Design Initiative for a 10 TeV pCM Wakefield Collider
Authors:
Spencer Gessner,
Jens Osterhoff,
Carl A. Lindstrøm,
Kevin Cassou,
Simone Pagan Griso,
Jenny List,
Erik Adli,
Brian Foster,
John Palastro,
Elena Donegani,
Moses Chung,
Mikhail Polyanskiy,
Lindsey Gray,
Igor Pogorelsky,
Gongxiaohui Chen,
Gianluca Sarri,
Brian Beaudoin,
Ferdinand Willeke,
David Bruhwiler,
Joseph Grames,
Yuan Shi,
Robert Szafron,
Angira Rastogi,
Alexander Knetsch,
Xueying Lu
, et al. (176 additional authors not shown)
Abstract:
This document outlines a community-driven Design Study for a 10 TeV pCM Wakefield Accelerator Collider. The 2020 ESPP Report emphasized the need for Advanced Accelerator R\&D, and the 2023 P5 Report calls for the ``delivery of an end-to-end design concept, including cost scales, with self-consistent parameters throughout." This Design Study leverages recent experimental and theoretical progress re…
▽ More
This document outlines a community-driven Design Study for a 10 TeV pCM Wakefield Accelerator Collider. The 2020 ESPP Report emphasized the need for Advanced Accelerator R\&D, and the 2023 P5 Report calls for the ``delivery of an end-to-end design concept, including cost scales, with self-consistent parameters throughout." This Design Study leverages recent experimental and theoretical progress resulting from a global R\&D program in order to deliver a unified, 10 TeV Wakefield Collider concept. Wakefield Accelerators provide ultra-high accelerating gradients which enables an upgrade path that will extend the reach of Linear Colliders beyond the electroweak scale. Here, we describe the organization of the Design Study including timeline and deliverables, and we detail the requirements and challenges on the path to a 10 TeV Wakefield Collider.
△ Less
Submitted 31 March, 2025; v1 submitted 26 March, 2025;
originally announced March 2025.
-
Effect of Dielectric Wakefields in a Capillary Discharge for Plasma Wakefield Acceleration
Authors:
L. Verra,
M. Galletti,
R. Pompili,
A. Biagioni,
M. Carillo,
A. Cianchi,
L. Crincoli,
A. Curcio,
F. Demurtas,
G. Di Pirro,
V. Lollo,
G. Parise,
D. Pellegrini,
S. Romeo,
G. J. Silvi,
F. Villa,
M. Ferrario
Abstract:
Dielectric capillaries are widely used to generate plasmas for plasma wakefield acceleration. When a relativistic drive bunch travels through a capillary with misaligned trajectory with respect to the capillary axis, it is deflected by the effect of the dielectric transverse wakefields it drives. We experimentally show that the deflection effect increases along the bunch and with larger misalignme…
▽ More
Dielectric capillaries are widely used to generate plasmas for plasma wakefield acceleration. When a relativistic drive bunch travels through a capillary with misaligned trajectory with respect to the capillary axis, it is deflected by the effect of the dielectric transverse wakefields it drives. We experimentally show that the deflection effect increases along the bunch and with larger misalignment, and we investigate the decay of dielectric wakefields by measuring the effect on the front of a trailing bunch. We discuss the implications for the design of a plasma wakefield accelerator based on dielectric capillaries.
△ Less
Submitted 9 October, 2024;
originally announced October 2024.
-
Experimental Observation of Space-Charge Field Screening of a Relativistic Particle Bunch in Plasma
Authors:
L. Verra,
M. Galletti,
R. Pompili,
A. Biagioni,
M. Carillo,
A. Cianchi,
L. Crincoli,
A. Curcio,
F. Demurtas,
G. Di Pirro,
V. Lollo,
G. Parise,
D. Pellegrini,
S. Romeo,
G. J. Silvi,
F. Villa,
M. Ferrario
Abstract:
The space-charge field of a relativistic charged bunch propagating in plasma is screened due to the presence of mobile charge carriers. We experimentally investigate such screening by measuring the effect of dielectric wakefields driven by the bunch in a uncoated dielectric capillary where the plasma is confined. We show that the plasma screens the space-charge field and therefore suppresses the d…
▽ More
The space-charge field of a relativistic charged bunch propagating in plasma is screened due to the presence of mobile charge carriers. We experimentally investigate such screening by measuring the effect of dielectric wakefields driven by the bunch in a uncoated dielectric capillary where the plasma is confined. We show that the plasma screens the space-charge field and therefore suppresses the dielectric wakefields when the distance between the bunch and the dielectric surface is much larger than the plasma skin depth. Before full screening is reached, the effects of dielectric and plasma wakefields are present simultaneously.
△ Less
Submitted 17 June, 2024;
originally announced June 2024.
-
Lattice Boltzmann method for warm fluid simulations of plasma wakefield acceleration
Authors:
Daniele Simeoni,
Gianmarco Parise,
Fabio Guglietta,
Andrea Renato Rossi,
James Rosenzweig,
Alessandro Cianchi,
Mauro Sbragaglia
Abstract:
A comprehensive characterization of lattice Boltzmann (LB) schemes to perform warm fluid numerical simulations of particle wakefield acceleration (PWFA) processes is discussed in this paper. The LB schemes we develop hinge on the moment matching procedure, allowing the fluid description of a warm relativistic plasma wake generated by a driver pulse propagating in a neutral plasma. We focus on flui…
▽ More
A comprehensive characterization of lattice Boltzmann (LB) schemes to perform warm fluid numerical simulations of particle wakefield acceleration (PWFA) processes is discussed in this paper. The LB schemes we develop hinge on the moment matching procedure, allowing the fluid description of a warm relativistic plasma wake generated by a driver pulse propagating in a neutral plasma. We focus on fluid models equations resulting from two popular closure assumptions of the relativistic kinetic equations, i.e., the local equilibrium and the warm plasma closure assumptions. The developed LB schemes can thus be used to disclose insights on the quantitative differences between the two closure approaches in the dynamics of PWFA processes. Comparisons between the proposed schemes and available analytical results are extensively addressed.
△ Less
Submitted 16 February, 2024; v1 submitted 9 September, 2023;
originally announced September 2023.
