-
Shape matters: Understanding the effect of electrode geometry on cell resistance and chemo-mechanical stress
Authors:
Tiras Y. Lin,
Hanyu Li,
Nicholas W. Brady,
Nicholas R. Cross,
Victoria M. Ehlinger,
Thomas Roy,
Daniel Tortorelli,
Christine Orme,
Marcus A. Worsley,
Giovanna Bucci
Abstract:
Rechargeable batteries that incorporate shaped three-dimensional electrodes have been shown to have increased power and energy densities for a given footprint area when compared to a conventional geometry, i.e., a planar cathode and anode that sandwich an electrolyte. Electrodes can be shaped to enable a higher loading of active material, while keeping the ion transport distance small, however, th…
▽ More
Rechargeable batteries that incorporate shaped three-dimensional electrodes have been shown to have increased power and energy densities for a given footprint area when compared to a conventional geometry, i.e., a planar cathode and anode that sandwich an electrolyte. Electrodes can be shaped to enable a higher loading of active material, while keeping the ion transport distance small, however, the relationship between electrical and mechanical performance remains poorly understood. A variety of electrode shapes have been explored, where the electrodes are individually shaped or intertwined with one another. Advances in manufacturing and shape and topology optimization have made such designs a reality. In this paper, we explore sinusoidal half cells and interdigitated full cells. First, we use a simple electrostatics model to understand the cell resistance as a function of shape. We focus on low-temperature conditions, where the electrolyte conductivity decreases and the governing dimensionless parameters change. Next, we use a chemo-mechanics model to examine the stress concentrations that arise due to intercalation-driven volume expansion. We show that shaped electrodes provide a significant reduction in resistance, however, they result in unfavorable stress concentrations. Overall, we find that the fully interdigitated electrodes may provide the best balance with respect to this trade-off.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Euclid preparation. LIII. LensMC, weak lensing cosmic shear measurement with forward modelling and Markov Chain Monte Carlo sampling
Authors:
Euclid Collaboration,
G. Congedo,
L. Miller,
A. N. Taylor,
N. Cross,
C. A. J. Duncan,
T. Kitching,
N. Martinet,
S. Matthew,
T. Schrabback,
M. Tewes,
N. Welikala,
N. Aghanim,
A. Amara,
S. Andreon,
N. Auricchio,
M. Baldi,
S. Bardelli,
R. Bender,
C. Bodendorf,
D. Bonino,
E. Branchini,
M. Brescia,
J. Brinchmann,
S. Camera
, et al. (217 additional authors not shown)
Abstract:
LensMC is a weak lensing shear measurement method developed for Euclid and Stage-IV surveys. It is based on forward modelling in order to deal with convolution by a point spread function (PSF) with comparable size to many galaxies; sampling the posterior distribution of galaxy parameters via Markov Chain Monte Carlo; and marginalisation over nuisance parameters for each of the 1.5 billion galaxies…
▽ More
LensMC is a weak lensing shear measurement method developed for Euclid and Stage-IV surveys. It is based on forward modelling in order to deal with convolution by a point spread function (PSF) with comparable size to many galaxies; sampling the posterior distribution of galaxy parameters via Markov Chain Monte Carlo; and marginalisation over nuisance parameters for each of the 1.5 billion galaxies observed by Euclid. We quantified the scientific performance through high-fidelity images based on the Euclid Flagship simulations and emulation of the Euclid VIS images; realistic clustering with a mean surface number density of 250 arcmin$^{-2}$ ($I_{\rm E}<29.5$) for galaxies, and 6 arcmin$^{-2}$ ($I_{\rm E}<26$) for stars; and a diffraction-limited chromatic PSF with a full width at half maximum of $0.^{\!\prime\prime}2$ and spatial variation across the field of view. LensMC measured objects with a density of 90 arcmin$^{-2}$ ($I_{\rm E}<26.5$) in 4500 deg$^2$. The total shear bias was broken down into measurement (our main focus here) and selection effects (which will be addressed elsewhere). We found measurement multiplicative and additive biases of $m_1=(-3.6\pm0.2)\times10^{-3}$, $m_2=(-4.3\pm0.2)\times10^{-3}$, $c_1=(-1.78\pm0.03)\times10^{-4}$, $c_2=(0.09\pm0.03)\times10^{-4}$; a large detection bias with a multiplicative component of $1.2\times10^{-2}$ and an additive component of $-3\times10^{-4}$; and a measurement PSF leakage of $α_1=(-9\pm3)\times10^{-4}$ and $α_2=(2\pm3)\times10^{-4}$. When model bias is suppressed, the obtained measurement biases are close to Euclid requirement and largely dominated by undetected faint galaxies ($-5\times10^{-3}$). Although significant, model bias will be straightforward to calibrate given the weak sensitivity. LensMC is publicly available at https://gitlab.com/gcongedo/LensMC
△ Less
Submitted 2 December, 2024; v1 submitted 1 May, 2024;
originally announced May 2024.
