Technical note: On the use of polychromatic cameras for high spatial resolution spectral dose measurements
Authors:
Emily Cloutier,
Luc Beaulieu,
Louis Archambault
Abstract:
Despite the demonstrated benefits of hyperspectral formalism for stem effect corrections in the context of fiber dose measurements, this approach has not been yet translated into volumetric measurements where cameras are typically used for their distinguishing spatial resolution. This work investigates demosaicing algorithms for polychromatic cameras based spectral imaging. The scintillation and C…
▽ More
Despite the demonstrated benefits of hyperspectral formalism for stem effect corrections in the context of fiber dose measurements, this approach has not been yet translated into volumetric measurements where cameras are typically used for their distinguishing spatial resolution. This work investigates demosaicing algorithms for polychromatic cameras based spectral imaging. The scintillation and Cherenkov signals produced in a radioluminescent phantom are imaged by a polychromatic camera and isolated using the spectral formalism. To do so, five demosaicing algorithms are investigated from calibration to measurements: a clustering method and four interpolation algorithms. The resulting accuracy of scintillation and Cherenkov images is evaluated with measurements of the differences (mean $\pm$ standard deviation) between the obtained and expected signals from profiles drawn across a scintillation spot. Signal-to-noise ratio and signal-to-background ratio are further measured and compared in the resulting scintillation images. Clustering, OpenCV, bilinear, Malvar and Menon demosaicing algorithms respectively yielded differences of $3\pm6\%$, $0.1\pm0.5\%$, $0.5\pm0.5\%$, $1\pm3\%$ and $1\pm4\%$ in the resulting scintillation images. For the Cherenkov images, all algorithms provided differences below 1\%. All methods enabled measurements over the detectability (SBR>2) and sensitivity (SNR>5) thresholds with the bilinear algorithm providing the best SNR value. Hence, radioluminescent signals can accurately be isolated using a single polychromatic camera. Moreover, demosaicing using a bilinear kernel provided the best results and enabled stem effect subtraction while preserving the full spatial resolution of the camera.
△ Less
Submitted 30 November, 2021;
originally announced December 2021.
-
Accurate Dose Measurements Using Cherenkov Polarization Imaging
Authors:
Emily Cloutier,
Louis Archambault,
Luc Beaulieu
Abstract:
Purpose: Cherenkov radiation carries the potential of direct in-water dose measurements, but its precision is currently limited by a strong anisotropy. Taking advantage of polarization imaging, this work proposes a new approach for high accuracy Cherenkov dose measurements. Methods: Cherenkov produced in a 15x15x20 cm^3 water tank is imaged with a cooled CCD camera from four polarizer transmission…
▽ More
Purpose: Cherenkov radiation carries the potential of direct in-water dose measurements, but its precision is currently limited by a strong anisotropy. Taking advantage of polarization imaging, this work proposes a new approach for high accuracy Cherenkov dose measurements. Methods: Cherenkov produced in a 15x15x20 cm^3 water tank is imaged with a cooled CCD camera from four polarizer transmission axes [0°, 45°, 90°, 135°]. The water tank is positioned at the isocenter of a 5x5 cm^2, 6 MV photon beam. Using Malus' law, the polarized portion of the signal is extracted. Corrections are applied to the polarized signal following azimuthal and polar Cherenkov angular distributions extracted from Monte Carlo simulations. Percent depth dose and beam profiles are measured and compared with the prediction from a treatment planning system (TPS). Results: Corrected polarized signals on the central axis reduced deviations at depth from 20% to 0.8\pm1%. For the profile measurement, differences between the corrected polarized signal and the TPS calculations are 1\pm3% and 8\pm3% on the central axis and penumbra regions respectively. 29\pm1% of the Cherenkov signal was found to be polarized. Conclusions: This work proposes a novel polarization imaging approach enabling high precision water-based Cherenkov dose measurements. The method allows correction of the Cherenkov anisotropy within 3% on the beam central axis and in depth.