-
Design, optimization and experimental characterization of RF injectors for high brightness electron beams and plasma acceleration
Authors:
V. Shpakov,
D. Alesini,
M. P. Anania,
M. Behtouei,
B. Buonomo,
M. Bellaveglia,
A. Biagioni,
F. Cardelli,
M. Carillo,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Del Giorno,
L. Faillace,
M. Ferrario,
M. del Franco,
G. Franzini,
M. Galletti,
L. Giannessi,
A. Giribono,
A. Liedl,
V. Lollo,
A. Mostacci,
G. Di Pirro,
L. Piersanti
, et al. (8 additional authors not shown)
Abstract:
In this article, we share our experience related to the new photo-injector commissioning at the SPARC\_LAB test facility. The new photo-injector was installed into an existing machine and our goal was not only to improve the final beam parameters themselves but to improve the machine handling in day-to-day operations as well. Thus, besides the pure beam characterization, this article contains info…
▽ More
In this article, we share our experience related to the new photo-injector commissioning at the SPARC\_LAB test facility. The new photo-injector was installed into an existing machine and our goal was not only to improve the final beam parameters themselves but to improve the machine handling in day-to-day operations as well. Thus, besides the pure beam characterization, this article contains information about the improvements, that were introduced into the new photo-injector design from the machine maintenance point of view, and the benefits, that we gained by using the new technique to assemble the gun itself.
△ Less
Submitted 12 December, 2022;
originally announced December 2022.
-
Lattice Boltzmann simulations of Plasma Wakefield Acceleration
Authors:
Gianmarco Parise,
Alessandro Cianchi,
Alessio Del Dotto,
Fabio Guglietta,
Andrea Renato Rossi,
Mauro Sbragaglia
Abstract:
We explore a novel simulation route for Plasma Wakefield Acceleration (PWFA) by using the computational method known as the Lattice Boltzmann Method (LBM). LBM is based on a discretization of the continuum kinetic theory while assuring the convergence towards hydrodynamics for coarse-grained fields (i.e., density, velocity, etc.). LBM is an established numerical analysis tool in computational flui…
▽ More
We explore a novel simulation route for Plasma Wakefield Acceleration (PWFA) by using the computational method known as the Lattice Boltzmann Method (LBM). LBM is based on a discretization of the continuum kinetic theory while assuring the convergence towards hydrodynamics for coarse-grained fields (i.e., density, velocity, etc.). LBM is an established numerical analysis tool in computational fluid dynamics, able to efficiently bridge between kinetic theory and hydrodynamics, but its application in the context of PWFA has never been investigated so far. This paper aims at filling this gap. Results of LBM simulations for PWFA are discussed and compared with those of a code (Architect) implementing a Cold Fluid (CF) model for the plasma. In the hydrodynamic framework, we discuss the importance of regularization effects related to diffusion properties intrinsic of the LBM, allowing to go beyond the traditional CF approximations. Issues on computational efficiency are also addressed.
△ Less
Submitted 14 January, 2022;
originally announced January 2022.
-
First emittance measurement of the beam-driven plasma wakefield accelerated electron beam
Authors:
V. Shpakov,
M. P. Anania,
M. Behtouei,
M. Bellaveglia,
A. Biagioni,
M. Cesarini,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Croia,
A. Del Dotto,
M. Diomede,
F. Dipace,
M. Ferrario,
M. Galletti,
A. Giribono,
A. Liedl,
V. Lollo,
L. Magnisi,
A. Mostacci,
G. Di Pirro,
L. Piersanti,
R. Pompili,
S. Romeo,
A. R. Rossi
, et al. (4 additional authors not shown)
Abstract:
Next-generation plasma-based accelerators can push electron beams to GeV energies within centimetre distances. The plasma, excited by a driver pulse, is indeed able to sustain huge electric fields that can efficiently accelerate a trailing witness bunch, which was experimentally demonstrated on multiple occasions. Thus, the main focus of the current research is being shifted towards achieving a hi…
▽ More
Next-generation plasma-based accelerators can push electron beams to GeV energies within centimetre distances. The plasma, excited by a driver pulse, is indeed able to sustain huge electric fields that can efficiently accelerate a trailing witness bunch, which was experimentally demonstrated on multiple occasions. Thus, the main focus of the current research is being shifted towards achieving a high quality of the beam after the plasma acceleration. In this letter we present beam-driven plasma wakefield acceleration experiment, where initially preformed high-quality witness beam was accelerated inside the plasma and characterized. In this experiment the witness beam quality after the acceleration was maintained on high level, with $0.2\%$ final energy spread and $3.8~μm$ resulting normalized transverse emittance after the acceleration. In this article, for the first time to our knowledge, the emittance of the PWFA beam was directly measured.
△ Less
Submitted 9 April, 2021;
originally announced April 2021.
-
Energy spread minimization in a beam-driven plasma wakefield accelerator
Authors:
R. Pompili,
M. P. Anania,
M. Behtouei,
M. Bellaveglia,
A. Biagioni,
F. G. Bisesto,
M. Cesarini,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Croia,
A. Del Dotto,
D. Di Giovenale,
M. Diomede,
F. Dipace,
M. Ferrario,
A. Giribono,
V. Lollo,
L. Magnisi,
M. Marongiu,
A. Mostacci,
G. Di Pirro,
S. Romeo,
A. R. Rossi,
J. Scifo
, et al. (4 additional authors not shown)
Abstract:
Next-generation plasma-based accelerators can push electron bunches to gigaelectronvolt energies within centimetre distances. The plasma, excited by a driver pulse, generates large electric fields that can efficiently accelerate a trailing witness bunch making possible the realization of laboratory-scale applications ranging from high-energy colliders to ultra-bright light sources. So far several…
▽ More
Next-generation plasma-based accelerators can push electron bunches to gigaelectronvolt energies within centimetre distances. The plasma, excited by a driver pulse, generates large electric fields that can efficiently accelerate a trailing witness bunch making possible the realization of laboratory-scale applications ranging from high-energy colliders to ultra-bright light sources. So far several experiments have demonstrated a significant acceleration but the resulting beam quality, especially the energy spread, is still far from state of the art conventional accelerators. Here we show the results of a beam-driven plasma acceleration experiment where we used an electron bunch as a driver followed by an ultra-short witness. The experiment demonstrates, for the first time, an innovative method to achieve an ultra-low energy spread of the accelerated witness of about 0.1%. This is an order of magnitude smaller than what has been obtained so far. The result can lead to a major breakthrough toward the optimization of the plasma acceleration process and its implementation in forthcoming compact machines for user-oriented applications.
△ Less
Submitted 2 June, 2020;
originally announced June 2020.
