-
Euclid preparation. LIII. LensMC, weak lensing cosmic shear measurement with forward modelling and Markov Chain Monte Carlo sampling
Authors:
Euclid Collaboration,
G. Congedo,
L. Miller,
A. N. Taylor,
N. Cross,
C. A. J. Duncan,
T. Kitching,
N. Martinet,
S. Matthew,
T. Schrabback,
M. Tewes,
N. Welikala,
N. Aghanim,
A. Amara,
S. Andreon,
N. Auricchio,
M. Baldi,
S. Bardelli,
R. Bender,
C. Bodendorf,
D. Bonino,
E. Branchini,
M. Brescia,
J. Brinchmann,
S. Camera
, et al. (217 additional authors not shown)
Abstract:
LensMC is a weak lensing shear measurement method developed for Euclid and Stage-IV surveys. It is based on forward modelling in order to deal with convolution by a point spread function (PSF) with comparable size to many galaxies; sampling the posterior distribution of galaxy parameters via Markov Chain Monte Carlo; and marginalisation over nuisance parameters for each of the 1.5 billion galaxies…
▽ More
LensMC is a weak lensing shear measurement method developed for Euclid and Stage-IV surveys. It is based on forward modelling in order to deal with convolution by a point spread function (PSF) with comparable size to many galaxies; sampling the posterior distribution of galaxy parameters via Markov Chain Monte Carlo; and marginalisation over nuisance parameters for each of the 1.5 billion galaxies observed by Euclid. We quantified the scientific performance through high-fidelity images based on the Euclid Flagship simulations and emulation of the Euclid VIS images; realistic clustering with a mean surface number density of 250 arcmin$^{-2}$ ($I_{\rm E}<29.5$) for galaxies, and 6 arcmin$^{-2}$ ($I_{\rm E}<26$) for stars; and a diffraction-limited chromatic PSF with a full width at half maximum of $0.^{\!\prime\prime}2$ and spatial variation across the field of view. LensMC measured objects with a density of 90 arcmin$^{-2}$ ($I_{\rm E}<26.5$) in 4500 deg$^2$. The total shear bias was broken down into measurement (our main focus here) and selection effects (which will be addressed elsewhere). We found measurement multiplicative and additive biases of $m_1=(-3.6\pm0.2)\times10^{-3}$, $m_2=(-4.3\pm0.2)\times10^{-3}$, $c_1=(-1.78\pm0.03)\times10^{-4}$, $c_2=(0.09\pm0.03)\times10^{-4}$; a large detection bias with a multiplicative component of $1.2\times10^{-2}$ and an additive component of $-3\times10^{-4}$; and a measurement PSF leakage of $α_1=(-9\pm3)\times10^{-4}$ and $α_2=(2\pm3)\times10^{-4}$. When model bias is suppressed, the obtained measurement biases are close to Euclid requirement and largely dominated by undetected faint galaxies ($-5\times10^{-3}$). Although significant, model bias will be straightforward to calibrate given the weak sensitivity. LensMC is publicly available at https://gitlab.com/gcongedo/LensMC
△ Less
Submitted 2 December, 2024; v1 submitted 1 May, 2024;
originally announced May 2024.
-
Mesoscopic electron transport and atomic gases, a review of Frank W. J. Hekking's scientific work
Authors:
Luigi Amico,
Denis M. Basko,
F Sebastián Bergeret,
Olivier Buisson,
Hervé Courtois,
Rosario Fazio,
Wiebke Guichard,
Anna Minguzzi,
Jukka Pekola,
Gerd Schön,
S Bergeret
Abstract:
Frank W. J. Hekking performed his PhD work on "Aspects of Electron Transport in Semiconductor Nanostructures" at the TU Delft in 1992. He then worked as a postdoc at the University of Karlsruhe, the University of Minnesota, the Cavendish Laboratory at the University of Cambridge, and the Ruhr University at Bochum. In 1999 he joined the LPMMC (Laboratoire de Physique et Mod\' elisation des Milieux…
▽ More
Frank W. J. Hekking performed his PhD work on "Aspects of Electron Transport in Semiconductor Nanostructures" at the TU Delft in 1992. He then worked as a postdoc at the University of Karlsruhe, the University of Minnesota, the Cavendish Laboratory at the University of Cambridge, and the Ruhr University at Bochum. In 1999 he joined the LPMMC (Laboratoire de Physique et Mod\' elisation des Milieux Condens\' es) in Grenoble and was appointed Professor at the Universit\' e Joseph Fourier and afterwards Universit\' e Grenoble Alpes. Frank Hekking was nominated as a member of the Institut Universitaire de France, for the periods 2002-2007 and 2012-2017. This review provides an overview of his scientific contributions to several fields of mesoscopic electron transport and superconductivity as well as atomic gases, and is organized along sections describing the different themes.
△ Less
Submitted 2 July, 2018; v1 submitted 17 April, 2018;
originally announced April 2018.
-
A subKelvin scanning probe microscope for the electronic spectroscopy of an individual nano-device
Authors:
Thomas Quaglio,
Franck Dahlem,
Sylvain Martin,
Anne Gerardin,
Clemens Winkelmann,
Hervé Courtois
Abstract:
We present a combined scanning force and tunneling microscope working in a dilution refrigerator that is optimized for the study of individual electronic nano-devices. This apparatus is equipped with commercial piezo-electric positioners enabling the displacement of a sample below the probe over several hundred microns at very low temperature, without excessive heating. Atomic force microscopy bas…
▽ More
We present a combined scanning force and tunneling microscope working in a dilution refrigerator that is optimized for the study of individual electronic nano-devices. This apparatus is equipped with commercial piezo-electric positioners enabling the displacement of a sample below the probe over several hundred microns at very low temperature, without excessive heating. Atomic force microscopy based on a tuning fork resonator probe is used for cryogenic precise alignment of the tip with an individual device. We demonstrate the local tunneling spectroscopy of a hybrid Josephson junction as a function of its current bias.
△ Less
Submitted 25 September, 2012;
originally announced September 2012.