-
Exploring the keV-scale physics potential of CUORE
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
A. Armatol,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
C. Capelli,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali
, et al. (98 additional authors not shown)
Abstract:
We present the analysis techniques developed to explore the keV-scale energy region of the CUORE experiment, based on more than 2 tonne yr of data collected over 5 years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among t…
▽ More
We present the analysis techniques developed to explore the keV-scale energy region of the CUORE experiment, based on more than 2 tonne yr of data collected over 5 years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data taking conditions. We achieve an average baseline resolution of 2.54 $\pm$ 0.14 keV FWHM and 1.18 $\pm$ 0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06 $\pm$ 0.05 counts/(keV kg days) and 16 $\pm$ 2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 26 $\pm$ 4 \% and 50 $\pm$ 2 \% at 3 keV and 10 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that tonne-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.
△ Less
Submitted 29 May, 2025;
originally announced May 2025.
-
First-ever detection of microseismic activity with a tonne-scale cryogenic experiment
Authors:
D. Q. Adams,
C. Alduino,
K. Alfonso,
A. Armatol,
F. T. Avignone,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
C. Capelli,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (105 additional authors not shown)
Abstract:
Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0νββ$) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here we report the first detection of marine microseismic vibrations us…
▽ More
Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0νββ$) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here we report the first detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for $0νββ$ decay with mK-scale calorimeters and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE's energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to $0νββ$ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.
△ Less
Submitted 13 May, 2025;
originally announced May 2025.
-
Depth profiling the elemental composition with negative muons: Monte Carlo based tools for improved data analysis
Authors:
M. Cataldo,
A. D Hillier,
O. Cremonesi,
F. Grazzi,
S. Porcinai,
M. Clemenza
Abstract:
Gildings, patinas and alteration crusts are common features of many heritage artefacts, especially for metals. Their size depends on many factors, like the manufacturing method for gildings or the conservation state for alteration crusts: in some cases, it can be in the scale of the tens of microns. Such thickness would be difficult to investigate with classical non-destructive methods and would p…
▽ More
Gildings, patinas and alteration crusts are common features of many heritage artefacts, especially for metals. Their size depends on many factors, like the manufacturing method for gildings or the conservation state for alteration crusts: in some cases, it can be in the scale of the tens of microns. Such thickness would be difficult to investigate with classical non-destructive methods and would prevent getting information from the bulk of the sample. This work proposes an innovative approach for the study of multi-layered materials with the Muonic atom X-ray Emission Spectroscopy technique (μ-XES). Based on the detection of the high-energy X-rays emitted after the muon capture by the atom, this method is characterised by a remarkable penetration depth (from microns to cm). From the surface to the bulk, this technique can evaluate the variation of the elemental composition as a function of depth. The paper focuses on providing an improved interpretation of μ-XES data by coupling the analysis with the use of two Monte Carlo simulation software, GEANT4/ARBY and SRIM/TRIM. With these two software, it is possible to replicate the negative muon experiments and compare the experimental and simulated outputs to address the size of a given layer. To validate this approach, a set of standard gilded bronze and brass foils were measured at the ISIS Neutron and Muon source. From simulations, it was possible to evaluate the thickness of the superficial gold layer, with results in agreement with the preliminary SEM characterisation of the samples.
△ Less
Submitted 7 May, 2025;
originally announced May 2025.
-
Innovating Bolometers' Mounting: A Gravity-Based Approach
Authors:
The CUPID Collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
L. Benussi,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
F. Boffelli,
V. Boldrini,
E. D. Brandani,
C. Brofferio,
C. Bucci,
M. Buchynska,
J. Camilleri
, et al. (168 additional authors not shown)
Abstract:
Cryogenic calorimeters, also known as bolometers, are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of $^{100}$Mo. The CUPID collaboration proposed an innovative approach to assembling bolometers in a stacked configuration, held in position solely by grav…
▽ More
Cryogenic calorimeters, also known as bolometers, are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of $^{100}$Mo. The CUPID collaboration proposed an innovative approach to assembling bolometers in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of bolometers and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li$_2$MoO$_4$ crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than $\pm$0.5 mK at 10 mK, (ii) a good energy resolution of Li$_2$MoO$_4$ bolometers, (6.6 $\pm$ 2.2) keV FWHM at 2615 keV, and (iii) a Li$_2$MoO$_4$ light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.
△ Less
Submitted 6 March, 2025;
originally announced March 2025.
-
CUPID, the CUORE Upgrade with Particle Identification
Authors:
The CUPID Collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
L. Benussi,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
F. Boffelli,
V. Boldrini,
E. D. Brandani,
C. Brofferio,
C. Bucci,
M. Buchynska,
J. Camilleri
, et al. (166 additional authors not shown)
Abstract:
CUPID, the CUORE Upgrade with Particle Identification, is a next-generation experiment to search for neutrinoless double beta decay ($0νββ$) and other rare events using enriched Li$_2$$^{100}$MoO$_4$ scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for $0νββ$\ of $^{100}$Mo wit…
▽ More
CUPID, the CUORE Upgrade with Particle Identification, is a next-generation experiment to search for neutrinoless double beta decay ($0νββ$) and other rare events using enriched Li$_2$$^{100}$MoO$_4$ scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for $0νββ$\ of $^{100}$Mo with a discovery sensitivity covering the full neutrino mass regime in the inverted ordering scenario, as well as the portion of the normal ordering regime with lightest neutrino mass larger than 10 meV. With a conservative background index of 10$^{-4}$ cnts/(keV$\cdot$kg$\cdot$yr), 240 kg isotope mass, 5 keV FWHM energy resolution and 10 live-years of data taking, CUPID will have a 90\% C.L. half-life exclusion sensitivity of 1.8 $\cdot$ 10$^{27}$ yr, corresponding to an effective Majorana neutrino mass ($m_{ββ}$) sensitivity of 9--15 meV, and a $3σ$ discovery sensitivity of 1 $\cdot$ 10$^{27}$ yr, corresponding to an $m_{ββ}$ range of 12--21 meV.