-
Diagnostic Needs for Wakefield Accelerator Experiments
Authors:
Alessandro Cianchi
Abstract:
Wakefield accelerators are under development in many laboratories worldwide. They bring the promise of a high accelerating gradient, orders of magnitude higher than current machines. The reduction in the overall length of the accelerators will pave the way to a wider use of such machines, for industrial, medical, research, and educational purposes. At the same time, all the equipment must be reduc…
▽ More
Wakefield accelerators are under development in many laboratories worldwide. They bring the promise of a high accelerating gradient, orders of magnitude higher than current machines. The reduction in the overall length of the accelerators will pave the way to a wider use of such machines, for industrial, medical, research, and educational purposes. At the same time, all the equipment must be reduced as well, to keep the dimensions of the machine as small as possible. The two main challenges of the diagnostics for plasma accelerated electron beams are the ability to measure the 6D phase space properties with single shot techniques and the compactness to meet the requirements of a `table-top' facility.
△ Less
Submitted 17 May, 2020;
originally announced May 2020.
-
Diagnostics Examples from lepton-linacs and FELs
Authors:
Alessandro Cianchi
Abstract:
There is a big gap between the charming principles ideas and the real implementation of a diagnostic. In this lecture we review some details that make the difference between a good and bad measurement, highlighting also the relation between the measured quantities and the real ones.
There is a big gap between the charming principles ideas and the real implementation of a diagnostic. In this lecture we review some details that make the difference between a good and bad measurement, highlighting also the relation between the measured quantities and the real ones.
△ Less
Submitted 15 May, 2020;
originally announced May 2020.
-
An Ultra-Compact X-Ray Free-Electron Laser
Authors:
J. B. Rosenzweig,
N. Majernik,
R. R. Robles,
G. Andonian,
O. Camacho,
A. Fukasawa,
A. Kogar,
G. Lawler,
Jianwei Miao,
P. Musumeci,
B. Naranjo,
Y. Sakai,
R. Candler,
B. Pound,
C. Pellegrini,
C. Emma,
A. Halavanau,
J. Hastings,
Z. Li,
M. Nasr,
S. Tantawi,
P. Anisimov,
B. Carlsten,
F. Krawczyk,
E. Simakov
, et al. (11 additional authors not shown)
Abstract:
In the field of beam physics, two frontier topics have taken center stage due to their potential to enable new approaches to discovery in a wide swath of science. These areas are: advanced, high gradient acceleration techniques, and x-ray free electron lasers (XFELs). Further, there is intense interest in the marriage of these two fields, with the goal of producing a very compact XFEL. In this con…
▽ More
In the field of beam physics, two frontier topics have taken center stage due to their potential to enable new approaches to discovery in a wide swath of science. These areas are: advanced, high gradient acceleration techniques, and x-ray free electron lasers (XFELs). Further, there is intense interest in the marriage of these two fields, with the goal of producing a very compact XFEL. In this context, recent advances in high gradient radio-frequency cryogenic copper structure research have opened the door to the use of surface electric fields between 250 and 500 MV/m. Such an approach is foreseen to enable a new generation of photoinjectors with six-dimensional beam brightness beyond the current state-of-the-art by well over an order of magnitude. This advance is an essential ingredient enabling an ultra-compact XFEL (UC-XFEL). In addition, one may accelerate these bright beams to GeV scale in less than 10 meters. Such an injector, when combined with inverse free electron laser-based bunching techniques can produce multi-kA beams with unprecedented beam quality, quantified by ~50 nm-rad normalized emittances. These beams, when injected into innovative, short-period (1-10 mm) undulators uniquely enable UC-XFELs having footprints consistent with university-scale laboratories. We describe the architecture and predicted performance of this novel light source, which promises photon production per pulse of a few percent of existing XFEL sources. We review implementation issues including collective beam effects, compact x-ray optics systems, and other relevant technical challenges. To illustrate the potential of such a light source to fundamentally change the current paradigm of XFELs with their limited access, we examine possible applications in biology, chemistry, materials, atomic physics, industry, and medicine which may profit from this new model of performing XFEL science.
△ Less
Submitted 14 August, 2020; v1 submitted 12 March, 2020;
originally announced March 2020.
-
Plasma lens-based beam extraction and removal system for Plasma Wakefield Acceleration experiments
Authors:
R. Pompili,
E. Chiadroni,
A. Cianchi,
A. Del Dotto,
L. Faillace,
M. Ferrario,
P. Iovine,
M. R. Masullo
Abstract:
Plasma Wakefield Acceleration represents one of the most promising techniques able to overcome the limits of conventional RF technology and make possible the development of compact accelerators. With respect to the laser-driven schemes, the beam-driven scenario is not limited by diffraction and dephasing issues, thus it allows to achieve larger acceleration lengths. One of the most prominent drawb…
▽ More
Plasma Wakefield Acceleration represents one of the most promising techniques able to overcome the limits of conventional RF technology and make possible the development of compact accelerators. With respect to the laser-driven schemes, the beam-driven scenario is not limited by diffraction and dephasing issues, thus it allows to achieve larger acceleration lengths. One of the most prominent drawback, conversely, occurs at the end of the acceleration process and consists of removing the depleted high-charge driver while preserving the main features (emittance and peak current) of the accelerated witness bunch. Here we present a theoretical study demonstrating the possibility to reach these goals by using an innovative system consisting of an array of beam collimators and discharge-capillaries operating as active-plasma lenses. Such a system allows to extract and transport the accelerated and highly divergent witness bunch and, at the same time, provides for the removal of the driver. The study is completed by a set of numerical simulations conducted for different beam configurations. The physics of the interaction of particles with collimator is also investigated.
△ Less
Submitted 6 September, 2019; v1 submitted 3 September, 2019;
originally announced September 2019.
