structure of the database. The HT profile was introduced in HITRAN in 2016 as a recommended profile for the most accurate spectral interpretations and modeling. It was parameterized with a four-temperature-range temperature dependence. Since then, however, some features of the HT profile have been revealed that are problematic from a practical perspective. These are: the singular behavior of the temperature dependencies of the velocity-changing parameters when the shift parameter crosses zero and the difficulty in evaluating the former for mixtures. In this article, we summarize efforts to eliminate the above-mentioned problems that led us to recommend using the quadratic speed-dependent hard-collision (qSDHC) profile with double-power-law (DPL) temperature dependencies. We refer to this profile as a modified Hartmann-Tran (mHT) profile. The computational cost of evaluating it is the same as for the HT profile. We give a detailed description of the mHT profile (also including line mixing) and discuss the representation of its parameters, together with their DPL temperature parametrization adopted in the HITRAN database. We discuss an efficient algorithm for evaluating this profile and provide corresponding computer codes in several programming languages: Fortran, Python, MATLAB, Wolfram Mathematica, and LabVIEW. We also discuss the associated update of the HITRAN Application Programming Interface (HAPI).
△ Less
Submitted 27 March, 2025;
originally announced March 2025.
-
Leveraging resonant frequencies of an optical cavity for spectroscopic measurement of gas temperature and concentration
Authors:
Daniel Lisak,
Vittorio D'Agostino,
Szymon Wójtewicz,
Agata Cygan,
Marcin Gibas,
Piotr Wcisło,
Roman Ciuryło,
Katarzyna Bielska
Abstract:
We introduce a spectroscopic approach to primary gas thermometry, harnessing precise optical cavity resonance frequencies and ab initio molecular line intensity calculations. By utilizing CO (3-0) vibrational band lines and cavity mode dispersion spectroscopy, we achieve an uncertainty of 82 ppm (24 mK at 296 K) in line-intensity-ratio thermometry (LRT) - over an order of magnitude lower than any…
▽ More
We introduce a spectroscopic approach to primary gas thermometry, harnessing precise optical cavity resonance frequencies and ab initio molecular line intensity calculations. By utilizing CO (3-0) vibrational band lines and cavity mode dispersion spectroscopy, we achieve an uncertainty of 82 ppm (24 mK at 296 K) in line-intensity-ratio thermometry (LRT) - over an order of magnitude lower than any previously reported spectroscopic thermometry at gas pressures above 1.2 kPa. This method extends high-precision spectroscopic thermometry across a pressure range an order of magnitude larger than prior techniques, enabling a fully optical, non-contact, and molecule-selective primary amount-of-substance measurement. We further demonstrate sub-permille uncertainty in gas concentration measurements across pressures from 50 Pa to 20 kPa, significantly enhancing the precision and versatility of spectroscopic gas metrology.
△ Less
Submitted 24 February, 2025;
originally announced February 2025.
-
Cavity-enhanced spectroscopy in the deep cryogenic regime -- new hydrogen technologies for quantum sensing
Authors:
Kamil Stankiewicz,
Marcin Makowski,
Michał Słowiński,
Kamil L. Sołtys,
Bogdan Bednarski,
Hubert Jóźwiak,
Nikodem Stolarczyk,
Mateusz Narożnik,
Dariusz Kierski,
Szymon Wójtewicz,
Agata Cygan,
Grzegorz Kowzan,
Piotrz Masłowski,
Mariusz Piwiński,
Daniel Lisak,
Piotr Wcisło
Abstract:
Spectrometers based on high-finesse optical cavities have proven to be powerful tools for applied and fundamental studies. Extending this technology to the deep cryogenic regime is beneficial in many ways: Doppler broadening is reduced, peak absorption is enhanced, the Boltzmann distribution of rotational states is narrowed, all unwanted molecular species disturbing the spectra are frozen out, and…
▽ More
Spectrometers based on high-finesse optical cavities have proven to be powerful tools for applied and fundamental studies. Extending this technology to the deep cryogenic regime is beneficial in many ways: Doppler broadening is reduced, peak absorption is enhanced, the Boltzmann distribution of rotational states is narrowed, all unwanted molecular species disturbing the spectra are frozen out, and dense spectra of complex polyatomic molecules become easier to assign. We demonstrate a cavity-enhanced spectrometer fully operating in the deep cryogenic regime down to 4 K. We solved several technological challenges that allowed us to uniformly cool not only the sample but also the entire cavity, including the mirrors and cavity length actuator, which ensures the thermodynamic equilibrium of a gas sample. Our technology well isolates the cavity from external noise and cryocooler vibrations. This instrument enables a variety of fundamental and practical applications. We demonstrate a few examples based on accurate spectroscopy of cryogenic hydrogen molecules: accurate test of the quantum electrodynamics for molecules; realization of the primary SI standards for temperature, concentration and pressure in the deep cryogenic regime; measurement of the H$_{2}$ phase diagram; and determination of the ortho-para spin isomer conversion rate.