△ Less
Submitted 1 March, 2025;
originally announced March 2025.
-
Search for fractionally charged particles with CUORE
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (95 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using th…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using the first tonne-year of CUORE's exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various Standard Model extensions and would have suppressed interactions with matter. No excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges between $e/24-e/5$ at 90\% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale sub-Kelvin detectors to diverse signatures of new physics.
△ Less
Submitted 18 June, 2024;
originally announced June 2024.
-
Data-driven background model for the CUORE experiment
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (93 additional authors not shown)
Abstract:
We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth explo…
▽ More
We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth exploration of both spatial and time dependence of backgrounds. We achieve high sensitivity to both bulk and surface activities of the materials of the setup, detecting levels as low as 10 nBq kg$^{-1}$ and 0.1 nBq cm$^{-2}$, respectively. We compare the contamination levels we extract from the background model with prior radio-assay data, which informs future background risk mitigation strategies. The results of this background model play a crucial role in constructing the background budget for the CUPID experiment as it will exploit the same CUORE infrastructure.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
Authors:
CUPID collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Campani,
C. Capelli
, et al. (154 additional authors not shown)
Abstract:
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of…
▽ More
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments
Authors:
CUPID,
CROSS collaborations,
:,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci
, et al. (160 additional authors not shown)
Abstract:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied…
▽ More
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, $μ$Bq/kg, level of the LMO crystals radioactive contamination by $^{228}$Th and $^{226}$Ra.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Search for Majoron-like particles with CUPID-0
Authors:
CUPID-0 Collaboration,
:,
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
V. Dompè,
G. Fantini
, et al. (29 additional authors not shown)
Abstract:
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the…
▽ More
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the existence of a Majoron-like boson coupling to the neutrino. The energy spectra arising from the emission of such bosons in the neutrinoless double $β$ decay have spectral indices $n=$ 1, 2, 3 or 7. We found no evidence of any of these decay modes, setting a lower limit (90% of credibility interval) on the half-life of 1.2 $\times$ 10$^{23}$ yr in the case of $n=$ 1, 3.8 $\times$ 10$^{22}$ yr for $n=$ 2, 1.4 $\times$ 10$^{22}$ yr for $n=$ 3 and 2.2 $\times$ 10$^{21}$ yr for $n=$ 7. These are the best limits on the $0νββχ_0$ half-life of the $^{82}$Se, and demonstrate the potentiality of the CUPID-0 technology in this field.
△ Less
Submitted 20 September, 2022;
originally announced September 2022.
-
Final Result on the Neutrinoless Double Beta Decay of $^{82}$Se with CUPID-0
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
F. De Dominics,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla
, et al. (23 additional authors not shown)
Abstract:
CUPID-0, an array of Zn$^{82}$Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers technology. The first project phase (March 2017 - December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, $^{82}$Se, to be set. After a six months long detector upgrade, CUPID-0 began its second and last…
▽ More
CUPID-0, an array of Zn$^{82}$Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers technology. The first project phase (March 2017 - December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, $^{82}$Se, to be set. After a six months long detector upgrade, CUPID-0 began its second and last phase (June 2019 - February 2020). In this letter, we describe the search for neutrinoless double beta decay of $^{82}$Se with a total exposure (phase I + II) of 8.82 kg$\times$yr of isotope. We set a limit on the half-life of $^{82}$Se to the ground state of $^{82}$Kr of T$^{0ν}_{1/2}$($^{82}$Se)$>$ 4.6$\times \mathrm{10}^{24}$ yr (90\% credible interval), corresponding to an effective Majorana neutrino mass m$_{ββ} <$ (263 -- 545) meV. We also set the most stringent lower limits on the neutrinoless decays of $^{82}$Se to the 0$_1^+$, 2$_1^+$ and 2$_2^+$ excited states of $^{82}$Kr, finding 1.8$\times$10$^{23}$ yr, 3.0$\times$10$^{23}$ yr, 3.2$\times$10$^{23}$ yr (90$\%$ credible interval) respectively.
△ Less
Submitted 10 June, 2022;
originally announced June 2022.
-
An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali
, et al. (96 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear therm…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.
△ Less
Submitted 28 July, 2022; v1 submitted 9 May, 2022;
originally announced May 2022.
-
KATRIN: Status and Prospects for the Neutrino Mass and Beyond
Authors:
M. Aker,
M. Balzer,
D. Batzler,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
M. Biassoni,
B. Bieringer,
F. Block,
S. Bobien,
L. Bombelli,
D. Bormann,
B. Bornschein,
L. Bornschein,
M. Böttcher,
C. Brofferio,
C. Bruch,
T. Brunst,
T. S. Caldwell,
M. Carminati,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
O. Cremonesi
, et al. (137 additional authors not shown)
Abstract:
The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a su…
▽ More
The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a sub-eV sensitivity. After 1000 days of data-taking, KATRIN's design sensitivity is 0.2 eV at the 90% confidence level. In this white paper we describe the current status of KATRIN; explore prospects for measuring the neutrino mass and other physics observables, including sterile neutrinos and other beyond-Standard-Model hypotheses; and discuss research-and-development projects that may further improve the KATRIN sensitivity.
△ Less
Submitted 16 June, 2023; v1 submitted 15 March, 2022;
originally announced March 2022.
-
Optimization of the first CUPID detector module
Authors:
CUPID collaboration,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli
, et al. (153 additional authors not shown)
Abstract:
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the…
▽ More
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.
△ Less
Submitted 13 February, 2022;
originally announced February 2022.
-
CUORE Opens the Door to Tonne-scale Cryogenics Experiments
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
F. Alessandria,
K. Alfonso,
E. Andreotti,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
M. Beretta,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri
, et al. (184 additional authors not shown)
Abstract:
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve…
▽ More
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
△ Less
Submitted 2 December, 2021; v1 submitted 17 August, 2021;
originally announced August 2021.