-
Longitudinal phase-space manipulation with beam-driven plasma wakefields
Authors:
V. Shpakov,
M. P. Anania,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
F. Cardelli,
M. Cesarini,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Croia,
A. DelDotto,
D. DiGiovenale,
M. Diomede,
M. Ferrario,
F. Filippi,
A. Giribono,
V. Lollo,
M. Marongiu,
V. Martinelli,
A. Mostacci,
L. Piersanti,
G. DiPirro,
R. Pompili,
S. Romeo
, et al. (4 additional authors not shown)
Abstract:
The development of compact accelerator facilities providing high-brightness beams is one of the most challenging tasks in field of next-generation compact and cost affordable particle accelerators, to be used in many fields for industrial, medical and research applications. The ability to shape the beam longitudinal phase-space, in particular, plays a key role to achieve high-peak brightness. Here…
▽ More
The development of compact accelerator facilities providing high-brightness beams is one of the most challenging tasks in field of next-generation compact and cost affordable particle accelerators, to be used in many fields for industrial, medical and research applications. The ability to shape the beam longitudinal phase-space, in particular, plays a key role to achieve high-peak brightness. Here we present a new approach that allows to tune the longitudinal phase-space of a high-brightness beam by means of a plasma wakefields. The electron beam passing through the plasma drives large wakefields that are used to manipulate the time-energy correlation of particles along the beam itself. We experimentally demonstrate that such solution is highly tunable by simply adjusting the density of the plasma and can be used to imprint or remove any correlation onto the beam. This is a fundamental requirement when dealing with largely time-energy correlated beams coming from future plasma accelerators.
△ Less
Submitted 21 February, 2019;
originally announced February 2019.
-
Evolution of the electric fields induced in high intensity laser-matter interactions
Authors:
F. G. Bisesto,
M. P. Anania,
M. Botton,
E. Chiadroni,
A. Cianchi,
A. Curcio,
M. Ferrario,
M. Galletti,
Z. Henis,
R. Pompili,
E. Schleifer,
A. Zigler
Abstract:
Multi MeV protons \cite{snavely2000intense} and heavier ions are emitted by thin foils irradiated by high-intensity lasers, due to the huge accelerating fields, up to several teraelectronvolt per meter, at sub-picosecond timescale \cite{dubois2014target}. The evolution of these huge fields is not well understood till today. Here we report, for the first time, direct and temporally resolved measure…
▽ More
Multi MeV protons \cite{snavely2000intense} and heavier ions are emitted by thin foils irradiated by high-intensity lasers, due to the huge accelerating fields, up to several teraelectronvolt per meter, at sub-picosecond timescale \cite{dubois2014target}. The evolution of these huge fields is not well understood till today. Here we report, for the first time, direct and temporally resolved measurements of the electric fields produced by the interaction of a short-pulse high-intensity laser with solid targets. The results, obtained with a sub-$100$ fs temporal diagnostics, show that such fields build-up in few hundreds of femtoseconds and lasts after several picoseconds.
△ Less
Submitted 12 March, 2018;
originally announced March 2018.
-
Plasma ramps caused by outflow in gas-filled capillaries
Authors:
F. Filippi,
M. P. Anania,
A. Biagioni,
E. Brentegani,
E. Chiadroni,
A. Cianchi,
M. Ferrario,
A. Marocchino,
A. Zigler
Abstract:
Plasma confinement inside capillaries has been developed in the past years for plasma-based acceleration to ensure a stable and repeatable plasma density distribution during the interaction with either particles or laser beams. In particular, gas-filled capillaries allow a stable and almost predictable plasma distribution along the interaction with the particles. However, the plasma ejected throug…
▽ More
Plasma confinement inside capillaries has been developed in the past years for plasma-based acceleration to ensure a stable and repeatable plasma density distribution during the interaction with either particles or laser beams. In particular, gas-filled capillaries allow a stable and almost predictable plasma distribution along the interaction with the particles. However, the plasma ejected through the ends of the capillary interacts with the beam before the inner plasma, affecting the quality of the beam. In this article we report the measurements on the evolution of the plasma flow at the two ends of a 1 cm long, 1 mm diameter capillary filled with hydrogen. In particular, we measured the longitudinal density distribution and the expansion velocity of the plasma outside the capillary. This study will allow a better understanding of the beam-plasma interaction for future plasma-based experiments.
△ Less
Submitted 27 February, 2018;
originally announced February 2018.
-
EuPRAXIA@SPARC_LAB: the high-brightness RF photo-injector layout proposal
Authors:
A. Giribono,
A. Bacci,
E. Chiadroni,
A. Cianchi,
M. Croia,
M. Ferrario,
A. Marocchino,
V. Petrillo,
R. Pompili,
S. Romeo,
M. Rossetti Conti,
A. R. Rossi,
C. Vaccarezza
Abstract:
At EuPRAXIA@SPARC_LAB, the unique combination of an advanced high-brightness RF injector and a plasma-based accelerator will drive a new multi-disciplinary user-facility. The facility, that is currently under study at INFN-LNF Laboratories (Frascati, Italy) in synergy with the EuPRAXIA collaboration, will operate the plasma-based accelerator in the external injection configuration. Since in this c…
▽ More
At EuPRAXIA@SPARC_LAB, the unique combination of an advanced high-brightness RF injector and a plasma-based accelerator will drive a new multi-disciplinary user-facility. The facility, that is currently under study at INFN-LNF Laboratories (Frascati, Italy) in synergy with the EuPRAXIA collaboration, will operate the plasma-based accelerator in the external injection configuration. Since in this configuration the stability and reproducibility of the acceleration process in the plasma stage is strongly influenced by the RF-generated electron beam, the main challenge for the RF injector design is related to generating and handling high quality electron beams. In the last decades of R&D activity, the crucial role of high-brightness RF photo-injectors in the fields of radiation generation and advanced acceleration schemes has been largely established, making them effective candidates to drive plasma-based accelerators as pilots for user facilities. An RF injector consisting in a high-brightness S-band photo-injector followed by an advanced X-band linac has been proposed for the EuPRAXIA@SPARC_LAB project. The electron beam dynamics in the photo-injector has been explored by means of simulations, resulting in high-brightness, ultra-short bunches with up to 3 kA peak current at the entrance of the advanced X-band linac booster. The EuPRAXIA@SPARC_LAB high-brightness photo-injector is described here together with performance optimisation and sensitivity studies aiming to actual check the robustness and reliability of the desired working point.
△ Less
Submitted 25 February, 2018;
originally announced February 2018.