-
Topology Optimization for the Full-Cell Design of Porous Electrodes in Electrochemical Energy Storage Devices
Authors:
Hanyu Li,
Giovanna Bucci,
Nicholas W. Brady,
Nicholas R. Cross,
Victoria M. Ehlinger,
Tiras Y. Lin,
Miguel Salazar de Troya,
Daniel Tortorelli,
Marcus A. Worsley,
Thomas Roy
Abstract:
In this paper, we introduce a density-based topology optimization framework to design porous electrodes for maximum energy storage. We simulate the full cell with a model that incorporates electronic potential, ionic potential, and electrolyte concentration. The system consists of three materials, namely pure liquid electrolyte and the porous solids of the anode and cathode, for which we determine…
▽ More
In this paper, we introduce a density-based topology optimization framework to design porous electrodes for maximum energy storage. We simulate the full cell with a model that incorporates electronic potential, ionic potential, and electrolyte concentration. The system consists of three materials, namely pure liquid electrolyte and the porous solids of the anode and cathode, for which we determine the optimal placement. We use separate electronic potentials to model each electrode, which allows interdigitated designs. As a result, a penalization is required to ensure that the anode and cathode do not touch, i.e., causing a short circuit. We compare multiple 2D designs generated for different fixed conditions, e.g. material properties. A 3D design with complex channel and interlocked structure is also created. All optimized designs are far superior to the traditional monolithic electrode design with respect to energy storage metrics. We observe up to a 750% increase in energy storage for cases with slow effective ionic diffusion within the porous electrode.
△ Less
Submitted 6 November, 2024; v1 submitted 26 March, 2024;
originally announced March 2024.
-
Assessing Lesion Segmentation Bias of Neural Networks on Motion Corrupted Brain MRI
Authors:
Tejas Sudharshan Mathai,
Yi Wang,
Nathan Cross
Abstract:
Patient motion during the magnetic resonance imaging (MRI) acquisition process results in motion artifacts, which limits the ability of radiologists to provide a quantitative assessment of a condition visualized. Often times, radiologists either "see through" the artifacts with reduced diagnostic confidence, or the MR scans are rejected and patients are asked to be recalled and re-scanned. Present…
▽ More
Patient motion during the magnetic resonance imaging (MRI) acquisition process results in motion artifacts, which limits the ability of radiologists to provide a quantitative assessment of a condition visualized. Often times, radiologists either "see through" the artifacts with reduced diagnostic confidence, or the MR scans are rejected and patients are asked to be recalled and re-scanned. Presently, there are many published approaches that focus on MRI artifact detection and correction. However, the key question of the bias exhibited by these algorithms on motion corrupted MRI images is still unanswered. In this paper, we seek to quantify the bias in terms of the impact that different levels of motion artifacts have on the performance of neural networks engaged in a lesion segmentation task. Additionally, we explore the effect of a different learning strategy, curriculum learning, on the segmentation performance. Our results suggest that a network trained using curriculum learning is effective at compensating for different levels of motion artifacts, and improved the segmentation performance by ~9%-15% (p < 0.05) when compared against a conventional shuffled learning strategy on the same motion data. Within each motion category, it either improved or maintained the dice score. To the best of our knowledge, we are the first to quantitatively assess the segmentation bias on various levels of motion artifacts present in a brain MRI image.
△ Less
Submitted 12 October, 2020;
originally announced October 2020.