-
Radioactivity control strategy for the JUNO detector
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (578 additional authors not shown)
Abstract:
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particula…
▽ More
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particular, natural radioactivity present in all materials and in the environment represents a serious issue that could impair the sensitivity of the experiment if appropriate countermeasures were not foreseen. In this paper we discuss the background reduction strategies undertaken by the JUNO collaboration to reduce at minimum the impact of natural radioactivity. We describe our efforts for an optimized experimental design, a careful material screening and accurate detector production handling, and a constant control of the expected results through a meticulous Monte Carlo simulation program. We show that all these actions should allow us to keep the background count rate safely below the target value of 10 Hz in the default fiducial volume, above an energy threshold of 0.7 MeV.
△ Less
Submitted 13 October, 2021; v1 submitted 8 July, 2021;
originally announced July 2021.
-
Background identification in cryogenic calorimeters through $α-α$ delayed coincidences
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
A. D'Addabbo,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel,
M. Martinez
, et al. (20 additional authors not shown)
Abstract:
Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $α-α$ delayed coincidences in $^{232}$Th and $^{238}$U decay chains, developed to inv…
▽ More
Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $α-α$ delayed coincidences in $^{232}$Th and $^{238}$U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the $α$ decay position.
△ Less
Submitted 13 August, 2021; v1 submitted 7 May, 2021;
originally announced May 2021.
-
Measurement of $^{216}$Po half-life with the CUPID-0 experiment
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
V. Caracciolo,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
A. D'Addabbo,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti
, et al. (22 additional authors not shown)
Abstract:
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited ex…
▽ More
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited exposure. In this paper, we present a further application. Exploiting the analysis of delayed coincidence, we can identify the signals caused by the $^{220}$Rn-$^{216}$Po decay sequence on an event-by-event basis. The analysis of these events allows us to extract the time differences between the two decays, leading to a new evaluation of $^{216}$ half-life, estimated as (143.3 $\pm$ 2.8) ms.
△ Less
Submitted 12 May, 2021; v1 submitted 7 May, 2021;
originally announced May 2021.
-
Modelling the shape of thermal pulses from low temperature detectors
Authors:
Irene Nutini,
Carlo Bucci,
Oliviero Cremonesi
Abstract:
Low temperature detectors are nowadays a technology widely used for rare events studies, such as the search for dark matter candidates and neutrino-less double beta decay. The convolution of the thermal and electrical response of these detectors results in pulses with different shapes depending on the materials, dimensions and operating conditions of the thermal sensors. It appears crucial to obta…
▽ More
Low temperature detectors are nowadays a technology widely used for rare events studies, such as the search for dark matter candidates and neutrino-less double beta decay. The convolution of the thermal and electrical response of these detectors results in pulses with different shapes depending on the materials, dimensions and operating conditions of the thermal sensors. It appears crucial to obtain a good description of the pulse shape, in order to possibly understand the several contributions in the thermal pulse formation. In this work, we present a general approach which allows us to model the shape of thermal pulses from different low temperature detectors.
△ Less
Submitted 30 March, 2021; v1 submitted 13 January, 2021;
originally announced January 2021.
-
A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility
Authors:
The CUPID Interest Group,
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
Ch. Bourgeois,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. M. Calvo-Mozota,
J. Camilleri
, et al. (156 additional authors not shown)
Abstract:
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 an…
▽ More
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $γ$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$σ$) between $γ$($β$) and $α$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $μ$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2β$ decay in CROSS and CUPID projects.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergè,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (147 additional authors not shown)
Abstract:
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta…
▽ More
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Novel technique for the study of pile-up events in cryogenic bolometers
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (144 additional authors not shown)
Abstract:
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our ap…
▽ More
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15ms down to time separation between the individual events of about 2ms.
△ Less
Submitted 12 July, 2021; v1 submitted 23 November, 2020;
originally announced November 2020.
-
New results from the CUORE experiment
Authors:
A. Giachero,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa
, et al. (88 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its 2\textsuperscript{nd} result of the search for $0νββ$ with a TeO$_2$ exposure of 372.5 kg$\cdot$yr and a median exclusion sensitivity to a $^{130}$Te $0νββ$ decay half-life of $1.7\cdot 10^{25}$ yr. We find no evidence for $0νββ$ decay and set a 90\% C.I. (credibility interval) Bayesian lower limit of $3.2\cdot 10^{25}$ yr on the $^{130}$Te $0νββ$ decay half-life. In this work, we present the current status of CUORE's search for $0νββ$, as well as review the detector performance. Finally, we give an update of the CUORE background model and the measurement of the $^{130}$Te two neutrino double-beta ($2νββ$) decay half-life.
△ Less
Submitted 7 January, 2021; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Characterization of a Silicon Drift Detector for High-Resolution Electron Spectroscopy
Authors:
Matteo Gugiatti,
Matteo Biassoni,
Marco Carminati,
Oliviero Cremonesi,
Carlo Fiorini,
Pietro King,
Peter Lechner,
Susanne Mertens,
Lorenzo Pagnanini,
Maura Pavan,
Stefano Pozzi
Abstract:
Silicon Drift Detectors, widely employed in high-resolution and high-rate X-ray applications, are considered here with interest also for electron detection. The accurate measurement of the tritium beta decay is the core of the TRISTAN (TRitium Investigation on STerile to Active Neutrino mixing) project. This work presents the characterization of a single-pixel SDD detector with a mono-energetic el…
▽ More
Silicon Drift Detectors, widely employed in high-resolution and high-rate X-ray applications, are considered here with interest also for electron detection. The accurate measurement of the tritium beta decay is the core of the TRISTAN (TRitium Investigation on STerile to Active Neutrino mixing) project. This work presents the characterization of a single-pixel SDD detector with a mono-energetic electron beam obtained from a Scanning Electron Microscope. The suitability of the SDD to detect electrons, in the energy range spanning from few keV to tens of keV, is demonstrated. Experimental measurements reveal a strong effect of the detector's entrance window structure on the observed energy response. A detailed detector model is therefore necessary to reconstruct the spectrum of an unknown beta-decay source.