-
Plasma boosted electron beams for driving Free Electron Lasers
Authors:
A. R. Rossi,
V. Petrillo,
A. Bacci,
E. Chiadroni,
A. Cianchi,
M. Ferrario,
A. Giribono,
A. Marocchino,
M. Rossetti Conti,
L. Serafini,
C. Vaccarezza
Abstract:
In this paper, we report results of simulations, in the framework of both EuPRAXIA \cite{Walk2017} and EuPRAXIA@SPARC\_LAB \cite{Ferr2017} projects, aimed at delivering a high brightness electron bunch for driving a Free Electron Laser (FEL) by employing a plasma post acceleration scheme. The boosting plasma wave is driven by a tens of \SI{}{\tera\watt} class laser and doubles the energy of an ext…
▽ More
In this paper, we report results of simulations, in the framework of both EuPRAXIA \cite{Walk2017} and EuPRAXIA@SPARC\_LAB \cite{Ferr2017} projects, aimed at delivering a high brightness electron bunch for driving a Free Electron Laser (FEL) by employing a plasma post acceleration scheme. The boosting plasma wave is driven by a tens of \SI{}{\tera\watt} class laser and doubles the energy of an externally injected beam up to \GeV{1}. The injected bunch is simulated starting from a photoinjector, matched to plasma, boosted and finally matched to an undulator, where its ability to produce FEL radiation is verified to yield $O(\num{e11})$ photons per shot at \nm{2.7}.
△ Less
Submitted 19 February, 2018;
originally announced February 2018.
-
Design study of a photon beamline for a soft X-ray FEL driven by high gradient acceleration at EuPRAXIA@SPARC_LAB
Authors:
Fabio Villa,
Alessandro Cianchi,
Marcello Coreno,
Sultan Dabagov,
Augusto Marcelli,
Velia Minicozzi,
Silvia Morante,
Francesco Stellato
Abstract:
We are proposing a facility based on high gradient acceleration via x-band RF structures and plasma acceleration. We plan to reach an electron energy of the order of 1 GeV, suitable to drive a Free Electron Laser for applications in the so called "water window" (2 - 4 nm). A conceptual design of the beamline, from the photon beam from the undulators to the user experimental chamber, mainly focusin…
▽ More
We are proposing a facility based on high gradient acceleration via x-band RF structures and plasma acceleration. We plan to reach an electron energy of the order of 1 GeV, suitable to drive a Free Electron Laser for applications in the so called "water window" (2 - 4 nm). A conceptual design of the beamline, from the photon beam from the undulators to the user experimental chamber, mainly focusing on diagnostic, manipulation and transport of the radiation is presented and discussed. We also briefly outline a user end station for coherent imaging, laser ablation and pump-probe experiments.
△ Less
Submitted 15 February, 2018;
originally announced February 2018.
-
Conceptual design of electron beam diagnostics for high brightness plasma accelerator
Authors:
A. Cianchi,
D. Alesini,
M. P. Anania,
F. Biagioni,
F. Bisesto,
E. Chiadroni,
A. Curcio,
M. Ferrario,
F. Filippi,
A. Ghigo,
A. Giribono,
V. Lollo,
A. Mostacci,
R. Pompili,
L. Sabbatini,
V. Shpakov,
A. Stella,
C. Vaccarezza,
A. Vannozzi,
F. Villa
Abstract:
A design study of the diagnostics of a high brightness linac, based on X-band structures, and a plasma accelerator stage, has been delivered in the framework of the EuPRAXIA@SPARC_LAB project. In this paper, we present a conceptual design of the proposed diagnostics, using state of the art systems and new and under development devices. Single shot measurements are preferable for plasma accelerated…
▽ More
A design study of the diagnostics of a high brightness linac, based on X-band structures, and a plasma accelerator stage, has been delivered in the framework of the EuPRAXIA@SPARC_LAB project. In this paper, we present a conceptual design of the proposed diagnostics, using state of the art systems and new and under development devices. Single shot measurements are preferable for plasma accelerated beams, including emittance, while $μ$m level and fs scale beam size and bunch length respectively are requested. The needed to separate the driver pulse (both laser or beam) from the witness accelerated bunch imposes additional constrains for the diagnostics. We plan to use betatron radiation for the emittance measurement just at the end of the plasma booster, while other single-shot methods must be proven before to be implemented. Longitudinal measurements, being in any case not trivial for the fs level bunch length, seem to have already a wider range of possibilities.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
Energy Measurements by Means of Transition Radiation in novel Linacs
Authors:
M. Marongiu,
M. Castellano,
E. Chiadroni,
A. Cianchi,
G. Franzini,
A. Giribono,
A. Mostacci,
L. Palumbo,
V. Shpakov,
A. Stella,
A. Variola
Abstract:
Advanced linear accelerator design may use Optical Transition Radiation (OTR) screens to measure beam spot size; for instance, such screens are foreseen in plasma based accelerators (EuPRAXIA@SPARC_LAB) or Compton machines (Gamma Beam Source@ELI-NP). Optical Transition Radiation angular distribution strongly depends on beam energy. Since OTR screens are typically placed in several positions along…
▽ More
Advanced linear accelerator design may use Optical Transition Radiation (OTR) screens to measure beam spot size; for instance, such screens are foreseen in plasma based accelerators (EuPRAXIA@SPARC_LAB) or Compton machines (Gamma Beam Source@ELI-NP). Optical Transition Radiation angular distribution strongly depends on beam energy. Since OTR screens are typically placed in several positions along the Linac to monitor the beam envelope, one may perform a distributed energy measurement along the machine. Furthermore, a single shot energy measurement can be useful in plasma accelerators to measure shot to shot energy variations after the plasma interaction. Preliminary measurements of OTR angular distribution of about 100 MeV electrons have been performed at the SPARC_LAB facility. In this paper, we discuss the sensitivity of this measurement to beam divergence and others parameters, as well as the resolution required and the needed upgrades of conventional OTR diagnostics, using as an example the data collected at SPARC_LAB.
△ Less
Submitted 12 February, 2018;
originally announced February 2018.
-
Recent studies on single-shot diagnostics for plasma accelerators at SPARC_LAB
Authors:
F. G. Bisesto,
M. P. Anania,
M. Botton,
M. Castellano,
E. Chiadroni,
A. Cianchi,
A. Curcio,
M. Ferrario,
M. Galletti,
Z. Henis,
R. Pompili,
E. Schleifer,
V. Shpakov,
A. Zigler
Abstract:
Plasma wakefield acceleration is the most promising acceleration technique for compact and cheap accelerators, thanks to the high accelerating gradients achievable. Nevertheless, this approach still suffers of shot-to-shot instabilities, mostly related to experimental parameters fluctuations. Therefore, the use of single shot diagnostics is needed to properly understand the acceleration mechanism.…
▽ More
Plasma wakefield acceleration is the most promising acceleration technique for compact and cheap accelerators, thanks to the high accelerating gradients achievable. Nevertheless, this approach still suffers of shot-to-shot instabilities, mostly related to experimental parameters fluctuations. Therefore, the use of single shot diagnostics is needed to properly understand the acceleration mechanism. In this work, we present two diagnostics to probe electron beams from laser-plasma interactions, one relying on Electro Optical Sampling (EOS) for laser-solid matter interactions, the other one based on Optical Transition Radiation (OTR) for single shot measurements of the transverse emittance of plasma accelerated electron beams, both developed at the SPARC_LAB Test Facility.
