-
RAISE -- Radiology AI Safety, an End-to-end lifecycle approach
Authors:
M. Jorge Cardoso,
Julia Moosbauer,
Tessa S. Cook,
B. Selnur Erdal,
Brad Genereaux,
Vikash Gupta,
Bennett A. Landman,
Tiarna Lee,
Parashkev Nachev,
Elanchezhian Somasundaram,
Ronald M. Summers,
Khaled Younis,
Sebastien Ourselin,
Franz MJ Pfister
Abstract:
The integration of AI into radiology introduces opportunities for improved clinical care provision and efficiency but it demands a meticulous approach to mitigate potential risks as with any other new technology. Beginning with rigorous pre-deployment evaluation and validation, the focus should be on ensuring models meet the highest standards of safety, effectiveness and efficacy for their intende…
▽ More
The integration of AI into radiology introduces opportunities for improved clinical care provision and efficiency but it demands a meticulous approach to mitigate potential risks as with any other new technology. Beginning with rigorous pre-deployment evaluation and validation, the focus should be on ensuring models meet the highest standards of safety, effectiveness and efficacy for their intended applications. Input and output guardrails implemented during production usage act as an additional layer of protection, identifying and addressing individual failures as they occur. Continuous post-deployment monitoring allows for tracking population-level performance (data drift), fairness, and value delivery over time. Scheduling reviews of post-deployment model performance and educating radiologists about new algorithmic-driven findings is critical for AI to be effective in clinical practice. Recognizing that no single AI solution can provide absolute assurance even when limited to its intended use, the synergistic application of quality assurance at multiple levels - regulatory, clinical, technical, and ethical - is emphasized. Collaborative efforts between stakeholders spanning healthcare systems, industry, academia, and government are imperative to address the multifaceted challenges involved. Trust in AI is an earned privilege, contingent on a broad set of goals, among them transparently demonstrating that the AI adheres to the same rigorous safety, effectiveness and efficacy standards as other established medical technologies. By doing so, developers can instil confidence among providers and patients alike, enabling the responsible scaling of AI and the realization of its potential benefits. The roadmap presented herein aims to expedite the achievement of deployable, reliable, and safe AI in radiology.
△ Less
Submitted 24 November, 2023;
originally announced November 2023.
-
Seismic signals generated at a water-ice interface from smoothed particle hydrodynamic simulations
Authors:
Ross J. Turner,
Jared C. Magyar,
Sue Cook,
Anya M. Reading
Abstract:
The field of ice sheet, ice shelf and glacier-related seismology, cryoseismology, has seen rapid development in recent years. As concern grows for the implications of change in the great ice sheets of Greenland and Antarctica, so instrument advances and international field programs have expanded the availability of passive seismic datasets that contain records of glacier processes. Many glacier-re…
▽ More
The field of ice sheet, ice shelf and glacier-related seismology, cryoseismology, has seen rapid development in recent years. As concern grows for the implications of change in the great ice sheets of Greenland and Antarctica, so instrument advances and international field programs have expanded the availability of passive seismic datasets that contain records of glacier processes. Many glacier-related seismic signals are generated by melt water, so a need exists to better understand the seismic response of moving water on glaciers. We present an analytic framework to model seismic signals at the interface between moving water and ice based on either new or existing smoothed particle hydrodynamic (SPH) simulations. The framework is tailored to understanding the seismic body wave response of transient moving water events and produces a simulated dataset of water-ice collisions to predict the motion due to body waves at any location on the glacier. The synthetic acceleration time series generated are invariant to the simulation resolution, and consider frequency-dependent weak dispersion and attenuation due to the propagating medium. We illustrate the capability of our framework using end-member cases of water flow: the breaking of a supraglacial melt water lake dam with the subsequent flow of water through glacier channels with differing geometries. Our focus is on the waveform attributes rather than exact waveform matching in view of the dynamic nature of the glacier environment. The flexibility inherent in the computational framework will allow for the simulation of seismic signals generated by high-energy collisions in a variety of different water flow geometries. We make the code publicly available for the polar geophysics community with the aim of adding to the toolbox of available approaches to inform the future monitoring of melt water movement and related glacier processes.