△ Less
Submitted 27 June, 2020; v1 submitted 24 June, 2020;
originally announced June 2020.
-
Electron spectrometry with SDDs: a GEANT4 based method for detector response reconstruction
Authors:
Matteo Biassoni,
Matteo Gugiatti,
Silvia Capelli,
Marco Carminati,
Oliviero Cremonesi,
Carlo Fiorini,
Peter Lechner,
Susanne Mertens,
Lorenzo Pagnanini,
Maura Pavan,
Stefano Pozzi
Abstract:
Electron spectrometry is traditionally challenging due to the difficulty of correctly reconstructing the original energy of the detected electrons. Silicon Drift Detectors, extensively used for X-ray spectrometry, are a promising technology for the precise measurement of electrons energy. The ability to correctly model the detector entrance window response to the energy deposited by electrons is a…
▽ More
Electron spectrometry is traditionally challenging due to the difficulty of correctly reconstructing the original energy of the detected electrons. Silicon Drift Detectors, extensively used for X-ray spectrometry, are a promising technology for the precise measurement of electrons energy. The ability to correctly model the detector entrance window response to the energy deposited by electrons is a critical aspect of this application. We hereby describe a MonteCarlo-based approach to this problem, together with characterization and validation measurements performed with electron beams from a Scanning Electron Microscope.
△ Less
Submitted 25 March, 2020;
originally announced March 2020.
-
First search for Lorentz violation in double beta decay with scintillating calorimeters
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel,
M. Martinez,
S. Nagorny
, et al. (20 additional authors not shown)
Abstract:
We present the search for Lorentz violation in the double beta decay of ^{82}Se~with CUPID-0, using an exposure of 9.95 kg x y. We found no evidence for the searched signal and set a limit on the isotropic components of the Lorentz violating coefficient of $\mathring{a}_{\text{of}}^{(3)} < 4.1\cdot10^{-6}$ GeV (90\% Credible Interval). This results is obtained with a Bayesian analysis of the exper…
▽ More
We present the search for Lorentz violation in the double beta decay of ^{82}Se~with CUPID-0, using an exposure of 9.95 kg x y. We found no evidence for the searched signal and set a limit on the isotropic components of the Lorentz violating coefficient of $\mathring{a}_{\text{of}}^{(3)} < 4.1\cdot10^{-6}$ GeV (90\% Credible Interval). This results is obtained with a Bayesian analysis of the experimental data and fully includes the systematic uncertainties of the model. This is the first limit on $\mathring{a}_{\text{of}}^{(3)}$ obtained with a scintillating bolometer, showing the potentiality of this technique.
△ Less
Submitted 6 November, 2019;
originally announced November 2019.
-
Final result of CUPID-0 phase-I in the search for the $^{82}$Se Neutrinoless Double Beta Decay
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel,
M. Martinez,
S. Nagorny
, et al. (19 additional authors not shown)
Abstract:
CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0$ν$DBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a $^{82}$Se exposure of 5.29 kg$\times$yr. In this paper w…
▽ More
CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0$ν$DBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a $^{82}$Se exposure of 5.29 kg$\times$yr. In this paper we present the phase-I results in the search for 0$ν$DBD. We demonstrate that the technology implemented by CUPID-0 allows us to reach the lowest background for calorimetric experiments: $(3.5^{+1.0}_{-0.9})\times10^{-3}$ counts/(keV kg yr). Monitoring 3.88$\times$10$^{25}$ $^{82}$Se nuclei$\times$yr we reach a 90% credible interval median sensitivity of $\rm{T}^{0ν}_{1/2}>5.0\times10^{24} \rm{yr}$ and set the most stringent limit on the half-life of $^{82}$Se 0$ν$DBD : $\rm{T}^{0ν}_{1/2}>3.5\times10^{24} \rm{yr}$ (90% credible interval), corresponding to m$_{ββ} <$ (311-638) meV depending on the nuclear matrix element calculations.
△ Less
Submitted 12 June, 2019;
originally announced June 2019.
-
A novel application of solid state detectors for high precision, low systematics measurement of beta decay energy spectra of interest for neutrino and nuclear physics
Authors:
Matteo Biassoni,
Marco Carminati,
Luigi Coraggio,
Oliviero Cremonesi,
Carlo Fiorini,
Claudio Gotti,
Matteo Gugiatti,
Lorenzo Pagnanini,
Maura Pavan,
Stefano Pozzi
Abstract:
This project is focused on the development of a novel strategy for the precise measurement of beta decay energy spectra. The exact determination of beta spectra has wide implications in the particle and nuclear physics fields: from sterile neutrino searches \cite{Adhikari 2016} to validation of nuclear models of interest for double beta decay searches \cite{Suhonen 2017}, to reactor neutrino exper…
▽ More
This project is focused on the development of a novel strategy for the precise measurement of beta decay energy spectra. The exact determination of beta spectra has wide implications in the particle and nuclear physics fields: from sterile neutrino searches \cite{Adhikari 2016} to validation of nuclear models of interest for double beta decay searches \cite{Suhonen 2017}, to reactor neutrino experiments. The experimental strategy is focused on the mitigation of the systematic uncertainty in the determination of the spectral shape related to the energy response of the detector. The plan is to use Silicon Drift Detectors (SDDs), exploiting their excellent energy resolution and response uniformity, the thin dead layer and the fast signal that allows high rate operations. A complete modeling of SDDs response to the interaction of beta particles via numerical simulations, validated with dedicated measurements, aims at identifying and canceling the detector-related systematics. Similar attention will be devoted to the integration of beta radioactive sources that preserve the energy information carried by the emitted electrons, and to a veto system with a full solid angle coverage to intercept any escaping particle potentially carrying a fraction of the original electron energy.