△ Less
Submitted 9 February, 2018;
originally announced February 2018.
-
Characterization of self-injected electron beams from LWFA experiments at SPARC_LAB
Authors:
G. Costa,
M. P. Anania,
F. Bisesto,
E. Chiadroni,
A. Cianchi,
A. Curcio,
M. Ferrario,
F. Filippi,
A. Marocchino,
F. Mira,
R. Pompili,
A. Zigler
Abstract:
The plasma-based acceleration is an encouraging technique to overcome the limits of the accelerating gradient in the conventional RF acceleration. A plasma accelerator is able to provide accelerating fields up to hundreds of $GeV/m$, paving the way to accelerate particles to several MeV over a short distance (below the millimetre range). Here the characteristics of preliminary electron beams obtai…
▽ More
The plasma-based acceleration is an encouraging technique to overcome the limits of the accelerating gradient in the conventional RF acceleration. A plasma accelerator is able to provide accelerating fields up to hundreds of $GeV/m$, paving the way to accelerate particles to several MeV over a short distance (below the millimetre range). Here the characteristics of preliminary electron beams obtained with the self-injection mechanism produced with the FLAME high-power laser at the SPARC_LAB test facility are shown. In detail, with an energy laser on focus of $1.5\ J$ and a pulse temporal length (FWHM) of $40\ fs$, we obtained an electron plasma density due to laser ionization of about $6 \times 10^{18}\ cm^{-3}$, electron energy up to $350\ MeV$ and beam charge in the range $(50 - 100)\ pC$.
△ Less
Submitted 3 February, 2018;
originally announced February 2018.
-
The FLAME laser at SPARC_LAB
Authors:
F. G. Bisesto,
M. P. Anania,
M. Bellaveglia,
E. Chiadroni,
A. Cianchi,
G. Costa,
A. Curcio,
D. Di Giovenale,
G. Di Pirro,
M. Ferrario,
F. Filippi,
A. Gallo,
A. Marocchino,
R. Pompili,
A. Zigler,
C. Vaccarezza
Abstract:
FLAME is a high power laser system installed at the SPARC_LAB Test Facility in Frascati (Italy). The ultra-intense laser pulses are employed to study the interaction with matter for many purposes: electron acceleration through LWFA, ion and proton generation exploiting the TNSA mechanism, study of new radiation sources and development of new electron diagnostics. In this work, an overview of the F…
▽ More
FLAME is a high power laser system installed at the SPARC_LAB Test Facility in Frascati (Italy). The ultra-intense laser pulses are employed to study the interaction with matter for many purposes: electron acceleration through LWFA, ion and proton generation exploiting the TNSA mechanism, study of new radiation sources and development of new electron diagnostics. In this work, an overview of the FLAME laser system will be given, together with recent experimental results
△ Less
Submitted 1 February, 2018;
originally announced February 2018.
-
Overview of Plasma Lens Experiments and Recent Results at SPARC_LAB
Authors:
E. Chiadroni,
M. P. Anania,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
E. Brentegani,
F. Cardelli,
A. Cianchi,
G. Costa,
D. Di Giovenale,
G. Di Pirro,
M. Ferrario,
F. Filippi,
A. Gallo,
A. Giribono,
A. Marocchino,
A. Mostacci,
L. Piersanti,
R. Pompili,
J. B. Rosenzweig,
A. R. Rossi,
J. Scifo,
V. Shpakov,
C. Vaccarezza,
F. Villa
, et al. (1 additional authors not shown)
Abstract:
Beam injection and extraction from a plasma module is still one of the crucial aspects to solve in order to produce high quality electron beams with a plasma accelerator. Proper matching conditions require to focus the incoming high brightness beam down to few microns size and to capture a high divergent beam at the exit without loss of beam quality. Plasma-based lenses have proven to provide focu…
▽ More
Beam injection and extraction from a plasma module is still one of the crucial aspects to solve in order to produce high quality electron beams with a plasma accelerator. Proper matching conditions require to focus the incoming high brightness beam down to few microns size and to capture a high divergent beam at the exit without loss of beam quality. Plasma-based lenses have proven to provide focusing gradients of the order of kT/m with radially symmetric focusing thus promising compact and affordable alternative to permanent magnets in the design of transport lines. In this paper an overview of recent experiments and future perspectives of plasma lenses is reported.
△ Less
Submitted 1 February, 2018;
originally announced February 2018.
-
EUPRAXIA@SPARC_LAB: Beam Dynamics studies for the X-band Linac
Authors:
C. Vaccarezza,
D. Alesini,
A. Bacci,
A. Cianchi,
E. Chiadroni,
M. Croia,
M. Diomede,
M. Ferrario,
A. Gallo,
A. Giribono,
A. Latina,
A. Marocchino,
V. Petrillo,
R. Pompili,
S. Romeo,
M. Rossetti Conti,
A. R. Rossi,
L. Serafini,
B. Spataro
Abstract:
In the framework of the Eupraxia Design Study an advanced accelerator facility EUPRAXIA@SPARC_LAB has been proposed to be realized at Frascati (Italy) Laboratories of INFN. Two advanced acceleration schemes will be applied, namely an ultimate high gradient 1 GeV X-band linac together with a plasma acceleration stage to provide accelerating gradients of the GeV/m order. A FEL scheme is foreseen to…
▽ More
In the framework of the Eupraxia Design Study an advanced accelerator facility EUPRAXIA@SPARC_LAB has been proposed to be realized at Frascati (Italy) Laboratories of INFN. Two advanced acceleration schemes will be applied, namely an ultimate high gradient 1 GeV X-band linac together with a plasma acceleration stage to provide accelerating gradients of the GeV/m order. A FEL scheme is foreseen to produce X-ray beams within 3-10 nm range. A 500-TW Laser system is also foreseen for electron and ion production experiments and a Compton backscattering Interaction is planned together with extraction beamlines at intermediate electron beam energy for neutron beams and THz radiation production. The electron beam dynamics studies in the linac are here presented together with the preliminary machine layout.
△ Less
Submitted 30 January, 2018;
originally announced January 2018.