△ Less
Submitted 3 April, 2023;
originally announced April 2023.
-
The drainage of glacier and ice sheet surface lakes
Authors:
Christian Schoof,
Sue Cook,
Bernd Kulessa,
Sarah Thompson
Abstract:
Supraglacial lakes play a central role in storing melt water, enhancing surface melt, and ultimately in driving ice flow and ice shelf melt through injecting water into the subglacial environment and facilitating fracturing. Here, we develop a model for the drainage of supraglacial lakes through the dissipation-driven incision of a surface channel. The model consists of the St Venant equations for…
▽ More
Supraglacial lakes play a central role in storing melt water, enhancing surface melt, and ultimately in driving ice flow and ice shelf melt through injecting water into the subglacial environment and facilitating fracturing. Here, we develop a model for the drainage of supraglacial lakes through the dissipation-driven incision of a surface channel. The model consists of the St Venant equations for flow in the channel, fed by an upstream lake reservoir, coupled with an equation for the evolution of channel elevation due to advection, uplift, and downward melting. After reduction to a `stream power'-type hyperbolic model, we show that lake drainage occurs above a critical rate of water supply to the lake due to the backward migration of a shock that incises the lake seal. The critical water supply rate depends on advection velocity and uplift (or more precisely, drawdown downstream of the lake) as well as model parameters such as channel wall roughness and the parameters defining the relationship between channel cross-section and wetted perimeter. Once lake drainage does occur, it can either continue until the lake is empty, or terminate early, leading to oscillatory cycles of lake filling and draining, with the latter favoured by large lake volumes and relatively small water supply rates.
△ Less
Submitted 28 October, 2021;
originally announced October 2021.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
New Test of the Gravitational $1/r^2$ Law at Separations down to 52 $μ$m
Authors:
J. G. Lee,
E. G. Adelberger,
T. S. Cook,
S. M. Fleischer,
B. R. Heckel
Abstract:
We tested the gravitational $1/r^2$ law using a stationary torsion-balance detector and a rotating attractor containing test bodies with both 18-fold and 120-fold azimuthal symmetries that simultaneously tests the $1/r^2$ law at two different length scales. We took data at detector-attractor separations between $52~μ$m and 3.0 mm. Newtonian gravity gave an excellent fit to our data, limiting with…
▽ More
We tested the gravitational $1/r^2$ law using a stationary torsion-balance detector and a rotating attractor containing test bodies with both 18-fold and 120-fold azimuthal symmetries that simultaneously tests the $1/r^2$ law at two different length scales. We took data at detector-attractor separations between $52~μ$m and 3.0 mm. Newtonian gravity gave an excellent fit to our data, limiting with 95\% confidence any gravitational-strength Yukawa interactions to ranges $< 38.6~μ$m.
△ Less
Submitted 26 February, 2020;
originally announced February 2020.
-
Enabling Simulation of High-Dimensional Micro-Macro Biophysical Models through Hybrid CPU and Multi-GPU Parallelism
Authors:
Steven Cook,
Tamar Shinar
Abstract:
Micro-macro models provide a powerful tool to study the relationship between microscale mechanisms and emergent macroscopic behavior. However, the detailed microscopic modeling may require tracking and evolving a high-dimensional configuration space at high computational cost. In this work, we present a parallel algorithm for simulation a high-dimensional micro-macro model of a gliding motility as…
▽ More
Micro-macro models provide a powerful tool to study the relationship between microscale mechanisms and emergent macroscopic behavior. However, the detailed microscopic modeling may require tracking and evolving a high-dimensional configuration space at high computational cost. In this work, we present a parallel algorithm for simulation a high-dimensional micro-macro model of a gliding motility assay. We utilize a holistic approach aligning the data residency and simulation scales with the hybrid CPU and multi-GPU hardware. With a combination of algorithmic modifications, GPU optimizations, and scaling to multiple GPUs, we achieve speedup factors of up to 27 over our previous hybrid CPU-GPU implementation and up to 540 over our single-threaded implementation. This approach enables micro-macro simulations of higher complexity and resolution than would otherwise be feasible.