△ Less
Submitted 27 May, 2019;
originally announced May 2019.
-
Background Model of the CUPID-0 Experiment
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel,
M. Martinez,
S. Nagorny
, et al. (19 additional authors not shown)
Abstract:
CUPID-0 is the first large mass array of enriched Zn$^{82}$Se scintillating low temperature calorimeters, operated at LNGS since 2017. During its first scientific runs, CUPID-0 collected an exposure of 9.95 kg yr. Thanks to the excellent rejection of $α$ particles, we attained the lowest background ever measured with thermal detectors in the energy region where we search for the signature of…
▽ More
CUPID-0 is the first large mass array of enriched Zn$^{82}$Se scintillating low temperature calorimeters, operated at LNGS since 2017. During its first scientific runs, CUPID-0 collected an exposure of 9.95 kg yr. Thanks to the excellent rejection of $α$ particles, we attained the lowest background ever measured with thermal detectors in the energy region where we search for the signature of $^{82}$Se neutrinoless double beta decay. In this work we develop a model to reconstruct the CUPID-0 background over the whole energy range of experimental data. We identify the background sources exploiting their distinctive signatures and we assess their extremely low contribution (down to $\sim10^{-4}$ counts/(keV kg yr)) in the region of interest for $^{82}$Se neutrinoless double beta decay search. This result represents a crucial step towards the comprehension of the background in experiments based on scintillating calorimeters and in next generation projects such as CUPID.
△ Less
Submitted 17 July, 2019; v1 submitted 23 April, 2019;
originally announced April 2019.
-
The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
Authors:
C. Alduino,
F. Alessandria,
M. Balata,
D. Biare,
M. Biassoni,
C. Bucci,
A. Caminata,
L. Canonica,
L. Cappelli,
G. Ceruti,
A. Chiarini,
N. Chott,
M. Clemenza,
S. Copello,
A. Corsi,
O. Cremonesi,
A. D'Addabbo,
S. Dell'Oro,
L. Di Paolo,
M. L. Di Vacri,
A. Drobizhev,
M. Faverzani,
E. Ferri,
M. A. Franceschi,
R. Gaigher
, et al. (31 additional authors not shown)
Abstract:
The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, requ…
▽ More
The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE.
△ Less
Submitted 12 July, 2019; v1 submitted 8 April, 2019;
originally announced April 2019.
-
Radiopurity of an archeological Roman Lead cryogenic detector
Authors:
L. Pattavina,
J. W. Beeman,
M. Clemenza,
O. Cremonesi,
E. Fiorini,
L. Pagnanini,
S. Pirro,
C. Rusconi,
K. Schäffner
Abstract:
Archeological Roman lead (Pb) is known to be a suitable material for shielding experimental apparata in rare event searches. In the past years the intrinsic radiopurity of this material was investigated using different technologies. In this work we applied the latest advancements in cryogenic techniques to study the bulk radiopurity of a 1 cm$^{3}$ sample of archeological Roman Pb. We report the l…
▽ More
Archeological Roman lead (Pb) is known to be a suitable material for shielding experimental apparata in rare event searches. In the past years the intrinsic radiopurity of this material was investigated using different technologies. In this work we applied the latest advancements in cryogenic techniques to study the bulk radiopurity of a 1 cm$^{3}$ sample of archeological Roman Pb. We report the lowest ever measured limit on $^{210}$Pb content in Roman Pb, with a concentration lower than 715 $μ$Bq/kg. Furthermore, we also studied $^{238}$U and $^{232}$Th impurity concentrations. Our values concur with independent measurements reported in literature.
△ Less
Submitted 8 July, 2019; v1 submitted 8 April, 2019;
originally announced April 2019.
-
Double-beta decay of ${}^{130}$Te to the first $0^+$ excited state of ${}^{130}$Xe with CUORE-0
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (96 additional authors not shown)
Abstract:
We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the ha…
▽ More
We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the half-lives: $τ^{0ν}_{0^+}>7.9\cdot 10^{23}$ yr and $τ^{2ν}_{0^+}>2.4\cdot 10^{23}$ yr. Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: $τ^{0ν}_{0^+}>1.4\cdot 10^{24}$ yr and $τ^{2ν}_{0^+}>2.5\cdot 10^{23}$ yr.
△ Less
Submitted 29 November, 2018; v1 submitted 26 November, 2018;
originally announced November 2018.
-
Update on the recent progress of the CUORE experiment
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (96 additional authors not shown)
Abstract:
CUORE is a 741 kg array of 988 TeO$_2$ bolometeric crystals designed to search for the neutrinoless double beta decay of $^{130}$Te and other rare processes. CUORE has been taking data since summer 2017, and as of summer 2018 collected a total of 86.3 kg$\cdot$yr of TeO$_2$ exposure. Based on this exposure, we were able to set a limit on the $0νββ$ half-life of $^{130}$Te of…
▽ More
CUORE is a 741 kg array of 988 TeO$_2$ bolometeric crystals designed to search for the neutrinoless double beta decay of $^{130}$Te and other rare processes. CUORE has been taking data since summer 2017, and as of summer 2018 collected a total of 86.3 kg$\cdot$yr of TeO$_2$ exposure. Based on this exposure, we were able to set a limit on the $0νββ$ half-life of $^{130}$Te of $T^{0ν}_{1/2}>1.5\times10^{25}$ yr at 90% C.L. At this conference, we showed the decomposition of the CUORE background and were able to extract a $^{130}$Te $2νββ$ half-life of $T_{1/2}^{2ν}=[7.9\pm0.1 \mathrm{(stat.)}\pm0.2 \mathrm{(syst.)}]\times10^{20}$ yr. This is the most precise measurement of this half-life and is consistent with previous measurements.
△ Less
Submitted 30 August, 2018;
originally announced August 2018.