-
EuPRAXIA@SPARC_LAB Design study towards a compact FEL facility at LNF
Authors:
M. Ferrario,
D. Alesini,
M. P. Anania,
M. Artioli,
A. Bacci,
S. Bartocci,
R. Bedogni,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
F. Brandi,
E. Brentegani,
F. Broggi,
B. Buonomo,
P. L. Campana,
G. Campogiani,
C. Cannaos,
S. Cantarella,
F. Cardelli,
M. Carpanese,
M. Castellano,
G. Castorina,
N. Catalan Lasheras,
E. Chiadroni,
A. Cianchi
, et al. (95 additional authors not shown)
Abstract:
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in…
▽ More
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in synergy with the EuPRAXIA design study. In this paper we report about the recent progresses in the on going design study of the new facility.
△ Less
Submitted 26 January, 2018;
originally announced January 2018.
-
Recent results at SPARC_LAB
Authors:
R. Pompili,
M. P. Anania,
M. Bellaveglia,
A. Biagioni,
S. Bini,
F. Bisesto,
E. Chiadroni,
A. Cianchi,
G. Costa,
D. Di Giovenale,
M. Ferrario,
F. Filippi,
A. Gallo,
A. Giribono,
V. Lollo,
A. Marocchino,
V. Martinelli,
A. Mostacci,
G. Di Pirro,
S. Romeo,
J. Scifo,
V. Shpakov,
C. Vaccarezza,
F. Villa,
A. Zigler
Abstract:
The current activity of the SPARC_LAB test-facility is focused on the realization of plasma-based acceleration experiments with the aim to provide accelerating field of the order of several GV/m while maintaining the overall quality (in terms of energy spread and emittance) of the accelerated electron bunch. In the following, the current status of such an activity is presented. We also show result…
▽ More
The current activity of the SPARC_LAB test-facility is focused on the realization of plasma-based acceleration experiments with the aim to provide accelerating field of the order of several GV/m while maintaining the overall quality (in terms of energy spread and emittance) of the accelerated electron bunch. In the following, the current status of such an activity is presented. We also show results related to the usability of plasmas as focusing lenses in view of a complete plasma-based focusing and accelerating system.
△ Less
Submitted 18 January, 2018;
originally announced January 2018.
-
Wake fields effects in dielectric capillary
Authors:
A. Biagioni,
M. P. Anania,
M. Bellaveglia,
E. Brentegani,
G. Castorina,
E. Chiadroni,
A. Cianchi,
D. Di Giovenale,
G. Di Pirro,
H. Fares,
L. Ficcadenti,
F. Filippi,
M. Ferrario,
A. Mostacci,
R. Pompili,
J. Scifo,
B. Spataro,
C. Vaccarezza,
F. Villa,
A. Zigler
Abstract:
Plasma wake-field acceleration experiments are performed at the SPARC LAB test facility by using a gas-filled capillary plasma source composed of a dielectric capillary. The electron can reach GeV energy in a few centimeters, with an accelerating gradient orders of magnitude larger than provided by conventional techniques. In this acceleration scheme, wake fields produced by passing electron beams…
▽ More
Plasma wake-field acceleration experiments are performed at the SPARC LAB test facility by using a gas-filled capillary plasma source composed of a dielectric capillary. The electron can reach GeV energy in a few centimeters, with an accelerating gradient orders of magnitude larger than provided by conventional techniques. In this acceleration scheme, wake fields produced by passing electron beams through dielectric structures can determine a strong beam instability that represents an important hurdle towards the capability to focus high-current electron beams in the transverse plane. For these reasons, the estimation of the transverse wakefield amplitudes assumes a fundamental role in the implementation of the plasma wake-field acceleration. In this work, it presented a study to investigate which parameters affect the wake-field formation inside a cylindrical dielectric structure, both the capillary dimensions and the beam parameters, and it is introduced a quantitative evaluation of the longitudinal and transverse electric fields.
△ Less
Submitted 12 January, 2018;
originally announced January 2018.
-
A complementary compact laser based neutron source
Authors:
Alessandro Cianchi,
Carla Andreani,
Roberto Bedogni,
Giulia Festa,
Oriol Sans-Planell,
Roberto Senesi
Abstract:
Several experiments of neutron generation using high intensity laser sources, with a power exceeding 10^19W/cm^2 via TNSA (Target Normal Sheath Acceleration) or other similar methods, have been performed in the past years in different laboratories. However, so far there is no one running neutron source based on such a technology. In the framework of the Conceptual Report Design of a new accelerato…
▽ More
Several experiments of neutron generation using high intensity laser sources, with a power exceeding 10^19W/cm^2 via TNSA (Target Normal Sheath Acceleration) or other similar methods, have been performed in the past years in different laboratories. However, so far there is no one running neutron source based on such a technology. In the framework of the Conceptual Report Design of a new accelerator in the Eupraxia project we are studying the possibility to have a laser-based neutron source, not only by TNSA but also from self-injection schemes. We focus our attention on the applications in cultural heritage studies as well also on the complementary role that such a source can have in the framework of large facilities devoted to radiation production.
△ Less
Submitted 11 January, 2018;
originally announced January 2018.
-
Nano-machining, surface analysis and emittance measurements of a copper photocathode at SPARC_LAB
Authors:
J. Scifo,
D. Alesini,
M. P. Anania,
M. Bellaveglia,
S. Bellucci,
A. Biagioni,
F. Bisesto,
F. Cardelli,
E. Chiadroni,
A. Cianchi,
G. Costa,
D. Di Giovenale,
G. Di Pirro,
R. Di Raddo,
D. H. Dowell,
M. Ferrario,
A. Giribono,
A. Lorusso,
F. Micciulla,
A. Mostacci,
D. Passeri,
A. Perrone,
L. Piersanti,
R. Pompili,
V. Shpakov
, et al. (3 additional authors not shown)
Abstract:
R\&D activity on Cu photocathodes is under development at the SPARC\_LAB test facility to fully characterize each stage of the photocathode "life" and to have a complete overview of the photoemission properties in high brightness photo-injectors. The nano(n)-machining process presented here consists in diamond milling, and blowing with dry nitrogen. This procedure reduces the roughness of the cath…
▽ More
R\&D activity on Cu photocathodes is under development at the SPARC\_LAB test facility to fully characterize each stage of the photocathode "life" and to have a complete overview of the photoemission properties in high brightness photo-injectors. The nano(n)-machining process presented here consists in diamond milling, and blowing with dry nitrogen. This procedure reduces the roughness of the cathode surface and prevents surface contamination introduced by other techniques, such as polishing with diamond paste or the machining with oil. Both high roughness and surface contamination cause an increase of intrinsic emittance and consequently a reduction of the overall electron beam brightness. To quantify these effects, we have characterized the photocathode surface in terms of roughness measurement, and morphology and chemical composition analysis by means of Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), and Atomic Force Microscopy (AFM) techniques. The effects of n-machining on the electron beam quality have been also investigated through emittance measurements before and after the surface processing technique. Finally, we present preliminary emittance studies of yttrium thin film on Cu photocathodes.