△ Less
Submitted 12 August, 2019;
originally announced August 2019.
-
MuSIC: delivering the world's most intense muon beam
Authors:
S. Cook,
R. D'Arcy,
A. Edmonds,
M. Fukuda,
K. Hatanaka,
Y. Hino,
Y. Kuno,
M. Lancaster,
Y. Mori,
T. Ogitsu,
H. Sakamoto,
A. Sato,
N. H. Tran,
N. M. Truong,
M. Wing,
A. Yamamoto,
M. Yoshida
Abstract:
A new muon beamline, muon science innovative channel (MuSIC), was set up at the Research Centre for Nuclear Physics (RCNP), Osaka University, in Osaka, Japan, using the 392 MeV proton beam impinging on a target. The production of an intense muon beam relies on the efficient capture of pions, which subsequently decay to muons, using a novel superconducting solenoid magnet system. After the pion-cap…
▽ More
A new muon beamline, muon science innovative channel (MuSIC), was set up at the Research Centre for Nuclear Physics (RCNP), Osaka University, in Osaka, Japan, using the 392 MeV proton beam impinging on a target. The production of an intense muon beam relies on the efficient capture of pions, which subsequently decay to muons, using a novel superconducting solenoid magnet system. After the pion-capture solenoid the first $36^\circ$ of the curved muon transport line was commissioned and the muon flux was measured. In order to detect muons, a target of either copper or magnesium was placed to stop muons at the end of the muon beamline. Two stations of plastic scintillators located upstream and downstream from the muon target were used to reconstruct the decay spectrum of muons. In a complementary method to detect negatively-charged muons, the X-ray spectrum yielded by muonic atoms in the target were measured in a germanium detector. Measurements, at a proton beam current of 6 pA, yielded $(10.4 \pm 2.7) \times 10^5$ muons per Watt of proton beam power ($μ^+$ and $μ^-$), far in excess of other facilities. At full beam power (400 W), this implies a rate of muons of $(4.2 \pm 1.1) \times 10^8$ muons s$^{-1}$, amongst the highest in the world. The number of $μ^-$ measured was about a factor of 10 lower, again by far the most efficient muon beam produced. The set up is a prototype for future experiments requiring a high-intensity muon beam, such as a muon collider or neutrino factory, or the search for rare muon decays which would be a signature for phenomena beyond the Standard Model of particle physics. Such a muon beam can also be used in other branches of physics, nuclear and condensed matter, as well as other areas of scientific research.
△ Less
Submitted 25 October, 2016;
originally announced October 2016.
-
Stimulated emission of fast Alfvén waves within magnetically confined fusion plasmas
Authors:
J W S Cook,
R O Dendy,
S C Chapman
Abstract:
A fast Alfvén wave with finite amplitude is shown to grow by a stimulated emission process that we propose for exploitation in toroidal magnetically confined fusion plasmas. Stimulated emission occurs while the wave propagates inward through the outer mid-plane plasma, where a population inversion of the energy distribution of fusion-born ions is observed to arise naturally. Fully nonlinear first…
▽ More
A fast Alfvén wave with finite amplitude is shown to grow by a stimulated emission process that we propose for exploitation in toroidal magnetically confined fusion plasmas. Stimulated emission occurs while the wave propagates inward through the outer mid-plane plasma, where a population inversion of the energy distribution of fusion-born ions is observed to arise naturally. Fully nonlinear first principles simulations, which self-consistently evolve particles and fields under the Maxwell-Lorentz system, demonstrate this novel "alpha-particle channelling" scenario for the first time.
△ Less
Submitted 1 June, 2016;
originally announced June 2016.