-
Search of the neutrino-less double beta decay of $^{82}$Se into the excited states of $^{82}$Kr with CUPID-0
Authors:
O. Azzolini,
M. T. Barrera,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
E. Bossio,
C. Brofferio,
C. Bucci,
L. Canonica,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla
, et al. (25 additional authors not shown)
Abstract:
The CUPID0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95$\%$ enriched in $^{82}$Se and 2 natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of $^{82}$Se into the 0$_1^+$, 2$_1^+$ and 2…
▽ More
The CUPID0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95$\%$ enriched in $^{82}$Se and 2 natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of $^{82}$Se into the 0$_1^+$, 2$_1^+$ and 2$_2^+$ excited states of $^{82}$Kr with an exposure of 5.74 kg$\cdot$yr (2.24$\times$10$^{25}$ emitters$\cdot$yr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: $Γ$($^{82}$Se $\rightarrow ^{82}$Kr$_{0_1^+}$)$<$8.55$\times$10$^{-24}$ yr$^{-1}$, $Γ$($^{82}$Se $\rightarrow ^{82}$Kr$_{2_1^+}$)$<6.25 \times10^{-24}$ yr$^{-1}$, $Γ$($^{82}$Se $\rightarrow ^{82}$Kr$_{2_2^+}$)$<$8.25$\times$10$^{-24}$ yr$^{-1}$ (90$\%$ credible interval
△ Less
Submitted 18 October, 2018; v1 submitted 2 July, 2018;
originally announced July 2018.
-
Analysis of cryogenic calorimeters with light and heat read-out for double beta decay searches
Authors:
O. Azzolini,
M. T. Barrera,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
E. Bossio,
C. Brofferio,
C. Bucci,
L. Canonica,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casalia,
L. Cassina,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla
, et al. (25 additional authors not shown)
Abstract:
The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation lig…
▽ More
The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation light. CUPID-0, an array of enriched Zn$^{82}$Se scintillating calorimeters, is the first large mass demonstrator of this technology. The detector started data-taking in 2017 at the Laboratori Nazionali del Gran Sasso with the aim of proving that dual read-out of light and heat allows for an efficient suppression of the α background. In this paper we describe the software tools we developed for the analysis of scintillating calorimeters and we demonstrate that this technology allows to reach an unprecedented background for cryogenic calorimeters.
△ Less
Submitted 30 August, 2018; v1 submitted 7 June, 2018;
originally announced June 2018.
-
The CUORE cryostat
Authors:
A. D'Addabbo,
M. Biassoni,
C. Bucci,
A. Caminata,
C. Alduino,
A. Bersani,
L. Canonica,
L. Cappelli,
G. Ceruti,
N. Chott,
S. Copello,
O. Cremonesi,
J. S. Cushman,
D. D'Aguanno,
C. J. Davis,
S. Dell'Oro,
S. Di Domizio,
A. Drobizhev,
M. Faverzani,
E. Ferri,
M. A. Franceschi,
L. Gladstone,
P. Gorla,
C. Ligi,
L. Marini
, et al. (16 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is a bolometric experiment for neutrinoless double-beta decay in $^{130}$Te search, currently taking data at the underground facility of Laboratori Nazionali del Gran Sasso (LNGS). The CUORE cryostat successfully cooled down a mass of about 1 ton at $\sim$7\,mK, delivering an uniform and constant base temperature. This result marks a fu…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is a bolometric experiment for neutrinoless double-beta decay in $^{130}$Te search, currently taking data at the underground facility of Laboratori Nazionali del Gran Sasso (LNGS). The CUORE cryostat successfully cooled down a mass of about 1 ton at $\sim$7\,mK, delivering an uniform and constant base temperature. This result marks a fundamental milestone in low temperature detectors techniques, opening the path for future ton-scale bolometric experiments searching for rare events. In this paper we present the CUORE cryogenic infrastructure, briefly describing its critical subsystems.
△ Less
Submitted 30 August, 2018; v1 submitted 16 May, 2018;
originally announced May 2018.
-
First Result on the Neutrinoless Double Beta Decay of $^{82}$Se with CUPID-0
Authors:
CUPID-0 collaboration,
:,
O. Azzolini,
M. T. Barrera,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
L. Canonica,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani
, et al. (28 additional authors not shown)
Abstract:
We report the result of the search for neutrinoless double beta decay of $^{82}$Se obtained with CUPID-0, the first large array of scintillating Zn$^{82}$Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr $^{82}$Se exposure and we set the most stringent lower limit on the \onu $^{82}$Se half-life T$^{0ν}_{1/2}>$ 2.4$\times \mathrm{10}^{24}$ yr (90\…
▽ More
We report the result of the search for neutrinoless double beta decay of $^{82}$Se obtained with CUPID-0, the first large array of scintillating Zn$^{82}$Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr $^{82}$Se exposure and we set the most stringent lower limit on the \onu $^{82}$Se half-life T$^{0ν}_{1/2}>$ 2.4$\times \mathrm{10}^{24}$ yr (90\% credible interval), which corresponds to an effective Majorana neutrino mass m$_{ββ} <$ (376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of \al\ particles and allows to suppress the background in the region of interest down to (3.6$^{+1.9}_{-1.4}$)$\times$10$^{-3}$\ckky, an unprecedented level for this technique.
△ Less
Submitted 5 June, 2018; v1 submitted 21 February, 2018;
originally announced February 2018.
-
CUPID-0: the first array of enriched scintillating bolometers for 0νββdecay investigations
Authors:
O. Azzolini,
M. T. Barrera,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
L. Canonica,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti
, et al. (25 additional authors not shown)
Abstract:
The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of $^{82}$Se neutrinoless double-beta decay (0$νββ$). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0$νββ$ at the level of 10$^{-3}$ c/keV/kg/y, the lowest value ever measured using cryogenic d…
▽ More
The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of $^{82}$Se neutrinoless double-beta decay (0$νββ$). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0$νββ$ at the level of 10$^{-3}$ c/keV/kg/y, the lowest value ever measured using cryogenic detectors. This result can be achieved by a state of the art technology for background suppression and thorough protocols and procedures for detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising detector performance which are here preliminarily discussed
△ Less
Submitted 28 February, 2018; v1 submitted 19 February, 2018;
originally announced February 2018.