△ Less
Submitted 11 January, 2018;
originally announced January 2018.
-
RF injector design studies for the trailing witness bunch for a plasma-based user facility
Authors:
A. Giribono,
A. Bacci,
E. Chiadroni,
A. Cianchi,
M. Croia,
M. Ferrario,
A. Marocchino,
V. Petrillo,
R. Pompili,
S. Romeo,
M. Rossetti Conti,
A. R. Rossi,
C. Vaccarezza
Abstract:
The interest in plasma-based accelerators as drivers of user facilities is growing worldwide thanks to its compactness and reduced costs. In this context the EuPRAXIA collaboration is preparing a conceptual design report for a multi-GeV plasma-based accelerator with outstanding electron beam quality to pilot, among several applications, the operation of an X-ray FEL, the most demanding in terms of…
▽ More
The interest in plasma-based accelerators as drivers of user facilities is growing worldwide thanks to its compactness and reduced costs. In this context the EuPRAXIA collaboration is preparing a conceptual design report for a multi-GeV plasma-based accelerator with outstanding electron beam quality to pilot, among several applications, the operation of an X-ray FEL, the most demanding in terms of beam brightness. Intense beam dynamics studies have been performed to provide a reliable working point for the RF injector to generate a high-brightness trailing witness bunch suitable in external injection schemes, both in particle beam and laser driven plasma wakefield acceleration. A case of interest is the generation of a witness beam with 1 GeV energy, less than 1 mm-mrad slice emittance and 30 pC in 10 fs FWHM bunch length, which turns into 3 kA peak current at the undulator entrance. The witness beam has been successfully compressed down to 10 fs in a conventional SPARC-like photo-injector and boosted up to 500 MeV in an advanced high-gradient X-band linac reaching the plasma entrance with 3 kA peak current and the following RMS values: 0.06% energy spread, 0.5 mm-mrad transverse normalised emittance and a focal spot down to 1 $μm$. RF injector studies are here presented with the aim to satisfy the EuPRAXIA requests for the Design Study of a plasma-based user facility.
△ Less
Submitted 16 January, 2018; v1 submitted 9 January, 2018;
originally announced January 2018.
-
Technical Design Report EuroGammaS proposal for the ELI-NP Gamma beam System
Authors:
O. Adriani,
S. Albergo,
D. Alesini,
M. Anania,
D. Angal-Kalinin,
P. Antici,
A. Bacci,
R. Bedogni,
M. Bellaveglia,
C. Biscari,
N. Bliss,
R. Boni,
M. Boscolo,
F. Broggi,
P. Cardarelli,
K. Cassou,
M. Castellano,
L. Catani,
I. Chaikovska,
E. Chiadroni,
R. Chiche,
A. Cianchi,
J. Clarke,
A. Clozza,
M. Coppola
, et al. (84 additional authors not shown)
Abstract:
The machine described in this document is an advanced Source of up to 20 MeV Gamma Rays based on Compton back-scattering, i.e. collision of an intense high power laser beam and a high brightness electron beam with maximum kinetic energy of about 720 MeV. Fully equipped with collimation and characterization systems, in order to generate, form and fully measure the physical characteristics of the pr…
▽ More
The machine described in this document is an advanced Source of up to 20 MeV Gamma Rays based on Compton back-scattering, i.e. collision of an intense high power laser beam and a high brightness electron beam with maximum kinetic energy of about 720 MeV. Fully equipped with collimation and characterization systems, in order to generate, form and fully measure the physical characteristics of the produced Gamma Ray beam. The quality, i.e. phase space density, of the two colliding beams will be such that the emitted Gamma ray beam is characterized by energy tunability, spectral density, bandwidth, polarization, divergence and brilliance compatible with the requested performances of the ELI-NP user facility, to be built in Romania as the Nuclear Physics oriented Pillar of the European Extreme Light Infrastructure. This document illustrates the Technical Design finally produced by the EuroGammaS Collaboration, after a thorough investigation of the machine expected performances within the constraints imposed by the ELI-NP tender for the Gamma Beam System (ELI-NP-GBS), in terms of available budget, deadlines for machine completion and performance achievement, compatibility with lay-out and characteristics of the planned civil engineering.
△ Less
Submitted 14 July, 2014;
originally announced July 2014.
-
IRIDE White Book, An Interdisciplinary Research Infrastructure based on Dual Electron linacs&lasers
Authors:
D. Alesini,
M. Alessandroni,
M. P. Anania,
S. Andreas,
M. Angelone,
A. Arcovito,
F. Arnesano,
M. Artioli,
L. Avaldi,
D. Babusci,
A. Bacci,
A. Balerna,
S. Bartalucci,
R. Bedogni,
M. Bellaveglia,
F. Bencivenga,
M. Benfatto,
S. Biedron,
V. Bocci,
M. Bolognesi,
P. Bolognesi,
R. Boni,
R. Bonifacio,
M. Boscolo,
F. Boscherini
, et al. (189 additional authors not shown)
Abstract:
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high ener…
▽ More
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high energy lasers. Conceived to provide unique research possibilities for particle physics, for condensed matter physics, chemistry and material science, for structural biology and industrial applications, IRIDE will open completely new research possibilities and advance our knowledge in many branches of science and technology. IRIDE will contribute to open new avenues of discoveries and to address most important riddles: What does matter consist of? What is the structure of proteins that have a fundamental role in life processes? What can we learn from protein structure to improve the treatment of diseases and to design more efficient drugs? But also how does an electronic chip behave under the effect of radiations? How can the heat flow in a large heat exchanger be optimized? The scientific potential of IRIDE is far reaching and justifies the construction of such a large facility in Italy in synergy with the national research institutes and companies and in the framework of the European and international research. It will impact also on R&D work for ILC, FEL, and will be complementarity to other large scale accelerator projects. IRIDE is also intended to be realized in subsequent stages of development depending on the assigned priorities.
△ Less
Submitted 30 July, 2013;
originally announced July 2013.