△ Less
Submitted 18 February, 2025;
originally announced February 2025.
-
Heterodyne dispersive cavity ring-down spectroscopy exploiting eigenmode frequencies for high-fidelity measurements
Authors:
Agata Cygan,
Szymon Wójtewicz,
Hubert Jóźwiak,
Grzegorz Kowzan,
Nikodem Stolarczyk,
Katarzyna Bielska,
Piotr Wcisło,
Roman Ciuryło,
Daniel Lisak
Abstract:
Measuring low light absorption with combined uncertainty < 1 permille is crucial in a wide range of applications. Popular cavity ring-down spectroscopy can provide ultra-high precision, below 0.01 permille, but its accuracy is strongly dependent on the measurement capabilities of the detection system and typically is about 10 permille. Here, we exploit the optical frequency information carried by…
▽ More
Measuring low light absorption with combined uncertainty < 1 permille is crucial in a wide range of applications. Popular cavity ring-down spectroscopy can provide ultra-high precision, below 0.01 permille, but its accuracy is strongly dependent on the measurement capabilities of the detection system and typically is about 10 permille. Here, we exploit the optical frequency information carried by the ring-down cavity electromagnetic field, not explored in conventional CRDS, for high-fidelity spectroscopy. Instead of measuring only the decaying light intensity, we perform heterodyne detection of ring-downs followed by Fourier analysis to provide exact frequencies of optical cavity modes and a dispersive spectrum of a gas sample from them. This approach is insensitive to inaccuracies in light intensity measurements and eliminates the problem of detector band nonlinearity, the main cause of measurement error in traditional CRDS. Using the CO and HD line intensities as examples, we demonstrate the sub-permille accuracy of our method, confirmed by the best ab initio results, and the long-term repeatability of our dispersion measurements at 10^(-4) level. Such results have not been achieved in optical spectroscopy before. The high accuracy of the presented method indicates its potential in atmospheric studies, isotope ratio metrology, thermometry, and the establishment of primary gas standards.
△ Less
Submitted 4 March, 2024;
originally announced March 2024.
-
Sub-promille measurements and calculations of CO (3--0) overtone line intensities
Authors:
K. Bielska,
A. A. Kyuberis,
Z. D. Reed,
Gang Li,
A. Cygan,
R. Ciuryło,
D. Lisak,
E. M. Adkins,
L. Lodi,
J. T. Hodges,
V. Ebert,
N. F. Zobov,
J. Tennyson,
O. L. Polyansky
Abstract:
Intensities of lines in the near-infrared second overtone band (3--0) of $^{12}$C$^{16}$O are measured and calculated to an unprecedented degree of precision and accuracy. Agreement between theory and experiment to better than 1 $\permil$ is demonstrated by results from two laboratories involving two independent absorption- and dispersion-based cavity-enhanced techniques. Similarly, independent Fo…
▽ More
Intensities of lines in the near-infrared second overtone band (3--0) of $^{12}$C$^{16}$O are measured and calculated to an unprecedented degree of precision and accuracy. Agreement between theory and experiment to better than 1 $\permil$ is demonstrated by results from two laboratories involving two independent absorption- and dispersion-based cavity-enhanced techniques. Similarly, independent Fourier transform spectroscopy measurements of stronger lines in this band yield mutual agreement and consistency with theory at the 1 $\permil$ level. This set of highly accurate intensities can provide an intrinsic reference for reducing biases in future measurements of spectroscopic peak areas.
△ Less
Submitted 27 July, 2022;
originally announced July 2022.