-
Study of Rare Nuclear Processes with CUORE
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa,
N. Chott
, et al. (94 additional authors not shown)
Abstract:
TeO2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0ν} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment look…
▽ More
TeO2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0ν} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment looking for neutrinoless double beta decay, it is not the only study that CUORE will contribute to in the field of nuclear and particle physics. As already done over the years with many small-scale experiments, CUORE will investigate both rare decays (such as the two-neutrino double beta decay of 130-Te and the hypothesized electron capture in 123-Te), and rare processes (e.g., dark matter and axion interactions). This paper describes some of the achievements of past experiments that used TeO2 bolometers, and perspectives for CUORE.
△ Less
Submitted 17 January, 2018; v1 submitted 16 January, 2018;
originally announced January 2018.
-
First Results from CUORE: A Search for Lepton Number Violation via $0νββ$ Decay of $^{130}$Te
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
E. Andreotti,
C. Arnaboldi,
F. T. Avignone III,
O. Azzolini,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
D. Biare,
M. Biassoni,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri,
C. Bucci,
C. Bulfon,
A. Camacho,
A. Caminata
, et al. (140 additional authors not shown)
Abstract:
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure…
▽ More
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we find no evidence for neutrinoless double-beta decay. The median statistical sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic uncertainties, we place a lower limit on the decay half-life of $T^{0ν}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find $T^{0ν}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find $m_{ββ}<(110 - 520)$ meV, where the range reflects the nuclear matrix element estimates employed.
△ Less
Submitted 1 April, 2018; v1 submitted 22 October, 2017;
originally announced October 2017.
-
Low Energy Analysis Techniques for CUORE
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
G. Bari,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina
, et al. (99 additional authors not shown)
Abstract:
CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searc…
▽ More
CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils in CUORE-0.
△ Less
Submitted 14 December, 2017; v1 submitted 25 August, 2017;
originally announced August 2017.
-
CUORE Sensitivity to $0νββ$ Decay
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti
, et al. (106 additional authors not shown)
Abstract:
We report a study of the CUORE sensitivity to neutrinoless double beta ($0νββ$) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the $0νββ$ decay half-life ($T_{1/2}^{0ν}$) at $90\%$ credibility interval (CI) -- i.e. the interval containing the true value of $T_{1/2}^{0ν}$ with $90\%$ probability -- and the $3 σ$ discovery sensitiv…
▽ More
We report a study of the CUORE sensitivity to neutrinoless double beta ($0νββ$) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the $0νββ$ decay half-life ($T_{1/2}^{0ν}$) at $90\%$ credibility interval (CI) -- i.e. the interval containing the true value of $T_{1/2}^{0ν}$ with $90\%$ probability -- and the $3 σ$ discovery sensitivity. We consider various background levels and energy resolutions, and describe the influence of the data division in subsets with different background levels. If the background level and the energy resolution meet the expectation, CUORE will reach a $90\%$ CI exclusion sensitivity of $2\cdot10^{25}$ yr with $3$ months, and $9\cdot10^{25}$ yr with $5$ years of live time. Under the same conditions, the discovery sensitivity after $3$ months and $5$ years will be $7\cdot10^{24}$ yr and $4\cdot10^{25}$ yr, respectively.
△ Less
Submitted 14 August, 2017; v1 submitted 30 May, 2017;
originally announced May 2017.
-
The projected background for the CUORE experiment
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti
, et al. (107 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to search for neutrinoless double beta decay of 130Te with an array of 988 TeO2 bolometers operating at temperatures around 10 mK. The experiment is currently being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay half-lif…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to search for neutrinoless double beta decay of 130Te with an array of 988 TeO2 bolometers operating at temperatures around 10 mK. The experiment is currently being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay half-life of 9$\times$10$^{25}$ years after 5\,years of data taking. The main issue to be addressed to accomplish this aim is the rate of background events in the region of interest, which must not be higher than 10$^{-2}$\,counts/keV/kg/y. We developed a detailed Monte Carlo simulation, based on results from a campaign of material screening, radioassays, and bolometric measurements, to evaluate the expected background. This was used over the years to guide the construction strategies of the experiment and we use it here to project a background model for CUORE. In this paper we report the results of our study and our expectations for the background rate in the energy region where the peak signature of neutrinoless double beta decay of 130Te is expected.
△ Less
Submitted 31 August, 2017; v1 submitted 28 April, 2017;
originally announced April 2017.
-
The CUORE and CUORE-0 experiments at LNGS
Authors:
A. D'Addabbo,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Camacho,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti,
N. Casali
, et al. (100 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton scale bolometric experiment devoted to the search of the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) in 130Te. The CUORE detector consists of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE demonstrator: it has been built to test the performance of the upcoming CUORE experiment and represents the l…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton scale bolometric experiment devoted to the search of the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) in 130Te. The CUORE detector consists of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE demonstrator: it has been built to test the performance of the upcoming CUORE experiment and represents the largest 130Te bolometric setup ever operated. CUORE-0 has been running at Laboratori Nazionali del Gran Sasso (Italy) from 2013 to 2015. The final CUORE-0 analysis on 0ν\b{eta}\b{eta} and the corresponding detector performance are presented. The present status of the CUORE experiment, now in its final construction and commissioning phase, are discussed. The results from assembly of the detector and the commissioning of the cryostat are reported.
△ Less
Submitted 13 December, 2016;
originally announced December 2016.