-
Quantifying fusion born ion populations in magnetically confined plasmas using ion cyclotron emission
Authors:
L. Carbajal,
R. O. Dendy,
S. C. Chapman,
J. W. S. Cook
Abstract:
Ion cyclotron emission (ICE) offers unique promise as a diagnostic of the fusion born alpha-particle population in magnetically confined plasmas. Pioneering observations from JET and TFTR found that ICE intensity $P_{ICE}$ scales approximately linearly with the measured neutron flux from fusion reactions, and with the inferred concentration, $n_α/n_i$, of fusion-born alpha-particles confined withi…
▽ More
Ion cyclotron emission (ICE) offers unique promise as a diagnostic of the fusion born alpha-particle population in magnetically confined plasmas. Pioneering observations from JET and TFTR found that ICE intensity $P_{ICE}$ scales approximately linearly with the measured neutron flux from fusion reactions, and with the inferred concentration, $n_α/n_i$, of fusion-born alpha-particles confined within the plasma. We present fully nonlinear self-consistent kinetic simulations that reproduce this scaling for the first time. This resolves a longstanding question in the physics of fusion alpha-particle confinement and stability in MCF plasmas. It confirms the magnetoacoustic cyclotron instability (MCI) as the likely emission mechanism and greatly strengthens the basis for diagnostic exploitation of ICE in future burning plasmas.
△ Less
Submitted 1 June, 2016;
originally announced June 2016.
-
A New Resource for College Distance Education Astronomy Laboratory Exercises
Authors:
Nicole P. Vogt,
Stephen P. Cook,
Amy Smith Muise
Abstract:
This article introduces a set of distance education astronomy laboratory exercises for use by college students and instructors and discuss first usage results. This General Astronomy Education Source (GEAS) exercise set contains eight two-week projects designed to guide students through both core content and mathematical applications of general astronomy material. Projects are divided between hand…
▽ More
This article introduces a set of distance education astronomy laboratory exercises for use by college students and instructors and discuss first usage results. This General Astronomy Education Source (GEAS) exercise set contains eight two-week projects designed to guide students through both core content and mathematical applications of general astronomy material. Projects are divided between hands-on activities and computer-aided analyses of modern astronomical data. The suite of online resources includes student and instructor guides, laboratory report templates, learning objectives, video tutorials, plotting tools, and web-based applications that allow students to analyze both images and spectra of astronomical objects. A pilot usage study indicates that distance learners using these materials perform as well or better than a comparison cohort of on-campus students. We are actively seeking collaborators to use these resources in astronomy courses and other educational venues.
△ Less
Submitted 30 April, 2015;
originally announced May 2015.
-
Laser frequency stabilization based on steady-state spectral-hole burning in Eu$^{3+}$:Y$_2$SiO$_5$
Authors:
Shon Cook,
Till Rosenband,
David R. Leibrandt
Abstract:
We present and analyze a method of laser frequency stabilization via steady-state patterns of spectral holes in Eu$^{3+}$:Y$_2$SiO$_5$. Three regions of spectral holes are created, spaced in frequency by the ground state hyperfine splittings of $~^{151}$Eu$^{3+}$. The absorption pattern is shown not to degrade after days of laser frequency stabilization. An optical frequency comparison of a laser…
▽ More
We present and analyze a method of laser frequency stabilization via steady-state patterns of spectral holes in Eu$^{3+}$:Y$_2$SiO$_5$. Three regions of spectral holes are created, spaced in frequency by the ground state hyperfine splittings of $~^{151}$Eu$^{3+}$. The absorption pattern is shown not to degrade after days of laser frequency stabilization. An optical frequency comparison of a laser locked to such a steady-state spectral-hole pattern with an independent cavity-stabilized laser and a Yb optical lattice clock demonstrates a spectral-hole fractional frequency instability of $1.0\times10^{-15}~ τ^{-\frac{1}{2}}$ that averages to $8.5^{+4.8}_{-1.8}\times10^{-17}$ at $τ= 73$ s. Residual amplitude modulation at the frequency of the RF drive applied to the fiber-coupled electro-optic modulator is reduced to less than $1\times10^{-6}$ fractional amplitude modulation at $τ>$ 1 s by an active servo. The contribution of residual amplitude modulation to the laser frequency instability is further reduced by digital division of the transmission and incident photodetector signals to less than $1\times10^{-16}$ at $τ>$ 1 s.
△ Less
Submitted 9 April, 2015;
originally announced April 2015.