-
Dual-comb cavity ring-down spectroscopy
Authors:
D. Lisak,
D. Charczun,
A. Nishiyama,
T. Voumard,
T. Wildi,
G. Kowzan,
V. Brasch,
T. Herr,
A. J. Fleisher,
J. T. Hodges,
R. Ciuryło,
A. Cygan,
P. Masłowski
Abstract:
Cavity ring-down spectroscopy is a ubiquitous optical method used to study light-matter interactions with high resolution, sensitivity and accuracy. However, it has never been performed with the multiplexing advantages of direct frequency comb spectroscopy without sacrificing orders of magnitude of resolution. We present dual-comb cavity ring-down spectroscopy (DC-CRDS) based on the parallel heter…
▽ More
Cavity ring-down spectroscopy is a ubiquitous optical method used to study light-matter interactions with high resolution, sensitivity and accuracy. However, it has never been performed with the multiplexing advantages of direct frequency comb spectroscopy without sacrificing orders of magnitude of resolution. We present dual-comb cavity ring-down spectroscopy (DC-CRDS) based on the parallel heterodyne detection of ring-down signals with a local oscillator comb to yield absorption and dispersion spectra. These spectra are obtained from widths and positions of cavity modes. We present two approaches which leverage the dynamic cavity response to coherently or randomly driven changes in the amplitude or frequency of the probe field. Both techniques yield accurate spectra of methane - an important greenhouse gas and breath biomarker. The high sensitivity and accuracy of broadband DC-CRDS, shows promise for applications like studies of the structure and dynamics of large molecules, multispecies trace gas detection and isotopic composition.
△ Less
Submitted 14 June, 2021;
originally announced June 2021.
-
Ultra-high finesse cavity-enhanced spectroscopy for accurate tests of quantum electrodynamics for molecules
Authors:
M. Zaborowski,
M. Słowiński,
K. Stankiewicz,
F. Thibault,
A. Cygan,
H. Jóźwiak,
G. Kowzan,
P. Masłowski,
A. Nishiyama,
N. Stolarczyk,
S. Wójtewicz,
R. Ciuryło,
D. Lisak,
P. Wcisło
Abstract:
We report the most accurate measurement of the position of the weak quadrupole S(2) 2-0 line in D$_2$. The spectra were collected with a frequency-stabilized cavity ring-down spectrometer (FS-CRDS) with an ultra-high finesse optical cavity ($\mathcal{F}$ = 637 000) and operating in the frequency-agile, rapid scanning spectroscopy (FARS) mode. Despite working in the Doppler-limited regime, we reach…
▽ More
We report the most accurate measurement of the position of the weak quadrupole S(2) 2-0 line in D$_2$. The spectra were collected with a frequency-stabilized cavity ring-down spectrometer (FS-CRDS) with an ultra-high finesse optical cavity ($\mathcal{F}$ = 637 000) and operating in the frequency-agile, rapid scanning spectroscopy (FARS) mode. Despite working in the Doppler-limited regime, we reached 40 kHz of statistical uncertainty and 161 kHz of absolute accuracy, achieving the highest accuracy for homonuclear isotopologues of molecular hydrogen. The accuracy of our measurement corresponds to the fifth significant digit of the leading term in QED correction. We observe 2.3$σ$ discrepancy with the recent theoretical value.
△ Less
Submitted 27 January, 2020;
originally announced January 2020.
-
Cavity buildup dispersion spectroscopy
Authors:
A. Cygan,
A. J. Fleisher,
R. Ciuryło,
K. A. Gillis,
J. T. Hodges,
D. Lisak
Abstract:
Measurements of ultrahigh-fidelity absorption spectra can help validate quantum theory, engineer ultracold chemistry, and remotely sense atmospheres. Recent achievements in cavity-enhanced spectroscopy using either frequency-based dispersion or time-based absorption approaches have set new records for accuracy with uncertainties at the sub-per-mil level. However, laser scanning5 or susceptibility…
▽ More
Measurements of ultrahigh-fidelity absorption spectra can help validate quantum theory, engineer ultracold chemistry, and remotely sense atmospheres. Recent achievements in cavity-enhanced spectroscopy using either frequency-based dispersion or time-based absorption approaches have set new records for accuracy with uncertainties at the sub-per-mil level. However, laser scanning5 or susceptibility to nonlinearities limits their ultimate performance. Here we present cavity buildup dispersion spectroscopy (CBDS) in which the dispersive frequency shift of a cavity resonance is encoded in the cavity's transient response to a phase-locked non-resonant laser excitation. Beating between optical frequencies during buildup exactly localizes detuning from mode center, and thus enables single-shot dispersion measurements. CBDS yields an accuracy limited by the chosen frequency standard, a speed limited by the cavity round-trip time, and is currently 50 times less susceptible to detection nonlinearity compared to intensity-based methods. The universality of CBDS shows promise for improving fundamental research into a variety of light-matter interactions.
△ Less
Submitted 23 January, 2020;
originally announced January 2020.
-
Absolute frequency determination of molecular transition in the Doppler regime at kHz level of accuracy
Authors:
K. Bielska,
S. Wojtewicz,
P. Morzynski,
P. Ablewski,
A. Cygan,
M. Bober,
M. Zawada,
R. Ciurylo,
P. Maslowski,
D. Lisak
Abstract:
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an…
▽ More
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an $^{88}$Sr optical atomic clock by an optical frequency comb.