-
First array of enriched Zn$^{82}$Se bolometers to search for double beta decay
Authors:
D. R. Artusa,
A. Balzoni,
J. W. Beeman,
F. Bellini,
M. Biassoni,
C. Brofferio,
A. Camacho,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
M. L. di Vacri,
F. Ferroni,
L. Gironi,
A. Giuliani,
C. Gotti,
G. Keppel,
M. Maino
, et al. (25 additional authors not shown)
Abstract:
The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in $^{82}$Se, the Zn$^{82}$Se crystals growth, as well as the light detectors production have been accomplished, and the expe…
▽ More
The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in $^{82}$Se, the Zn$^{82}$Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn$^{82}$Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0.
△ Less
Submitted 16 June, 2016; v1 submitted 19 May, 2016;
originally announced May 2016.
-
CUORE-0 detector: design, construction and operation
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
C. Brofferio,
A. Buccheri,
C. Bucci,
C. Bulfon,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
M. Capodiferro,
L. Cappelli
, et al. (129 additional authors not shown)
Abstract:
The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the C…
▽ More
The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.
△ Less
Submitted 18 July, 2016; v1 submitted 19 April, 2016;
originally announced April 2016.
-
Cerenkov light identification with Si low-temperature detectors with Neganov-Luke effect-enhanced sensitivity
Authors:
L. Gironi,
M. Biassoni,
C. Brofferio,
S. Capelli,
P. Carniti,
L. Cassina,
M. Clemenza,
O. Cremonesi,
M. Faverzani,
E. Ferri,
E. Fossati,
A. Giachero,
C. Giordano,
C. Gotti,
M. Maino,
B. Margesin,
F. Moretti,
A. Nucciotti,
M. Pavan,
G. Pessina,
S. Pozzi,
E. Previtali,
A. Puiu,
M. Sisti,
F. Terranova
Abstract:
A new generation of cryogenic light detectors exploiting Neganov-Luke effect to enhance the thermal signal has been used to detect the Cherenkov light emitted by the electrons interacting in TeO$_{2}$ crystals. With this mechanism a high significance event-by-event discrimination between alpha and beta/gamma interactions at the $^{130}$Te neutrino-less double beta decay Q-value - (2527.515 $\pm$ 0…
▽ More
A new generation of cryogenic light detectors exploiting Neganov-Luke effect to enhance the thermal signal has been used to detect the Cherenkov light emitted by the electrons interacting in TeO$_{2}$ crystals. With this mechanism a high significance event-by-event discrimination between alpha and beta/gamma interactions at the $^{130}$Te neutrino-less double beta decay Q-value - (2527.515 $\pm$ 0.013) keV - has been demonstrated. This measurement opens the possibility of drastically reducing the background in cryogenic experiments based on TeO$_{2}$.
△ Less
Submitted 25 October, 2016; v1 submitted 25 March, 2016;
originally announced March 2016.
-
Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in $^{130}$Te with CUORE-0
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (96 additional authors not shown)
Abstract:
We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0νββ$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques develo…
▽ More
We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0νββ$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive $0νββ$ decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final $0νββ$ decay search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized $0νββ$ decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the $0νββ$ decay half-life limits previously reported for CUORE-0, $T^{0ν}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino limit, $T^{0ν}_{1/2}>4.0\times10^{24}$ yr.
△ Less
Submitted 27 April, 2016; v1 submitted 6 January, 2016;
originally announced January 2016.
-
Large area Si low-temperature light detectors with Neganov-Luke effect
Authors:
M. Biassoni,
C. Brofferio,
S. Capelli,
L. Cassina,
M. Clemenza,
O. Cremonesi,
M. Faverzani,
E. Ferri,
A. Giachero,
L. Gironi,
C. Giordano,
C. Gotti,
M. Maino,
B. Margesin,
A. Nucciotti,
M. Pavan,
G. Pessina,
E. Previtali,
A. Puiu,
M. Sisti,
F. Terranova
Abstract:
Next generation calorimetric experiments for the search of rare events rely on the detection of tiny amounts of light (of the order of 20 optical photons) to discriminate and reduce background sources and improve sensitivity. Calorimetric detectors are the simplest solution for photon detection at cryogenic (mK) temperatures. The development of silicon based light detectors with enhanced performan…
▽ More
Next generation calorimetric experiments for the search of rare events rely on the detection of tiny amounts of light (of the order of 20 optical photons) to discriminate and reduce background sources and improve sensitivity. Calorimetric detectors are the simplest solution for photon detection at cryogenic (mK) temperatures. The development of silicon based light detectors with enhanced performance thanks to the use of the Neganov-Luke effect is described. The aim of this research line is the production of high performance detectors with industrial-grade reproducibility and reliability.
△ Less
Submitted 31 July, 2015;
originally announced July 2015.
-
Search for Neutrinoless Double-Beta Decay of $^{130}$Te with CUORE-0
Authors:
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
N. Casali,
L. Cassina,
D. Chiesa,
N. Chott,
M. Clemenza
, et al. (93 additional authors not shown)
Abstract:
We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The me…
▽ More
We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The median 90%~C.L. lower-limit sensitivity of the experiment is $2.9\times 10^{24}~{\rm yr}$ and surpasses the sensitivity of previous searches. We find no evidence for neutrinoless double-beta decay of $^{130}$Te and place a Bayesian lower bound on the decay half-life, $T^{0ν}_{1/2}>$~$ 2.7\times 10^{24}~{\rm yr}$ at 90%~C.L. Combining CUORE-0 data with the 19.75~kg$\cdot$yr exposure of $^{130}$Te from the Cuoricino experiment we obtain $T^{0ν}_{1/2} > 4.0\times 10^{24}~\mathrm{yr}$ at 90%~C.L.~(Bayesian), the most stringent limit to date on this half-life. Using a range of nuclear matrix element estimates we interpret this as a limit on the effective Majorana neutrino mass, $m_{ββ}< 270$ -- $760~\mathrm{meV}$.
△ Less
Submitted 1 October, 2015; v1 submitted 9 April, 2015;
originally announced April 2015.