-
Fast particle-driven ion cyclotron emission (ICE) in tokamak plasmas and the case for an ICE diagnostic in ITER
Authors:
K. G. McClements,
R. D'Inca,
R. O. Dendy,
L. Carbajal,
S. C. Chapman,
J. W. S. Cook,
R. W. Harvey,
W. W. Heidbrink,
S. D. Pinches
Abstract:
Fast particle-driven waves in the ion cyclotron frequency range (ion cyclotron emission or ICE) have provided a valuable diagnostic of confined and escaping fast ions in many tokamaks. This is a passive, non-invasive diagnostic that would be compatible with the high radiation environment of deuterium-tritium plasmas in ITER, and could provide important information on fusion α-particles and beam io…
▽ More
Fast particle-driven waves in the ion cyclotron frequency range (ion cyclotron emission or ICE) have provided a valuable diagnostic of confined and escaping fast ions in many tokamaks. This is a passive, non-invasive diagnostic that would be compatible with the high radiation environment of deuterium-tritium plasmas in ITER, and could provide important information on fusion α-particles and beam ions in that device. In JET, ICE from confined fusion products scaled linearly with fusion reaction rate over six orders of magnitude and provided evidence that α-particle confinement was close to classical. In TFTR, ICE was observed from super-Alfvénic α-particles in the plasma edge. The intensity of beam-driven ICE in DIII-D is more strongly correlated with drops in neutron rate during fishbone excitation than signals from more direct beam ion loss diagnostics. In ASDEX Upgrade ICE is produced by both super-Alfvénic DD fusion products and sub-Alfvénic deuterium beam ions.
△ Less
Submitted 12 December, 2014;
originally announced December 2014.
-
Spectroscopy of Ba and Ba$^+$ deposits in solid xenon for barium tagging in nEXO
Authors:
B. Mong,
S. Cook,
T. Walton,
C. Chambers,
A. Craycraft,
C. Benitez-Medina,
K. Hall,
W. Fairbank Jr.,
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
V. Basque,
D. Beck,
M. Breidenbach,
T. Brunner,
G. F. Cao,
B. Cleveland,
M. Coon,
T. Daniels,
S. J. Daugherty,
R. DeVoe,
T. Didberidze,
J. Dilling,
M. J. Dolinski,
M. Dunford
, et al. (51 additional authors not shown)
Abstract:
Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in…
▽ More
Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in Ba$^+$ deposits is identified with some type of barium hydride molecule. Lower limits for the fluorescence quantum efficiency of the principal Ba emission transition are reported. Under current conditions, an image of $\le10^4$ Ba atoms can be obtained. Prospects for imaging single Ba atoms in solid xenon are discussed.
△ Less
Submitted 9 October, 2014;
originally announced October 2014.
-
An improved measurement of the 2νββ half-life of Xe-136 with EXO-200
Authors:
J. B. Albert,
M. Auger,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
D. Beck,
V. Belov,
C. Benitez-Medina,
J. Bonatt,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
J. Chaves,
B. Cleveland,
S. Cook,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
R. DeVoe,
A. Dobi
, et al. (72 additional authors not shown)
Abstract:
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those…
▽ More
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The Xe-136 2νββ half-life is found to be 2.165 +- 0.016 (stat) +- 0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any 2νββ decay to date.
△ Less
Submitted 29 January, 2014; v1 submitted 25 June, 2013;
originally announced June 2013.
-
The EXO-200 detector, part I: Detector design and construction
Authors:
M. Auger,
D. J. Auty,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
E. Beauchamp,
C. Benitez-Medina,
M. Breidenbach,
D. Chauhan,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
A. Coppens,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
A. Dobi,
M. J. Dolinski,
M. Dunford,
W. Fairbank Jr,
J. Farine,
P. Fierlinger
, et al. (56 additional authors not shown)
Abstract:
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most…
▽ More
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.
△ Less
Submitted 23 May, 2012; v1 submitted 10 February, 2012;
originally announced February 2012.