△ Less
Submitted 16 August, 2017; v1 submitted 18 May, 2017;
originally announced May 2017.
-
Fibre-optic delivery of time and frequency to VLBI station
Authors:
P. Krehlik,
Ł. Buczek,
J. Kołodziej,
M. Lipiński,
Ł. Śliwczyński,
J. Nawrocki,
P. Nogaś,
A. Marecki,
E. Pazderski,
P. Ablewski,
M. Bober,
R. Ciuryło,
A. Cygan,
D. Lisak,
P. Masłowski,
P. Morzyński,
M. Zawada,
R. M. Campbell,
J. Pieczerak,
A. Binczewski,
K. Turza
Abstract:
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabi…
▽ More
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabilized, long-distance fibre-optic link. The T&F reference signals, traceable to international atomic timescale (TAI), are delivered to the VLBI station from a dedicated timekeeping laboratory. Moreover, we describe a proof-of-concept experiment where the VLBI station is synchronized to a remote strontium optical lattice clock during the observation.
△ Less
Submitted 7 July, 2017; v1 submitted 28 March, 2017;
originally announced March 2017.
-
Searching for topological defect dark matter with optical atomic clocks
Authors:
Piotr Wcislo,
Piotr Morzynski,
Marcin Bober,
Agata Cygan,
Daniel Lisak,
Roman Ciurylo,
Michal Zawada
Abstract:
The total mass density of the Universe appears to be dominated by dark matter. However, beyond its gravitational interactions at the galactic scale, little is known about its nature. Extensions of the quantum electrodynamics Lagrangian with dark-matter coupling terms may result in changes to Standard Model parameters. Recently, it was proposed that a network of atomic clocks could be used to searc…
▽ More
The total mass density of the Universe appears to be dominated by dark matter. However, beyond its gravitational interactions at the galactic scale, little is known about its nature. Extensions of the quantum electrodynamics Lagrangian with dark-matter coupling terms may result in changes to Standard Model parameters. Recently, it was proposed that a network of atomic clocks could be used to search for transient signals of a hypothetical dark matter in the form of stable topological defects. The clocks become desynchronized when a dark-matter object sweeps through the network. This pioneering approach, which is applicable only for distant clocks, is limited by the quality of the fibre links. Here, we present an alternative experimental approach that is applicable to both closely spaced and distant optical atomic clocks and benefits from their individual susceptibilities to dark matter, hence not requiring fibre links. We explore a new dimension of astrophysical observations by constraining the strength of atomic coupling to the hypothetical dark-matter cosmic objects. Our experimental constraint exceeds the previous limits; in fact, it not only reaches the ultimate level expected to be achievable with a constellation of GPS atomic clocks but also has a large potential for improvement.
△ Less
Submitted 2 September, 2016; v1 submitted 18 May, 2016;
originally announced May 2016.
-
Absolute measurement of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ clock transition in neutral ${}^{88}$Sr over the 330 km-long stabilized fibre optic link
Authors:
Piotr Morzynski,
Marcin Bober,
Dobroslawa Bartoszek-Bober,
Jerzy Nawrocki,
Przemyslaw Krehlik,
Lukasz Sliwczynski,
Marcin Lipinski,
Piotr Maslowski,
Agata Cygan,
Piotr Dunst,
Michal Garus,
Daniel Lisak,
Jerzy Zachorowski,
Wojciech Gawlik,
Czeslaw Radzewicz,
Roman Ciurylo,
Michal Zawada
Abstract:
We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fi…
▽ More
We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fibre optical link. The result was verified by series of measurements on two independent optical lattice clocks and agrees with recommendation of Bureau International des Poids et Mesures.
△ Less
Submitted 7 December, 2015;
originally announced December 2015.
-
Strontium optical lattice clocks for practical realization of the metre and secondary representation of the second
Authors:
M. Bober,
P. Morzyński,
A. Cygan,
D. Lisak,
P. Masłowski,
M. Prymaczek,
P. Wcisło,
P. Ablewski,
M. Piwiński,
S. Wójtewicz,
K. Bielska,
D. Bartoszek-Bober,
R. Trawiński,
M. Zawada,
R. Ciuryło,
J. Zachorowski,
M. Piotrowski,
W. Gawlik,
F. Ozimek,
C. Radzewicz
Abstract:
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice…
▽ More
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice clocks.
△ Less
Submitted 15 June, 2015;
originally announced June 2015.