△ Less
Submitted 15 June, 2021;
originally announced June 2021.
-
Deformable Scintillation Dosimeter II: Real-Time Simultaneous Measurements of Dose and Tracking of Deformation Vector Fields
Authors:
Emily Cloutier,
Luc Beaulieu,
Louis Archambault
Abstract:
Anatomical motion and deformation pose challenges to the understanding of the delivered dose distribution during radiotherapy treatments. Hence, deformable image registration (DIR) algorithms are increasingly used to map contours and dose distributions from one image set to another. However, the lack of validation tools slows their clinical adoption, despite their commercial availability. This wor…
▽ More
Anatomical motion and deformation pose challenges to the understanding of the delivered dose distribution during radiotherapy treatments. Hence, deformable image registration (DIR) algorithms are increasingly used to map contours and dose distributions from one image set to another. However, the lack of validation tools slows their clinical adoption, despite their commercial availability. This work presents a novel water-equivalent deformable dosimeter that simultaneously measures the dose distribution and tracks deformation vector fields (DVF). The dosimeter in made of an array of 19 scintillating fiber detectors embedded in a cylindrical elastomer matrix. It is imaged by two pairs of stereoscopic cameras tracking the position and angulation of the scintillators, while measuring the dose. The resulting system provides a precision of 0.3 mm on DVF measurements. The dosimeter was irradiated with 5$\times$3, 4$\times$3 and 3$\times$3 cm$^2$ 6 MV photon beams in both fixed and deformed conditions. The measured DVF was compared to the one computed with a DIR algorithm (Plastimatch). The deviations between the computed and measured DVFs was below 1.5 mm. As for dose measurements, the dosimeter acquired the dose distribution in fixed and deformed conditions within 1\% of the treatment planning system calculation and complementary dose validation using the Hyperscint dosimetry system. Using the demonstrated qualities of scintillating detectors, we developed a real-time, water-equivalent deformable dosimeter. Given it's sensor tracking position precision and dose measurements accuracy, the developed detector is a promising tools for the validation of DIR algorithms as well as dose distribution measurements under fixed and deformed conditions.
△ Less
Submitted 21 January, 2021;
originally announced January 2021.
-
Deformable Scintillation Dosimeter I: Challenges and Implementation using Computer Vision Techniques
Authors:
Emily Cloutier,
Louis Archambault,
Luc Beaulieu
Abstract:
Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional detectors, especially in complex irradiation geometries. Their range of applications could be further extended by embedding scintillators in a deformable matrix mimick…
▽ More
Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional detectors, especially in complex irradiation geometries. Their range of applications could be further extended by embedding scintillators in a deformable matrix mimicking anatomical changes. In this work, we characterized signal variations arising from the translation and rotation of scintillating fibers with respect to a camera. Corrections are proposed using stereo vision techniques and two sCMOS complementing a CCD camera. The study was extended to the case of a prototype real-time deformable dosimeter comprising an array of 19 scintillating. The signal to angle relationship follows a gaussian distribution (FWHM = 52°) whereas the intensity variation from radial displacement follows the inverse square law. Tracking the position and angle of the fibers enabled the correction of these spatial dependencies. The detecting system provides an accuracy and precision of respectively 0.008 cm and 0.03 cm on the position detection. This resulted in an uncertainty of 2° on the angle measurement. Displacing the dosimeter by $\pm$3 cm in depth resulted in relative intensities of 100$\pm$10% (mean $\pm$ standard deviation) to the reference position. Applying corrections reduced the variations thus resulting in relative intensities of 100$\pm$1%. Similarly, for lateral displacements of $\pm$3 cm, intensities went from 98$\pm$3% to 100$\pm$1% after the correction. Therefore, accurate correction of the signal collected by a camera imaging the output of scintillating elements in a 3D volume is possible. This work paves the way to the development of real-time scintillator-based deformable dosimeters.
△ Less
Submitted 21 January, 2021;
originally announced January 2021.