-
Xenon purity analysis for EXO-200 via mass spectrometry
Authors:
A. Dobi,
C. Hall,
S. Slutsky,
Y. -R. Yen,
B. Aharmin,
M. Auger,
P. S. Barbeau,
C. Benitez-Medina,
M. Breidenbach,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
I. Counts,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
M. Dixit,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (51 additional authors not shown)
Abstract:
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We ha…
▽ More
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.
△ Less
Submitted 5 September, 2011;
originally announced September 2011.
-
Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200
Authors:
N. Ackerman,
B. Aharmim,
M. Auger,
D. J. Auty,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
E. Beauchamp,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
E. Conti,
J. Cook,
S. Cook,
A. Coppens,
I. Counts,
W. Craddock,
T. Daniels,
M. V. Danilov,
C. G. Davis,
J. Davis,
R. deVoe
, et al. (78 additional authors not shown)
Abstract:
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, th…
▽ More
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.
△ Less
Submitted 22 November, 2011; v1 submitted 21 August, 2011;
originally announced August 2011.
-
A xenon gas purity monitor for EXO
Authors:
EXO Collaboration,
A. Dobi,
C. Hall,
S. Herrin,
A. Odian,
C. Y. Prescott,
P. C. Rowson,
N. Ackerman,
B. Aharmin,
M. Auger,
P. S. Barbeau,
K. Barry,
C. Benitez-Medina,
M. Breidenbach,
S. Cook,
I. Counts,
T. Daniels,
R. DeVoe,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
G. Giroux,
R. Gornea,
K. Graham
, et al. (35 additional authors not shown)
Abstract:
We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tu…
▽ More
We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tungsten filament. Lab tests and experiences in commissioning the EXO-200 double beta decay experiment are described. These devices can also be used on other noble gases.
△ Less
Submitted 9 June, 2011;
originally announced June 2011.
-
A magnetically-driven piston pump for ultra-clean applications
Authors:
F. LePort,
R. Neilson,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
I. Counts,
J. Davis,
R. deVoe,
M. J. Dolinski,
G. Gratta,
M. Green,
M. Montero Díez,
A. R. Müller,
K. O'Sullivan,
A. Rivas,
K. Twelker,
B. Aharmim,
M. Auger,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
J. Cook
, et al. (55 additional authors not shown)
Abstract:
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute (SL…
▽ More
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute (SLPM) of xenon gas with 750 torr differential pressure.
△ Less
Submitted 26 April, 2011;
originally announced April 2011.
-
Gyrobunching and wave-particle resonance in the lower hybrid drift instability
Authors:
J W S Cook,
R O Dendy,
S C Chapman
Abstract:
We report a first principles study of the coupled evolution of energetic ions, background majority ions, electrons and electromagnetic fields in magnetised plasma during the linear phase of the lower hybrid drift instability. A particle-in-cell code, with one spatial and three velocity space co-ordinates, is used to analyse the evolving distribution of a drifting ring-beam population of energetic…
▽ More
We report a first principles study of the coupled evolution of energetic ions, background majority ions, electrons and electromagnetic fields in magnetised plasma during the linear phase of the lower hybrid drift instability. A particle-in-cell code, with one spatial and three velocity space co-ordinates, is used to analyse the evolving distribution of a drifting ring-beam population of energetic protons in physical space and gyrophase angle. This analysis is carried out for plasma parameters that approximate to edge conditions in large tokamaks, in a scenario that is motivated by observations of ion cyclotron emission and may be relevant to alpha channelling. Resonant energy transfer occurs at the two gyrophase angles at which the instantaneous speed of an energetic proton on its cyclotron orbit precisely matches the phase velocity of the lower hybrid wave along the simulation domain. Electron space-charge oscillations determine the wavelength of the propagating lower hybrid wave, and thereby govern the spatial distribution of gyrobunching of the energetic protons that drive the instability.
△ Less
Submitted 11 January, 2011;
originally announced January 2011.
-
Self-consistent kinetic simulations of lower hybrid drift instability resulting in electron current driven by fusion products in tokamak plasmas
Authors:
J W S Cook,
S C Chapman,
R O Dendy
Abstract:
We present particle-in-cell (PIC) simulations of minority energetic protons in deuterium plasmas, which demonstrate a collective instability responsible for emission near the lower hybrid frequency and its harmonics. The simulations capture the lower hybrid drift instability in a regime relevant to tokamak fusion plasmas, and show further that the excited electromagnetic fields collectively and co…
▽ More
We present particle-in-cell (PIC) simulations of minority energetic protons in deuterium plasmas, which demonstrate a collective instability responsible for emission near the lower hybrid frequency and its harmonics. The simulations capture the lower hybrid drift instability in a regime relevant to tokamak fusion plasmas, and show further that the excited electromagnetic fields collectively and collisionlessly couple free energy from the protons to directed electron motion. This results in an asymmetric tail antiparallel to the magnetic field. We focus on obliquely propagating modes under conditions approximating the outer mid-plane edge in a large tokamak, through which there pass confined centrally born fusion products on banana orbits that have large radial excursions. A fully self-consistent electromagnetic relativistic PIC code representing all vector field quantities and particle velocities in three dimensions as functions of a single spatial dimension is used to model this situation, by evolving the initial antiparallel travelling ring-beam distribution of 3MeV protons in a background 10keV Maxwellian deuterium plasma with realistic ion-electron mass ratio. The simulations thus demonstrate a key building block of alpha channelling scenarios for burning fusion plasmas in tokamaks.
△ Less
Submitted 11 October, 2010;
originally announced October 2010.
-
Electron current drive by fusion-product-excited lower hybrid drift instability
Authors:
J. W. S. Cook,
S. C. Chapman,
R. O. Dendy
Abstract:
We present first principles simulations of the direct collisionless coupling of the free energy of fusion-born ions into electron current in a magnetically confined fusion plasma. These simulations demonstrate, for the first time, a key building block of some "alpha channelling" scenarios for tokamak experiments. A fully self-consistent electromagnetic 1D3V particle-in-cell code is used to evolve…
▽ More
We present first principles simulations of the direct collisionless coupling of the free energy of fusion-born ions into electron current in a magnetically confined fusion plasma. These simulations demonstrate, for the first time, a key building block of some "alpha channelling" scenarios for tokamak experiments. A fully self-consistent electromagnetic 1D3V particle-in-cell code is used to evolve a parallel drifting ring-beam distribution of 3MeV protons in a 10keV thermal deuterium-electron plasma with realistic mass ratio. Collective instability gives rise to electromagnetic field activity in the lower hybrid range of frequencies. These spontaneously excited obliquely propagating waves undergo Landau damping on resonant electrons, drawing out an asymmetric tail in the distribution of electron parallel velocities, which carries a current.
△ Less
Submitted 6 September, 2010;
originally announced September 2010.
-
A simple radionuclide-driven single-ion source
Authors:
M. Montero Díez,
K. Twelker,
W. Fairbank Jr.,
G. Gratta,
P. S. Barbeau,
K. Barry,
R. DeVoe,
M. J. Dolinski,
M. Green,
F. LePort,
A. R. Müller,
R. Neilson,
K. O'Sullivan,
N. Ackerman,
B. Aharmin,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
S. Cook,
T. Daniels,
K. Donato,
J. Farine,
G. Giroux,
R. Gornea
, et al. (32 additional authors not shown)
Abstract:
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detect…
▽ More
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detection of an α particle in the substrate detector allows for tagging of the nuclear decay and of the Ba+ emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.
△ Less
Submitted 19 August, 2010;
originally announced August 2010.
-
Characterization of large area APDs for the EXO-200 detector
Authors:
R. Neilson,
F. LePort,
A. Pocar,
K. Kumar,
A. Odian,
C. Y. Prescott,
V. Tenev,
N. Ackerman,
D. Akimov,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
R. Conley,
S. Cook,
R. deVoe,
M. J. Dolinski,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger,
B. Flatt,
R. Gornea,
G. Gratta,
M. Green,
C. Hall
, et al. (27 additional authors not shown)
Abstract:
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more tha…
▽ More
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.
△ Less
Submitted 13 June, 2009;
originally announced June 2009.